• Title/Summary/Keyword: Unruptured aneurysms

Search Result 101, Processing Time 0.02 seconds

Sole Stenting Technique for Treatment of Complex Aneurysms

  • Kim, Young-Joon
    • Journal of Korean Neurosurgical Society
    • /
    • v.46 no.6
    • /
    • pp.545-551
    • /
    • 2009
  • Objective : Complex aneurysms such as fusiform and very small aneurysms (< 3 mm) are challenging in neurovascular and endovascular surgery. Author reports follow-up results of 9 cases treated by sole stent technique with pertinent literature review. Methods : A retrospective study was made of 9 patients who were treated by sole stenting technique for cerebral aneurysm between January 2003 and January 2009. Two of them had fusiform aneurysm, 5 had very small aneurysm, and 2 had small saccular aneurysm. Five patients had ruptured aneurysms and four had unruptured aneurysms. Seven aneurysms were located in the internal carotid artery (ICA), 1 in the middle cerebral artery (MCA) and 1 in the basilar artery. Follow-up cerebral angiography was performed at post-procedure 3 months, 6 months, and 12 months. Mean follow-up period is 30 months (ranged from 3 days to 30 months). Results : Aneurysm size was decreased in 6 of 9 cases on follow-up images and was not changed in 3 cases. Although total occlusion was not seen, patients had stable neurological condition and angiographic result. The procedural complication occurred in 2 cases. One was coil migration and the other was suboptimal deployment of stent, and both were asymptomatic. Re-bleeding and thromboembolic complication had not been occurred. Conclusion : Sole stenting technique is relatively effective and safe as an alternative treatment for fusiform and very small aneurysms.

Ruptured Saccular Aneurysm Arising from Fenestrated Proximal Anterior Cerebral Artery : Case Report and Literature Review

  • Kwon, Woo-Keun;Park, Kyung-Jae;Park, Dong-Hyuk;Kang, Shin-Hyuk
    • Journal of Korean Neurosurgical Society
    • /
    • v.53 no.5
    • /
    • pp.293-296
    • /
    • 2013
  • The aneurysm arising from fenestrated proximal anterior cerebral artery (ACA) is considered to be unique. The authors report a case of a 59-year-old woman who presented with a subarachnoid hemorrhage (SAH) secondary to a ruptured aneurysm originating from the fenestrated A1 segment of right ACA. The patient had another unruptured aneurysm which was located at the right middle cerebral artery bifurcation. She was successfully treated with surgical clipping for both aneurysms. From the previously existing literatures, we found 18 more cases (1983-2011) of aneurysms associated with fenestrated A1 segment. All cases represented saccular type of aneurysms, and 79% of the patients had SAH. There were three subtypes of the fenestrated A1 aneurysms depending on the anatomical location, relative to the fenestrated segment. The most common type was the aneurysms located on the proximal end of fenestrated artery (82%). Azygos ACA and hypoplastic A1 were frequently accompanied by the aneurysm (33% and 31%, respectively), and multiple aneurysms were shown in three cases (16%). Considering that fenestrated A1 segment is likely to develop an aneurysm, which has high risk of rupture, early management may benefit patients with aneurysms accompanied by fenestrated proximal ACA.

Intentional Sparing of Daughter Sac from Coil Packing in the Embolization of Aneurysms Causing the Third Cranial Nerve Palsy : Initial Clinical and Radiological Results

  • Kang, Chang-Woo;Kwon, Hyon-Jo;Jeong, Se-Jin;Koh, Hyeon-Song;Choi, Seung-Won;Kim, Seon-Hwan
    • Journal of Korean Neurosurgical Society
    • /
    • v.48 no.2
    • /
    • pp.115-118
    • /
    • 2010
  • Objective : Cerebral aneurysms which cause oculomotor nerve [cranial nerve (CN) III] palsy, are frequently found with a daughter sac of the aneurysm dome. We assumed that CN III might be compressed by the daughter sac and it would be more helpful not to fill the daughter sac with coils than vice versa during endosaccular embolization for recovering from CN III palsy, because it may give a greater chance for the daughter sac to shrink by itself later. We reviewed the initial results of our experiences of such cases. Methods : Among 9 aneurysms accompanied by CN III palsy, 7 (6 unruptured, 1 ruptured) showed a daughter sac. We tried to fill the main dome completely and spare the daughter sac from coil filling to increase the possibility of decompression. We evaluated the short-term effectiveness of this concept using medical records and angiograms. Results : After initial embolization, all of CN III palsy caused by unruptured aneurysms (6/6) resolved completely after various periods (3-90 days) of time. No adverse effects were noted during and after the procedures except for one case of harmless coil stretching during coil filling using double microcatheter. Conclusion : During the coil embolization of the cerebral aneurysm causing CN III palsy, sparing the daughter sac from coil packing while tightly packing the main dome, can be helpful in increasing the effectiveness of decompression. However, a long-term follow-up will be required.

