• 제목/요약/키워드: Uninterruptable power supply

검색결과 8건 처리시간 0.021초

Smart Power Management Using RTOS-based Uninterruptable Generator Supply

  • Lee, Chulju;Kang, Kyungtae;Noh, Dong Kun
    • 한국컴퓨터정보학회논문지
    • /
    • 제21권6호
    • /
    • pp.1-7
    • /
    • 2016
  • An uninterruptible power supply (UPS) allows small companies and domestic users to cope with power outages; but existing designs lack flexibility of control and require expensive battery maintenance, with a cost proportional to the outage compensation time. We combine a compact synchronous generator with a battery, with 10% of the capacity that would otherwise be required, to obtain a UPS with reduced maintenance costs for the same performance. Any UPS must respond immediately to a power loss, and our uninterruptible generator supply (UGS) is therefore built around real-time scheduling of its internal operations; this also makes it suitable for integration into the industrial gateway. The UGS is based on a real-time operating system, with an integrated wireless module providing connectivity to a web server, for monitoring and management, which can be performed remotely on a mobile device.

위상변환장치를 이용한 새로운 배전변압기 무정전 교체방법 (A New Replacement Method of Distribution Transformers without Outage using the Phase Converter)

  • 신동열;김숙철;윤기갑;차한주
    • 조명전기설비학회논문지
    • /
    • 제21권10호
    • /
    • pp.166-175
    • /
    • 2007
  • 전력 소비자들에 의한 전기품질 요구 수준이 날로 높아지고 있어 배전변압기 교체시 발생되는 정전에 의한 소비자들의 불편을 줄이기 위한 선진국형 무정전 배전변압기 교체방법이 요구되고 있다. 현재 시행되고 있는 주상변압기 무정전 교체공법은 변압기 이용률과 현장여건에 따라 1-2차를 고압 바이패스하는 방법이므로 작업공정이 불편하고, 편법작업에 의한 고장발생과 이에 따른 작업자 안전사고가 발생하는 문제점이 있어 새로운 무정전 교체방법이 절실히 요구되고 있다. 따라서 본 논문에서는 새로운 위상변환장치를 이용한 무정전 공법을 제안한다. 제안된 무정전 공법은 기존의 고압 바이패스 작업방법에 비해 작업공정을 줄이면서 안전하고 저렴한 방법으로 변압기 교체를 할 수 있다. 그러므로 본 논문에서 제시한 공법은 배전공사 원가 절감에 따른 전기요금 하락과 무정전 전력공급으로 국민생활에 편리함을 더하고 국가 경제 발전에 기여할 것으로 기대된다.

병렬 제어기법을 이용한 UPS 출력 전압의 개선 (The Improvement of Output Voltage of UPS Using a Parallel Control Method)

  • 成 炳 模;姜 弼 淳;朴 晟 濬;金 喆 禹
    • 전력전자학회논문지
    • /
    • 제7권2호
    • /
    • pp.158-164
    • /
    • 2002
  • 본 논문은 기존의 1차 예측 기법과 반복 제어기법을 이용하여 LC 필터와 정류 부하 등의 비선형 부하를 가지는 UPS 인버터의 출력전압 파형의 개선에 관한 연구이다. 기존의 1차 예측 기법은 정류부하에 대하여 우수한 특성을 가지므로 출력전류의 예측에 적합하나 정류 부하와 같은 비선형적인 부하의 정상 상태 오차를 보상하기에는 충분하지 못한 단점을 가진다. 따라서, 정상상태 오차를 최소화 할 수 있는 반복제어 기법을 적용하여 UPS 출력전압을 개선시키고자 한다. 제안된 제어기법에 대한 타당성을 시뮬레이션으로 검증하고, 이를 바탕으로 LC 필터를 가지는 3 kVA, 60 Hz UPS시스템을 제작하여 실험으로 검증한다

Improved Switching Frequency in Delta Modulated Inverter for UPS Applications

  • Sodaban, C.;Tipsuwanporn, V.;Thepsatorn, P.;Piyarat, W.;Witheephanich, K.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2004년도 ICCAS
    • /
    • pp.986-989
    • /
    • 2004
  • The concept and results of a simple constant switching frequency delta modulation scheme suitable for DC-AC power conversion in uninterruptable power supply (UPS) applications are presented. Unlike the traditional delta modulation scheme, the scheme has a well defined harmonic spectrum, resulting in a simple filter design and reduced radio interference.

