• 제목/요약/키워드: Underground power cable systems

검색결과 82건 처리시간 0.034초

지중배전선로 서지해석의 실증적 연구 (A Study on the Field Test for Surge Analysis in Underground Distribution Systems)

  • 윤창섭;이종범;이재봉
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.701-702
    • /
    • 2007
  • This paper describes the modelling techniques for surge analysis in underground distribution systems with power cables. To evaluate the Analysis model, the change of line model and permittivity is considered. power cable parameters calculated by LCC of EMTP are considered to evaluate surge model in underground distribution systems. It is evaluated that impulse model according to the shape of impulse source model. However it is confirmed through comparison with measurement value in field test of underground distribution systems.

  • PDF

국내 지중 케이블 고장현황 분석 (Failure Analysis of Underground Transmission Cable Systems)

  • 강연욱;조성배;곽방명;임헌의;윤형희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 E
    • /
    • pp.2377-2379
    • /
    • 1999
  • In order to analyze failure rates of underground transmission power cable systems in Korea, the survey has been performed for the failure cases of cables, joints, and terminations in CV, OF and POF cable systems which occurred from 1983 to 1998. During 16 years, the failure cases due to trips of the systems were 47 among the total 108 cases, These 47 cases could be divided into internal reasons(manufacture/installation, corrosion and degradation) of 16 cases and external reasons (external mechanical damages, lightning, fire. etc.) of 31 cases. For the 154 kV cable systems during 12 years from 1987 to 1998, total failure rate was 0.0057 [case/100C-km/year] and internal reason failure rate was 0.0020 [case/100C-km/Year], which is similar to those of foreign countries. Also, the many cases of internal reason failures occurred in the early stage after the operations due to incorrect installations. This implies that the installation process is very important and some diagnostic tests such as PD measurement are needed besides after laying test.

  • PDF

지중송전계통에서 XLPE케이블의 교량첨가시 모델수립 및 뇌과전압 해석 (Lightning Overvoltage Analysis and Model Establishment of XLPE Cable Underneath a Bridge on Underground Power Cable Systems)

  • 김철호;이종범
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.2243-2244
    • /
    • 2008
  • In this paper, XLPE cable underneath a bridge is modelled using EMTP/ATPDraw. Bridge section is also modelled by mutually coupled parallel conductor with XLPE cable. This paper is analysed the overvoltge by structure change of bridge section when the lightning occurs on the system.

  • PDF

지중송전계통 절연통보호장치 모델링 기법에 관한 연구 (A Study on Modeling Methods for Cable Covering Protective Unit on Underground Power Cable Systems)

  • 최경규;장태인;윤형희;정채균
    • 전기학회논문지
    • /
    • 제56권12호
    • /
    • pp.2098-2102
    • /
    • 2007
  • The conventional CCPU(Cable Covering Protective Unit) modeling methods which are used by Type 99 and Type 92 in EMTP simulation are firstly discussed in this paper, and then some problems of them are also investigated. Modeling method using Type 99 causes unstable characteristic at initial transient of CCPU operation. Time delay has also effect on the output of CCPU modeling. So, in this paper, a new modeling method for CCPU is designed by DBM(Data Base Module) of EMTP. The characteristic of Type 92 is used for the new modeling method. The reliability of this one is proved by comparing simulation with measured data. Specially, at initial transient, the waveform of the new method shows more stable result than that of conventional method using Type 99. Also, the peak value is similar to measured data.

전력케이블 열화진단기법의 현장적용 (Field Application of Power Cable Diagnosis System)

  • 김주용;한재홍;송일근;김상준;이재봉;오재형
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 춘계학술대회 논문집 유기절연재료 전자세라믹 방전플라즈마 일렉트렛트 및 응용기술
    • /
    • pp.148-151
    • /
    • 2002
  • In order to prevent the failures of underground distribution power cables we need to measure insulation condition in the field. Until now we used DC high voltage as a power source for the cable diagnosis but it was not proper method to the XLPE insulation cables because DC high voltage can affect sound insulation and can't diagnose exactly insulation degradation. For these reasons we imported isothermal relaxation current measurement system called by KDA-1 from germany but it's reliability did not proved in our URD cables. DC voltage decay measurement system was developed by domestic company but they don't have field experience. In this paper we tried to prove reliability of these two systems in the field. Through the field diagnosis and Ac breakdown test the two systems showed similar results.

