• Title/Summary/Keyword: Unit Power Factor

Search Result 252, Processing Time 0.027 seconds

An Application of the Enrichment Zoning Concept to $17\times{17}$ KOFA ($17\times{17}$ 국산 핵연료에의 다중농축도 개념 적용)

  • Kim, K.S.;Kim, J.H.;Zee, S.K.;Song, J.W.
    • Nuclear Engineering and Technology
    • /
    • v.26 no.3
    • /
    • pp.337-344
    • /
    • 1994
  • Enthalpy rise hot channel factor($F_{\Delta{H}}$$^{N}$) is one of the most limiting constraints in determining the fuel loading pattern(LP) for PWR's. In order to enhance the LP design flexibility without any changes of not only basic fuel specifications but also Technical Specifications and Operation Procedures, we apply the enrichment zoning concept to Westinghouse designed PWR's to flatten the rod power distributions within the fuel assembly and thus to reduce $F_{\Delta{H}}$$^{N}$. Enrichment zoning is described that each assembly consists of two different enrichment fuels ; the lower enriched fuels are located in positions which are expected to have the higher rod power and vice versa for the higher enriched fuels. As a result of unit assembly calculations to flatten the rod power distribution within the assembly, the appropriate enrichment difference is found to be 0.3~0.4w/o. Through core depletion calculations for the 18-month cycle of Kori Unit 4, the $F_{\Delta{H}}$$^{N}$ behavior in core with the enrichment zoning concept is investigated. A comparison with the reference case without the enrichment zoning results in a reduction in $F_{\Delta{H}}$$^{N}$ of approximately 1.5%.TEX>H/$^{N}$ of approximately 1.5%.

  • PDF

An Economic Analysis of the Effluent Heat Supply from Thermal Power Plant to the Farm Facility House (화력발전소 온배수열 활용 시설하우스 열공급 모형 경제성분석 연구)

  • Um, Byung Hwan;Ahn, Cha Su
    • Korean Chemical Engineering Research
    • /
    • v.56 no.1
    • /
    • pp.6-13
    • /
    • 2018
  • Utilizing the heat of cooling water discharge of coal-fired power plant, pipeline investment costs for businesses that supply heat to agricultural facilities near power plants increase in proportion to installation distance. On one hand, the distance from the power plant is a factor that brings difficulties to secure economic efficiency. On the other, if the installation distance is short, there is a problem of securing the heating demands, facility houses, which causes economical efficiency to suffer. In this study, the economic efficiency of 1km length of standard heat pipeline was evaluated. The sensitivity of the heat pipe to the new length variation was analyzed at the level of government subsidy, amount of heating demand and the incremental rate of pipeline with additional government subsidy. As a result of the analysis, it was estimated that NPV 131 million won and IRR 15.73%. The sensitivity analysis showed that NPV was negative when the length of heat pipe facility exceeded 2.6 km. If the government supports 50% of the initial investment, the efficiency is secured within the estimated length of 5.3 km, and if it supports 80%, the length increases within 11.4 km. If the heat demand is reduced to less than 62% at the new length of the standard heat pipe, it is expected economic efficiency is not obtained. If the ratio of government subsidies to initial investment increases, the elasticity of the new bloc will increase, and the fixed investment, which is the cost of capital investment for one unit of heating demand, will decrease. This would result in a reduction in the cost of production per unit, and it would be possible to supply heat at a cheaper price level to the facility farming. Government subsidies will result in the increased economic availability of hot plumbing facilities and additional efficiencies due to increased demand. The greater government subsidies to initial investment, the less farms cost due to the decrease in the price per unit. The results of the study are significant in terms of the economic evaluation of the effectiveness of the government subsidy for the thermal power plant heat utilization project. The implication can be applied to any related pilot to come.

Inactivation of Ralstonia Solanacearum Using Aquatic Plasma Process (수중 Plasma 공정을 이용한 Ralstonia Solanacearum 불활성화)

  • Back, Sang-Eun;Kim, Dong-Seog;Park, Young-Seek
    • Journal of Environmental Science International
    • /
    • v.21 no.7
    • /
    • pp.797-804
    • /
    • 2012
  • A dielectric barrier discharge (DBD) plasma reactor was investigated for the inactivation of Ralstonia Solanacearum which causes bacterial wilt in aquiculture. The DBD plasma reactor of this study was divided into power supply unit, gas supply unit and plasma reactor. The plasma reactor consisted of a quartz dielectric tube, discharge electrode (inner) and ground electrode (outer). The experimental results showed that the optimum 1st voltage, 2nd voltage, air flow rate and pH were for 100 V (1st voltage), 15 kV (2nd voltage), 4 L/min, and pH 3, respectively. At a low 1st voltage, shoulder and tailing off phenomena was observed. The shoulder phenomenon was decreased as the increase of 1st voltage. R. Solanacearum disinfection in the lower air flow rate was showed shoulder and tailing off phenomenon because the active species generated less. Under optimum condition, shoulder and tailing off phenomenon was reduced. When the 2nd voltage was less than 7.5 kV, tailing off phenomenon was observed and this was not vanishes even though the increase of the disinfection time. The inactivation efficiency increased as the increase of air flow rate, however, the efficiency decreased when the air flow rate was above 4 L/min. R. Solanacearum disinfection at pH 3 showed somewhat higher than in pH 11. The pH effect of R. Solanacearum deactivation is less than the impact on other factor.

