• 제목/요약/키워드: Uninterruptible power supply

검색결과 199건 처리시간 0.029초

SMES 와 DVR을 이용한 전력계통품질 안정화 시스템 모델링 (Modeling of Power Quality Stabilization using SMES and DVR)

  • 박성열;정희열;김아롱;김재호;박민원;유인근;김석호;김해종;성기철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.2251-2252
    • /
    • 2008
  • Recently, voltage sag from sudden increasing loads is also one of the major problems inside the utility network. In order to compensate the voltage sag problem, power compensation device systems could be a good solution method. In case of voltage sag, an energy source is needed to overcome the energy loss caused by the voltage sag. Superconducting Magnetic Energy Storage (SMES) is a very promising source of this energy due to its fast response of charging and discharging time. Before constructing the power electronic delivering system for the SMES, it is necessary to simulate the system to understand its behavior. Nowadays, a lot of devices have been developed to compensate voltage sag such as Dynamic Voltage Restorer (DVR), Distribution Static Compensator (D-STATCOM) and Uninterruptible Power Supply (UPS). In this paper, focus is given only on DVR system which will be simulated by using PSCAD/EMTDC software.

  • PDF

AC 라인 리액터와 병렬 및 직렬 능동필터를 가지는 새로운 3상 라인 인터렉티브 무정전전원장치 시스템 (A Novel Three-Phase Line-Interactive UPS System having AC Line Reactor and Parallel-Series Active Filters)

  • 지준근
    • 한국산학기술학회:학술대회논문집
    • /
    • 한국산학기술학회 2004년도 춘계학술대회
    • /
    • pp.193-197
    • /
    • 2004
  • The four-leg Voltage Source Converter(VSC) can use the DC link voltage effectively by the 3-D SVPWM method. Hence the DC battery voltage can be reduced by $15\%$ in comparison to that of the conventional line-interactive UPS system. In this paper a novel line interactive Uninterruptible Power Supply(UPS) using the two four-leg VSCs is proposed. One VSC is in parallel with the ac link reactor of the power source side, and the other is in series with the load. The parallel four-leg voltage source inverter controls the three-phase line voltage independently in order to control the line reactor current indirectly. It eliminates the neutral line current and the active ripple power of the source side using the pqr theory so that unity power factor and the sinusoidal source current can be achieved even though both the source and the load voltages have zero sequence components. The series four-leg voltage source inverter compensates the line voltage and allows it to be balanced and harmonic-free. Both of the parallel and series four-leg voltage source inverters always act as independently controllable voltage sources, so that the three-phase output voltage shows a seamless transition to the backup mode. The feasibility of the proposed UPS system has been investigated and verified through computer simulations results.

  • PDF

UPS 용 3상 인버터의 LC필터단 출력전압 제어 방식 비교연구 (A Comparative Study on the Output Voltage Control Strategies of Three Phase Inverter with LC Filter for UPS)

  • 나운기;김태완;정승기
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 A
    • /
    • pp.312-317
    • /
    • 1996
  • This paper compares the output voltage control strategies of three-phase PWM inverter for uninterruptible power supply. The feedforward control, feedforward/feedback control, and decoupled feedback control in both the synchronous reference frame and the stationary reference frame are examined. In particular, it is shown that the response of the decoupled feedback controller in the synchronous reference frame can be improved by pole-zero cancellation method. It is also shown that the pole-zero cancellation method reduces to the deadbeat control, when it is implemented with digital controller.

  • PDF

내진검증(안전)을 위한 실험적 고찰을 이용한 해석 모델 개발연구 (A Test Verified Model Development Study for Seismic Qualification(Safety))

  • Uk-Hwan Sur
    • 한국안전학회지
    • /
    • 제13권4호
    • /
    • pp.286-291
    • /
    • 1998
  • 이 논문은 기기검증 중 내진검증(안전)을 위한 접근방법의 일환으로 실험을 통한 유한요소 해석 모델을 개발하였다. 이 모델은 한국원자력연구소 내의 하나로원자로 전기설비 중의 일부분인 UPS를 내진검증하기 위한 것이다. 이 시험증명용 모델은 50Hz 미만의 모든 주요 모드에서 고유진동수가 약 5%이내의 오차를 갖는 값을 예측하였다. 이 모델은 내진검증을 위한 최종 응력해석에 적합하였으며 실제 기기의 동적특성의 예측에 고 정밀도를 보여주었다.

  • PDF

DSP(TMS320F240)을 이용한 무정전 전원장치(UPS)용 PWM 인버터 제어기 설계 (PWM Inverter Controller Design for UPS(Uninterruptible Power Supply) Using a DSP(TMS320F240))

  • 장재영;이종필;최주엽;최익;이승철;유지윤
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 F
    • /
    • pp.2587-2589
    • /
    • 1999
  • In this paper, we propose a new control scheme for a PWM inverter using digital control. Digital control has various advantages in comparison with conventional analogue control. It can achieve high frequency switching of inverter and can be little influenced for temperature variations and aging of devices. This digitally-controlled PWM inverter is implemented using a Digital Signal Processor(DSPTMS320F240). The simulation results are given to verify the DSP based PWM inverter design and implementation.

