• Title/Summary/Keyword: Universal Joint

Search Result 120, Processing Time 0.033 seconds

Effect of Joint Errors in a Cubic Parallel Device (육면형 병렬기구에서의 조인트 오차의 영향)

  • Lim, Seung-Reung;Choi, Woo-Chun;Song, Jae-Bok;Hong, Dae-Hie
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.18 no.6
    • /
    • pp.87-92
    • /
    • 2001
  • An error analysis is very important for a precision machine to estimate its performances. This study proposes a new parallel device, cubic parallel manipulator. Errors of the proposed cubic parallel manipulator include upper and down universal joint errors, due to the directional changes in the forces in the links, and actuation errors. An error analysis is presented based on an error model formed through the relation between the universal joint errors of the cubic parallel manipulator and the end effector accuracy. The analysis shows that the method can be used in predicting the accuracy of other cubic parallel devices.

  • PDF

Durability Analysis due to the Shape Change of Universal Joint (유니버셜 조인트의 형상 변화에 따른 내구성 해석)

  • Han, Moonsik;Cho, Jaeung
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.12 no.4
    • /
    • pp.69-74
    • /
    • 2013
  • According to the axial torsion applied at power transmission and the vibration from the roughness of road surface, this paper analyzes the stresses on two kinds of universal joint model. As stress and deformation at model 2 becomes smaller than model 1 on structural analysis, model 2 is more stabilized than model 1. The natural frequencies at model 1 and 2 are 7,040 and 9,540 Hz respectively. As the natural frequency range of model 2 becomes higher than model 1, model 2 becomes safer than model 1. Critical frequencies at these models are calculated through harmonic response analyses. On critical frequencies at model 1 and 2, the stress at model 2 becomes lower than 2 times as much as model 1 and the deformation at model 2 becomes lower than 4 times as much as model 1. Model 2 on durability is thought to become better than model 1. This study result is applied with the design of safe universal joint and it can be useful to improve the durability by predicting prevention against the deformation due to its vibration.

Effect of U-Joint Errors Analysis for a Cubic Parallel Device (육면형 병렬기구에서의 유니버설 조인트 오차의 영향)

  • Lim, Seung-Reung;Choi, Woo-Chun
    • Proceedings of the KSME Conference
    • /
    • 2000.11a
    • /
    • pp.789-794
    • /
    • 2000
  • This study proposes an error analysis for a cubic parallel device. There are many sources of errors in the device. An error analysis is presented based on an error model formed from the relation between the universal joint error of the cubic parallel manipulator and the end effector accuracy. The analysis shows that the method can be used in evaluating the accuracy of a parallel device.

  • PDF

Study on the Fatigue Test and the Accelerated Life Test for Dental Implant using Universal-Joint Test Type (유니버설조인트 시험방식을 이용한 치과용 임플란트의 피로시험 및 가속수명시험에 관한 연구)

  • Do, Gyeong Hun;Lee, Seok Jin;Kim, Jong Mi;Kim, Sung Min
    • Journal of Applied Reliability
    • /
    • v.17 no.1
    • /
    • pp.50-57
    • /
    • 2017
  • Purpose : This paper is a comparative analysis results of the fatigue test for dental implants and accelerated life test by using a static type loading device commonly used in Korea and a dynamic type loading device (universal-joint) recommended by FDA. Methods : Fatigue tests of dental implant is based on ISO 14801 and classified into static load test and dynamic load test. The tests were carried out on three test specimens by four load stress steps under each loading device. For analysis on failure mode such as crack, fracture and permanent deformation of test specimens, we used X-ray three-dimensional computed tomography on test specimens before and after the fatigue tests. The design of the accelerated life test was based on the analysis results of the fatigue life data obtained from the dynamic load test and the statistical analysis software (Minitab ver.15) was used to analyze the appropriate life distribution. Results : As a result of the fatigue tests and the accelerated life tests at same acceleration condition under each test method, the fatigue life under the dynamic type loading device (universal-joint) was shorter than when static type loading device was applied. Conclusion : This paper can be used as a reference when the universal-joint type loading device for implants fatigue test is applied as ISO 14801.

