• Title/Summary/Keyword: Underground station

Search Result 317, Processing Time 0.02 seconds

A Study on the Using of Geo-Spatial Information System for Operation and Management of the Underground Facilities (지하시설물의 유지관리를 위한 지형공간정보시스템의 활용에 관한 연구)

  • 신봉호;박영인;엄재구;양승영
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.12 no.1
    • /
    • pp.53-59
    • /
    • 1994
  • The purpose of this paper is to use geo-spatial information system for effective operation and management of the underground facilities. The subject area is selected and collected all of the drawing in order to get the coordinate points(tic), which become the standard of the subject area and that can be gotten by way of practising control surveying from a existing triangulation station spatial information and attribute information are classificated from obtained data. Also, after giving the code in the attribute information to make it data-based, connecting spatial information with the attribute information to overlap layer each other, and compared the positional accuracy of the data. From the results of this study, conclusions are acquired as follows; 1) To construct the Database of the spatial and attribute data, which contain all kinds of drawings in underground structures, the reservation of registers and the details of changes and so on, results in easily referencing, compiling and analyzing the reserved data in system as their own purposes. 2) It is expected that we can effectively operate and manage the situation among the underground facilities so accurately that we may obviate the safety accidents or the damages of life and property.

  • PDF

Growth and Development of Commelina benghalensis L. from Four Seed Types (Commelina benghalensis L.의 생장 연구)

  • Kim, Sang-Yeol
    • Korean Journal of Weed Science
    • /
    • v.18 no.1
    • /
    • pp.42-47
    • /
    • 1998
  • The experiment was conducted to study the growth, developmental pattern, and seed production of Commelina benghalensis L. grown from four seed types; large and small aerial seeds, and large and small underground seeds. Plants from the four seed types differed in growth rate. Based on dry weight and leaf area, plants from large underground seeds emerged and grew faster in the first 2-4 weeks after seeding(WAS) but plants from small aerial seeds grew faster during the 4-6 WAS; thereafter, there was no significant difference in growth rate among plants from the four seed types. Based on seed production, plants from large aerial seed produced more seeds(1473) than those from small seeds(1006). Small aerial types represented 75-77% of the total seed production, large aerial seed 21-23%; only 2-4% were underground seeds. The results suggest that the plants from large underground seeds might have better competitive ability Than those of small aerial seeds during the early growth stage due to faster germination and higher dry matter production.

  • PDF

Betweenness Centrality-based Evacuation Vulnerability Analysis for Subway Stations: Case Study on Gwanggyo Central Station (매개 중심성 기반 지하철 역사 재난 대피 취약성 분석: 광교중앙역 사례연구)

  • Jeong, Ji Won;Ahn, Seungjun;Yoo, Min-Taek
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.44 no.3
    • /
    • pp.407-416
    • /
    • 2024
  • Over the past 20 years, there has been a rapid increase in the number and size of subway stations and underground structures worldwide, and the importance of safety for subway users has also continuously grown. Subway stations, due to their structural characteristics, have limited visibility and escape routes in disaster situations, posing a high risk of human casualties and economic losses. Therefore, an analysis of disaster vulnerabilities is essential not only for existing subway systems but also for deep underground facilities like GTX. This paper presents a case study applying a betweenness centrality-based disaster vulnerability analysis framework to the case of Gwanggyo Central Station. The analysis of Gwanggyo Central Station's base model and various disaster scenarios revealed that the betweenness centrality distribution is symmetrical, following the symmetrical spatial structure of the station, with high centrality concentrated in the central areas of basement levels one and two. These areas exhibited values more than 220% above the average, indicating a high likelihood of bottleneck phenomena during evacuation in disaster situations. To mitigate this vulnerability, scenarios were proposed to distribute evacuation flows concentrated in the central areas, enhancing the usability of peripheral areas as evacuation routes by connecting staircases continuously. This modification, when considered, showed a decrease in centrality concentration, confirming that the proposed addition of evacuation paths could effectively contribute to dispersing the flow of evacuation in Gwanggyo Central Station. This case study demonstrates the effectiveness of the proposed framework for assessing evacuation vulnerability in enhancing subway station user safety and can be effectively applied in disaster response and management plans for major underground facilities.

