• Title/Summary/Keyword: Underground parking lot

Search Result 114, Processing Time 0.023 seconds

Improvement of Underground Parking Garages Lighting in Residential Areas (아파트의 지하주차장의 조명 운영개선)

  • Chang, Soo-Jung;Choi, An-Seop;Choi, Sung-Youl
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.163-168
    • /
    • 2004
  • The improvement of perspectives on dark and limited underground space could be an important factor in successful underground space development. Current trend in the apartment underground parking lot requires not only quantitatively energy efficient design and operation, but also qualitative improvement of the space. For this, we need to consider two factors: Firstly, to understand the characteristics of the fluorescent lamp. Secondly, to improve the uniformity ratio of illuminance. In winter season, a way to keep the uniformity and a method not to lower the indoor illuminance level by cold ambient air. Therefore, a change in interval and arrangement of the lighting fixtures is required. Also, in their operation, current time-fixed control method needs to be changed into the control that method considers the use pattern.

  • PDF

Design of Samduck Underground Parking Lot and Park in Anyang (안양 삼덕 지하주차공원 설계)

  • Choi Shin-Hyun
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.33 no.5 s.112
    • /
    • pp.114-122
    • /
    • 2005
  • Anyang city performed a design competition for the existing paper mill site and this design is the work that was submitted to that competition. The design instructions for the competition were about an organic site which had harmony of aboveground park and underground parking lot, establishment of park planning which is fit for the features of nearby areas, and security of proper parking space. This design criteria set the design concept to a new wave of Anyang by reflecting the design instructions of prize contest and features of the site and developed it as three waves. First, the eco wave, one of three waves, means that it compose the ecological healthy park and urban environment together with restoration and preservation of Suamcheon (stream), and futhermore the waves that the natural resource are maintained in a delicate ecological balance as the water resource of Anyang city are connected to the axis of mountain resource. Secondly, the emotion wave indicates that the wave toward culture and art emotional park that stimulates and fills up the emotion to makes impoverishing modems minds fertile. Thirdly, the health wave means the waves toward a park to keep the sound of minds and bodies of Anyang citizens, and healthy and sound life as well as the waves toward a park to contribute the healthy leap and development of Anyang. These three waves will enrich the park keeping the dynamic relationship mutually and will be a new culture and art code of Anyang city.

Study for Curling Control of Plain Concrete in Underground Parking Lot (지하주차장 무근콘크리트 컬링제어를 위한 연구)

  • Seo, Tae-Seok;Choi, Hoon-Jae
    • Journal of the Korea Institute of Building Construction
    • /
    • v.18 no.3
    • /
    • pp.243-249
    • /
    • 2018
  • The study for curling control of plain concrete in underground parking lot was conducted in this study. The shrinkage reducing agent(SRA) was used to minimize the curling deformation of plain concrete in underground parking lot. For the quantitative curling control, the simplified prediction method applying the deflection theory of cantilever beam was proposed too, and the validity of prediction method was examined through the comparison between the experimental values and predictive values. In result, the curling of SRA 1.0% concrete was about 30% less than that of SRA 0.0% concrete, and the possibility of curling estimation by the simplified prediction method was confirmed through the comparison between the experimental values and predictive values.

Ignition of ceiling insulation depending on working condition of Sprinkler head in underground parking lot fire (지하주차장 화재 시 스프링클러헤드 작동 여부에 따른 천장 위 단열재의 발화 여부)

  • Kim, Seo-Young;Kong, Ha-Sung
    • The Journal of the Convergence on Culture Technology
    • /
    • v.8 no.1
    • /
    • pp.461-468
    • /
    • 2022
  • This study is focused on the ignition of ceiling insulation depending on working condition of Sprinkler head in underground parking lot fire. When temperature changes of same point were measured depending on sprinkler's working condition, in Scenario 1, inner temperature at border of spray applied material(SP-2) of ceiling part near the fire and ceiling insulation(blowing polystyrene) was 658.27℃ and its which inner maximum temperature is higher than 427℃ which is the ignition point of ceiling insulation(blowing polistyrene), so it was observed that flame is ignited on the ceiling insulation and spread fire. In scenario 2, Inner fire temperature at border of spray applied material(SP-2) and ceiling insulation(blowing polystyrene) near the fire was 53.10℃ and it was lower than ignition point so it was observed that flame was not ignated on the ceiling insulation. As a result, it was foreseen that possibility of ignition on the ceiling insulation depending on working condition of sprinkler.

Applicability of Composite Polyurea Method Considering the Required Performance in Underground Parking Lot Upper Slab (공동주택 지하주차장 상부슬래브의 요구성능을 고려한 복합형 폴리우레아 공법의 적용성 검토)

  • Lee, Jung-Hun;Choi, Eun-Kyu;Song, Je-Young;Kim, Soo-Yeon;Oh, Sang-Keun
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.7 no.3
    • /
    • pp.243-254
    • /
    • 2019
  • In this study, problems of the waterproofing methods in which water leakage occurs in the upper slab of the underground parking lot of apartment houses and the requirements considering the characteristics of the upper slab, and selected the appropriate performance(proposal) for the composite polyurea process are reviewed. As a result of the study, it is necessary to review performance such as responsiveness to upper slab of the multi-unit underground parking lot that is comprised of (1) crack and behavior responsiveness, (2) surface integrity, (3) vertical watertight stability, (4) pressure layer construction, (5) impact and pressure response and (6) vehicle moving load. As a result of evaluating 5 items corresponding to the requirements for the soft and hard complex polyurea, all of them were found to meet the conditions, and each materials were improved by compounding the materials that had problems when applying a single-ply method, thereby clarifying the advantages and disadvantages of the material property. However, in order to apply to the actual site, additional evaluation on site applicability such as mock-up evaluation should be conducted, and subsequent studies on the applicability of the market through review of economic feasibility and maintenance is required.