Characteristics of a PMOSFET Photodetector for Highly-Sensitive Active Pixel Sensor (고감도 능동픽셀센서를 위한 PMOSFET 광검출기의 특성)

  • Seo, Sang-Ho;Park, Jae-Hyoun;Lee, June-Kyoo;Wang, In-Soo;Shin, Jang-Kyoo;Jo, Young-Chang;Kim, Hoon
    • Journal of Sensor Science and Technology
    • /
    • v.12 no.4
    • /
    • pp.149-155
    • /
    • 2003
  • A PMOSFET photodetector for highly-sensitive active pixel sensor(APS) is presented. This sensor uses 5V power supply and has been designed and fabricated using I-poly and 2-metal $1.5{\mu}m$ CMOS technology. The feature of a PMOSFET photodetector is that the polysilicon gate of the PMOSFET was connected to n-well, in order to increase the photo sensitivity. The designed MOS photodetector has similar $I_{DS}-V_{DS}$ characteristics with a standard MOSFET. One dimensional image sensor with 16 pixels based on the PMOSFET photodetector has also been designed and fabricated. Unit pixel of the designed sensor consists of a PMOSFET photodetector and 4 NMOSFETs. Unit pixel area is $86{\mu}m{\times}90.5{\mu}m$ and its fill factor is about 12%.

Input LC Fiter Design of Diode Rectifiers Considering Filter VA Rating Reduction (필터소자의 용량 저감을 고려한 다이오드 정류기의 입력LC필터 설계)

  • 임영철;정영국
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.12 no.1
    • /
    • pp.35-44
    • /
    • 1998
  • In this paper, input LC filter design of diode rectifiers considering filter V A rating reduction has been propoesd. It consisted of an input LC parallel resonent tank whose inductor and capacitor values are se$.$ lected so that the input filter presents an infinite impedance to harmonic input ac current component. The operation of proposed input filter has been analyzed in detail under steady state conditions. Performance evaluation and related design data have been provided on Per Unit basis for the proper implementation of diode rectification system. Finally, Detailed input and output current analysis has shown that the proposed input filter yield high quality input ac current waveforms, in particular, high input power factor values and more reliabilty which reducing the V A rating of passive components as compared to the standard type LC filter.filter.

  • PDF

Stability evaluation of a proportional valve controller for forward-reverse power shuttle control of agricultural tractors

  • Jeon, Hyeon-Ho;Kim, Taek-Jin;Kim, Wan-Soo;Kim, Yeon-Soo;Choi, Chang-Hyun;Kim, Yong-Hyeon;Kim, Yong-Joo
    • Korean Journal of Agricultural Science
    • /
    • v.48 no.3
    • /
    • pp.597-606
    • /
    • 2021
  • Due to the characteristics of the farmland in Korea, forward and reverse shift is the most used. The fatigue of farmers is caused by forward and reverse shifting with a manual transmission. Therefore, it is necessary to improve the convenience of forward and backward shifting. This study was a basic study on the development of a current control system for forward and reverse shifting of agricultural tractors using proportional control valves and a controller. A test bench was fabricated to evaluate the current control accuracy of the control system, and the stability of the controller was evaluated through CPU (central processing unit) load measurements. A controller was selected to evaluate the stability of the proportional valve controller. The stability evaluation was performed by comparing and analyzing the command current of the controller and the actual current measured. The command current was measured using a CAN (controller area network) communication device and DAQ (data acquisition). The actual current was measured with a current probe and an oscilloscope. The control system and stability evaluation was performed by measuring the CPU load on the controller during control operations. The average load factor was 12.27%, and when 5 tasks were applied, it was shown to be 70.65%. This figure was lower than the CPU limit of 74.34%, when 5 tasks were applied and was judged to be a stable system.

