• 제목/요약/키워드: Underground cable tunnel

검색결과 77건 처리시간 0.029초

인공지락 실증시험을 통한 접속함 종류별 아크에너지 해석 (Analysis of arc-energy with joint box type through a field test)

  • 강지원;장태인;홍동석;이동일;김행덕;오창효;임헌의
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 A
    • /
    • pp.715-717
    • /
    • 2005
  • This paper analyses the arc-energy with joint box type through a field test on underground power OF cable. In order to obtain the data, the actual proof test using short-circuit generation for real scale power transmission tunnel carried out. This paper is expected to contribute the fire accident prevention on underground power cable systems and the believability improvement of electric power facilities.

  • PDF

손실율을 이용한 전력구내 온도특성 해석 (A Study on the Temperature Characteristics Analysis in Tunnel using Loss Factor)

  • 이상근
    • 전기학회논문지P
    • /
    • 제63권2호
    • /
    • pp.107-112
    • /
    • 2014
  • To cope with the ever increasing electric power demands in metropolitan areas, a greater underground cable transmission capacity is required. In general, it must be determined whether the temperature in the tunnel maintains the maximum allowable temperature. In order to improve this point, it is used to the loss factor. But, for economic cooling, it is problem to use such loss factor in this country. In this study, based on the load factor in this country, technique for calculating the loss factor has been presents. The suggested method has been tested in a sample section using the computer and the results have shown the usefullness of the suggested method.

전력구의 지진응답해석에 사용되는 응답진도법의 보수성 평가 (Conservativeness Evaluation of Response Acceleration Method used in Seismic Response Analysis of Power Cable Tunnel)

  • 임재성;김기배;전낙현;김재민
    • 한국전산구조공학회논문집
    • /
    • 제34권5호
    • /
    • pp.309-317
    • /
    • 2021
  • 이 논문에서는 박스형 전력구의 지진응답해석에 사용되는 응답진도법의 보수성을 평가하였다. 이를 위해 25가지 전력구 단면과 각 전력구에 대한 2개의 지반조건을 고려한 총 50개 예제를 선정하였다. 응답진도법의 보수성을 평가하기 위해 동적 지반-구조물 상호작용을 고려한 정밀해석법에 의한 응답과 비교하였다. 비교결과, 정밀해석 응답에 대한 응답진도법에 의한 응답의 비로 정의한 응답비의 평균이 1.0에 근접하며, 응답비의 표준편차도 5% 이내로 매우 작아서, 응답진도법에 의한 해석이 정밀해석법과 일관됨을 알 수 있었다. 마지막으로 응답진도법에 의한 응답에 하중계수 1.1을 적용하면 전력구의 보수적인 내진설계가 가능할 것으로 나타났다.

GPR에 의한 안전진단 사례 (Case Studies of Safety Diagnosis by GPR)

  • 한자경;최광철
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 1999년도 지반조사 세미나
    • /
    • pp.169-180
    • /
    • 1999
  • Ground penetrating radar(GPR) uses radio waves to detect buried objects in any non-metallic material. Initially it was used to detect structures in ice. GPR has evolved to include the penetration of soils, rocks and man-made structures. GPR uses a sensitive detector to record weak radio waves reflected from objects embedded in the material under investigation. In this study, the GPR is applied to outside plant telecommunication facilities such as cable tunnels, manholes and underground conduits and model experiments to obtain radar characteristics. The thickness and soundness of tunnel lining can be evaluated, and the location of rebars and steel ribs can also be found effectively. The location of underground conduits as well as manholes can be found and the results of GPR give good coincidence with design drawings. In order to investigate the tunnel lining, the GPR mounted vehicle is developed and it is proved that the vehicle can save time and manpower.

