• Title/Summary/Keyword: Underground pipes

Search Result 213, Processing Time 0.028 seconds

A Study on Characteristic of Underground Corrugated Steel Structure (파형강 지중구조물의 제특성 연구)

  • Park, Yeon Soo;Seo, Byoung Chal;Kim, Byong Ha;Park, Sun Joon
    • Journal of Korean Society of Steel Construction
    • /
    • v.13 no.6
    • /
    • pp.693-702
    • /
    • 2001
  • Ductility pipes, like corrugated steel structures, are expected to reduce its deformation when they are arranged in a row. Verifying this assumption can help make economic designs possible. Though checking the deformation of ductility pipe structures, like corrugated steel structure, decreasing deformation was found when the pipes are arranged in a row. In this way, arranging a corrugated steel structures in a row shows decreased deformation compared to corrugated steel pipes arranged in a single structure because the bedding effect restrains deformation. The deformation rates of reduction are proportionate to the diameter of the corrugated steel structure.

  • PDF

Effect and Issues on the Water Supply Network Management System in Kwangju (광주시 상수도관망관리시스템의 효과 및 문제점에 관한 연구)

  • 오창수
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.16 no.1
    • /
    • pp.103-110
    • /
    • 1998
  • This study deals with the effective management system on the underground facilities by Geographic In-formation System (GIS). For this purpose,"Management System on the Water Supply Network by GIS in Kwangju" was analylized. Following results were obtained in this study. This system could be practically used for the inquiry of water supply and distribution pipes, check valves, pipe equipments and parcel identification numbers. Inquiry of addresses using the parcel identification numbers were effective for the database management system of the water supply facilities. The poits at issue for the performance of this study were the security and education of experts, the security of revenue source, the discord between GIS companies concerned. Establishments of GIS software technologies and database systems, and the settlement between GIS companies were required for the solution of these poits. Development of computer management systems on the water sup-ply network by GIS enabled the replacement of outworn pipes and the leakage inquiry techniques in pipes. in pipes.

  • PDF

Pipe Stiffness Prediction of GRP Flexible Pipe (GRP 연성관의 관강성 예측)

  • Lee, Young-Geun;Kim, Sun-Hee;Park, Joon-Seok;Yoon, Soon-Jong
    • Journal of the Korean Society for Advanced Composite Structures
    • /
    • v.2 no.3
    • /
    • pp.18-24
    • /
    • 2011
  • In this paper, we present the load-deflection behavior of GRP pipes. GRP buried pipes are widely used in construction in the advantage of their superior mechanical and physical characteristics such as high chemical resistance, high corrosion resistance, right weight, smooth surface of the pipe, and cost effectiveness from soil-structure interaction. To design flexible pipes to be buried underground, it should be based on the ASTM D2412(2010). When applying ASTM D 2412(2010) to the design, pipe stiffness(PS) must be predetermined by the parallel-plate test which requires tedious and laborious working process. To overcome such problems, the finite element simulations for finding the load-deflection behavior of the GRP flexible pipes is installed at UTM testing machine. In the finite element simulations, basic data, such as the modulus of elasticity of the material and cross-sectional dimension, is used. From the investigation, we found that the difference between experimental result and analytical prediction is less than 15% when the pipe deflected 3% and 5% of its vertical diameter although the pipe material is not uniform across the cross-section.

Improvement of Physical Condition Assessment in Water Mains (상수도 관로의 물리적 상태평가 기준 개선)

  • Kim, Ju-Hwan;Lee, Doo-Jin;Bae, Cheol-Ho;Ahn, Hyo-Won;Hwang, Jin-Soo;Choi, Doo-Yong
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2010.05a
    • /
    • pp.1710-1715
    • /
    • 2010
  • Service life of water pipes buried in the underground is considerably affected from various factors such as environmental characteristics, pipe characteristics, operation and maintenance, etc. Therefore it is difficult to determine their service life as uniformly the same value assigned by related laws and ordinances. As a result, the service life should be determined by the technical judgement based on the assessment for the condition of water pipes. In this study, It was established that the methodology could predict present and future failure risk, and plan short and long-term strategies for replacement/rehabilitation through the assessment for the physical deterioration and economical values of buried water pipe. The methodology was applied for the verification and reliability to several sites selected in multi-regional transmission pipelines. The proposed method could helps to support reasonable and economical decision of rehabilitation/replacement in the present and future. To improve conventional assessment method of aged water pipes, affecting factors are simplified based on the statistical analysis results from the measured data in the field and the physical deterioration mechanism for better reliability. Also, the guide-line is developed to carry out the reasonal rehabilitation planning through water pipe condition assessment.