Identification of PM10 Chemical Characteristics and Sources and Estimation of their Contributions in a Seoul Metropolitan Subway Station (서울시 지하역사에서 PM10의 화학적 특성과 오염원의 확인 및 기여도 추정)

  • Park, Seul-Ba-Sen-Na;Lee, Tae-Jung;Ko, Hyun-Ki;Bae, Sung-Joon;Kim, Shin-Do;Park, Duckshin;Sohn, Jong-Ryeul;Kim, Dong-Sool
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.29 no.1
    • /
    • pp.74-85
    • /
    • 2013
  • Since the underground transportation system is a closed environment, indoor air quality problems may seriously affect many passengers' health. The purpose of this study was to understand $PM_{10}$ characteristics in the underground air environment and further to quantitatively estimate $PM_{10}$ source contributions in a Seoul Metropolitan subway station. The $PM_{10}$ was intensively collected on various filters with $PM_{10}$ aerosol samplers to obtain sufficient samples for its chemical analysis. Sampling was carried out in the M station on the Line-4 from April 21 to 28, July 13 to 21, and October 11 to 19 in the year of 2010 and January 11 to 17 in the year of 2011. The aerosol filter samples were then analyzed for metals, water soluble ions, and carbon components. The 29 chemical species (OC1, OC2, OC3, OC4, CC, PC, EC, Ag, Al, Ba, Cd, Cr, Cu, Fe, Mn, Ni, Pb, Si, Ti, V, Zn, $Cl^-$, $NO_3{^-}$, $SO_4{^{2-}}$, $Na^+$, $NH_4{^+}$, $K^+$, $Mg^{2+}$, $Ca^{2+}$) were analyzed by using ICP-AES, IC, and TOR after proper pretreatments of each sample filter. Based on the chemical information, positive matrix factorization (PMF) model was applied to identify the $PM_{10}$ sources and then six sources such as biomass burning, outdoor, vehicle, soil and road dust, secondary aerosol, ferrous, and brakewear related source were classified. The contributions rate of their sources in tunnel are 4.0%, 5.8%, 1.6%, 17.9%, 13.8% and 56.9% in order.

Evaluation test of applicability of Compressed Air Foam fire extinguishing system for train fire at rescue station in Subsea tunnel (해저터널 구난역 열차화재시 압축공기포(Compressed Air Foam) 소화설비의 적용성 평가 실험)

  • Park, Byoung-Jik;Shin, Hyun-Jun;Yoo, Yong-Ho;Park, Jin-Ouk;Kim, Hwi-Seong
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.18 no.5
    • /
    • pp.413-418
    • /
    • 2016
  • Recently, a mega project such as Korea-China or Korea-Japan undersea tunnel project has been emerged for detail discussion and the interest in undersea tunnel is on the rise. More severe damage by train fire is expected in undersea tunnel comparing to ground tunnel and thus the study on more efficient fire extinguishing system, besides existing disaster prevention design is underway. To that end, a full-scale fire tests using CAF fire extinguishing system which has been developed by modifying traditional foam fire extinguishing system for fire suppression at rescue station in timely manner were conducted over 7 times. The test was conducted after setting the rescue station in virtual tunnel with a car of KTX. As a result of using compressed air foam directly to the fire source, 30 liter of Heptane combustibles was extinguished within 1 minutes. Applicability of compressed air foam to train fire at rescue station in undersea tunnel was has been proven and further study is considered required while changing the nozzle angle and location so as to achieve quick and easy extinguishing goal, making use of the advantage of CAF, as well as to reduce the fire water and chemicals required.

Estimation of Diffusion Direction and Velocity of PM10 in a Subway Station (For Gaehwasan Station of Subway Line 5 in Seoul) (지하철 역사 미세먼지(PM10)의 확산방향과 확산속도 추정 (서울 지하철 5호선 개화산역을 대상으로))

  • Park, Jong-Heon;Park, Jae-Cheol;Eum, Seong-Jik
    • Journal of Korean Society of Transportation
    • /
    • v.28 no.5
    • /
    • pp.55-64
    • /
    • 2010
  • In order to prepare an efficient solution for PM10 reduction in underground stations, the authors measured PM10 concentration levels every 30 minutes in the concourse, platform, and tunnel of Gaehwasan Station of Seoul's subway line 5. Through a correlation analysis of each changing pattern of PM10 concentration, the direction and velocity of diffusion in underground stations were estimated. The PM10 concentration levels were highest in the tunnel, followed by the platform and concourse. PM10 concentrations in the tunnel, platform, and concourse showed a pattern of increasing in the rush hours and decreasing in the non-rush hours. According to the statistical analysis of PM10 concentrations and changing patterns in each location, the higher PM10 concentration in the tunnel expanded to the platform, and some from the platform expanded to the concourse. Therefore, to efficiently reduce PM10 concentrations, it is essential to detect the centralized generation, diffusion factor, expanding route, expanding measure, and other variables and to remove or reduce the diffusion factor and level. Through operating the ventilation system in the right time frame while the PM10 concentration level increases, the power consumption and peak power consumption can be reduced.

