• Title/Summary/Keyword: Unit Process

Search Result 3,645, Processing Time 0.033 seconds

A study on the Architectural Planning Program for the type and scale computation of Operating-Unit (수술유니트의 유형 및 규모 산정을 위한 건축계획 프로그램에 관한 연구)

  • Chai, Choul-Gyun
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.8 no.2
    • /
    • pp.43-50
    • /
    • 2002
  • By reason of development of anesthesia, advent of new surgical operation type and change of hygiene criterion and economical index is increasing recently request about alteration of existing unit or new surgical operation-unit type. The purpose of this study is to provide of architectural planning program for the type decision and the scale computation of operating-unit in healthcare facilities. As a result of this study, presented program of six type according to surgical operation process including space and time side.

  • PDF

LTPS technology for improving the performance of AMOLEDs

  • Choi, Hong-Seok;Choi, Jae-Sik;Hong, Soon-Kwang;Kim, Byeong-Koo;Ha, Yong-Min
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2007.08b
    • /
    • pp.1781-1784
    • /
    • 2007
  • The increase of repetition rate, the dithering of laser optics, and the extension of pulse duration time are major approaches in improving the picture quality of AMOLEDs fabricated by excimer laser crystallization (ELC). Advanced solid phase crystallization (ASPC) has been developed to improve the uniformity and the process cost. Even though the mobility of ASPC-TFT is lower than that of ELC-TFT, it is high enough to drive AMOLED pixels.

  • PDF

A Study on the Stabilization Process of Truss Structure Stabilized by Cable Tension (장력안정트러스 구조물의 안정화기법에 관한 연구)

  • 권택진;한상을;김충한;최옥훈
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 1996.10a
    • /
    • pp.330-339
    • /
    • 1996
  • The primary objective of this paper is to grasp characteristics of unit system, for the stabilization of stablized truss structure that is an assemblage of unit system by prestress. This unit system is composed of a central post and eight cables, and is connected by hinge joints, and stabilized by the self-equilibrated stress system. As this unit structures itself is a statically closed and stabilized system individually, it can be employed to assemble a structure with a variety of configuration. In this paper, for the stabilization of truss structure stabilized by cable tension, it is proposed the self-equilibrated axial mode equation and the range of the various geometrical parameter about unit system.

  • PDF

Testing for a Unit Root in an ARIMA(p,1,q) Signal Observed with Measurement Error

  • Lee, Jong-Hyup;Shin, Dong-Wan
    • Journal of the Korean Statistical Society
    • /
    • v.24 no.2
    • /
    • pp.481-493
    • /
    • 1995
  • An ARIMA signal observed with measurement error is shown to have another ARIMA representation with nonlinear restrictions on parameters. For this model, the restricted Newton-Raphson estimator(RNRE) of the unit root is shown to have the same limiting distribution as the ordinary least squares estimator of the unit root in an AR(1) model tabulated by Dickey and Fuller (1979). The RNRE of parameters of the ARIMA(p,1,k) process and unit root tests base on the RNRE are developed.

  • PDF

PERIODIC SAFETY REVIEW ON KORI UNIT 1 (고리 1호기 주기적안전성 평가)

  • Kim, Tae-Ryong
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 2003.05a
    • /
    • pp.403-414
    • /
    • 2003
  • Periodic safety review on Kori Unit 1 has been successfully done for the first time in Korea. 11 safety factors of the review were fully evaluated in accordance with the domestic legal system. Although it is the oldest nuclear power plant in Korea, Kori Unit 1 was found to have maintained good operating conditions and continuously enhanced its safety by implementing post-TMI action plans and other safety issues, such as replacing steam generators and process/control system. It can be therefore confirmed that safe operation of Kori Unit 1 is guaranteed until next periodic safety review. Nevertheless, some corrective action items were recommended to enhance further its safety level, such as equipment qualification, additional ageing management program, strengthening of some procedures related to administration and human factor. The results of PSR can be utilized for the continued operation beyond the design life as long as the plant safety is maintained and improved. Experiences of the PSR on Kori Unit 1 can be also applied to PSR on other plants.

