ENHANCEMENT OF DRYOUT HEAT FLUX IN A DEBRIS BED BY FORCED COOLANT FLOW FROM BELOW

  • Bang, Kwang-Hyun;Kim, Jong-Myung
    • Nuclear Engineering and Technology
    • /
    • 제42권3호
    • /
    • pp.297-304
    • /
    • 2010
  • In the design of advanced light water reactors (ALWRs) and in the safety assessment of currently operating nuclear power plants, it is necessary to evaluate the possibility of experiencing a degraded core accident and to develop innovative safety technologies in order to assure long-term debris cooling. The objective of this experimental study is to investigate the enhancement factors of dryout heat flux in debris beds by coolant injection from below. The experimental facility consists mainly of an induction heater, a double-wall quartz-tube test section containing a steel-particle bed and coolant injection and recovery condensing loop. A fairly uniform heating of the particle bed was achieved in the radial direction and the axial variation was within 20%. This paper reports the experimental data for 3.2 mm and 4.8 mm particle beds with a 300 mm bed height. The dryout heat density data were obtained for both the top-flooding and the forced coolant injection from below with an injection mass flux of up to $1.5\;kg/m^2s$. The dryout heat density increased as the rate of coolant injection increased. At a coolant injection mass flux of $1.0\;kg/m^2s$, the dryout heat density was ${\sim}6.5\;MW/m^3$ for the 4.8 mm particle bed and ${\sim}5.6\;MW/m^3$ for the 3.2 mm particle bed. The enhancement factors of the dryout heat density were 1.6-1.8.

보성 농업지역에서의 장기간 플럭스 특성 분석 (Long Term Flux Variation Analysis on the Boseong Paddy Field)

  • 이영태;황성은;김병택;김기훈
    • 대기
    • /
    • 제34권1호
    • /
    • pp.69-81
    • /
    • 2024
  • In this paper, Annual flux variations in the Boseong Tall Tower (BTT) from 2016 to 2020 were analyzed using data from three levels (2.5 m, 60 m, and 300 m). BTT was installed in Boseong-gun, Jeollanam-do in February 2014 and continued to conduct energy exchange observations such as CO2, sensible heat, and latent heat using the eddy covariance method until March 2023. The BTT was located in a very flat and uniform paddy field, and flux observations were conducted at four levels: 2.5 m, 60 m, 140 m, and 300 m above ground. Surface energy balance was confirmed from observed data of net radiation flux, soil heat flux, sensible heat flux, and latent heat flux. Additionally, 2.5 m height surface fluxes, which are most influenced by agricultural land, were compared with data from Local Data Assimilation and Prediction System (LDAPS) of the Korea Meteorological Administration to evaluate the accuracy of LDAPS flux data. The correlation coefficient between LDAPS flux data and observed values was 0.95 or higher. Excluding summer latent heat flux data, there was a general tendency for LDAPS data to be higher than observed values. The footprint areas estimated below 60 m height mainly covered agricultural land, and flux observations at 2.5 m and 60 m heights showed typical agricultural characteristics. In contrast, the footprint estimated at 300 m height did not show agricultural characteristics, indicating that observations at this height encompassed a wide range, including mountains, sea, and roads. The analysis results of long-term flux observations can contribute to understanding the energy and carbon dioxide fluxes in agricultural fields. Furthermore, these results can be utilized as essential data for validating and improving numerical models related to such fluxes.

수평 평활관 외측의 액막 증발에 관한 연구 (Thin Film Evaporation on Horizontal Plain Tubes)

  • 김정오;김내현;최국광
    • 태양에너지
    • /
    • 제18권4호
    • /
    • pp.49-57
    • /
    • 1998
  • In this study, thin film evaporation of water on a horizontal plain tube is experimentally investigated. At a high heat flux, boiling of water is noticed inside the film. Once boiling occurs, evaporation heat transfer coefficient increases as the heat flux increases. In the non-boiling region, however, the heat transfer coefficient remains uniform irrespective of the heat flux. In this region, the heat transfer coefficient increases as the film flow rate increases. Comparison with existing correlations is also provided.

  • PDF

완전 발달된 원형 충돌제트의 노즐 직경이 열전달에 미치는 영향 (The Effect of Nozzle Diameter on Heat Transfer to a Fully Developed Round Impinging Jet)

  • 이대희;원세열;이영민;조헌노
    • 대한기계학회논문집B
    • /
    • 제24권4호
    • /
    • pp.519-525
    • /
    • 2000
  • The effect of nozzle diameter on the local Nusselt number distributions has been investigated for an axisymmetric turbulent jet impinging on the flat plate surface. The flow at the nozzle exit has a fully developed velocity profile. A uniform heat flux boundary condition at the plate surface was created using gold film Intrex. Liquid Crystal was used to measure the plate surface temperature. The experiments were made for the jet Reynolds number (Re) 23,000, the dimensionless nozzle to surface distance (L/d) from 2 to 14, and the nozzle diameter (d) from 1.36 to 3.40 cm. The results show that the Nusselt number at and near the stagnation point increase with an increasing value of the nozzle diameter.

