• 제목/요약/키워드: Underground Power Line

검색결과 176건 처리시간 0.027초

배전선로 주변에서의 전자계 분포 해석 (Analysis of Electromagnetic Field Around Distribution Line)

  • 권명락
    • 한국전기전자재료학회논문지
    • /
    • 제30권10호
    • /
    • pp.672-676
    • /
    • 2017
  • Electrical energy is playing an increasingly vital role as the primary energy source in everyday life. With the increase in electric power consumption, power facilities are under an increasing stress and must operate at a high capacity. Consequently, the demand for electric power cables in power transmission and distribution lines is rapidly increasing. Underground distribution lines have been steadily replacing the aboveground lines owing to the increase in electric power demand and the need to increase the supply voltage. In addition to line damage, worker safety is of primary concern in this type of underground infrastructure. In this study, to improve the safety of workers dealing with underground transmission lines, we analyzed the electromagnetic field generated around the distribution line and determined the basic criteria for developing a device that can detect a live underground line.

지중 배전계통 적용을 위한 광복합 케이블 실시간 감시시스템 개선 (An Improvement of Optical Fiber Composite Power Cable On-Line Monitoring System for Underground Distribution Network)

  • 조진태;김주용;이학주;박중성
    • 조명전기설비학회논문지
    • /
    • 제26권7호
    • /
    • pp.77-83
    • /
    • 2012
  • Since power system is switching to smart grid, on-line monitoring technology has become necessary for underground distribution power cable. Therefore, the application of DTS(Distributed Temperature Sensing) technology using OFCPC(Optical Fiber Composite Power Cable) capable of monitoring underground distribution power cables has been developed. These can bring about reductions in faults and increases in operating capacity of underground distribution system. To date, the test-bed of optical fiber composite power cable on-line monitoring system has been constructed. Then, matters to be improved have been drawn through verification experiments. This paper presents the improvement and experiment results of the optical fiber composite power cable on-line monitoring system to apply to underground distribution lines in the field.

혼합 배전계통에서 피뢰기적용과 접지시스템 변경을 고려한 서지 해석에 관한 연구 (A Study on the Surge Analysis considering Surge Arrester and Grounding System in the Combined Distribution System)

  • 윤창섭;이종범;김병숙
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 A
    • /
    • pp.204-205
    • /
    • 2006
  • This paper describes the protective ability of lightning arrestor in combined distribution system with power cable. To evaluate the protective ability, change of arrestor and grounding location are considered. On the other hand, arrestor developed by Cooper Power Systems for underground power cable system, is considered to evaluate surge protective ability as in underground system, when arrestor occurs failure has overhead line. The result shows that lightning arrestor in combined distribution system with power cable protect effectively when failure at arrestor in overhead line. On the other hand, arrestor developed by Cooper Power Systems for underground power cable system, is considered to evaluate surge protective ability in underground distribution system, when arrestor of overhead line has failure. The result shows that lightning arrestor installed in underground cable can effectively protected cables from surge when arrestor of overhead line has failure. And also even though grounding locations are decreased, it is revealed that protective ability is nearly similar.

  • PDF

지중송전케이블의 방화대책 (The fire Prevention measures of the underground transmission line)

  • 곽방명;탁의균;김재승
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 A
    • /
    • pp.501-503
    • /
    • 2001
  • Electric power consumption is highly increasing as the social trend requiring comfortable life, the population in a big city and the industrial development. Therefore it has become to be very important to supply the stable high-quality power. As these trend, the underground power transmission facility is highly increasing in the center of a city. As the proportion to increase facility in tunnel, the fire prevention measures of the underground transmission line become very important.

  • PDF

발전소에 포설된 케이블 선로 임피던스 분석 (Line Impedance Analysis of Underground Cable in Power Plant)

  • 하체웅;한성흠
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.612-613
    • /
    • 2007
  • The line impedance is important data that are applied in all analysis fields of electric power system such as power flow, fault current, stability and relay calculation etc. Usually, the impedance can be accurately calculated in case of overhead line. However, in case of power cables or combined transmission lines, the impedance can not be accurately calculated because cable systems have the sheath, grounding wires, and earth resistances. Therefore, if there is a fault in cable system, these terms will severely be caused many errors for calculating impedance. In this paper, the line impedance is measured in a power system of underground cables, and is analyzed by a generalized circuit analysis program, EMTP(Electromagnetic Transient Program), for comparison with the measured value. These analysis results are considered to become foundation of impedance calculation for underground cables.