Static and Dynamic Analysis of Automotive Steering System (자동차 조향 장치의 정적 및 동적 응력해석)

  • Cho, Jae-Ung;Han, Moon-Sik
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.7 no.3
    • /
    • pp.36-40
    • /
    • 2008
  • This study is analyzed by the simulation of automotive steering system. The maximum equivalent stress of $2.2418{\times}109Pa$ and the maximum total displacement of 0.014929m are shown at the universal joint and its lower part respectively. As the minimum cycle of 34.047 is shown at the universal joint in case of fatigue analysis, it is possible to have greatest damage at this part. In case of natural frequency analysis at vibration, its frequency of 47 to 59Hz is occurred generally. The maximum total displacement of 0.5m is shown at handle on the natural frequency of 57 to 58Hz. And the displacement over 2m is shown at the lower part of universal joint on the natural frequency of 58 to 59Hz. As the basis of the simulation analysis of steering system, passenger's comfort of car body can be improved in the design of practical part and the design effect necessary to safe driving can be promoted.

  • PDF

Finite Element Analysis for Performance Evaluation of the Seal in a Universal Joint Bearing (유니버설 조인트 베어링용 시일의 성능평가를 위한 유한요소해석)

  • Kim, Tae-Wan;Moon, Suk-Man;Koo, Young-Pil;Cho, Yong-Joo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.18 no.9
    • /
    • pp.140-146
    • /
    • 2001
  • Seals in a universal joint bearing are important components reinforcing lubrication performance by holding lubricant and preventing infiltration of dust, moisture, etc.. There is a great difference in seal performance according to seal shape and bonding position. Therefore, in this study, as for both the lip type seal and the O-ring type seal, FE analysis is conducted using Mooned-Rivlin Model. The results show that O-ring type seal does not have any effect of misalignment angle compared with lib type seal, which is more profitable.

  • PDF

FEM Analysis for Performance Evaluation of Seal in Universal Joint Bearing (유니버설 조인트 베어링용 Seal의 성능평가를 위한 유한요소해석)

  • 김태완;문석만;구영필;조용주
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.571-574
    • /
    • 2000
  • Seals in universal joint bearing are a important component reinforcing lubrication performance by holding a lubricant and preventing infiltration of dust, moisture, etc. There is a great difference in seal performance according to seal shape and bonding position. Therefore, in this study, as for the lib type seal and O-ring type seal, FEM analysis are conducted using Mooney-Rivlin Model. The results are indicate that O-ring having higher contact stress and larger contact area than lib type is more profitable.

  • PDF

Coupled Vibration of Lateral and Torsional Vibrations in a Rotating Shaft Driven through a Universal Joint - Derivation of Equations of Motion and Stability Analysis - (유니버셜 조인트에 의해 구동되는 회전축의 횡진동과 비틀림진동의 연성진동 - 운동방정식의 유도 및 안정성해석 -)

  • 김정렬;전승환;이돈출
    • Journal of KSNVE
    • /
    • v.9 no.3
    • /
    • pp.461-465
    • /
    • 1999
  • This paper presents theoretical analyses for unstable vibrations caused by the couple of bending and torsion in a rotating shaft driven through a universal joint. A driving shaft is assumed to be rigid and to rotate with a constant angular velocity. The driven shaft system consists of a flexible shaft with a circular section and a symmetrical rotor attached at a point between the shaft ends. Equations of motion derived hold with an accuracy of the second order of shaft deformations, and are analyzed by the asymptotic method. The vibrations become unstable when the driving shaft rotates with the angular velocity to be approximately equal to half of the sum of the natural frequencies for whirling and torsional vibrations.

  • PDF

An Implementation of Smooth laser image using universal joint (유니버셜 관절을 이용한 유연 레이저 영상 구현)

  • 김태강;이건영
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2000.10a
    • /
    • pp.347-347
    • /
    • 2000
  • Nowadays, the Laser image is used to realize multi-media show for events, an advertising media and 3D simulation, realization of video image and so on. It is a hot issue to realize the laser image like computer graphic image. The image used in laser projector is vector graphic image that is described by linking point to point. A computer makes this continuous vector graphic images so that the image shows as an animation. A control signal converted by a computer makes the laser projector draw image. Two motors and universal joint are used to realize 2D laser image in this study. Developing a controller applied Look-ahead algorithm and software to interface with personal computer, This study is the chief aim of improving difference of moving velocity that is appeared from edge of vector graphic image and disparity of graphic density.

  • PDF