  • PDF

인터넷 웹 기반 환경에서의 원격 제어 시스템 (Internet Web-Based Remote Control System Using SNMP)

  • 최주엽;오영은;전호석;송중호;최익
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 G
    • /
    • pp.3159-3161
    • /
    • 1999
  • This paper aims at developing remote control system to control and monitor distributed various devices through internet or information communication network. SNMP (Simple Network Management Protocol) and UPS (Uninterruptible Power Supply) are adopted for network management protocol and applied device, respectively. For controlling and monitoring distributed devices in real-time, Java-environment software is constructed. Also, general-use interface controller between network device and applied device is proposed. Finally, serial communication such as RS-232 and RS-485 is used between controller and applied device.

  • PDF

Single-Chip 마이크로프로세서를 이용한 UPS용 인버터의 순시전압제어 (Single-Chip Microprocessor Based Instantaneous Voltage Control of Inverter for UPS)

  • 최재호;박세현;민완기;김재식
    • 한국조명전기설비학회지:조명전기설비
    • /
    • 제6권6호
    • /
    • pp.49-57
    • /
    • 1992
  • This paper proposes a Intel 8097 single-chip microprocessor based instantaneous voltage control scheme of inverter for UPS(Uninterruptible Power Supply). There microprocessors are used to control the output voltage and frequency of the inverter, the synchronization with by-pass, and the switching of the static switch. And the status and operating conditions of UPS systems is monitored by micro processor. The inverter output voltage is controlled instantaneously with a double regulation loop so that it has very good dynamic response for the varying loads or nonlinear loads as a rectifier. And also, the software and hardware of control system is described. From simulation and experimental results, it is shown that the proposed scheme has very good performance.

  • PDF

퍼지제어기를 이용한 무정전 전원장치 (Uninterruptible Power Supply Using Fuzzy Controller)

  • 김대곤;박해암;백형래;정헌상;정수복
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 하계학술대회 논문집 A
    • /
    • pp.394-396
    • /
    • 1995
  • This paper present fuzzy control technique for the control of output voltage and improvement of UPS wave forms. General UPS has the harmonics in carrier because of output of PWM signal using analog circuit. Output voltage is controlled by selecting PWM data to improve these problems, PWM signal discreted is written on ROM and analog circuit is removed at the system and output voltage is controlled by selecting PWM data by fuzzy controller.

  • PDF

Cost-Effective APF/UPS System with Seamless Mode Transfer

  • Lee, Woo-Cheol
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권1호
    • /
    • pp.195-204
    • /
    • 2015
  • In this paper, the development of a cost-effective active power filter/uninterruptible power supply (APF/UPS) system with seamless mode transfer is described. The proposed scheme employs a pulse-width-modulation (PWM) voltage-source inverter and has two operational modes. First, when the source voltage is normal, the system operates as an APF, which compensates for the harmonics and power factor while boosting the DC-link voltage to be ready for the disturbance, without an additional DC charging circuit. A simple algorithm to detect the load current harmonics is also proposed. Second, when the source voltage is out of the normal range (owing to sag, swell, or outage), it operates a UPS, which controls the output voltage constantly by discharging the DC-link capacitor. Furthermore, a seamless transfer method for the single-phase inverter between the APF mode and the UPS mode is also proposed, in which an IGBT switch with diodes is used as a static bypass switch. Dissimilar to a conventional SCR switch, the IGBT switch can implement a seamless mode transfer. During the UPS operation, when the source voltage returns to the normal range, the system operates as an APF. The proposed system has good transient and steady-state response characteristics. The APF, charging circuit, and UPS systems are implemented in one inverter system. Finally, the validity of the proposed scheme is investigated with simulated and experimental results for a prototype APF/UPS system rated at 3 kVA.

플라이휠 저장 에너지를 이용한 무순단 전압보상 기능을 갖는 UPS (Flywheel Energy Storage UPS with Voltage Compensation)

  • 이기수;김중원;전태원;김인동;김흥근;이홍희;노의철
    • 전력전자학회논문지
    • /
    • 제10권3호
    • /
    • pp.241-247
    • /
    • 2005
  • 본 논문에서는 플라이휠의 저장에너지를 이용한 다이나믹 무정전 전원장치를 제안하고 동작기능을 분석하였다. 배터리를 에너지 저장요소로 사용하고 있는 기존의 무정전 전원장치에 비해 플라이휠 방식의 무정전 전원장치는 수명이 길고, 효율이 높으며, 환경공해가 거의 없으며, 크기도 작고, 특히 유지보수 비용이 현저히 작다는 장점을 갖는다. 무정전 기능뿐 아니라 전압보상 기능도 갖는 시스템에 대한 동작특성을 해석하였으며, 순간정전 후 전압이 복귀되는 시점에서의 위상변동을 신속히 추종하는 특성도 살펴보았다. 시뮬레이션과 실험을 통해서 시스템의 유용성을 검증하였다.