• Title/Summary/Keyword: Uniform sample

Search Result 331, Processing Time 0.024 seconds

Development of Functional Uniform for Caregivers (간병인을 위한 기능적 유니폼 개발 -노인의료복지시설 간병인을 대상으로-)

  • Lee, Eun-Young;Choi, Hei-Sun;Kim, Eun-Kyong
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.31 no.5 s.164
    • /
    • pp.788-800
    • /
    • 2007
  • The purpose of this study was to develop a caregiver's uniform that is appropriate for nursing and to improve movement adaptability as well as having a pleasing appearance. Based on the results of preliminary study, I investigated the inconvenience and problems with the existing uniforms and made a sample uniform taking into consideration the design, the material, and the pattern. We carried out a sensory assessment and quantitative assessment in order to compare the sample uniform with existing uniforms. Following are the results of this research. The top is a short-sleeved blouse with a round neckline having no collar and with armpit gussets. The armpit gussets are semicircles and the inverted pleats in the back are an improvement designed for activity. The pants are long reaching to the ankles with elastic in the waist so that the waist measurement may be adjusted. The length of the pants can be adjusted with strings and the pants have a funnel-shaped pocket for adjustment of length. We used a mix of polyurethane and polyester for the outer cloth of the uniform in order to improve activity function and used $Coolever^{TM}$, the sanitary textile that absorbs moisture well and dries in a short time, for gussets in the armpits, which is the heavy sweat area. The appearance assessment and movement adaptability assessment were performed with 5 subjects and 9 experts. For the results of the assessment, the sample uniform was appraised to be better than the existing uniforms in every item of an appearance comparison assessment except for the neckline assessment by the experts. As for the assessment of movement appropriateness and wearing assessment, the same subjects were used for analysis. As the results of the assessment, the sample uniform was rated higher than the existing uniforms in movement adaptability and pleasing appearance.

Ergonomic Design of Working Uniform for the Aircraft Mechanics (항공정비복 인간공학적 디자인 개발)

  • Lim, Hyun-Ju;Choi, Hei-Sun;Lee, Kyung-Mi;Kim, Soo-A
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.32 no.5
    • /
    • pp.681-691
    • /
    • 2008
  • Taking into consideration both the inconveniences reported with current working uniform for the aircraft mechanics and the subjects' requirements mentioned in preceded survey, the researchers designed an ergonomic sample garments with improved motional flexibility and comfort. To improve motional flexibility, extra folds were added to the back of the garments to allow for ease of motion of limbs, so that the material would not be drawn up by the motion of the arms. Darts were added to the elbow, hip, the knee. Furthermore, by increasing the length of the waist centerline, the hip region would not be drawn up. For improved comfort, $CoolMax^{(R)}$ was used as lining material for the armpit and back region to discharge swear promptly. Subjects and panels were asked to evaluate the sample garment that followed an ergonomic design and pattern. According to the results, the sample garment was evaluated more highly than the existing working uniform in appearance and motional flexibility. The field tests by three aircraft mechanics working in the Office of Forestry were also demonstrated that the sample garment was advanced in terms of motional flexibility and comfort.

Blow Characteristics in Extrusion Blow Molding for Operational Conditions (압출 블로우 성형에서 성형조건에 따른 성형특성)

  • Jun Jae Hoo;Pae Youlee;Lyu Min-Young
    • Transactions of Materials Processing
    • /
    • v.14 no.3 s.75
    • /
    • pp.233-238
    • /
    • 2005
  • Blow molding is divided into three categories, injection stretch blow molding, injection blow molding, and extrusion or direct blow molding. Extrusion blow molding has been studied experimentally to characterize the blowing behavior of parison. Blow conditions such as blowing temperature and cooling time were the experimental variables in this blowing experiment. Wall thickness of the lower part of blow molded sample was thicker than that of the upper part because of the sagging of parison during extrusion process. As temperature increases the wall thickness and the weight of blow molded sample decreased. No thickness variations in the blowing sample were observed according to the cooling time. The lower part of the sample showed high degree of crystallinity compare with the upper part of the sample. Thus the lower part of the sample was strong mechanically and structurally. It was recognized that the uniform wall thickness could not be obtained by only controlling the operational conditions. Parison variator should be introduced to get uniform wall thickness of parison and subsequently produce uniform wall thickness of blow molded product.

Estimates for parameter changes in a uniform model with a generalized uniform outlier

  • Lee, Chang-Soo;Chang, Chu-Seock;Park, Yang-Woo
    • Journal of the Korean Data and Information Science Society
    • /
    • v.21 no.3
    • /
    • pp.581-587
    • /
    • 2010
  • We shall propose several estimators for the scale parameter in a uniform distri-bution with a generalized uniform outlier when the scale parameter is a function of a known exposure level, and obtain expectations and variances for their proposed estima-tors. And we shall compare numerically efficiencies for proposed estimators of changed parameters of the scale in the small sample sizes.

