• 제목/요약/키워드: Underground cables

검색결과 244건 처리시간 0.283초

초고압 XLPE 케이블 접속함의 부분방전 펄스파형 시뮬레이션 (Pulse Waveform Simulation of Partial Discharges for HV XLPE Cable Joints)

  • 김정태
    • 전기학회논문지
    • /
    • 제67권1호
    • /
    • pp.75-81
    • /
    • 2018
  • In this study, the simulation of partial discharge pulse waveform have been performed for the typical joints such as EBA and PMJ in the HV underground transmission XLPE cable system in order to improve the understanding of partial discharge pulse waveform and the on-site measurement accuracy of partial discharges. FDTD simulation technique was adopted for the simulation and has been shown to be suitable for partial discharge simulation of power cables in terms of pulse propagation characteristics and waveform formation. The simulation results for the EBA showed that the second not-so-large opposite polarity peak appeared after the first negative polarity peak and the measurement sensitivity was the highest near the bottom of the EBA copper box. In the analysis results for PMJ, the magnitude of the second opposite polarity peak was large enough to compare with the first peak, and the measurement sensitivity at the end of the PMJ copper box was the highest. These simulation results show considerable similarity with the on-site measurement, and it would be very useful for the partial discharge measurement of HV XLPE cable systems.

CAPD기법을 이용한 부분방전 현상 해석에 관한 연구 (Analysis of Partial Discharge Phenomena by means of CAPD)

  • 김성홍
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 하계학술대회 논문집 Vol.3 No.2
    • /
    • pp.939-944
    • /
    • 2002
  • PD phenomena can be regarded as a deterministic dynamical process where PD should be occurred if the local electric field be reached to be sufficiently high. And thus, its mathematical model can be described by either difference equations or differential equations using several state variables obtained from the time sequential measured data of PD signals. These variables can provide rich and complex behavior of detectable time series, for which Chaos theory can be employed. In this respect, a new PD pattern recognition method is proposed and named as 'Chaotic Analysis of Partial Discharges (CAPD)' for this work. For this purpose, six types of specimen are designed and made as the models of the possible defects that may cause sudden failures of the underground power transmission cables under service, and partial discharge signals, generated from those samples, are detected and then analyzed by means of CAPD. Throughout the work, qualitative and quantitative properties related to the PD signals from different defects are analyzed by use of attractor in phase space, information dimensions ($D_0$ and D2), Lyapunov exponents and K-S entropy as well. Based on these results, it could be pointed out that the nature of defect seems to be identified more distinctively when the CAPD is combined with traditional statistical method such as PRPDA. Furthermore, the relationship between PD magnitude and the occurrence timing is investigated with a view to simulating PD phenomena.

  • PDF

전력회사 계통에 22kV급 초전도 케이블 도입을 위한 적용 개소 고찰 (A Study on the Application of 22kV class Superconducting Cable in Utility Network)

  • 김종율;윤재영;이승렬
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제5권2호
    • /
    • pp.20-29
    • /
    • 2003
  • As power systems grow more complex and power demands increase, the need of underground transmission system is increasing gradually. But it is very difficult and high in cost to construct new ducts and/or tunnels for power cables in metropolitan areas. HTS (High Temperature Superconducting) cable can carry very high current densities with strongly reduced conductor loss and allow high power transmission at reduced voltage. Therefore HTS cable can transfer more power to be moved in existing ducts, which means very large economical and environmental benefits. A development project for a 22kV class HTS cable is ongoing at a research centers, and the cable manufacturer in Korea. In this paper, we carried out investigation for application of 22kV class HTS cable in Korean utility networks. The results show that the HTS cable is applicable to replace IPB in pumping-up power plant, withdrawal line in distributed generation, withdrawal line in complex power plant, and conventional under ground cable. Finally, as the cost of HTS wire and refrigeration drops, the technical and economical potential of HTS cable is evaluated positively.

