• Title/Summary/Keyword: Unit load

Search Result 1,517, Processing Time 0.028 seconds

Fatigue Strength Evaluation of the Aluminum Car body of Urban Transit Unit by Large Scale Dynamic Load Test (도시철도차량 알루미늄 차체의 동적 하중 시험에 의한 피로 강도 평가)

  • Seo, Sung-Il;Park, Choon-Soo;Shin, Byung-Cheon
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.1051-1055
    • /
    • 2003
  • Aluminum carbody for rolling stocks is light and perfectly recycled, but includes severe defects which are very dangerous to fatigue strength. Structural integrity assessment for the carbody by static load test has been performed up to date. In this study, to evaluate fatigue strength of the aluminum carbody of urban transit unit. a testing method to simulate dynamic loading condition was proposed and the fatigue strength of the carbody was evaluated. The dynamic load test results showed that the alternating stress ranges were different from the estimated ranges based on the static test results. Excessive stress ranges at the center are thought to come from the flexible motion of the carbody. published fatigue test data for aluminum components, but variation of alternating acceleration along the length due to flexibility of carbody yielded unexpected results. Because fatigue strength based on the static test results may be overestimated at the center, modification of testing method is necessary.

  • PDF

Improvement and Application of Total Maximum Daily Load Management System of Korea: 1. Calculation of Total Amount of Pollutant Load in the Anyangcheon Watershed (우리나라 오염총량관리제도의 개선 및 적용: 1. 안양천 유역의 오염부하량 산정)

  • Kim, Kyung-Tae;Chung, Eun-Sung;Kim, Sang-Ug;Lee, Kil Seong;Seong, Jin-Young
    • Journal of Korean Society on Water Environment
    • /
    • v.25 no.6
    • /
    • pp.972-978
    • /
    • 2009
  • This study modifies the present total maximum daily load (TMDL) system of Ministry of Environment and applies to the Anyangcheon watershed. Hydrologic Simulation Program-FORTRAN (HSPF) model is used to simulate both runoff and non-point source pollution, simultaneously, instead of QUAL2E. The drought flow (355th daily flow) is proposed for the target water quantity since it is easier to satisfy low flow (275th daily flow) for the target water quality than drought flow. The increase of discharge is more than the increase of pollutant load except for the period under low flow. The measured unit loads for non-point source are used to consider the regional runoff characteristics. The measured water quantity and quality data are used since the ministry of environment supports only water quality. This analysis results show some reasons for the improvement of the present TMDL system of Korea.

Method for Maximal Utilization of Idle Links for Fast Load Balancing (신속한 부하균등화를 위한 휴지링크의 최대 활용방법)

  • Im, Hwa-Gyeong;Jang, Ju-Uk;Kim, Seong-Cheon
    • Journal of KIISE:Computer Systems and Theory
    • /
    • v.28 no.12
    • /
    • pp.632-641
    • /
    • 2001
  • In this paper, we introduce new methods for hiding computation overheads involved in load redistributing for parallel computer of hypercube, mesh and tree topologies. The basic idea is either coalescing some phases of load redistributing to overlap the transfer on different links or dividing each phase into steps to pipeline the transfer of load unit by unit for maximum utilization of links. They proved effective in making links busy transmitting load as soon as possible, hence reducing the computation overheads involved in balancing. Proposed techniques experimented on hypercube, mesh or tree topologies reduce communication overheads by 20% to 50% compared with known methods.

  • PDF

An Analysis on the Causal Relation Among SMP, Base-Load Share, LNG Import Price, and Exchange Rate (전력계통한계가격(SMP)과 기저발전비율, LNG도입가격, 환율 간 인과관계 분석)

  • Park, Min Hyug;Moon, Yang Taik;Park, Jung Gu
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.7
    • /
    • pp.97-105
    • /
    • 2014
  • This article examines the causality relationship among SMP, base-load share, LNG import price, and exchange rate in Korean power market during 2002~2012, using unit root test, cointegration test, and vector error correction model(VECM). The cointegration test shows that 4 variables without unit root have been in the long-run causality. As the results of ECM, SMP is analyzed to have been unilaterally caused from LNG import price and base-load share in the shot-run, while it has been unilaterally caused from LNG import price and exchange rate in the long-run. This article has the following policy implications: the adjustment of exchange rate to reduce he risk of LNG import price and the proper securement of base-load share for the long-run stability of SMP.

Pneumatic circuit design and Performance test of Air balancer (에어밸런서 공압 회로의 설계 및 성능 실험)

  • Kim, D.S.;Bae, S.K.
    • Transactions of The Korea Fluid Power Systems Society
    • /
    • v.3 no.3
    • /
    • pp.20-24
    • /
    • 2006
  • Air balancer is a conveyance cargo-handling machine, used in assembly and process lines of car and machining industries. This can lift up an object, the weight of which is from 5 to 200 kg, and moves it to a position. As industrial technologies evolve, it is required to move an object and fit it into a specified position with greater accuracy, rather than performing simple tasks such as lifting objects up and down as conventional ones do. There is also a demand to handle an object with one hand, rather than with two hands,. Through designs of manifold unit for an air balancer function, pilot regulator unit to keep pressure constant, hand unit for an accurate load perception function, and air balancer circuit, this study enables everybody to work it with ease and convenience. Experiments and comparisons were conducted for the performance evaluation of the circuit.