Asymptotic Properties of the Stopping Times in a Certain Sequential Procedure

  • Kim, Sung-Lai
    • Journal of the Korean Statistical Society
    • /
    • v.24 no.2
    • /
    • pp.337-347
    • /
    • 1995
  • In the problem of some sequential estimation, the stopping times may be written in the form $N(c) = inf{n \geq n_0; n \geq c^2 S^2_n/\delta^2 (\bar{X}_n)}$ where ${s^2_n}$ and ${\bar{X}_n}$ are the sequences of sample variance and sample mean of the independently and identically distributed (i.i.d.) random variables with distribution $F_{\theta}(x), \theta \in \Theta$, respectively, and $\delta$ is either constant or any given positive real valued function. We obtain some asymptotic normality and asymptotic expectation of the N(c) in various limiting situations. Specially, uniform asymptotic normality and uniform asymptotic expectation of the N(c) are given.

  • PDF

Synthesis and Dielectric Properties of LaAIO3 Ceramics with Grinding Methods (분쇄방식에 따른 LaAIO3 세라믹의 합성과 유전특성)

  • 조정호;최상수;김강언;정수태;조상희
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.15 no.3
    • /
    • pp.238-243
    • /
    • 2002
  • The dielectric properties and synthesis of $LaAIO_3$ ceramics from mixtures of $La_2O_3$ and $AI(OH)_3$ via ground(planetary ball mill) and unground(wet ball mill) were investigated. The single phase $LaAIO_3$ of ground powder was formed at $1000^{\circ}C$, while that of unground powder was formed at $1300^{\circ}C$. Density and grains of ground sample showed 98% of theory density and a uniform size of 0.75\mu\textrm{m}$, respectively, However those of unground sample showed 93% and non-uniform sizes of 4-5 $\mu\textrm{m}$. Dielectric constant and temperature coefficient of capacitance ($\tau$c) of both ground and unground samples were 21~22 and +70~74 ppm$/^{\circ}C$, respectively. Dielectric loss of ground sample(0.0004) was 10 times as low as that of unground sample(0.003) due to a uniform and small gram size.

The Development of a Battle Dress Uniform Pattern Improved functionality for the Korean police SWAT units - Focused on the Development and the Fitting Evaluation of the BDU - (경찰특공대(SWAT) 작전복(BDU)의 기능성 향상을 위한 패턴개발 - 작전복 개발 및 착의평가를 중심으로 -)

  • Moon yeon-Sil;Kim Son-Hee;Kim Eun-Kyong
    • Journal of the Korean Home Economics Association
    • /
    • v.43 no.5 s.207
    • /
    • pp.235-248
    • /
    • 2005
  • The objective of the study was to design a Battle Dress Uniform(BDU with improved motional flexibility, body fit, and protectiveness to cope with the special operational environment of the subjects. For this purpose, the researcher conducted a questionnaire survey on 92 male members of Special Weapon Attack Team(SWAT units in a former study, and based on the results of the survey, made the two-piece and one- piece BDU samples to overcome the identified problems and inconveniences. The sample uniforms were designed ergonomically from five aspects. Subsequentlv, the new BDU was compared with the current operational uniform in terms of outward appearance(design and fit), motional flexibility, and suitability for field activities. The samples were evaluated by 5 SWAT members as subjects and 8 graduate school students majoring in clothing and textiles as experts. According to the results, the two-piece and one-piece samples gained higher scores than the existing operational uniform in terms of outward appearance(design and fitness) and motional flexibility, and the one-piece sample was preferred with regard to fit when worn by the subjects with their full kit for field operations. That is, the one-piece sample appeared to be more suited to the special work environment of SWAT and to be more functional in terms of ease of putting on and taking off, motional flexibility, body fit and protectiveness than the current operational uniform(two-piece type).

Analysis of Current Density Distribution and In Vitro Exposur System fot ELF Exposed Cell Experiments (ELF 전자파 피폭 세포실험을 위한 배양기의 전류밀도 분포 해석 및 In Vitro 노출장치 설계)

  • 김대근;정재승;안재목
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.12 no.1
    • /
    • pp.84-91
    • /
    • 2001
  • In in vitro cell experiments for the biological assessment of electromagnetic (EM) field, exposure system (ES) must be analyzed in terms of current density (J) and induced electric field intensity (E). Although in uniform B field, E and J in the sample medium are not distributed uniformly because of conductivity in sample dish. Thus, the precise estimation for E and J induced by uniform ELF within sample media is very important keys for successful in in vitro experiments. In this paper, we designed in vitro ELF ES with electromagnetic analysis using MATLAB simulator. Then we calculated from the measured B field to verify induced E & J distribution for random locations of cells within media in two cases of samples existence or not. ES with B field ranging from 0 to 20G consists of Helmholz coil and current generator based on the microprocessor. Also, we developed ELFES for each B field generation as uniform and non-uniform modes.

  • PDF