• 제목/요약/키워드: Underground station

검색결과 315건 처리시간 0.028초

부산광역시 지하철역 지하공간의 대기오염 특성 (Analysis of air pollution in subway area of Busan Metropolitan City)

  • 이화운;장난심;곽진;이희령;김희만
    • 한국환경과학회지
    • /
    • 제11권3호
    • /
    • pp.169-176
    • /
    • 2002
  • The purpose of this study is designed to estimate the air quality of subway stations that have the underground platforms in Pusan Metropolitan City, from September to November 2000, over seven times. The subjects include Yonsan-dong station, Somyon station, Pusan station, Nampo-dong station, and Tushil station. The samplings were conducted at three points of each station, i.e. gate, ticket gates, and platforms. The major materials for analysis were CO, NO, NO$_2$, and $O_3$. The experiment was conducted at 7:00 pm with KIMOTO HS-seven Handy sampler and Tedlar Bag of SKC INC(U.S.A). In order to more fully understand station environments, we also measured temperature at each point. The results showed that $O_3$ average concentration at Yonsan-dong station was higher than others with 38~51 ppb. The average concentration of NO was high at ticket gate and platform at Somyon station(119 ppb, 122 ppb), Nampo-dong station(102 ppb, 100 ppb). These results show that the air pollution of stations with underground shopping malls was higher than others. At Somyon station having a junction station, NO and NO$_2$ concentration level of platform-2(noncrowded) was higher than platform-1(crowded). This is most likely due to the accumulation of air pollutants and inadequate ventilation systems.

스크린도어가 설치된 대심도 지하역사의 제연 실험 I - 승강장에서의 제연의 효과 분석 (Smoke Control Experiment of a Very Deep Underground Station Where Platform Screen Doors are Installed (I) - Analysis on Smoke Control Performance on the Platform)

  • 박원희;김창용;조영민;권태순;이덕희
    • 예술인문사회 융합 멀티미디어 논문지
    • /
    • 제8권7호
    • /
    • pp.485-496
    • /
    • 2018
  • 본 논문에서는 스크린도어가 설치되어 있는 지하역사 승강장에서 화재가 발생시 승강장 환기실에 설치된 송풍기의 작동에 따른 연기거동을 실험적인 방법으로 측정하였다. 스크린도어가 닫힌 승강장에서 모의화재 발생시 승강장의 제연설비가 작동하지 않은 경우와 작동하는 경우에 제연 특성을 비교하였다. 화재연기를 모사하기 위하여 연기발생기에서 발생한 연기를 열풍기를 이용하여 가열하였다. 화재연기를 정량적으로 측정하기 위하여 연기농도계를 이용한 광투과도를 측정하였다. 스크린도어가 닫혀져있고 지하역사의 제연설비가 작동되지 않는 경우 승강장에 화재가 발생하면 연기가 승강장 내부에 축적되어 승객의 피난이 매우 어려우며, 매우 위험한 상황으로 연결될 수 있음을 확인할 수 있었다. 반면에 역사의 제연설비를 가동한 조건에서는 승강장 화재에 의해 발생한 연기가 역사의 제연설비를 통하여 외부로 빠져나가며, 대합실에서 승강장 방향으로 기류가 형성되어 승강장 승객이 대합실 방향으로 대피하는 것이 가능함을 확인할 수 있었다. 후속 논문에서는 승강장 인접부에 위치한 터널환기구를 통한 터널 제연의 병행효과에 대하여 다룰 예정이다.

대심도 지하철 승강장의 종류별 연기전파특성 비교고찰 (THE COMPARISON ON THE CHARACTERISTIC OF THE FIRE DRIVEN SMOKE-FLOW FOR THE PLATFORM TYPES IN THE DEEPLY UNDERGROUND SUBWAY STATION)

  • 김학범;장용준;이덕희;정우성;황현배
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2010년 춘계학술대회논문집
    • /
    • pp.505-507
    • /
    • 2010
  • 본 논문에서는 대심도 지하철역사의 승강장 종류에 따라 화재시 연기의 전파특성을 비교하였다. 본 연구에서 비교 대상역사로서 상대식 승강장은 서울 숭실대입구역사(47m)로, 섬식은 부산 만덕지하역사(65m)를 선정하여 각 역사에 대하여 화재전산모사를 수행하였다. 해석을 통하여 화재의 연기전파특성을 파악하였으며, 그 결과를 이용하여 각 승강장 종류별로 대심도 지하역사의 방재대책을 세우고자 한다.