  • PDF

시스순환전류 저감장치 설치시 거리계전기 응동 특성 평가 (Evaluation of Distance Relay Operation Characteristic with the Reduction Devices Installed in Underground Power Cable Systems)

  • 정채균;이종범;강지원
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 A
    • /
    • pp.494-496
    • /
    • 2003
  • This paper analyses the operation characteristic of distance relay when the single line to ground occurs in underground power cable systems that reduction device of sheath circulating current is installed. To apply that reduction device to actual system, the change of line impedance calculated at relay point is also analysed by the connection type of SVLs and fault location, fault inception angle with the installation of reduction device of reactor or not.

  • PDF

인공지락 실증시험을 통한 접속함 종류별 아크에너지 해석 (Analysis of arc-energy with joint box type through a field test)

  • 강지원;장태인;홍동석;이동일;김행덕;오창효;임헌의
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 A
    • /
    • pp.715-717
    • /
    • 2005
  • This paper analyses the arc-energy with joint box type through a field test on underground power OF cable. In order to obtain the data, the actual proof test using short-circuit generation for real scale power transmission tunnel carried out. This paper is expected to contribute the fire accident prevention on underground power cable systems and the believability improvement of electric power facilities.

  • PDF

지중송전케이블 종단접속함 종류에 따른 외기 및 운전온도에 의한 열특성 분석 (Thermal Characteristics Analysis by Ambient and Operating Temperature according to the Kinds of Terminations in Underground Power Cable Systems)

  • 정채균;강지원;이방욱
    • 전기학회논문지
    • /
    • 제64권8호
    • /
    • pp.1154-1160
    • /
    • 2015
  • This paper describes the thermal characteristics of underground power cable system terminations according to the change of ambient temperature as well as operating temperature. Recently, the failure has been gradually increasing in outdoor termination during winter season because the power demand was increased by electricity heating system. The power demand and outdoor temperature is difference between day time and night time. The temperature difference has an influence on conductor extension and shrinkage due to conductor force as well as thermal mechanical characteristics. These phenomena have daily repeated during heating and cooling period of conductors. In these cases, the insulation of outdoor terminations might be degraded by the reduced interface pressure surrounding stress relief cone. Therefore, in this paper, the thermal characteristics are variously analysed by simulation considering power demand and ambient temperature condition during winter season at epoxy type termination as well as slip-on type termination

전력 케이블 실시간 허용전류산정 시스템에 관한 연구 (I) - 실시간 도체 온도 추정 시스템 (A Dynamic Rating System for Power Cables (I) - Real Time CTM(Conductor Temperature Monitoring))

  • 남석현;이수길;홍진영;김정년;정성환
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제52권7호
    • /
    • pp.414-420
    • /
    • 2003
  • The domestic needs for larger capability of power sources are increasing to cope with the expanding power load which results from the industrial developments & the progressed life style. In summer, the peak load is mainly due to the non-industrial reasons such as air-conditioners and other cooling equipments. To cover the concentrated peak load in stable, the power transmission lines should be more constructed and efficiently operated. The ampacity design of the underground cable system is generally following international standards such as IEC287, IEC60853 and JCS168 which regards the shape of 100% daily full power loads. It is not so efficient to neglect the real shapes of load curves generally below 60~70% of full load. The dynamic (real time) rating system tends to be used with the measured thermal parameters which make it possible to calculate the maximum ampacity within required periods. In this paper, the CTM(Conductor Temperature Monitoring) which is the base of dynamic rating systems for tunnel environment is proposed by a design of lumped thermal network ($\pi$-type thermal model) and distribution temperature sensor attached configuration, including the estimation results of its performances by load cycle test on 345kV single phase XLPE cable.

A Study on Lightning Overvoltage Characteristics of Grounding Systems in Underground Distribution Power Cables

  • Jung, Chae-Kyun;Jung, Yeon-Ha;Kang, Ji-Won
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권2호
    • /
    • pp.628-634
    • /
    • 2014
  • This paper investigates the transient characteristics of grounding systems used in under-ground distribution power cables. Recently, two kinds of grounding system are used for underground distribution cables in Korea. The first one is conventional multi-point grounding system, the other is newly proposed non-bundled common grounding system. The non-bundled common grounding system has an advantage the decreasing the power loss due to decrease of the shield circulation current. In this paper, the lightning overvoltage induced in neutral wire (in case of non-bundled common grounding system, overvoltage between opened neural wires and grounding in each phase) of these two kinds of grounding systems are estimated and compared by field tests and EMTP simulations. The EMTP simulation methods are firstly verified by comparison of measurement and simulation. Finally, the insulation level against lightning is expected by EMTP simulation results using verified model.