일정 열류속 및 온도조건하의 수직관내에서 공기의 자연대류 열전달 연구 (Natural Free Convection of Air in a Vertical Open Tube With Uniform Heat Flux and Temperature)

  • 손병진;강희영
    • 대한설비공학회지:설비저널
    • /
    • 제12권4호
    • /
    • pp.234-239
    • /
    • 1983
  • 수직관내에서 공기의 자연대류 열전달 연구가 유체의 지배방정식에 대한 이론해석과 실험에 의하여 수행되었다. 관내에서 공기의 대류열전달 특성을 조사하기 위하여 무차원 Rayleigh수가 도입되었으며, 이 Rayleigh 수와 Nusselt수 사이의 관계를 유한차분법의 수치해석과 실험으로 서로 비교하였다. 실험에서 얻은 결과와 이론치가 서로 잘 일치하고 있음을 알았으며, 또한 Nusselt와 Rayleigh수 사이의 관계식을 얻었다.

  • PDF

均一두께의 環狀흰에서 週期的 過渡應答 特性에 관한 硏究 (A Study on the Periodic Transient Response Characteristics in Annular Fin with Uniform Thickness)

  • 김광수
    • 대한기계학회논문집
    • /
    • 제12권2호
    • /
    • pp.338-348
    • /
    • 1988
  • 본 연구는 환상휜에서 휜 바탕의 온도가 조기적으로 변화할 때, 휜 바탕의 온도가 주기적으로 변화할 때, 휜 주변 뿐만 아니라 휜 선단에서의 대류현상을 고려한 과도 전열에 대한 해석이다.

원관 주위의 대류 열전달에 대한 복합 열전달 (Conjugated heat transfer on convection heat transfer from a circular tube in cross flow)

  • 이승홍;이억수;정은행
    • 설비공학논문집
    • /
    • 제10권5호
    • /
    • pp.523-534
    • /
    • 1998
  • The convection heat transfer on horizontal circular tube is studied as a conjugated heat transfer problem. With uniform heat generation in a cylindrical heater placed in a cross flow boundary condition, heat flow that is conducted along the wall of the heater creates a non-isothermal surface temperature and non-uniform heat flux distribution. In the present investigation, the effects of circumferential wall heat conduction on convection heat transfer are investigated for the case of forced convection around horizontal circular tube in cross flow of air and water. Non-dimensional conjugation parameter $ K^*$ which can be deduced from the governing energy differential equation should be used to express the effect of circumferential wall heat conduction. Two-dimensional temperature distribution$ T({\gamma,\theta})$ is presented. The influence of circumferential wall heat conduction is demonstrated on graph of local Nusselt number.

  • PDF

일정 열유속의 하부 가열면을 갖는 채널캐비티 내부유동의 PIV 계측 (PlV Measurement of Channel Cavity Flow with Bottom Heat surface of Constant Heat Flux)

  • 조대환;김진구
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제21권4호
    • /
    • pp.437-442
    • /
    • 1997
  • An experimental study was carried out in a channel cavity with square heat surface by visual¬ization equipment with Mach - Zehnder interferometer and laser apparatus. The image processing system consists of one commercial image board slit into a personal computer and 2-dimensional sheet light by Argon-Ion Laser with cylindrical lens and flow picture recording system. Instant simultaneous velocity vectors at whole field were measured by 2-D PIV system which adopted two¬frame grey-level cross correlation algorithm. Heat source was uniform heat flux(o.4W/cm$^2$, , O.8W/cm$^2$, 1.2W/cm$^2$). Obtained result showed various flow patterns such as kinetic energy distribution. Severe unsteady flow fluctuation within the cavity are remarkable and sheared mixing layer phenomena are also found at the region where inlet flow is collided with the counter-clockwise rotating main primary vortex. Photographs of Mach ~ Zehnder are also compared in terms of constant heat flux.

  • PDF

판열유속계를 이용한 복사열유속 측정 실험 (Measurement of Radiative Heat Flux Using Plate Thermometer)

  • 박원희;윤경범
    • 대한기계학회논문집B
    • /
    • 제37권1호
    • /
    • pp.95-98
    • /
    • 2013
  • 고온환경의 복사열유속을 측정하기 위하여 판열유속계를 제작하였다. 열유속은 스테인리스스틸로 제작된 판열속계 뒷면에서 측정된 온도를 이용하여 계산되어진다. 스미트-볼터계로 측정된 열유속을 기준값으로 이용하였다. 단열재로의 열손실, 판열유속계 두께방향으로의 전도 및 평판의 위치에 따라 온도가 상이하여 발생하는 열전달 등을 고려하기 위하여 전도상수를 도입하였다. 이 상수는 반발입자군집 최적화법으로 구하였다.

성층 데브리층에서의 강제대류 드라이아웃 열유속 (Forced Flow Dryout Heat Flux in a Stratified Debris Bed)

  • Cha, Jong-Hee;Chung, Moon-Ki;Jin, Yong-Suk
    • Nuclear Engineering and Technology
    • /
    • 제20권2호
    • /
    • pp.112-119
    • /
    • 1988
  • 이 연구의 목적은 가혹한 사고후 손상된 원자로심을 모의한 열이 발생하는 성충 데브리층에서의 강제대류 드라이아웃 열유속 자료를 실험 적으로 얻고자 한 것이다. 여 기서는 일정한 층의 깊이와 냉각재 유입온도 조건하에서 선정된 몇 가지 크기의 입자로 성층을 형성한 데브리층에서 주로 냉각재질량유속이 드라이아웃 열유속에 미치는 영향을 관찰하였다. 이 실험적 연구로부터 얻은 주요 결과는 다음과 같다 (1) 성층 데브리층에서의 드라이아웃 열유속은 질량유속의 증가와 더불어 증가하며 그 증가의 경향은 크기가 균일한 입자층에 대한 것과 유사하다. (2) 이론치와 실험치와의 비교에서 입자직경으로는 표면적 평균 직경을 사용하는 것이 적합하다.