  • PDF

Analysis of queuing mine-cars affecting shaft station radon concentrations in Quzhou uranium mine, eastern China

  • Hong, Changshou;Zhao, Guoyan;Li, Xiangyang
    • Nuclear Engineering and Technology
    • /
    • 제50권3호
    • /
    • pp.453-461
    • /
    • 2018
  • Shaft stations of underground uranium mines in China are not only utilized as waiting space for loaded mine-cars queuing to be hoisted but also as the principal channel for fresh air taken to working places. Therefore, assessment of how mine-car queuing processes affect shaft station radon concentration was carried out. Queuing network of mine-cars has been analyzed in an underground uranium mine, located in Quzhou, Zhejiang province of Eastern China. On the basis of mathematical analysis of the queue network, a MATLAB-based quasi-random number generating program utilizing Monte-Carlo methods was worked out. Extensive simulations were then implemented via MATALB operating on a DELL PC. Thereafter, theoretical calculations and field measurements of shaft station radon concentrations for several working conditions were performed. The queuing performance measures of interest, like average queuing length and waiting time, were found to be significantly affected by the utilization rate (positively correlated). However, even with respect to the "worst case", the shaft station radon concentration was always lower than $200Bq/m^3$. The model predictions were compared with the measuring results, and a satisfactory agreement was noted. Under current working conditions, queuing-induced variations of shaft station radon concentration of the study mine are not remarkable.

Effects of the earth fissure on the seismic response characteristics of a nearby metro station

  • Jiang Chang;Yahong Deng;Huandong Mu
    • Earthquakes and Structures
    • /
    • 제24권1호
    • /
    • pp.53-64
    • /
    • 2023
  • Earth fissures with several kilometers will inevitably approach or cross the metro line, significantly threatening the safety of the underground structure in the earth fissure site. However, the influence of the earth fissure site's amplification effect on the metro station's dynamic response is still unclear. A representative earth fissure in Xi'an was taken as an example to establish a numerical model of a metro station in the earth fissure site. The dynamic response characteristics of the metro stations at different distances from the earth fissure under various seismic waves were calculated. The results show that the existence of the earth fissure significantly amplifies the dynamic response of the nearby underground structures. The responses of the axial force, shear force, bending moment, normal stress, horizontal displacement, inter-story drift, and relative slip of the metro station were all amplified within a specific influence range. The amplification effect increases with the seismic wave intensity. The amplification effect caused by the earth fissure has relatively weak impacts on the axial shear, shear force, bending movement, normal stress, and horizontal movement; slightly larger impacts on the inter-story drift and acceleration; and a significant impact on the relative slip. The influence ranges of the axial force and normal stress are approximately 20 m. The influence ranges of the acceleration and inter-story drift can reach 30 m. Therefore, the seismic fortification level of the underground structure in the earth fissure site needs to be improved.

다중이용시설에서의 실내공기중 미생물 분포에 관한 연구 (Distribution and Classification of Indoor Concentration of Microorganisms in Public Buildings)

