• Title/Summary/Keyword: Uniform Temperature

Search Result 1,835, Processing Time 0.029 seconds

Survey on attitude and preference of the Uniform in preschool students' parents (학부모를 중심으로 한 유아원복에 대한 태도 및 선호연구)

  • You, Kyung-Sook
    • Korean Journal of Human Ecology
    • /
    • v.17 no.2
    • /
    • pp.345-353
    • /
    • 2008
  • This survey intends to understand the opinion and status on preschool students' uniform wearing for the purpose of new style development. The results from this study will serve as an activator of related industry. The merit of uniform wearing in these students was recognized primarily as: (1) students can have pride in the schools they attend; (2) they need not worry about clothes to wear every morning. The disadvantage of uniform wearing derives from: (1) students' personality is hardly expressed by uniforms; (2) difficulty in uniform selection suitable for varying weather conditions. This disadvantage felt by their parents suggests the lack of personality expression and appropriate body temperature control. The most prevalent opinion for preference and future improvement points was the consideration of physical activity in children. This indicates that they prefer uniforms rendering minimal restriction on body movements. Other Improvement points stress the activity, uniform laundering and care, convenience in on and off, insulation, colors, design and durability.

Design and Fabrication of microheaters based oil polycrystalline 3C-SiC with large uniform-temperature area for high temperature (다결정 3C-SiC 기반으로 한 넓은 범위에서 균일한 온도 분포를 갖는 초고온용 마이크로 히터 설계 및 제작)

  • Jeong, Jae-Min;Chung, Gwiy-Sang
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.06a
    • /
    • pp.214-215
    • /
    • 2009
  • This paper presents the fabrication and characteristics of microheaters, built on AlN(0.1 um)/3C-SiC(1 um) suspended membranes. Pt was used as microheater and temperature sensor materials. The results of simulated are shown that AlN/3C-SiC membrane has more large uniform-temperature area than $SiO_2$/3C-SiC membrane. Resistance of temperature sensor and power consumption of microheater were measured and calculated. Pt microheater generates the heat of about $550^{\circ}C$ at 340 mW and TCR of Pt temperature sensor is about 3188 ppm/$^{\circ}C$.

  • PDF

Internal Structure Optimization to enhance the Thermal Performance of an Air-cooled Lithium-ion Battery Pack (공냉식 리튬 이온 배터리 팩의 열 성능 향상을 위한 내부 구조 최적화)

  • Li, Quanyi;Cho, Jong-Rae
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.20 no.12
    • /
    • pp.54-64
    • /
    • 2021
  • Electric vehicles use lithium-ion battery packs as the power supply, where the batteries are connected in series or parallel. The temperature control of each battery is essential to ensure a consistent overall temperature. This study focused on reducing ohmic heating caused by batteries to realize a uniform battery temperature. The battery spacing was optimized to improve air cooling, and the tilt angle between the batteries was varied to optimize the internal structure of the batterypack. Simulations were performed to evaluate the effects of these parameters, and the results showed that the optimal scheme effectively achieved a uniform battery temperature under a constant power discharge. These findings can contribute to future research on cooling methods for battery packs.

Relaxation of Singular Stress in Adhesively Bonded Joint at High Temperature

  • Lee, Sang Soon
    • Journal of the Semiconductor & Display Technology
    • /
    • v.17 no.1
    • /
    • pp.35-39
    • /
    • 2018
  • This paper deals with the relaxation of singular stresses developed in an epoxy adhesive at high temperature. The interface stresses are analyzed using BEM. The adhesive employed in this study is an epoxy which can be cured at room temperature. The adhesive is assumed to be linearly viscoelastic. First, the distribution of the interface stresses developed in the adhesive layer under the uniform tensile stress has been calculated. The singular stress has been observed near the interface corner. Such singular stresses near the interface corner may cause epoxy layer separated from adherent. Second, the interfacial thermal stress has been investigated. The uniform temperature rise can relieve the stress level developed in the adhesive layer under the external loading, which can be viewed as an advantage of thermal loading. It is also obvious that temperature rise reduces the bonding strength of the adhesive layer. Experimental evaluation is required to assess a trade-off between the advantageous and deleterious effects of temperature.