  • PDF

Determination of optimal unit commitment and load dispatch for thermal power system by DP method (DP법에 의한 화력계통의 최적병렬치수 결정 및 부하배분)

  • 양흥석;이문호
    • 전기의세계
    • /
    • v.21 no.2
    • /
    • pp.34-40
    • /
    • 1972
  • This paper describes the problem of the shortange-economic-scheduling for unit commitment and load dispatching in thermal power system. For economic operation of thermal system, the optimum time of startup and shoutdown of the generating unit must be determined so as to minimize the sum of generating and starting fuel cost over a given period. The above problems are analyzed for the purpose of the application of Dynamic Programing Method. Also the technique of Dynamic Programming is applied to the problems. For the illustative purpose, a case study was made on a model system composed of eight units and the computing time was about 190 seconds by IBM 360-40 system. Therefore, one can utilize this suggested method on any of the practical power systems.

  • PDF

Characteristics and Unit Load of Pollutants at a Paddy Field Area with Large-Scaled Plots (대구획 광역논에서의 오염부하특성과 원단위)

  • Kim, Kyu-Seong;Kim, Jin-Soo;Oh, Seung-Young;Yoon, Chun-Gyeong
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2001.10a
    • /
    • pp.390-393
    • /
    • 2001
  • Mass balance and unit load of pollutants were investigated at paddy field area during irrigation periods in 1999 and 2000. The amounts of irrigation water during irrigation periods were 3,690mm in 1999 and 3,160mm in 2000. The concentration of surface outflow is not so high as that of irrigation because 44% of irrigation water discharge without entering the paddy plots. The unit loads of pollutants during irrigation periods were estimated 19.2kg/ha for T-N, 0.29kg/ha for T-P and 47.5kg/ha for COD.

  • PDF

A Study on Economic Analyse for Direct Load Control considering Energy Payback (Energy Payback을 고려한 직접부하제어의 경제성 분석)

  • Kim, H.J.;Kim, I.S.;Kim, Y.H.;Lee, Buhm;Choi, S.K.;Moon, J.H.;Lee, H.N.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07a
    • /
    • pp.311-314
    • /
    • 2001
  • This paper describes the optimizing method of direct load control (DLC) considering unit commitment which is based on dynamic programming. To solve DLC problem considering unit commitment, 3-dimensional dynamic programming as a new unit commitment method is developed. And, energy payback is concerned for DLC. As a result, optimization of operating schedule with DLC is possible. This method is applied to the test system, and usefulness of the method is verified.

  • PDF

Control Algorithm of Hybrid System for Feeder Flow Mode Operation in Microgrid (마이크로그리드에서 하이브리드 시스템의 Feeder Flow Mode 운영을 위한 제어 알고리즘)

  • Moon, Dae-Seong;Seo, Jae-Jin;Kim, Yun-Seong;Won, Dong-Jun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.1
    • /
    • pp.1-7
    • /
    • 2011
  • Active power control scheme for distributed generation in microgrid consists of feeder flow control and unit power control. Feeder flow control is more useful than the unit power control for demand-side management, because microgrid can be treated as a dispatchable load at the point of common coupling(PCC). This paper presents detailed descriptions of the feeder flow control scheme for the hybrid system in microgrid. It is divided into three parts, namely, the setting of feeder flow reference range for stable hybrid system operation, feeder flow control algorithm depending on load change in microgrid and hysteresis control. Simulation results using the PSCAD/EMTDC are presented to validate the inverter control method for a feeder flow control mode. As a result, the feeder flow control algorithm for the hybrid system in microgrid is efficient for supplying continuously active power to customers without interruption.

Basic Monitoring Concept for Revised Unit Load on NPS (비점오염원 원단위 개정을 위한 조사연구 방향)

  • Shin, Dongseok
    • Journal of Korean Society on Water Environment
    • /
    • v.23 no.4
    • /
    • pp.429-433
    • /
    • 2007
  • Many researchers have made a study of NPS unit-loads and the scientific evaluation method which need for formulating and enforcing a Total Maximum Daily Load (TMDL) management system and modifying a pollutant discharge loadings function. Some showed the event mean concentration (EMC) on single land-use. For the most parts, as the results showed on multiple land-uses, those cannot be used for NPS unit-loads calculation. NPS runoff shows various phenomena depending on rainfall monitoring data, therefore sampling methods and frequency for NPS monitoring must be different from the general monitoring for water quality trend assessment.