  • 김윤신;이은규;엽무종;김기영
    • 한국환경보건학회지
    • /
    • 제28권1호
    • /
    • pp.85-92
    • /
    • 2002
  • A measurement of indoor microorganism using Reuter Centrifugal Air Sampler(RCS) was undertaken during October 1991 - February 1999 and 6-Stage Cascade Air Sampler was undertaken during May 2001 - June 2001 in Seoul. Sites including book store, department store, theater, subway station, underground shopping center, hospital, office building, sports facility, and eduationa institutio were chosen to measure indoor microorganism. The results were as follows: 1. The average of total microorganism collected on the agar strip GK-A media were, in the order, subway station, hospital, underground shopping center, department store, book store, theater, sports facility, educational institution, office building in sites. The highest concentration of 711cfu/m$^3$ was found in the subway station and the lowest concentration of 44cfu/m$^3$ was found in office building. 2. The average of staphylococci collected on the agar strip GK-S media, in the order, were subway station, underground shopping center, hospital and department store, department store, theater, office building, sports facility and educational institution in sites. The highest concentration of 502cfu/m$^3$ was found in the subway station and the lowest concentration of 14cfu/m$^3$ was found in sports facility and educational institution. 3. The average of fungus collected on the agar strip GK-HS media, in the order, were underground hospital, shopping center, theater, subway station, department store, book store, sports facility, educational institution, and office building in sites. The highest concentration of 252cfu/m$^3$ was found in the hospital and the lowest concentration of 32cfu/m$^3$ was found in office building. 4. Ratio of Indoor/Outdoor, determined by site was 1.12-2.38 in total count, 1.00-2.35 in staphylococci, and 0.99-1.34 in fungus. 5. The positive results of test were 12-24% in indoor and 9-43% in outdoor. 6. By gram staining gram positive cocci were 59.9%, gram positive bacill 24.4%, gram negative bacilli 10.4%, and gram negative cocci 0.5%.

5678 서울도시철도 지하역사의 라돈 관리 현황 (Current Status of Radon Management in the 5678 Seoul Metropolitan Rapid Transit Subway)

  • 김준현;윤현식;서강진;우희영;김만화;박종헌
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2011년도 춘계학술대회 논문집
    • /
    • pp.1306-1312
    • /
    • 2011
  • Underground Subway station's air pollutants are introduced from the indoor or outdoor. And Radon is a major pollutant in the subway station. Radioactive substances Radon is occuring naturally in granite tunnel wall and underground water. Especially inert gas Radon that causes lung cancer in human is anywhere but 5678 S.M.R.T. tunnels deep and pass through the granite plaque have a lot of Radon. The Radon concentration is determined by the following reasons : radon content of soil and concrete, underground water, ventilation, pressure difference, building structure, temperature, etc. So Radon concentration is hard to predict. And we can't only ventilate owing to era of high oil prices. This study focuses on our efforts for the reduction of Radon concentration. And the purpose is to provide basically datas of specially managed 15 subway station's Radon concentration.

  • PDF

대심도 지하역사에서 화원 위치에 따른 연기거동 특징 연구 (THE STUDY ON THE CHARACTERISTICS OF FIRE DRIVEN SMOKE-FLOW FOR DIFFERENT FIRE-LOCATION IN DEEPLY UNDERGROUND SUBWAY STATION)

  • 김학범;장용준;이창현;정우성
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2009년 춘계학술대회논문집
    • /
    • pp.202-207
    • /
    • 2009
  • 본 연구에서는 대심도 지하역사에서 화원 위치에 따른 연기거동의 특징을 분석하였다. 전산수치해석에 FDS code가 사용되었다. 화재에 의한 유체거동을 모사하기 위하여 난류모델은 LES를 사용하였으며, 빠른 계산을 수행하기 위하여 병렬수치해석기법을 사용하였다. 본 연구를 통하여 대심도 역사에서 화재시 피난을 저해하는 화원의 위치에 대하여 검토하였다.

  • PDF

다중이용시설에서의 실내공기 중 미생물 분포에 관한 연구 (Distribution and Classification of Indoor Concentration of Microorganisms in Public Buildings)

  • 김윤신;이은규;엽무종;김기영
    • 한국환경보건학회:학술대회논문집
    • /
    • 한국환경보건학회 2002년도 춘계 국제 학술대회
    • /
    • pp.3-5
    • /
    • 2002
  • A measurement of indoor microorganism using Reuter Centrifugal Air Sampler(RCS) was undertaken during October 1991-February 1999 and 6-Stage Cascade Air Sampler was undertaken during May 2001-June 2001 in Seoul. The results were as follows : 1. The average of total microorganism collected on the agar strip GK-A media were, in the order, subway station, hospital, underground shopping center, department store, book store, theater, sports facility, educational institution, office building in sites. 2. The average of staphylcocci collected on the agar strip GK-S media, in the order, were subway station, underground shopping center, hospital and department store, department store, theater, office building, sports facility and educational institution in sites. 3. The average of fungus collected on the agar strip GK-HS media, in the order, were Underground hospital, shopping center, theater, subway station, department store, book store, sports facility, educational institution, and office building in sites

  • PDF