  • PDF

The Development of Swivel Unit for Spot Welding Robots (스폿용접 로봇용 스위블 유닛의 개발)

  • Kim, Yong-Seok;Park, Sung-Ho;Yang, Soon-Young
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.17 no.4
    • /
    • pp.119-125
    • /
    • 2008
  • A new type of swivel unit is suggested in order to complement weak points of the existing. This new type of Swivel unit is developed by adopting a spring type cable which has elasticity and restoring force. To minimize the troubles in the process of manufacturing during operating the new type system, strength analysis and the check of interference between parts are accomplished with CATIA. The check of rotating performance is also carried out to determine the diameter and length of spring type cable by SimDesigner motion analysis. Swivel unit used in the robot spot welding is developed with spring type cable and its usefulness in the industrial field is verified through experiments. This system has been registered for patent.

Testing for a unit root in an AR(p) signal observed with MA(q) noise when the MA parameters are unknown

  • Jeong, Dong-bin;Sahadeb Sarkar
    • Journal of the Korean Statistical Society
    • /
    • v.27 no.2
    • /
    • pp.165-187
    • /
    • 1998
  • Shin and Sarkar (1993, 1994) studied the problem of testing for a unit root in an AR(p) signal observed with MA(q) noise when the MA parameters are known. In this paper we consider the case when the MA parameters are unknown and to be estimated. Test statistics are defined using unit root parameter estimates based on three different estimation methods of Hannan and Rissanen (1982), Kohn (1979) and Shin and Sarkar (1995). An AR(p) process contaminated by MA(q) noise is a .estricted ARMA model, for which Shin and Sarkar (1995) derived an easy-to-compute Newton- Raphson estimator The two-stage estimation p.ocedu.e of Hannan and Rissanen (1982) is used to compute initial parameter estimates in implementing the iterative estimation methods of both Shin and Sarkar (1995) and Kohn (1979). In a simulation study we compare the relative performance of these unit root tests with respect to both size and power for p=q=1.

  • PDF

An optimal continuous type investment policy for the surplus in a risk model

  • Choi, Seung Kyoung;Lee, Eui Yong
    • Communications for Statistical Applications and Methods
    • /
    • v.25 no.1
    • /
    • pp.91-97
    • /
    • 2018
  • In this paper, we show that there exists an optimal investment policy for the surplus in a risk model, in which the surplus is continuously invested to other business at a constant rate a > 0, whenever the level of the surplus exceeds a given threshold V > 0. We assign, to the risk model, two costs, the penalty per unit time while the level of the surplus being under V > 0 and the opportunity cost per unit time by keeping a unit amount of the surplus. After calculating the long-run average cost per unit time, we show that there exists an optimal investment rate $a^*$>0 which minimizes the long-run average cost per unit time, when the claim amount follows an exponential distribution.

A Method to Model Convergent Services (융합서비스의 모델링 방법)

  • Han, Young-Seok;Oh, Chang-Kuen
    • Journal of Information Technology Services
    • /
    • v.8 no.3
    • /
    • pp.223-232
    • /
    • 2009
  • The most popular convergent services are being made mostly out of IT related services and devices. To help understand the underlying principles making convergent services the paper suggests a logical view of converging process. A service is assumed to consist of unit services that can be used in algorithmic operations to form a new convergent service. Convergence operations for a couple of unit services are typed according to whether the unit services are modified. Internal convergence leads to a new service from a combination of sub units of the two unit services. External convergences do not alter original unit services but simply combine them to form a new service. The paper also suggests several measurements to evaluate the convergent services with respect to the existing services used to create the new convergent service.

APC Technique and Fault Detection and Classification System in Semiconductor Manufacturing Process (반도체 공정에서의 APC 기법 및 이상감지 및 분류 시스템)

  • Ha, Dae-Geun;Koo, Jun-Mo;Park, Dam-Dae;Han, Chong-Hun
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.21 no.9
    • /
    • pp.875-880
    • /
    • 2015
  • Traditional semiconductor process control has been performed through statistical process control techniques in a constant process-recipe conditions. However, the complexity of the interior of the etching apparatus plasma physics, quantitative modeling of process conditions due to the many difficult features constraints apply simple SISO control scheme. The introduction of the Advanced Process Control (APC) as a way to overcome the limits has been using the APC process control methodology run-to-run, wafer-to-wafer, or the yield of the semiconductor manufacturing process to the real-time process control, performance, it is possible to improve production. In addition, it is possible to establish a hierarchical structure of the process control made by the process control unit and associated algorithms and etching apparatus, the process unit, the overall process. In this study, the research focused on the methodology and monitoring improvements in performance needed to consider the process management of future developments in the semiconductor manufacturing process in accordance with the age of the APC analysis in real applications of the semiconductor manufacturing process and process fault diagnosis and control techniques in progress.