충격파-부분방전(SI-PD) 시험방법을 이용한 케이블 진단에 관한 기초 연구 (A Possible diagnostic method of cable system using SI-PD measurement)

  • 김정태;구자윤;장은;조연옥;김상준;송일근;김주용
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 C
    • /
    • pp.1774-1777
    • /
    • 1996
  • In this paper, applicability of SI-PD(switching impulse - partial discharge) testing method was put on an attempt as a newly proposed diagnostic method for the underground distribution power cable system in Korea. For this purpose, SI-PD testing equipment was designed, and tests were performed using artificial needle-type defects integrated into the 22.9 kV CN/CV cables in drder to prove its reliability. As a result, arc noises, generated from spark gap, were considerably decreased by use of a pneumatic switch immersed into oil, and artificial needle-type defects were well detected with impulse voltage level under $2U_0$. These results imply that it is likely possible to apply SI-PD measurement method as a the nondistructive test for the 22.9 kV CN/CV cable system in Korea.

  • PDF

웨이브렛 변환을 이용한 혼합송전계통에서의 디지털 거리계전 알고리즘에 관한 연구 (A Study on the Digital Distance Relaying Algorithm Using Wavelet Transform in Combined Transmission Line with Underground Power Gables)

  • 정채균;홍동석;이종범
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.383-386
    • /
    • 2001
  • Distance relay is tripped by the line impedance calculated at the relay point. Accordingly the accurate operation depends on the precise calculation of line impedance. Impedance can be accurately calculated in case of overhead line. However, in case of power cables or combined transmission lines, impedance can not be accurately calculated because cable systems have the sheath, grounding wires, and cable cover protection units (CCPUs). There are also several grounding systems in cable systems. Therefore, if there is a fault in cable system, these terms will severely be caused much error to calculation of impedance. Accordingly the proper compensation should be developed for the correct operation of the distance relay. This paper presents the distance calculating algorithm in combined transmission line with power cable using wavelet transform. In order to achieve such purpose, judgement method to discriminate the fault section in both sections was proposed using db1 coefficient summation. And also, error compensation factor was proposed for correct calculation of impedance in power cable.

  • PDF

PCB 피딩 라인에 의한 위상차를 이용한 Quadrifilar Helical Antenna의 제작 (Implementation of Quadrifilar Helical Antenna Using Phase Difference with PCB Feeding Line)

  • 박상조
    • 한국컴퓨터정보학회논문지
    • /
    • 제13권6호
    • /
    • pp.211-216
    • /
    • 2008
  • 휴대전화를 통해서 양질의 DMB(Digital Multimedia Broadcasting) 서비스를 받기 위하여 지하나 건물사이 음영지역을 제거하기 의한 갭필러(Gap filler) 안테나가 필요하다. 동축 급전선과 4개의 임피던스 정합회로를 필요로 하는 종래의 방식에 비하여 PCB의 피딩 라인에 의한 위상 차이를 이용한 Quadrifilar Helical Antenna(QHA)를 설계하고 제작한다. MicroWave Studio를 이용한 시뮬레이션을 통하여 기존 방식의 QHA에 비해 안테나의 크기와 직경이 안테나 특성에 많은 영향을 주는 것을 파악하여 QHA 제작에 활용하였다. 시뮬레이션을 통한 설계 데이터를 근거로 별도의 임피던스 정합회로가 필요 없는 QHA를 제작하여, 전기적 특성을 측정한 결과 설계치와 유사한 특성을 얻었다.

  • PDF

Damage detection for pipeline structures using optic-based active sensing

  • Lee, Hyeonseok;Sohn, Hoon
    • Smart Structures and Systems
    • /
    • 제9권5호
    • /
    • pp.461-472
    • /
    • 2012
  • This study proposes an optics-based active sensing system for continuous monitoring of underground pipelines in nuclear power plants (NPPs). The proposed system generates and measures guided waves using a single laser source and optical cables. First, a tunable laser is used as a common power source for guided wave generation and sensing. This source laser beam is transmitted through an optical fiber, and the fiber is split into two. One of them is used to actuate macro fiber composite (MFC) transducers for guided wave generation, and the other optical fiber is used with fiber Bragg grating (FBG) sensors to measure guided wave responses. The MFC transducers placed along a circumferential direction of a pipe at one end generate longitudinal and flexural modes, and the corresponding responses are measured using FBG sensors instrumented in the same configuration at the other end. The generated guided waves interact with a defect, and this interaction causes changes in response signals. Then, a damage-sensitive feature is extracted from the response signals using the axi-symmetry nature of the measured pitch-catch signals. The feasibility of the proposed system has been examined through a laboratory experiment.

