• Title/Summary/Keyword: Unit area load

Search Result 214, Processing Time 0.029 seconds

Pile Load test on a Large Barrette Pile and a Bored Pile for the Identification of the Load Transfer Characteristics (대형 바렛말뚝과 현장타설말뚝의 하중전이특성 파악을 위한 재하시험)

  • Han Sung-Gil;Park Jong-Kwan
    • Journal of the Korean Society for Railway
    • /
    • v.9 no.4 s.35
    • /
    • pp.493-498
    • /
    • 2006
  • In this study, two large pile load tests were performed in the deep sand gravel deposit of Nakdong river basin so that the characteristics of the load transfer was identified. The fully instrumented rectangular barrette pile in the size of $1.5\times3.0m$ and the circular bored pile of the diameter 1.5 m were placed into the ground below 50 m. Under the applied loads of 2,400 tonf and 4,000 tonf, the test results of the load transfer showed the portion of 83% and 93% of the applied loads on the barrette pile and the bored pile, respectively, were supported by the skin friction along the pile shaft. It was revealed that the most of these skin friction mobilized in sand layer underlying clay layer having N-value more than 30 and that the friction per unit area of the bored pile was larger than the friction of barrette pile. However, if embedded in the stiff sand graval layer, the both piles were proven to be sufficient for using as the friction piles.

Biomechanics of the Lumbar Intervertebral Disk (요추디스크의 생체역학)

  • Park Ji-Whan
    • The Journal of Korean Physical Therapy
    • /
    • v.2 no.1
    • /
    • pp.103-112
    • /
    • 1990
  • The intervertebral disc in the anterior portion of the function unit gives the spine its flexibility. The disc is attached closely to the vertebral endplates. Between these endplates and the annulus fibrosus, the nucleus pulposus of the lumbar disc is enclosed in a circle of unyielding tissues. Compressive pressure placed on the disc is dissipated circumferentially in a passive manner In response to the greater axial forced exerted on the lumbar spine in comparison to the cervical and thoracic spines, the nucleus pulposus has its greatest surface area in the lumbar spine. The intervertebral disc is not only structure that helps diss pate stresses placed on the spine. With flexion, extension, rotation, or shear stress, the load distribution on the function unit is shared by the intervertebral disc, anterior and posterior longitudinal ligaments, the facet joints and capsules, and other ligamentous structures like the ligamentum flavum, interspinous and supraspinous ligaments, which attach to the posterior elements of the functional unit.

  • PDF

Stability Analysis and Effect of CES on ANN Based AGC for Frequency Excursion

  • Raja, J.;Rajan, C.Christober Asir
    • Journal of Electrical Engineering and Technology
    • /
    • v.5 no.4
    • /
    • pp.552-560
    • /
    • 2010
  • This paper presents an application of layered Artificial Neural Network controller to study load frequency control problem in power system. The objective of control scheme guarantees that steady state error of frequencies and inadvertent interchange of tie-lines are maintained in a given tolerance limitation. The proposed controller has been designed for a two-area interconnected power system. Only one artificial neural network controller (ANN), which controls the inputs of each area in the power system together, is considered. In this study, back propagation-through time algorithm is used as neural network learning rule. The performance of the power system is simulated by using conventional integral controller and ANN controller, separately. For the first time comparative study has been carried out between SMES and CES unit, all of the areas are included with SMES and CES unit separately. By comparing the results for both cases, the performance of ANN controller with CES unit is found to be better than conventional controllers with SMES, CES and ANN with SMES.

Analysis of the Reduction of Light-weight Imapct Noise for Load Condition of Floating Floor (뜬바닥층의 하중조건에 따른 경량충격음 저감량 분석)

  • Kim, Myung-Jun;Lee, Sung-Ho;Yang, Jae-Hoon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.11a
    • /
    • pp.356-360
    • /
    • 2006
  • Recently, for the purpose of improving the isolation performance of impact noise, many resilient materials have been installed in a residential building. As one of the reduction method for improving the performance of light-weight impact noise, this study is focused on the load condition of floating layer over resilient material. We studied the correlation between the mass or load of the floating layer and the reduction of light-weight impact noise by experiments in reverberation chamber for testing the impact noise. The results show that the reduction of impact noise is improved by increasing the mass per unit area of floating layer until about $140kg/m^2$. But the reduction is not obvious by adding extra mass on the floating layer.

  • PDF

Estimating of Pollutant Load at Paddy Field Area (광역논에서의 오염물질 부하량 산정)

  • Kim, Byoung-Hee;Yoon, Chun-Gyeong;Hwang, Ha-Sun
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2001.10a
    • /
    • pp.509-512
    • /
    • 2001
  • In this study, pollutant load from paddy field was estimated by regression equation from 5 to 8 in 2001. During study period, total rainfall was 511.3mm and runoff discharge was 968.71mm. Regression equation between flow rate(m3/s) and pollutant loading rate(g/s) is exponential relationship. For site 1, coefficient of determination (R2) for $COD_{cr}$, T-P, T-N were 0.7068, 0.8441, 0.6806 respectively and site 2, 0.9369, 0.8855, 0.4262 respectively. Considering unit loads, Jun was the highest valus as 13.85 $COD_{c}kg/km2/day$, 0.24 T-Pkg/km2/day, 1.22 T-Nkg/km2/day. Until study period, total $COD_{cr}$ load estimated regression equation is 19.32kg/km2/day and, T-P, T-N were 0.264, 1.88 respectively

  • PDF

A Study on How to Predict and Evaluate the Dynamic Stiffness Criteria of Exposure Equipment in Precision Industrial Factory(TFT-LCD) (정밀산업(TFT-LCD) 공장 내 노광장치의 대형 세대별 동강성 허용규제치 예측 및 평가에 관한 연구)

  • Baek, Jae-Ho;Chun, Chong-Keun;Park, Sang-Gon
    • Journal of the Semiconductor & Display Technology
    • /
    • v.10 no.4
    • /
    • pp.15-20
    • /
    • 2011
  • The lithography system installed inside precision industry's (e.g. TFT-LCD) production factories are increasing in size, thereby increasing its dynamic load along with it. Such condition causes vibration within the area where the system is installed, which then negatively affects the production line to produce defective products. To prevent this type of situation, the facilities should adopt dynamic design that considers the lithography system's dynamic load. This study predicts the maximum value allowed for dynamic stiffness (which is a ratio of vibration response against a single unit of the dynamic load) of the lithography system and explains the result of its application on actual structures inside the facilities.