Development of Door Control Unit for the Electric Plug-in Door of Subway Train (전동차 전기식 플러그도어 출입문 제어 장치 개발)

  • Joung, Eui-Jin
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.48 no.4
    • /
    • pp.47-53
    • /
    • 2011
  • The Electric Multiple Unit (EMU) has many types of door system such as sliding door, plug door etc.al. according to customer's requirements. The sliding door is widely used in Korea but has weak point in the noise problem. In the low operation speed, the noise coming from outer side of the EMU is not an important factor. As the speed is higher than before, noise is increased and make a problem. The main cause of noise is the imperfect air tightness in the EMU. The plug door system has advantages for the noise reduction characteristic in the high speed area. We have been developing electric plug-in door. The door is controlled by Door Control Unit(DCU) following the order of Automatic Train Protection (ATP) that is a kind of train signalling system. DCU has to simultaneously open and close the doors and the operation of it is related to the passengers safety. So DCU is a safety device that is important to reliability and safety. DCU is composed of several devices of control, motor driving, Input/Output, communication and power. In this paper, we will describe the functions, characteristic, requirement, subsystem and test results of DCU used for the electric plug-in door.

Hitting Probability on the Moving Target (이동표적에 대한 적중확률)

  • Oh H.J.
    • Journal of the military operations research society of Korea
    • /
    • v.1 no.1
    • /
    • pp.111-129
    • /
    • 1975
  • U.S. Air Force Regulation 80-1 defines that a weapon system is composed of equipments, skills, and techniques, the composite of which ferns an instrument of combat. The complete weapon system includes all related facilities, equipments, materials, services, and personnels required for the operation of the system, so that the instrument of combat can be considered as a self-sufficient unit of striking power in its intended operational environment. Effectiveness of a weapon system can be expressed as a function of its liability, reliability and performance capability. Among these attributes which influence the weapon effectiveness, performance capability is considered to be the most critical factor for many weapon systems. In order to illustrate the application of the methodology of performance capability, a specific ease study on the effectiveness of Vulcan anti-air craft gun system is presented with special emphasis on hitting probability on moving targets, effects of artificial rounds dispersion, and several principles related to the deployment of the system. This thesis includes the thorough survey of the possibility of calculating the absolute value of hitting probability on moving targets, indicates that the effects of artificial rounds dispersion increase the value of probability only when the total number of rounds fired within fire range exceeds a certain critical number, and suggests that concentrated guns deployment is better than scattered deployment in order to obtain higher probability and lower average amount of rounds if it is assumed that the effects of counter-attack from enemy threats are not serious.

  • PDF

Factors Influencing Neonate Pain Management Performed by Nurses (간호사의 신생아 통증관리 수행에 영향을 미치는 요인)

  • Noh, In-Suk;Oh, Jin-A
    • Child Health Nursing Research
    • /
    • v.17 no.3
    • /
    • pp.190-197
    • /
    • 2011
  • Purpose: The purpose of this study was to identify factors influencing neonatal pain management by nurses in order to provide evidence-based data for the development of more efficient neonatal pain care programs. Methods: This study used a descriptive research design to survey 204 registered nurses working in neonatal intensive care units and nurseries in Busan. Data collection was done from July to September 2010. General knowledge of pain and pain scale, pain intervention, neonatal pain management, and barriers to pain management were measured. Data were analyzed using stepwise multiple regression with SPSS 17.0. Results: it was found that among the factors affecting neonatal pain management by nurses, the unit where the nurse worked was the most important influential factor, followed by knowledge of pain management, education level, and barriers from medical personnel in that order. The explanatory power of these four variables accounted for 42.0% of neonatal pain management. Conclusion: Study results indicate that it is necessary to develop education programs to increase knowledge of neonatal pain management for nurses caring for neonates. Also, plans for reduction of obstacle factors in medical personnel should be prepared.

A Voltage Control Method based on Constants of Four Terminals Network Modeling of Distribution Networks

  • Yang, Xia;Lim, Il-Hyung;Choi, Myeon-Song;Lee, Seung-Jae;Kim, Tae-Wan
    • Journal of Electrical Engineering and Technology
    • /
    • v.3 no.3
    • /
    • pp.354-362
    • /
    • 2008
  • In this paper, a new algorithm of optimal voltage control is proposed for the Distribution Automation System (DAS) based on constants of four terminal network modeling. In the proposed method, the voltage profiles along feeders are estimated from the measurement of the current and power factor by a Feeder Remote Terminal Unit (FRTU) installed at each node. Whenever the voltage profile violates the restriction, the voltage control strategy is applied to keep the voltage levels along the feeders within the pre-specified range through the modification and coordination of the transformer under-load tap changers (ULTC), step voltage regulator (SVR), as well as shunt condenser. In the case studies, the estimation and control of the voltages have been testified in a radial distribution system with 11 nodes.