Teachers’Attitudes toward the Middle and High School Student Uniform (중.고등학교 교복에 대한 교사들의 태도)

  • 이경자;김용숙
    • Journal of Korean Home Economics Education Association
    • /
    • v.7 no.2
    • /
    • pp.1-18
    • /
    • 1995
  • The purpose of this study was to investigate the teachers’attitudes toward the middle and high school student uniform. The questionnaire included independent variables about teacher themselves and school surroundings, and questions about teachers’attitudes toward school uniform. The participants were 316 middle and high school teachers in Chonbuk province. Means, standard deviations, frequencies, and percentages were calculated. ANOVA test was used for differences and scheffe-test was followed. The results were: 1. Teachers were content with “Students in uniform are upright and look more studentlkie.”“It’s easy to supervise students outdoors.”, and “There’s few efficiencies in coping with the temperature alternating.”, “Students in uniform hardly can reveal their originality.”and “It’s inconvenient for the students to be dynamic in uniform.” 2. Teachers in high schools and in private schools showed more positive attitudes toward uniform. And the male teachers, teachers graduated from general college, married teachers, and teachers who have a career of more than 20 years showed more positive attitudes toward uniform. More variables concerned about teacher themselves showed more significant differences than those about school surroundings. 3. Most of teachers showed positive attitudes toward uniform. The rank order of the reasons for the teacher’s positive attitudes were “Students in uniform are upright and look more studentlike.”, “It’s easy to supervise students outdoors.”, and “There’s no noticible distinction between the rich and the poor students.”The rank order of the reason for the teachers’negative at titudes were “Student in uniform could hardly reveal their originality.”, “It’s inconvenient for the student to be dynamic in uniform.”, and ”As they have to get the street clothes besides, economic burden becomes double in reality.”4. More than half of the teachers who are working at schools with uniform showed positive attitudes toward uniform. The rank order of reasons for the teachers’positive attitudes were “Students in uniform are upright and look more studentlike.”,“It’s easy to supervise students outdoors.”and “Economic burden could be decreased.”“The rank order of the reasons for the negative attitudes were “It’s inconvenient for the student to be dynamic in uniform.”, “Students in uniform could hardly reveal their originality.”, and “Students cannot feel free in mind with uniform.”5. Teachers overall showed positive attitudes toward uniform whether they work ar schools with uniform or without it.

  • PDF

Effect of Austenitizing Temperatures on Corrosion Resistance of 420J2 Stainless Steel (420J2 강의 내식성에 미치는 오스테나이트화 온도의 영향)

  • Kim, H.J.;Jung, B.H.
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.21 no.3
    • /
    • pp.150-156
    • /
    • 2008
  • The effects of austenitizing temperature in a range of $1000{\sim}1150^{\circ}C$ on the corrosion resistance in 420J2 stainless steel tempered at $150^{\circ}C$ were investigated by an electrochemical uniform corrosion test in a solution of 0.5M $H_2S0_4$. Pitting test and DL-EPR test for intergranular corrosion were carried out in a solution of 3.5% NaCl and 0.5M $H_2S0_4$ + 0.01 M KSCN respectively. In uniform corrosion test, specimens austenitized below $1100^{\circ}C$ showed similar corrosion current density and passive current density, whereas specimens austenitized at $1150^{\circ}C$ showed a little higher values. Pitting potential slightly increased with an increase of austenitizing temperature. The degree of sensitization, DOS, also slightly increased with an increase of austenitizing temperature, reaching the highest degree at $1150^{\circ}C$. It was expected that the increase of DOS was due to the larger grain size rather than the dissolved precipitates in the matrix.

Thermal System Analysis for Optimization of Torch Position in The Core Making Machine. (중자조형기의 토치위치 최적화를 위한 열계해석)

  • 한근조;안성찬;심재준;한동섭
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.587-590
    • /
    • 2000
  • The new core making method economized on core sand requested. The new method is heating core box until it reaches reasonable temperature and then spraying core sand with core binder into core box. Inner temperature distribution have to uniform in order to form core of uniform thickness. Therefore, in this study we treat of inner temperature distribution of core box in priority. First, determine proper torch number. Next, optimize the torch position to minimize the average of absolute deviation(AVEDEV) of inner temperature. The results are as followed : 1. The torch number that makes inner temperature distribution about $300^\circ{C}$ uniformly is 25. 2. When $S_H$ and $S_V$ is 0.7, the torch position is optimized and AVEDEV is 5.85.

