• Title/Summary/Keyword: Unit Power Factor

Search Result 251, Processing Time 0.021 seconds

Evaluation of unsaturated soil slope stability by incorporating soil-water characteristic curve

  • Zhai, Qian;Tian, Gang;Ye, Weimin;Rahardjo, Harianto;Dai, Guoliang;Wang, Shijun
    • Geomechanics and Engineering
    • /
    • v.28 no.6
    • /
    • pp.637-644
    • /
    • 2022
  • Loess soils are unsaturated and widely distributed in the northwest zone in China. Many steep slope of unsaturated are observed are observed to be naturally stable. However, a low factor of safety (FoS) for these slopes would be computed from the slope stability analysis following local code practices. It seems that the analyzed results following the local code practices do not agree with the real condition as observed in the field. It is commonly known that soil suction plays an important role in slope stability due to a higher shear strength of the unsaturated soil as compared with that of the saturated soil. In this paper, it is observed that the computed FoS can also be affected by unsaturated unit weight of the soil. However, the effect of unsaturated unit weight of the soil on the slope stability is commonly ignored in engineering practice. Therefore, both the effects of shear strength and unit weight of the unsaturated soil on the computed FoS of unsaturated soil slope are investigated in this study. It is observed that the unsaturated unit weight of soil on the computed FoS increases with increase in slope angle. It is also observed that the effects of the unsaturated shear strength and unsaturated unit weight on the computed FoS are more significant than the effect of 3D analyses compared to the 2D analyses on the FoS.

A Study on Powering Characteristic on Speed Variation of Propulsion System of Prototype 8200 Electric Locomotive (축소형 8200호대 전기기관차 추진시스템의 속도변화에 따른 역행특성 연구)

  • Jung, No-Geon;Chang, Chin-Young;Yun, Cha-Jung;Kim, Jae-Moon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.10
    • /
    • pp.1467-1472
    • /
    • 2014
  • This paper study on powering characteristic on speed variation of propulsion system of prototype 8200 electric locomotive propulsion system through simulation modeling. For this purpose, it being applied in the field of railway IGBT (Insulated Gate Bipolar Transistor) elements are used. Converter was performed PLL (Phase-Locked Loop) control method that is used to control the phase and output voltage, and the inverter was carried an indirect vector control method to control the speed of traction motor. The results of simulation by modeling and experimental unit, we was confirmed that converter is controlled a unity power factor and output voltage by reference voltage. Also traction motor was controlled by indirect vector control and SVPWM inverter switching method very well.

DNBR Sensitivities to Variations in PWR Operating Parameters (가압경수로의 운전변수 변화에 대한 DNBR의 민감도)

  • Hyun Koon Kim;Ki In Han
    • Nuclear Engineering and Technology
    • /
    • v.15 no.4
    • /
    • pp.236-247
    • /
    • 1983
  • Analyzed are the the DNBR(Departure from Nucleate Boiling Ratio) sensitivities to variations in various PWR operating parameters utilizing the Korea Nuclear Unit 1(KNU-1) design and operating data. Studied parameters in the analysis are core power level, system pressure, core inlet flow rate, core inlet temperature, enthalpy rise hot channel factor, and axial power peaking factor and axial offset. The calculations are performed using the steady state and transient thermal-hydraulics computer program, COBRA-IV-K, which is the revised version of COBRA-IV-i that has been adapted, partially modified and verified at KAERI. A reference case is established based on the design and operating condition of the KNU-1 reactor core, and this provides a basis for the subsequent sensitivity analysis. From the calculation results it is concluded that the most sensitive parameter in the DNBR thermal design is the coolant core inlet temperature while the axial power peaking factor is the least sensitive.

  • PDF

Development of the Numerical Guide for Cost-Benefit Analysis of Occupational Radiation Exposure In the Korean Next Generation Reactor

  • Sohn, Ki-Yoon;Kang, Chang-Sun
    • Nuclear Engineering and Technology
    • /
    • v.29 no.1
    • /
    • pp.78-84
    • /
    • 1997
  • The specific purpose of this study is to develop the numerical guide for the cost-benefit analysis of ORE ($/person-Sv reduction) to meet the criterion of ALARA in the design stage of the KNGR. In deriving the guide, the risk factor which is defined by the risk to unit collective radiation exposure dose (deaths/person-Sv) and the monetary value of human life ($/death) are required. The risk factor has been estimated from various clinical data accumulated for a number of years and continuously modified. And the monetary value of human life is usually quantified using the human capital approach. In this study, the risk to radiation exposure perceived by a group of people is investigated through an extensive poll survey conducted among university students in order to modify the existing risk factor for radiation exposure. And in evaluating the monetary value of human life, the QOL factor is introduced in order to incorporate the degree of public welfare or quality of life. As a result of study, a value within the range of 151, 000~172, 000 dollars per person-Sv reduction is recommended as the appropriate interim numerical guide for cost-benefit analysis of ORE to meet the criterion of ALARA in the design stage of the KNGR. A poll survey was also conducted in order to see whether the public acceptance cost of nuclear power should be incorporated in developing the guide, and the result of study shooed that such a cost does not need to be considered.