Trace Element Analysis and Source Assessment of Parking Lot Dust in Large Shopping Mall (대형유통업소주차장의 축적먼지 중 미량원소성분 분석과 오염원 평가)

  • Song, Hee-Bong;Ahn, Jeong-Eem;Jung, Yeoun-Wook;Yoon, Ho-Suk;Keum, Jong-Lok;Do, Hwa-Seok;Kim, Sun-Suk;Kim, Jong-Woo
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.34 no.3
    • /
    • pp.168-176
    • /
    • 2012
  • A total of 48 dust samples were collected from large shopping mall parking lots in Daegu metropolitan city in March 2011. Samples were sieved through a 100 ${\mu}m$ mesh and the concentration of 14 elements have been determined using by ICP after acid extraction. Results showed that Ca, Fe, K, Mg, Mn, Na and V were affected by natural sources while Cd, Cr, Cu, Ni, Pb and Zn were affected by anthropogenic sources. The measured values were remarkably higher in components from natural sources than in components from anthropogenic sources. Anthropogenic trace element concentrations of ground roof dust were higher than those of ground and underground indoor dust. A large percentage of trace elements came from natural sources rather than anthropogenic sources. The percentage composition of chemicals of ground roof dust were higher than those of ground and underground indoor dust. This study showed that investigated parking lots were rarely contaminated with hazardous heavy metals. The heavy metal pollution of ground roof were higher than those of ground and underground indoors. The correlation analysis among trace elements suggest that components in ground roof were more highly correlated than those in ground and underground indoor. Also anthropogenic trace element levels were well correlated with parking lot age and parking density.

A Study on Wind-Driven Ventilation Performance According to Opening Types in Basement Parking Lots of Apartment - Investigation of Wind Pressure Coefficient by Wind Tunnel Test - (공동주택 지하주차장의 개구유형에 따른 풍력환기 성능에 관한 연구 - 풍동실험에 의한 풍압계수 검토 -)

  • Roh, Ji-Woong
    • KIEAE Journal
    • /
    • v.11 no.6
    • /
    • pp.37-42
    • /
    • 2011
  • This Paper aims for analyzing the effect of opening types on wind-driven ventilation performance in basement parking lots of apartment. The scale model of basement parking lot was made, wind tunnel tests conducted. Wind pressure of three opening types was measured, wind pressure coefficient calculated. As the result, it showed that the air flow pattern of stack type opening was strongly changed by wind direction, but it was almost not at scuttle vent type. But, as for the difference of wind pressure coefficient, stack type opening was more than the other two types.

Design of Parking Guidance System using Visible Light Communication with LED Illumination (LED 조명과 가시광 통신을 이용한 주차안내 시스템 설계)

  • Yun, Young-June;Kong, In-Yeup
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2010.05a
    • /
    • pp.560-562
    • /
    • 2010
  • Nowdays, The LED Illumination system can achieve lower power consumption and has a longer life-time compared to the fluorescent lamp system. Visible Light Communication(VLC) is wireless optical communication to use visible light of LED. This paper designs the indoor navigation of Location-Based Service(LBS) using LED illumination. and the parking guidance system using VLC in the underground parking lot. We show the result of experimentation and confirm possibility of the parking guidance system.

  • PDF

Leakage Situation and Main Leakage Areas of Domestic Residential Building Underground Parking Lots (국내 공동주택 지하주차장의 누수 실태 및 주요 누수 부위 조사)

  • Lee, Jung-Hun;Song, Je-Young;Oh, Sang-Keun
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.4 no.4
    • /
    • pp.496-503
    • /
    • 2016
  • This paper studies the leakage situation of domestic residential building underground parking lots and main leakage areas. 18 complexes were studied and the results showed that 80% of buildings with exterior waterproofing had no leakage, but all buildings with interior waterproofing had leakage. According to a survey among professionals, water leakage problems are considered to be severe in underground parking lots and a preventative measure is required by the government. By comparing the survey and the actual situation at hand, the results showed that the lowest floor slab, wall construction joints, and floor expansion joints were the most prone to leakage. Based on the results, further study to develop a design manual for the appropriate prevention of leakage is deemed necessary.

A Study on the Loss Reduction Method of Reinforcing Bar through Case Study

  • Park, U-Yeol;Jung, Hyeon-Ok;Kang, Tai-Kyung;Cho, Hun-Hee
    • Journal of the Korea Institute of Building Construction
    • /
    • v.10 no.4
    • /
    • pp.123-132
    • /
    • 2010
  • Rebar work accounts for approximately 30% of the total construction costs for rebars and concrete. Recently, the high rising prices of rebars have become one of the principle factors of rising construction costs. Therefore, construction companies are putting much effort into loss reduction of rebars. Consequently, in this study, we wished to present loss reduction methods of rebars before the preparation of the placing drawings. To devise such methods, we collected previous case studies and analyzed methods that were applied for loss reduction. As a result of the analysis, we were able to find the following methods for loss reduction of rebars: method of reducing the number of splices at the mat foundation, method of reducing splice length at the internal columns or walls of the underground parking lot, method of reducing cap-ties of internal beams of basement floors excluding perimeter beams, and method of reducing anchorage length at the internal column or wall of the underground parking lot. Based on those analysis results, we presented our own loss reduction methods of rebars. Applying our methods resulted in considerable loss reduction.