  • PDF

동축 케이블을 이용한 시간영역 반사법의 암반변위 계측에의 적용 (Application of Time Domain Reflectometry to the Monitoring or Rock Mass Deformation with Coaxial Cable)

  • 정슬람;정소걸;정현기;박철환;박철환;이희근
    • 터널과지하공간
    • /
    • 제6권4호
    • /
    • pp.306-315
    • /
    • 1996
  • This paper presents an application of the TDR(Time Domain Reflectometry) to the monitoring of the deformation of rock mass with grouted coaxial cables through laboratory tests. The grouted cable can easily deform together with the rock mass movements, and the deformed cable loses its original capacitance and the reflected waveform produced along the deformed cable consequently represents a change of voltage pulse. Therefore, it is possible to monitor the deformation of rock mass by measuring the changes in these reflection signatures. Shear test of the cemented mortar containing a specimen of coaxial cable showed that the shear deformation correlated linearly with the reflection coefficient, so the TDR was effective to monitor the displacement of the rock mass. Bending test were carried out in order to determine the influence of the crooked cables on the monitoring of rock mass movements. Controlled cirmping and shearing test upon a cable of 50 m long, 12.7 mm diameter showed not only the fact that the reflection amplitudes decreased as the cable length increased but also the proper crimping depth, width and interval between two adjacent crimps. Two coaxial cables-one 100 m long and other 175m long-were installed and grouted into the separate boreholes drilled in a sedimentary formation. The behavior of the cable was monitored with metallic TDR cable tester to measure rock mass deformation based on the interpretative techniques developed through laboratory tests.

  • PDF

전력 케이블 실시간 허용전류산정 시스템에 관한 연구 (I) - 실시간 도체 온도 추정 시스템 (A Dynamic Rating System for Power Cables (I) - Real Time CTM(Conductor Temperature Monitoring))

  • 남석현;이수길;홍진영;김정년;정성환
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제52권7호
    • /
    • pp.414-420
    • /
    • 2003
  • The domestic needs for larger capability of power sources are increasing to cope with the expanding power load which results from the industrial developments & the progressed life style. In summer, the peak load is mainly due to the non-industrial reasons such as air-conditioners and other cooling equipments. To cover the concentrated peak load in stable, the power transmission lines should be more constructed and efficiently operated. The ampacity design of the underground cable system is generally following international standards such as IEC287, IEC60853 and JCS168 which regards the shape of 100% daily full power loads. It is not so efficient to neglect the real shapes of load curves generally below 60~70% of full load. The dynamic (real time) rating system tends to be used with the measured thermal parameters which make it possible to calculate the maximum ampacity within required periods. In this paper, the CTM(Conductor Temperature Monitoring) which is the base of dynamic rating systems for tunnel environment is proposed by a design of lumped thermal network ($\pi$-type thermal model) and distribution temperature sensor attached configuration, including the estimation results of its performances by load cycle test on 345kV single phase XLPE cable.

케이블 삼상단락 실증시험을 통한 전자력 영향 검토 (The Study of Electromagnetic Force by Three Phase Short-Circuit Test of Cable)

  • 홍동석;김해준;박성민;장우석;박흥석;장태인;강지원
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.395_396
    • /
    • 2009
  • This paper handles with effect of electromagnetic force on the cables by fault current accompanied by accident of underground transmission cable. Even though underground transmission cable is an essential transmission method to supply stable power for downtown and population center, interaction of electromagnetic force from fault current is very large comparing to overhead transmission line due to restricted installation space such as tunnel, etc. and close consideration is required for it. This paper describes the effect of electromagnetic force through results of three phase short-circuit test and electromagnetic force analysis using theoretical calculations and electrical evaluation test after three phase short-circuit test, which will be utilized as basic materials for improvement and development of cleat, hanger, etc. to reduce and release effect of electromagnetic force in the future.

  • PDF

심층신경망을 이용한 비운송 지중구조물의 탄산화속도 예측 모델링 (Modelling on the Carbonation Rate Prediction of Non-Transport Underground Infrastructures Using Deep Neural Network)