  • PDF

Mismatch-tolerant Capacitor Array Structure for Junction-splitting SAR Analog-to-digital Conversion

  • Lee, Youngjoo;Oh, Taehyoun;Park, In-Cheol
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.17 no.3
    • /
    • pp.387-400
    • /
    • 2017
  • A new junction-splitting based SAR ADC with a redundant searching capacitor array structure in $0.13{\mu}m$ CMOS process to alleviate capacitor mismatch effects, is presented. The normalized average power has a factor of 0.35 to the conventional SAR ADC at 10-bit conversion accuracy. Statistical experiments show the number of missing codes resulting from the mismatch reduces by 95% for 3% unit-capacitor mismatch ratio, while keeping the conversion energy to that of the conventional JS capacitor array.

A Study on the Optimum Design Flowrate for Tunnel-Type Small Hydro Power Plants

  • Lee, Chul-Hyung;Park, Wan-Soon
    • Korean Journal of Hydrosciences
    • /
    • v.3
    • /
    • pp.81-96
    • /
    • 1992
  • This study represents the methodology for feasibility analysis of small hydro power SHP plant. Cumulative density function of Weibull distribution and Thiessen method were adopted to decide flow duration curve at SHP candidate site. The perfomance prediction model and construction cost estimation model for tunnel-type SHP plant were developed. Eight tunnel -type SHP candidate sites existing on Han-river were selected and surveyed for actual site reconnaissance. The performance characteristics and economical feasibility for these sites were analyzed by using developed models. As a result, it was found that the optimum design flowrate with the lowest unit generation cost for tunel-type SHP candidate site were the flowrate concerming with between 20% and 30% of time ratio on the flow duration curve. Additionally, primary design specifications such as design flowrate, effective head, capacity, annual averageload factor, annual electricity production were estimated and discussed for eight surveyed SHP candidate sites.

  • PDF

Project Management based Analysis for the Enterprise 6 Sigma Success Factors (프로젝트 경영관점에서의 전사 6 시그마 성공요인 분석)

  • Mhun, Young-Soo;Bae, Suk-Joo
    • Journal of Applied Reliability
    • /
    • v.11 no.1
    • /
    • pp.59-81
    • /
    • 2011
  • Six Sigma has been disseminated into a variety of areas. It is believed that a stepwise understanding of Six Sigma's DMAIC is required for successes of unit projects. Meanwhile, infra-structure factors, such as leadership, organization, personnel management, educational system, etc., are also important to safely implant the Six Sigma into the whole enterprise and to thoroughly create the culture of innovation and enterprise. Careful analysis of those elements makes it possible to draw common connection between Project Management and the Six Sigma. This study drives the success elements for the successful adoption of the Six Sigma in the Korea Western Power Co., Ltd., of which management was evaluated as one of the tops based on the results of 2007 Management Innovation Assessment and arranges the similarity of like this factor and Enterprise Project Management. The results of this study are expected to provide a useful guideline for the adoption of the Six Sigma in whole company level.

A study on the Development and Field Application of Passive Filter for Harmonic Suppression (고조파 억제용 수동필터의 현장 적용화 연구)

  • Park, H.J.;Kang, C.S.;Lee, H.G.
    • Proceedings of the KIEE Conference
    • /
    • 1999.11b
    • /
    • pp.89-91
    • /
    • 1999
  • The use of electronic power unit essentially result in serious problems by harmonics. To reduce the effect by harmonics, we propose passive filter system which can control each harmonic filters individually. So, additional devices to detect and analyze harmonics were installed to filter system. According to measured data in the field, we calculated the values of filter components and verified them by computer simulation. After installation of filter system in the field, we could reduce harmonics and improve power factor.

  • PDF

The Study for Allowable Capacity of New Distributed Generation for Composite Distribution System Interconnected Distributed Generation (분산전원이 연계된 복합배전개통에 신규분산전원연계시 신규분산전원 도입량에 관한 연구)

  • Jung, Seung-Bock;Kim, Jae-Chul;Moon, Jong-Fil;Choi, Jun-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2002.11b
    • /
    • pp.277-279
    • /
    • 2002
  • Recently, power requirement has been increasing. But the large generation unit is hardly installed because of economic and environment problem. Therefore, the concern for DG(distributed generation) is growing. Present, allowable interconnection capacity of DG for composite distributed generation is studied. In this paper, it is studied that the new interconnection capacity of DG for composite distribution system interconnected DG. We study new allowable interconnection capacity by power factor and placement. We study SERV(sending end reference voltage) variation and allowable interconnection capacity interconnected new DG.

  • PDF

An Experimental Evaluation for Vehicle Road Noise on the Pattern Noise Prediction (자동차 타이어 패턴 소음 예측에 따른 차량 Road Noise 실험적 평가)

  • Wang, Sung-Joon;Lee, Keun-Soo;Kim, In-Dong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2011.04a
    • /
    • pp.361-364
    • /
    • 2011
  • In this paper, This work demonstrates a experimental evaluation for vehicle road noise NVH performance from the component-level NVH measurements of Tire. The power unit noise from tire emitted by cars has been reduced. It has been found that tire noise dominates noise produced by the power train when vehicles are driven at high constant speed. Therefore tire pattern noise is affected by pattern and vehicle and transmission loss. Tire noise mechanism is generated by several mechanisms. The sound of tire can propagate either through the air or through the structure of vehicle. Pattern noise is the result of pressure variations through the air to the interior side of vehicle. Especially, smooth asphalt, the periodicity of tread design, groove depth is important factor, which have an influence on the reduction of tire pattern noise.

  • PDF