  • PDF

EFFECT OF POROSITY ON THE TRANSIENT MHD GENERALIZED COUETTE FLOW WITH HEAT TRANSFER IN THE PRESENCE OF HEAT SOURCE AND UNIFORM SUCTION AND INJECTION

  • Attia, Hazem Ali;Ewis, Karem Mahmoud;Awad-Allah, Nabil Ahmed
    • Journal of the Korean Society for Industrial and Applied Mathematics
    • /
    • v.16 no.2
    • /
    • pp.125-135
    • /
    • 2012
  • The transient magnetohydrodynamic (MHD) generalized Couette flow with heat transfer through a porous medium of an electrically conducting, viscous, incompressible fluid bounded by two parallel insulating porous plates is studied in the presence of uniform suction and injection and a heat source considering the Hall effect. A uniform and constant pressure gradient is imposed in the axial direction and an externally applied uniform magnetic field as well as a uniform suction and injection are applied in the direction perpendicular to the plates. The two plates are kept at different but constant temperatures while the Joule and viscous dissipations are included in the energy equation. The effect of the Hall current, the porosity of the medium and the uniform suction and injection on both the velocity and temperature distributions is investigated.

Study on Thermal Pattern and Current Characteristics of an LED Street Lamp (LED 가로등의 발열 패턴 및 전류 특성에 관한 연구)

  • Kim, Hyang-Kon;Choi, Chung-Seog
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.58 no.3
    • /
    • pp.357-361
    • /
    • 2009
  • This study performed analysis on the thermal pattern and current characteristics of an LED ((Light Emitting Diode) street lamp. It did this using a TVS (Thermal Video System) to analyze the LED street lamp's thermal pattern, and measured its characteristics using an oscilloscope. The ambient temperature and humidity during the experiment were maintained at $24{\pm}2[^{\circ}C]$ and 50~60[%]. The capacity of the LED street lamp was 120[W] and nine sets of modules were arranged at uniform intervals. On one module, 24 LED lamps were arranged in a radial pattern. The analysis of the thermal diffusion pattern at the front of the LED lamp showed that the maximum surface temperature was approximately $34[^{\circ}C]$. In addition, there was almost no change in the temperature of the upper cover, and the temperature at the side showed a uniform thermal diffusion pattern. The surface temperature of the converter converting AC to DC increased to approximately $46[^{\circ}C]$. The analysis results of the thermal characteristics of one LED indicated uniform thermal characteristics for an initial eight minutes. However, the temperature at the center of the LED increased to approximately $82[^{\circ}C]$ after 12 minutes had elapsed. It can be seen from this that the temperature at the center of the LED was higher than the allowable temperature, $70[^{\circ}C]$ of the insulating material for general electrical devices. Therefore, it is necessary to design a lamp in such a way that the plastic insulating material does not come into contact with or get close to the LED lamp. The voltage of the LED lamp converted by the AC/DC converter was measured at DC 27[V] and the current was DC 13[A]. Consequently, it can be seen that in order to secure an adequate light source, it is important to supply a stable current that was greater than the current of other light sources. Therefore, appropriate radiation of heat is required to secure the stability and reliability of the system.

Study on the Partially Premixed Flames Produced by a Coflow Burner as Temperature Calibration Source (동축류 버너에서 생성된 부분 예혼합 화염을 이용한 화염 온도 측정 검정원 연구)

  • Park, Chul-Woung;Hahn, Jae-Won;Shin, Hyun-Dong
    • Journal of the Korean Society of Combustion
    • /
    • v.5 no.1
    • /
    • pp.91-98
    • /
    • 2000
  • We investigated a uniform temperature zone, produced by double flame structure of a co flow CH4/air partially premixed flame, to be used as a temperature calibration source for laser diagnostics. A broadband N2 CARS(coherent anti-Stokes Raman spectroscopy) system with a modeless laser was used for temperature measurement. When the stoichiometric ratio was 1.5, we found the uniform temperature zone in radial direction of the flame of which the averaged temperature was 2110 K with standard deviation 24 K. In the stoichiometric ratio range between 2.0 and 2.5, we found very stable temperature-varying zones in vertical direction at the center of the flame. The size of the zone was approximately 15 mm and it covered a temperature range from 300 K to 1900 K. We also suggest that this zone can be used as a calibration source for 2-D PLIF(planar laser induced flurescence) temperature measurement.

  • PDF