Internal Carotid Artery Reconstruction Using Multiple Fenestrated Clips for Complete Occlusion of Large Paraclinoid Aneurysms

  • Lee, Sang Kook;Kim, Jae Min
    • Journal of Korean Neurosurgical Society
    • /
    • v.54 no.6
    • /
    • pp.477-483
    • /
    • 2013
  • Objective : Although surgical techniques for clipping paraclinoid aneurysms have evolved significantly in recent times, direct microsurgical clipping of large and giant paraclinoid aneurysms remains a formidable surgical challenge. We review here our surgical experiences in direct surgical clipping of large and giant paraclinoid aneurysms, especially in dealing with anterior clinoidectomy, distal dural ring resection, optic canal unroofing, clipping techniques, and surgical complications. Methods : Between September 2001 and February 2012, we directly obliterated ten large and giant paraclinoid aneurysms. In all cases, tailored orbito-zygomatic craniotomies with extradural and/or intradural clinoidectomy were performed. The efficacy of surgical clipping was evaluated with postoperative digital subtraction angiography and computed tomographic angiography. Results : Of the ten cases reported, five each were of ruptured and unruptured aneurysms. Five aneurysms occurred in the carotid cave, two in the superior hypophyseal artery, two in the intracavernous, and one in the posterior wall. The mean diameter of the aneurysms sac was 18.8 mm in the greatest dimension. All large and giant paraclinoid aneurysms were obliterated with direct neck clipping without bypass. With the exception of the one intracavenous aneurysm, all large and giant paraclinoid aneurysms were occluded completely. Conclusion : The key features of successful surgical clipping of large and giant paraclinoid aneurysms include enhancing exposure of proximal neck of aneurysms, establishing proximal control, and completely obliterating aneurysms with minimal manipulation of the optic nerve. Our results suggest that internal carotid artery reconstruction using multiple fenestrated clips without bypass may potentially achieve complete occlusion of large paraclinoid aneurysms.

Endosaccular Treatment of Very Large and Giant Intracranial Aneurysms with Parent Artery Preservation : Single Center Experience with Long Term Follow-up

  • Huh, Chae Wook;Lee, Jae Il;Choi, Chang Hwa;Lee, Tae Hong;Choi, Jae Young;Ko, Jun Kyeung
    • Journal of Korean Neurosurgical Society
    • /
    • v.61 no.4
    • /
    • pp.450-457
    • /
    • 2018
  • Objective : Very large (20-25 mm) and giant (${\geq}25mm$) intracranial aneurysms have an extremely poor natural course, and treatment of these aneurysms remains a challenge for endovascular and surgical strategies. This study was undertaken to describe our experiences of endosaccular treatment of very large and giant intracranial aneurysms with parent artery preservation. Methods : From January 2005 to October 2016, twenty-four very large or giant aneurysms in 24 patients were treated by endosaccular coil embolization with parent artery preservation. Nine (37.5%) aneurysms were ruptured and 15 were unruptured, and of these 15, 11 were symptomatic cases and 4 were incidentally discovered. The cohort comprised 17 women and 7 men of mean age 58.5 years (range, 26-82). Mean aneurysm size was 26.0 mm (range, 20-39) and 13 of the 24 aneurysms were giant. Results : Immediate angiographic results were complete occlusion in nine (37.5%) cases, remnant neck in six (25.0%), and remnant sac in nine (37.5%). Overall procedural related morbidity and mortality rates were 12.5% and 4.2%, respectively. Angiographic follow-up was available in 16 patients (66.7%). Mean and median follow-up periods were 27.2 (range, 2-77) and 10.5 months, respectively. In 12 cases (12/16, 75%) stable occlusion was achieved, four cases (4/16, 25%) had recanalized, and two of these were retreated with additional coiling. At clinical follow-up of the nine ruptured cases, three patients (33.3%) achieved a good clinical outcome (Glasgow outcome scale [GOS] score of 4 or 5), two (22.2%) a poor outcome (GOS score of 2 or 3), and four patients (44.4%) expired (GOS 1). On the other hand, of the 15 unruptured cases, 13 patients (86.7%) achieved a good clinical outcome (GOS 4 or 5), one patient a poor outcome (GOS score of 2 or 3), and one patient expired (GOS 1). Conclusion : The present study shows endosaccular treatment of very large or giant intracranial aneurysms with parent artery preservation is both feasible and effective with acceptable morbidity and mortality.