  • PDF

Quantitative Evaluation of Remote Field Eddy Current Defect Signals (배관 결함부 원거리장 와전류 신호 정량화 연구)

  • Jeong, Jin-Oh;Yi, Jae-Kyung;Kim, Hyoung-Jean
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.20 no.6
    • /
    • pp.555-561
    • /
    • 2000
  • The remote field eddy current (RFEC) inspection was performed on the ductile cast iron pipes with nominal outer diameter of 100mm, which were machined with various shapes and sizes of defects. Ductile cast iron pipes which are used as water supply pipe have the non-uniform thickness and asymmetric cross section due to relatively high degree of allowable errors during the manufacturing processes. These characteristics of ductile cast in pipes cause the long range background noises in RFEC signals along the pipe. In this study, tile machined defects in pipes were effectively classified by the moving window average (MWA) method which eliminated the long-range noise. The voltage plane polar plots (VPPP) method was used to quantitatively evaluate the depth and circumferential degree of defects. The VPPP signatures showed that the angle between defect signature and the normalized in-phase component on the VPPP is linear to the depth of defects. The nondestructive RFEC technique proved to be capable of quantitatively evaluating the machined defects of underground water supply pipe.

  • PDF

Seismic Fragility of Sewage Pipes Considering Site Response in Korean, Seoul Site (국내 서울지역의 부지응답해석을 고려한 하수도관의 지진취약도)

  • Shin, Dea-Sub;Kim, Hu-Seung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.7
    • /
    • pp.33-38
    • /
    • 2017
  • The number of damaged lifeline structures have been increasing with urban acceleration under earthquakes. To predict the damage, damage mitigation technology of lifeline structures should be analyzed using damage prediction technology. Therefore, in this paper, the degree of the fragility of structures under an earthquake was evaluated stochastically through an evaluation of the seismic fragility. The aim was to develop damage prediction technology of sewage pipes among the lifeline facilities. The site response was performed using the data from 158 boreholes in Seoul and 7 real earthquake waves to determine the responses in real urban areas. The seismic fragility was deduced through a total of 29822 time history analysis. In addition, sewer pipes were evaluated and the persisting period was passed by applying the research results of strength reduction which is due to sulphate erosion. As a result, the difference in failure probability between 300 and 800 with the smaller diameter of the representative pipes was approximately double and the size of the pipes has a significant effect on the seismic fragility function. Moreover, the failure probability of a seismic load increases by up to 10 fold as the strength reduction rate increases. The results of this study can be used as a means of predicting the damage and countermeasures of sewer pipes and might be reflected in the seismic design of underground facilities.

Comparison of Window Functions for the Estimation of Leak Location for Underground Plastic Pipes (지하매설 플라스틱 배관의 누수지점 추정을 위한 창함수 비교 연구)

  • Lee, Young-Sup
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.20 no.6
    • /
    • pp.568-576
    • /
    • 2010
  • It is widely known that the leak locating of underground plastic pipelines is much more difficult than that of cast iron pipelines. The precision of the leak locating depends upon the speed of leak signal and the time delay estimation between the two sensors on the pipeline. In this paper, six different windowing filters are considered to improve the time delay estimation especially for the plastic pipelines. The time delay is usually estimated from the peak time of cross-correlation functions. The filtering windows including rectangle, Roth, Wiener, SCOT, PHAT and maximum likelihood are applied to derive the generalized cross-correlation function and compared each other. Experimental results for the actual plastic underground water supply pipeline show that the introduction of the filtering windows improved the precision of time delay estimation. Some window functions provide excellent leak locating capability for the plastic pipe of 98 m long, which is less than 1 % of the pipe lengths. Also a new probabilistic approach that the combinations of all results from each filtering window is suggested for the better leak locating.