  • PDF

비정상 과도상태에서의 해군 전투체계 UPS 개선 (Improvement of Naval Combat System UPS under Abnormal Transients)

  • 김성후;최한고
    • 융합신호처리학회논문지
    • /
    • 제19권3호
    • /
    • pp.97-103
    • /
    • 2018
  • 본 논문에서는 비정상적인 과도상태에서의 개선된 해상 전투체계 UPS(Uninterruptable Power Supply) 시스템을 다룬다. 기존에는 일시적인 과전압 및 과전류에 대응하기 위하여 서미스터와 바리스터 소자를 사용하고 있지만 시스템 운용 중에 발생하는 비정상 과도전압에는 취약하므로 UPS가 비가용 상태로 되는 경우가 빈번히 발생하였다. 이를 극복하고 UPS 시스템을 보호하기 위하여 본 논문에서는 초기 입력전원 및 운용 중에 발생되는 비정상 과도전압을 감지한 입력 전원 차단회로, 전원제어 시퀀스 개선, 그리고 인버터 및 CPU 오동작 방지 방법 등을 제안한다. 제안된 방법으로 UPS 구현된 시스템은 Programmable AC/DC 발생기를 이용하여 입력전원 가변 시험을 통하여 시뮬레이션을 수행하였으며, 최종적으로 해상 전투체계의 다기능콘솔에 장착하여 현장시험을 통하여 신뢰성과 안정성을 검증하였다.

능동전력필터기능을 갖는 UPS에 관한 연구 (A Study on UPS with Active Power Filter Function)

  • 박인석;이정준;성낙규;오봉환;김성남;한경희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 F
    • /
    • pp.2178-2180
    • /
    • 1998
  • Recently, for increasing consumed power and informational society, confidence of power supply is demanded. Beside, owing to most of these loads are nonlonear, utility line is polluted by these components, therefore, it is demanded compensation of harmonic current. In times past, special order of harmonic current is only compensated by passive filter, but active power filter can compensate whole harmonic current. Therefore, this paper propose uninterruptable power supply(UPS) with performance of active power filter.

  • PDF

Stability and Performance Investigations of Model Predictive Controlled Active-Front-End (AFE) Rectifiers for Energy Storage Systems

  • Akter, Md. Parvez;Mekhilef, Saad;Tan, Nadia Mei Lin;Akagi, Hirofumi
    • Journal of Power Electronics
    • /
    • 제15권1호
    • /
    • pp.202-215
    • /
    • 2015
  • This paper investigates the stability and performance of model predictive controlled active-front-end (AFE) rectifiers for energy storage systems, which has been increasingly applied in power distribution sectors and in renewable energy sources to ensure an uninterruptable power supply. The model predictive control (MPC) algorithm utilizes the discrete behavior of power converters to determine appropriate switching states by defining a cost function. The stability of the MPC algorithm is analyzed with the discrete z-domain response and the nonlinear simulation model. The results confirms that the control method of the active-front-end (AFE) rectifier is stable, and that is operates with an infinite gain margin and a very fast dynamic response. Moreover, the performance of the MPC controlled AFE rectifier is verified with a 3.0 kW experimental system. This shows that the MPC controlled AFE rectifier operates with a unity power factor, an acceptable THD (4.0 %) level for the input current and a very low DC voltage ripple. Finally, an efficiency comparison is performed between the MPC and the VOC-based PWM controllers for AFE rectifiers. This comparison demonstrates the effectiveness of the MPC controller.

Dynamic Analysis and Controller Design for Standalone Operation of Photovoltaic Power Conditioners with Energy Storage

  • Park, Sun-Jae;Shin, Jong-Hyun;Park, Joung-Hu;Jeon, Hee-Jong
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권6호
    • /
    • pp.2004-2012
    • /
    • 2014
  • Energy storage devices are necessary to obtain stable utilization of renewable energy sources. When black-out occurs, distributed renewable power sources with energy storage devices can operate under standalone mode as uninterruptable power supply. This paper proposes a dynamic response analysis with small-signal modeling for the standalone operation of a photovoltaic power generation system that includes a bidirectional charger/discharger with a battery. Furthermore, it proposes a DC-link voltage controller design of the entire power conditioning system, using the storage current under standalone operation. The purpose of this controller is to guarantee the stable operation of the renewable source and the storage subsystem, with the power conversion of a very efficient bypass-type PCS. This paper presents the operating principle and design guidelines of the proposed scheme, along with performance analysis and simulation. Finally, a hardware prototype of 1-kW power conditioning system with an energy storage device is implemented, for experimental verification of the proposed converter system.