Characteristics of Pollutants Discharge from Hoengseong Watershed during the Dry and Rainy Seasons (횡성호 유역의 비강우시 및 강우시 오염물질 유출특성)

  • Roh, Sung-Duk;Kim, Jang-Hyun;Lee, Dae-Keun;Kim, Seon-Joo;Sohn, Byeong-Yong;Chun, Yang-Kun
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.4
    • /
    • pp.695-705
    • /
    • 2006
  • This study was carried out to make a basic information for establishment of countermeasures against water pollution of Hoengseong watershed, accordingly we investigated the characteristics of pollutants discharge and estimated the unit loads from Hoengseong watershed. Seven sites (S1~S7) were selected for sampling and samples were taken 4 times during the dry and rainy seasons, respectively. During rainfall events, measured site mean concentration (SMC) ranges of $BOD_5$, $COD_{Mn}$, TOC, SS, Turbidity, T-N and T-P were 0.8~1.3 mg/L, 2.3~6.3 mg/L, 1.284~2.110 mg/L, 3.4~69.3 mg/L, 2.36~52.68 NTU, 1.243~1.669 mg/L and 0.025~0.070 mg/L, respectively. And the calculated annual unit loads of $BOD_{5}$, $COD_{Mn}$, SS, T-N and T-P in Hoengseong watershed were 1.327 kg/ha/yr, 7.349 kg/ha/yr, 87.075 kg/ha/yr, 1.848 kg/ha/yr and 0.103 kg/ha/yr, respectively. It was difficult to directly compare the unit loads proposed in this study with the estimated existing those. Because the unit loads in this paper were estimated not by land use types, but by complex land use of non-urban area. From the survey results, they showed that the unit loads in Hoengseong watershed were similar to those exisiting in the forest area, and showed lower than those existing in the paddy/dry field.

A Study on Bearing Capacity Characteristics of Group Crushed-Stone Compaction Piles (군쇄석다짐말뚝의 지지력 특성에 관한 연구)

  • Hwang, Geun-Bae;Lee, Min-Hee;Shin, Hyeon-Cheol;Choi, Yong-Kyu
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2005.03a
    • /
    • pp.705-712
    • /
    • 2005
  • Among soft ground treatment methods with granular soil used in domestic, the sand compaction pile method has been utilized greatly, but, as a result of exhaustion of sand and increase of unit cost, a necessity of an alternative method is suggested. In this study, the static load tests for group crushed-stone compaction piles which were constructed at in-situ site were performed. Pile diameter was 700mm and area of loading plates were changed. The static load tests of single and group piles were performed for area replacement ratio of 20, 30 and 40%. Based on test results, bearing capacity of group crushed-stone compaction pile were estimated. The more both single pile and group pile increase, the more yield bearing capacity tended to increase. Also, the yield bearing capacity of a group pile is about 50% less than the yield bearing capacity of a single pile. If the ground reinforced with the crushed-stone compaction pile is replacement ratio of $20{\sim}40%$, RIYB of both single pile and group pile increases qualitative tendency of linear more than original ground

  • PDF

A Study on the Fire Characteristics of Palletized Unit-Load Commodities on Racks (랙크 내 파렛트단위 적재물품의 화재특성에 관한 연구)

  • Cho, Gyu-Hwan;Yeo, In-Hwan
    • Fire Science and Engineering
    • /
    • v.30 no.3
    • /
    • pp.23-30
    • /
    • 2016
  • A fire extinguishing system for a rack warehouse was recently designed, which only consider the gross area and number of stories. However, the design of such a system should take into account not only the planar structuree, but also the elevation perspectives due to its vertical structure. Moreover, the fire load of the commodities palletized on the racks should be considered, in order to design a performance-based fire safety system that is appropriate for these environmental conditions. For this reason, this study analyzed the fire characteristics of the commodities palletized on the racks (pallet + the commodities in a box unit + vinyl packing material), taking into consideration the results of a field investigation conducted in Korea, as well as the Hazard Classifications of Commodities used in other countries. Through this analysis, the heat release rate (HRR) and smoke production rate (SPR) were derived.

Implementation of Wireless Multiple Integrated Laser Engagement System using ZigBee-based Persinal Area Network (ZigBee기반 개인영역망을 사용한 무선 다중 통합 레이저 교전 시스템의 구현)

  • Ki, Hyeon-Cheol
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.14 no.4
    • /
    • pp.85-90
    • /
    • 2014
  • We realized a wireless multiple integrated laser engagement system composed of personal area network using Zigbee. The wireless laser detector had function of analog signal processor, decoder and wireless communication. However, it should consume low power and be small and light in order to be attached to a soldier's body. The decoder was realized in software to be small and light. We induced low power consumption as reducing the load of system using a narrow band optical filter. The fabricated wireless laser detector functioned well in optically noisy environment. Although the communication to the player unit through the wireless personal area network was dependent on the attachment place it was perfectly worked with transmission power of -40.2dBm or more.