A Study on Improving the Data Quality Validation of Underground Facilities(Structure-type) (지하시설물(구조물형) 데이터 품질검증방법 개선방안 연구)

  • Bae, Sang-Keun;Kim, Sang-Min;Yoo, Eun-Jin;Im, Keo-Bae
    • Journal of Cadastre & Land InformatiX
    • /
    • v.51 no.2
    • /
    • pp.5-20
    • /
    • 2021
  • With the available national spatial information that started from the sinkholes that occurred nationwide in 2014 and integrated 15 areas of underground information, the Underground Spatial Integrated Map has been continuously maintained since 2015. However, until recently, as disasters and accidents in underground spaces such as hot water pipes rupture, cable tunnel fires, and ground subsidence continue to occur, there is an increasing demand for quality improvement of underground information. Thus, this paper attempted to prepare a plan to improve the quality of the Underground Spatial Integrated Map data. In particular, among the 15 types of underground information managed through the Underground Spatial Integrated Map, quality validation improvement measures were proposed for underground facility (structure-type) data, which has the highest proportion of new constructions. To improve the current inspection methods that primarily rely on visual inspection, we elaborate on and subdivide the current quality inspection standards. Specifically, we present an approach for software-based automated inspection of databases, including graphics and attribute information, by adding three quality inspection items, namely, quality inspection methods, rules, and flow diagram, solvable error types, to the current four quality inspection items consisting of quality elements, sub-elements, detailed sub-elements, and quality inspection standards.

The deformation behavior of soil tunnels reinforced with RPUM and fiberglass pipes (RPUM과 유리섬유 파이프로 막장을 보강한 토사터널의 변형거동)

  • Nam, Gi-Chun;Heo, Young;Kim, Chi-Whan;You, Kwang-Ho
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.4 no.3
    • /
    • pp.185-193
    • /
    • 2002
  • In this paper, deformation behavior of shallow subway tunnel excavated in weathered soil and reinforcement effects of longitudinal support measures are investigated via three dimensional FDM analysis. Two excavation methods, half-face excavation and full-face excavation, are considered in simulation to study the influences of excavation methods on tunnel deformation behavior. In addition, the reinforcing effects of RPUM and fiberglass pipe are compared. Face extrusion, covergence, preconvergence, and sidewall displacement are investigated to analyze tunnel deformation behavior, and surface settlement is used to analyze the effects of excavation methods and longitudinal supports measures. The simulation results show that half-face excavation induces larger convergence, preconvergence, sidewall displacement, surface settlement than full-face excavation, while full-face excavation induces larger extrusion than half-face excavation. In addition, under same excavation method, all displacements are larger when RPUM is only used for longitudinal support than when RPUM is jointly used with fiberglass pipes.

  • PDF

Comparison of earth pressure around pipe-roof between UPRS and front-jacking method (UPRS 공법과 프론트잭킹 공법의 파이프루프 주변 현장토압 계측결과 비교)

  • Sim, Youngjong;Jin, Kyu-Nam;Song, Ki-Il
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.17 no.5
    • /
    • pp.513-522
    • /
    • 2015
  • This study is to confirm the effect of pre-installed pipe-roof by measuring earth pressure acting on the underpass. In recently developed trenchless methods pre-inserted steel pipes before ground excavation to form pipe-roof are connected each other with re-bars and filled with mortar. In this study, focusing on the Upgraded Pipe Roof Structure method (UPRS) and Front-Jacking, earth pressure around pipe-roof is measured after insertion of steel pipe to ensure the effect of earth pressure reduction. In case of the UPRS earth pressure is considerably reduced because of the reinforced effect of pipe-roof. In case of the Front-Jacking in which the whole underpass structure is pushed into the ground, earth pressure is not reduced as expected, because the pre-installed pipes are not needed to be reinforced.