  • 윤병돈
    • 한국산학기술학회논문지
    • /
    • 제22권4호
    • /
    • pp.220-227
    • /
    • 2021
  • 비운송 지중구조물인 전력구와 공동구는 대부분 철근 콘크리트 구조물로서 공용기간이 경과함에 따라 탄산화에 의한 열화로 내구성이 저하된다. 특히, 전력구 및 공동구는 용도별, 지역별로 탄산화 속도가 상이하므로 개별적인 유지관리를 위해서는 탄산화 실측 데이터에 기반한 예측 모델이 요구된다. 본 연구에서는 노후화 된 전력구 및 공동구와 같이 기존 비운송 지중구조물에 대한 탄산화 예측 모델을 개발하였다. 탄산화 예측 모델 개발을 위해 안전점검에서 확보한 실측 데이터를 기반으로 다중회귀분석 및 심층신경망 기법을 활용하였다. 다중회귀분석에서 종속 변수인 탄산화 속도계수 결정을 위해 독립 변수로서 구조물, 지역, 측정 위치, 시공 유형, 측정 부재, 콘크리트 강도를 선정하였으며, 다중회귀 예측 모델의 수정결정계수(Ra2)는 0.67로 분석되었다. 심층신경망을 이용한 비운송 지중구조물의 탄산화 예측 모델결정계수(R2)는 0.82로 나타났으며, 비교대상 모델보다 우수한 예측 성능을 보였다. 심층신경망을 이용한 비운송 지중구조물의 탄산화 예측 모델은 콘크리트 강도에 기초한 것으로, 본 연구의 결과가 노후화 된 전력구 및 공동구에 대한 탄산화 유지보수 최적 시기 결정 및 예방적 유지관리 방법론에 기여되길 기대한다.

실대형 하중재하 시험 및 현장계측을 통한 쉴드터널 세그먼트 안정성 분석 (Stability analysis of shield tunnel segment lining by field measurement and full scale bending test)

  • 이규필;장수호
    • 한국터널지하공간학회 논문집
    • /
    • 제21권5호
    • /
    • pp.611-620
    • /
    • 2019
  • 쉴드터널은 직경 3~4 m 규모의 전력구 등에 주로 적용되었으나, 최근 직경 7~8 m 규모의 쉴드터널이 인천국제공항 활주로 하부에 시공되었으며, 한강 하저구간 도로 및 철도터널 시공완료 및 계획중에 있다. 쉴드터널 단면이 증가함에 따라 세그먼트 또한 대형화되고 있으며, 이로 인하여 세그먼트의 설계, 시공 및 성능평가 시 여러 문제점이 야기되고 있다. 따라서 본 연구에서는 직경 약 8 m 규모의 쉴드터널에 대한 현장계측 및 실대형 하중재하 시험을 통하여 쉴드터널 세그먼트 라이닝 구조적 안정성 분석, 축력을 고려한 세그먼트 사용성 검토방안의 적합성 및 품질관리 방안에 대하여 검토하였다.

전력구 터널 건설안전 확보를 위한 디스크커터 마모측정시스템 시작품 개발 및 성능검증 (Development of disc cutter wear sensor prototype and its verification for ensuring construction safety of utility cable tunnels)

  • 김정주;류희환;송승우;도승철;이지윤;정호영
    • 한국터널지하공간학회 논문집
    • /
    • 제26권2호
    • /
    • pp.91-111
    • /
    • 2024
  • 전력구 터널은 송전선로 지중화 사업의 일환으로 대부분의 경우 쉴드 TBM을 활용하여 건설된다. TBM 챔버는 터널 내부 중 유일하게 암반과 흙을 마주하는 공간이며, 붕락과 부딪힘 사고 등 사고노출 빈도가 가장 높은 곳이다. 현재 챔버 외부에서 디스크커터 마모정도를 측정할 수 있는 방법이 부재하기 때문에 근로자의 수시점검이 필수적이다. 이에 본 연구에서는 TBM 챔버 내부 안전사고를 예방하고, 챔버 오픈회수 절감을 통해 공사기간 단축의 효과를 기대하기 위하여 디스크커터 마모측정 기술 개념을 정립하고, 시작품을 제작하였다. 선행기술을 고찰하여 자기센서가 굴착환경에서 가장 적합하다고 판단하여, 자기센서, 무선통신 모듈, 전원공급, 외부 케이싱, 그리고 모니터링 시스템을 종합한 마모측정 센서 패키지를 개발하였다. 실제 굴착환경에서 시작품 성능검증을 수행하기 위해 3.6 m 토압식 쉴드 TBM을 활용한 실대형 굴진시험을 수행하였다. 실대형 굴진시험 결과 8개의 시작품 중 5개가 정상적으로 작동하였다. 최대 3,000 kN의 추력과 1.5 RPM의 회전속도 안에서 센서측정값이 무선통신을 통해 시스템에 원활하게 표출되는지 확인하였고, 센서 케이싱이 파손되지 않아 내구성을 확보하는 것으로 분석되었다.