Bilateral Vertebral Artery Dissecting Aneurysms Presenting with Subarachnoid Hemorrhage Treated by Staged Coil Trapping and Covered Stents Graft

  • Yoon, Seok-Mann;Shim, Jai-Joon;Kim, Sung-Ho;Chang, Jae-Chil
    • Journal of Korean Neurosurgical Society
    • /
    • v.51 no.3
    • /
    • pp.155-159
    • /
    • 2012
  • The treatment of bilateral vertebral artery dissecting aneurysms (VADAs) presenting with subarachnoid hemorrhage (SAH) is still challenging. The authors report a rare case of bilateral VADA treated with coil trapping of ruptured VADA and covered stents implantation after multiple unsuccessful stent assisted coiling of the contralateral unruptured VADA. A 44-year-old woman was admitted to our hospital because of severe headache and sudden stuporous consciousness. Brain CT showed thick SAH and intraventricular hemorrhage. Cerebral angiography demonstrated bilateral VADA. Based on the SAH pattern and aneurysm configurations, the right VADA was considered ruptured. This was trapped with endovascular coils without difficulty. One month later, the contralateral unruptured VADA was protected using a stent-within-a-stent technique, but marked enlargement of the left VADA was detected by 8-months follow-up angiography. Subsequently two times coil packing for pseudosacs resulted in near complete occlusion of left VADA. However, it continued to grow. Covered stents graft below the posterior inferior cerebellar artery (PICA) origin and a coronary stent implantation across the origin of the PICA resulted in near complete obliteration of the VADA. Covered stent graft can be used as a last therapeutic option for the management of VADA, which requires absolute preservation of VA flow.

Angiographic Results of Wide-Necked Intracranial Aneurysms Treated with Coil Embolization : A Single Center Experience

  • Song, Joon Ho;Chang, In Bok;Ahn, Jun Hyong;Kim, Ji Hee;Oh, Jae Keun;Cho, Byung Moon
    • Journal of Korean Neurosurgical Society
    • /
    • v.57 no.4
    • /
    • pp.250-257
    • /
    • 2015
  • Objective : Endovascular treatment of wide-necked intracranial aneurysms is a challenge and the durability and the safety of these treated aneurysms remain unknown. The aim of this study was to evaluate the clinical and long-term angiographic results of wide-necked intracranial aneurysms treated with coil embolization. Methods : Between January 2002 and December 2012, 53 wide-necked aneurysms treated with coil embolization were selected. Forty were female, and 13 were male. Twenty eight (52.8%) were ruptured aneurysms, and 25 (47.2%) were unruptured aneurysms. The patents' medical and radiological records were reviewed retrospectively. Results : Of the 53 aneurysms, coiling alone was employed in 45 (84.9%) and stent-assisted coiling was done in 8 (15.1%). The initial angiographic results revealed Raymond class 1 (complete occlusion) in 30 (56.6%) cases, Raymond class 2 (residual neck) in 18 (34.0%) cases, and Raymond class 3 (residual sac) in 5 (9.4%) cases. The mean angiographic follow-up period was 37.9 months (12-120 months). At the last angiographies, Raymond class 1 was seen in 26 (49.1%) cases, Raymond class 2 in 16 (30.2%), and Raymond class 3 in 11 (20.8%). Angiographic recurrence occurred in 22 (41.5%) patients, with minor recurrence in 7 (13.2%) cases and major recurrence in 15 (28.3%). Retreatment was performed in 8 cases (15.1%). A suboptimal result on the initial angiography was a significant predictor of recurrence in this study (p=0.03). Conclusion : The predictor of recurrence in wide-necked aneurysms is a suboptimal result on the initial angiography. Long-term angiographic follow-up is recommended in wide-necked aneurysms.

Detection of Aneurysms in Patients with Spontaneous Subarachnoid Hemorrhage : A Comparison of Three-dimensional Computed Tomographic Angiography and Conventional Angiography (자발성 뇌지주막하 출혈 환자에서 뇌동맥류 검출에 대한 고식적 혈관조영술과 3차원 전산화 단층 혈관조영술의 비교)