A Comparative Study on Construction Method for a Large Underground Station under Pile Supported Bridge (모형실험을 이용한 교량하부 통과 구간 굴착공법 비교 연구)

  • Yoo, Chung-Sik;Chung, Eun-Mok
    • Journal of the Korean Geosynthetics Society
    • /
    • v.16 no.4
    • /
    • pp.177-190
    • /
    • 2017
  • This paper presents the results of an experimental study on the effect of large underground station construction method under an existing pile supported bridge using reduced-scale model tests. A series of tests were conducted on design alternatives using 1g models for different design options for which tunnel structures were created considering the similitude law. Deformation fields obtained using the PIV analysis and LVDTs together with strains in tunnel structures were used to investigate the effect of the construction methods on the pile supported bridge. The results of the tests demonstrated that the pipe roof structure is more efficient in limiting the ground deformation as well as the settlement of bridge foundation than a 2-Arch tunnel. It is also shown that the PIV analysis can be effectively used in analyzing ground tunneling induced ground movement for cases in which a construction sequence governs ground movement.

A Study on the Character and Walking Velocity of Crowd Going up Stairs (계단에서 올라가는 군집보행의 속도에 관한 조사 및 특성에 관한 연구)

  • Park, Jae-Sung
    • Fire Science and Engineering
    • /
    • v.25 no.1
    • /
    • pp.72-77
    • /
    • 2011
  • The effort of transferring some parts of urban functions to the underground space is growing trend among modem cities because of the limit of horizontal land use, the rise of land value, the diversification of human desire, etc. Thus, the basement of building and the subway station have deepened. It calls our attention to safety about evacuation from the underground space to the ground. Until now, the study about crowding walk in stairs has been progressed, focusing on the crowding walk that is going down the stairs, and there is no study about crowding walk that is going up the stairs. This study measured walking pace by crowd density that is going up the stairs in the subway station stairs making one-way movement of crowd. The actual survey showed that the mathematical relation 'V=0.638-0.0949p' determines going up walking velocity at a gradient of $23^{\circ}$, and the mathematical relation will be 'V=0.597-0.1067p' at a gradient of $30^{\circ}$, when it is converted, based on the average walking velocity of crowd by the slope of the stairs which is recommended by Architectural Institute of Japan.

Case Studies on Applications of Convergence Measurement Systems at the Stages of Tunnel Construction and Maintenance (터널 시공 및 유지관리 단계 내공변위 계측시스템 적용사례 연구)

  • Lee, Dae-Hyuck;Han, Il-Yeong;Kim, Ki-Sun;Jin, Suk-Woo
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.2 no.3
    • /
    • pp.59-69
    • /
    • 2000
  • Three-dimensional total station system which integrated the instrument with Target Pin and TEMS 3D software developed by SKEC R&D center was applied to a tunnel excavation for monitoring of convergence and crown settlement. The efficiency of the system was proved as the result in the aspects of exact monitoring and prediction of rock conditions ahead of the face. To monitor the behavior of tunnel lining at the maintenance stage, DOCS system was applied to the subway tunnel section. Such many effects as the vibration of sensors, verification of the system efficiency, the effect of test trains operation, the variation of temperature and the effect of high voltage was checked. Thus the management scheme for tunnel maintenance was laid out as a proposal.

  • PDF

Investigation of ground behaviour between plane-strain grouped pile and 2-arch tunnel station excavation (2-arch 터널 정거장 굴착 시 평면변형률 조건에서 군말뚝의 이격거리에 따른 지반거동 분석)

  • Kong, Suk-Min;Oh, Dong-Wook;Ahn, Ho-Yeon;Lee, Hyun-Gu;Lee, Yong-Joo
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.18 no.6
    • /
    • pp.535-544
    • /
    • 2016
  • Special tunnel design and construction methods have been suggested due to developments of subway and tunnel. Collapse accidents of tunnel bring enormous damage. So, observation and analysis for the safety of tunnelling and behaviour of surrounding ground are important. But, it is not economical to implement the field test in every time. Therefore, this study has measured ground behaviour due to excavation of 2-arch tunnel station according to offset between grouped pile and tunnel by laboratory model test. For the model test, trapdoor device was adopted. Tunnelling is simulated by volume loss of 2-arch tunnel. Ground displacements are observed by close range photogrammetric method and image processing. In addition, these data are compared with numerical analysis.