역문제를 이용한 2차원 산란장에서의 소스 추정 (Source Identification in 2-Dimensional Scattering Field Based on Inverse Problem)

  • 김태용;이훈재
    • 한국정보통신학회논문지
    • /
    • 제18권6호
    • /
    • pp.1262-1268
    • /
    • 2014
  • 역문제는 특히 시스템 모델링 및 모니터링과 같은 과학 및 공학분야에서 매우 흥미로운 주제이다. 역문제를 활용하면 광물자원의 탐사, 지하에 매설된 케이블 및 파이트라인 등의 동정, 의료 분야에서의 비파괴 검사 등에 응용가능하다. 본 연구에서는 먼저 2차원 전자계 산란문제를 다루고 이에 대한 FDTD법 정식화를 다룬다. 이 경우 근방계에서 관측된 데이터를 토대로 미지의 소스를 추정하기 위한 방법으로서 비선형 CGM법을 이용하였다. 본 연구에서 제안된 방법에 따른 실험결과로 볼 때 임베디드 시큐리티 모듈과 같은 원 신호 추정문제에 적용 가능할 것으로 보인다.

Application of Particle Swarm Optimization to the Reliability Centered Maintenance Method for Transmission Systems

  • Heo, Jae-Haeng;Lyu, Jae-Kun;Kim, Mun-Kyeom;Park, Jong-Keun
    • Journal of Electrical Engineering and Technology
    • /
    • 제7권6호
    • /
    • pp.814-823
    • /
    • 2012
  • Electric power transmission utilities make an effort to maximize profit by reducing their electricity supply and operation costs while maintaining their reliability. The development of maintenance strategies for aged components is one of the more effective ways to achieve this goal. The reliability centered approach is a key method in providing optimal maintenance strategies. It considers the tradeoffs between the upfront maintenance costs and the potential costs incurred by reliability losses. This paper discusses the application of the Particle Swarm Optimization (PSO) technique used to find the optimal maintenance strategy for a transmission component in order to achieve the minimum total expected cost composed of Generation Cost (GC), Maintenance Cost (MC), Repair Cost (RC) and Outage Cost (OC). Three components of a transmission system are considered: overhead lines, underground cables and insulators are considered. In regards to aged and aging component, a component state model that uses a modified Markov chain is proposed. A simulation has been performed on an IEEE 9-bus system. The results from this simulation are quite encouraging, and then the proposed approach will be useful in practical maintenance scheduling.

지중 전력케이블용 절연재료의 열적 특성 및 기계적 특성 (Thermal and Mechanical Properties of Insulation Materials for Underground Power Cable)

  • 이경용;이관우;최용성;박대희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 춘계학술대회 논문집 방전 플라즈마 유기절연재료 초전도 자성체연구회
    • /
    • pp.138-141
    • /
    • 2004
  • In this paper, we Investigated effects on impurities and water of semiconductive shield through a thermal, mechanical, and absorption experiment to estimate performance of insulating materials in power cable. Specimens had been prepared 22[kV], 154[kV] XLPE power cables and then were made of sheet form with XLPE and semiconductive shield with dimension of 0.4[mm] ~1.2[mm] of thickness from power cable. Heat capacity $({\Delta}H)$ and glass trasition temperature (Tg) of XLPE sheet were measured by DSC (Differential Scanning Calorimetry). We could know that thermal stabilities of 154[kV] are more excellent than 22[kV] from this experimental result. The strain of mechanical properties in 22[kV] and 154[kV] XLPE was 486[%], 507[%] and stress was 1.74$[kgf/mm^2]$, 1.80$[kgf/mm^2]$. The absorption contents of existing semiconductive shield were measured 710[ppm] to 1,090[ppm], and semiconductive shield of 22[kV] cable was measured 14,750[ppm] to 24,780[ppm]. We thermal and mechanical properties of 154[kV] could know more excellent than 22[kV] from this experimental result.

  • PDF