Nowadays, the power quality issue becomes very important in the electric distribution system. Especially, when a distribution transformer is replaced, the customers who are supplied electricity from the transformer feel inconvenience due to electric outage. Therefore, an advanced method for the distribution transformer replacement without outage is strongly required. The conventional method is the primary-secondary high voltage bypass method according to the transformer utilization factor and the field condition. But it is inconvenient and has some problems such as breakdown and security troubles of the workers according to the unauthorized and temporary work. Therefore, the new scheme for the replacement with uninterruptable power supply is demanded. This paper proposes the new replacement method using the phase converter. The proposed method can reduces the process of replacement work and also ensures worker's safety. Therefore, the method is reasonable in comparison with the conventional method. The proposed method is able to contribute the national economy growth and elevate the convenience of national life by uninterruptable power supply.
Keywords
The distribution transformer replacement with uninterruptable power supply; The phase converter;
Citations & Related Records
연도 인용수 순위
  • Reference
1 한전 배전처장, '무정전 배전공법 운영절차서', 한전 배전처,2003
2 박중신 외2, '배전실무 III', 한전 중앙교육원, pp. 327-343. 1997
3 송일근 외1, '배전선로의 무정전공법 개발 연구', 한전전럭연구원, 1995
4 문수덕 외3, '무정전공법(기초과정)', 한전 중앙교육원, 2001
5 한전 중앙교육원장, '무정전공법 II', 한전 중앙교육윈, 2001