  • Lee, Kyoung Soo;Kang, Chang Gu;Huh, Ryoong;Lee, Sang Hoon;Chung, Ui Wha
    • Journal of Korean Neurosurgical Society
    • /
    • v.30 no.6
    • /
    • pp.711-716
    • /
    • 2001
  • Objectives : Three-dimensional computed tomographic angiography(3D-CTA) is recently developed diagnostic imaging modality. We have studied this noninvasive method for possible role in replacing conventional angiography( CA) in the detection of aneurysms of the circle of Willis in patients with subarachnoid hemorrahge(SAH). Methods : We studied retrospectively, the 100 patients with SAH or unruptured aneurysms admitted to our hospital from October 1997 to December 1998. Among there, 85 patients underwent CTA, 82 patients underwent CA and 67 patients underwent both of CTA and CA. 3D-CTA was obtained using maximum intensity projection(MIP) and shaded-surface display(SSD) reconstruction. Results : Total 107 aneurysms were detected in 92 patients, and 64 aneurysms were detected in 67 patients underwent both CTA and CA. In five cases of those 67 cases, aneurysms were detected by CA but not by 3D-CTA. The detection rate of aneurysms(91.8%) and the detection rate of parent artery in cases of anterior communicating artery aneurysms(86.9%) with total 3D-CTA were relatively compatible with that of CA. But 3D-CTA was not enough in detection of posterior communicating artery aneurysms, internal carotid artery aneurysms as well as small sized aneurysm(<3mm). Conclusion : We consider CTA is valuable in as a screening test for cerebral aneurysm and follow-up test. And it is also valuable in early surgery for patients with aneurysmal rebleeding because of simple, quick, non-invasive method.

  • PDF

Surgical Flow Alteration for the Treatment of Intracranial Aneurysms That Are Unclippable, Untrappable, and Uncoilable

  • Lee, Sung Ho;Ahn, Jae Sung;Kwun, Byung Duk;Park, Wonhyoung;Park, Jung Cheol;Roh, Sung Woo
    • Journal of Korean Neurosurgical Society
    • /
    • v.58 no.6
    • /
    • pp.518-527
    • /
    • 2015
  • Objective : The treatment of complex intracranial aneurysms remains challenging. One approach is the application of surgical flow alteration to treat aneurysms that are neither clippable, trappable, or coilable. The efficacy and limitations of surgical flow alteration have not yet been established. Methods : Cases of complex aneurysms treated with surgical flow alteration (proximal occlusion with or without bypass, distal occlusion with or without bypass and bypass only) were included in this retrospective study. Results : Among a total of 16 cases, there were 7 giant aneurysms (${\geq}25mm$ diameter) and 9 large aneurysms (>10 mm diameter); 15 of 16 aneurysms were unruptured. There were 8 aneurysms located in the anterior circulation, while the other 8 were in the posterior circulation. Aneurysms were treated with proximal occlusion in 10 cases and distal occlusion in 5 cases; in 1 case, the aneurysm occluded spontaneously after bypass without parent artery occlusion. All but 2 cases underwent prior or concurrent bypass surgery. Complete obliteration of the aneurysm at the latest imaging follow-up was shown in 12 of 16 cases (75.0%). Bypass patency was confirmed in 13 of 15 cases (86.7%). Surgery-related morbidity developed in 3 cases (18.8%, Glasgow outcome scale of 4) and all were perforator infarctions. There were no mortalities. Conclusion : Surgical flow alteration resulted in a high rate of aneurysmal obliteration with acceptable morbidity. Although several limitations remained, it could represent an alternative method for treating complex aneurysms.

Clinical and Radiogical Outcomes of Endovascular Detachable Coil Embolization in Paraclinoid Aneurysms : A 10-Year Experience

  • Jin, Sung-Chul;Kwon, Do-Hoon;Ahn, Jae-Sung;Kwun, Byung-Duk;Song, Young;Choi, Choong-Gon
    • Journal of Korean Neurosurgical Society
    • /
    • v.45 no.1
    • /
    • pp.5-10
    • /
    • 2009
  • Objective : Direct surgical clipping of paraclinoid aneurysms poses technical challenges to even very experienced neurosurgeons, making endovascular treatment an alternative treatment modality in many centers. We have therefore retrospectively evaluated the safety and efficacy of endovascular detachable coil embolization of paraclinoid aneurysms. Methods : From June 1997 to June 2007, 65 patients underwent endovascular detachable coiling for 67 paraclinoid aneurysms (of which 9 were ruptured and 58 were unruptured) in our institute. Their medical records, radiological images and readings, and operation records were reviewed retrospectively. Results : After the initial embolization procedure, complete occlusion was achieved in 29 (43.3%) of the aneurysms treated by endovascular detachable coiling. Six aneurysms required retreatment, with two each requiring one, two, or three additional endovascular procedures. Fifty-five (82.1%) aneurysms were measured by three-dimensional time of flight (TOF) magnetic resonance images (MRI) or transfemoral cerebral angiography (TFCA) at a mean follow-up of 29.7 months (range from 4 to 94 months), with 39 aneurysms (70.9%) showing complete occlusion. Thromboembolic events (3.8%) were the most frequent complication. Rupture did not occur during or after any of the procedures. According to the Glasgow Outcome Scale (GOS), 98.4% of the patients treated by coil embolization had a score of 4 or 5. Conclusion : Our results indicate that endovascular detachable coiling is a safe and effective treatment modality in paraclinoid aneurysms.