  • PDF

지중선로 누전점 탐지를 위한 반주기 변조된 대지 펄스 측정 (The measurement of the half period modulated pulse on earth for detection of a underground electric leakage point)

  • 김재현;전정채;유재근
    • 한국산학기술학회논문지
    • /
    • 제12권11호
    • /
    • pp.5123-5127
    • /
    • 2011
  • 증가 추세인 지중 전력설비의 사고 예방과 유지 보수를 위한 기술 연구 개발 요구가 증가하고 있다. 지중선로의 경우 누전 불량의 점유율이 높고 보수도 어려워 정확한 누전점 위치의 탐지가 중요하다. 교류 송신파를 누전점을 가지는 지중선로에 인가하여 발생시킨 교류 대지전위를 측정하여 누전점의 위치를 찾는 방법은 송신파 특정 극성반주기에 교류 대지전위를 동기화하여 비교 판단하여야 한다. 송신파의 특정 극성의 반주기와 동기화하는 기존 방법을 설명하고, 송신파 반주기 변조된 대지 전위 측정 방식을 제안하고 소개하였다. 실험을 통하여 제안한 방식이 구현 가능함을 확인하였다.

지중 2회선 154 kV 송전케이블의 정상 및 지락고장에 따른 전자기력 분포에 관한 연구 (Study on the Distribution of Electromagnetic Force for 154 kV Power Transmission Cable on Dual Underground Lines by Normal and Earth Fault Current)

  • 김희민;김소영;임상현;박관수
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제1권1호
    • /
    • pp.21-27
    • /
    • 2015
  • The goal of this study is the size and distribution of the electromagnetic force generated by the current flowing through the second underground line of 154kV power transmission cables by using electromagnetic finite element analysis. So we interpret how mutually electromagnetic force has an effect on the comparable judgement of Trefoil, Duct and Flat, which shows in a numerical arrangement. 154kV OF 1200SQ Cable 1.281km not only is applicable to modeling for underground transmission cable but also examine the effect of line to line, phase to phase and size and direction of the electromagnetic force preparing for the occurrence of normal state and single-phase earth fault, which are arranged in trefoil, duct and flat formation between sections. As showing how the trajectory, and size distribution of the electromagnetic force translate as the arrangement of the cables when a steady-state current and a fault current flows on the underground cables, I hope that when Underground transmission is designed, this data will be useful information.

지중배전선로의 다회로차단기 운영방안 연구 (The Study of Multi-Circuit Breaker Coordination in the Underground Distribution Line)

  • 조남훈;하복남;이흥호
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제49권4호
    • /
    • pp.143-151
    • /
    • 2000
  • Electric power distribution feeders are susceptible to faults caused by a variety of situations such as adverse weather conditions, tree contacts, equipment failure, accidents, etc. Distribution circuit faults result in a number of problems related to the reliability of service and customer power quality. In the distribution line, the permanent interruption of customer service resulting from a blown fuse or a recloser lockout was the only factor which was used to determine service reliability. On underground distribution line, the serving of cables by earth-moving equipment is a prevalent cause of faults and the most cable faults quickly develop into bolted current. we introduce th multi-circuit breaker coordination methods in the Underground Distribution Line.

  • PDF

지중 저압 전력선의 협대역 전력선통신 채널특성 및 적용성에 대한 연구 (Study on Channel Characteristics and Feasibility of Narrowband Power Line Communication over Underground Low Voltage Power Lines)

  • 유현우;윤경섭;강수경;최인지;박병석;김일한;김원수
    • 한국통신학회논문지
    • /
    • 제38A권10호
    • /
    • pp.874-884
    • /
    • 2013
  • 본 논문은 국내 지중 저압선에 대한 협대역 PLC 기술의 통신 채널 특성과 이를 기반으로 한 적용성 연구결과에 대해 기술한다. 지중 저압선이 매설된 실제 거주지역에 협대역 PLC 채널 측정을 위한 시스템을 구성하였으며, 이를 통해 채널 응답, 잡음 PSD, 선 임피던스를 포함하는 채널 특성을 측정하였다. 측정된 채널 특성을 분석하여 국내 지중 저압선의 채널 특성이 협대역 PLC 적용에 적합한 특성을 띠며, 250kHz 이후 주파수 대역이 특히 양호한 특성을 나타내는 것을 보였다. 이를 기반으로 IEEE P1901.2 규격을 채택, FCC High 대역을 이용하여 네트워크 테스트를 수행하였으며 이를 통해 국내 지중 저압선에 협대역 PLC 기술의 적용이 가능함을 확인하였다.

지증 배전계통을 위한 1선지락 고장거리계산 방법 (A Line-to-ground Cable Fault Location Method for Underground Distribution System)

  • 양하;이덕수;최면송
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 A
    • /
    • pp.329-331
    • /
    • 2005
  • This paper proposes a line-to-ground cable fault location method for underground distribution system. The researched cable is composed of core and sheath. And underground cabke system has been analyzed using Distributed Parameter Circuit. The effectiveness of proposed algorithm has been verified through EMTDC simulations.

  • PDF