• 제목/요약/키워드: Underground Cable

검색결과 470건 처리시간 0.026초

지중배전계통의 뇌과전압 해석 및 뇌써지 보호방안에 관한 연구 (A Study on the Lightning Overvoltage Analysis and Lightning Surge Protection Methods in Underground Distribution System)

  • 김상국;정채균;이종범;하동혁
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 A
    • /
    • pp.558-560
    • /
    • 2003
  • The effects of surge arresters for protection of transmission systems against direct lightning strokes have already been investigated using the digital simulation program EMTP. Distribution lines are spanned on a much large area as compared to transmission lines, and therefore, are more often susceptible to lightning strokes. This paper analyzes the overvoltages on underground cable system against direct lightning strokes to the overhead ground wire using the digital simulation. The effects of lightning protection methods, such as lowering the grounding resistance and installing the surge arrester, for preventing overvoltages on underground cable system caused by direct lightning strokes to the overhead ground wire is investigated. Several schemes have been proposed to protect underground cables. This paper summarizes the main results of a study aimed at analysis of lightning overvoltages in variety underground feeders protected by metal-oxide arresters. This study will provide insulation coordination methods for reasonable system design in 22.9kV underground cable system.

  • PDF

EMTP를 이용한 송전케이블 시스전압 분석 (Underground Transmission Cable Sheath Voltage Analysis Using EMTP)

  • 오동수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 A
    • /
    • pp.428-430
    • /
    • 2000
  • This paper describes under-ground transmission cable sheath voltage by using EMTP and proposes a new design method for calculating cable sheath voltage in steady state. The cross bonding system of power cable is modeled on ${\pi}$ equivalent circuit and the sheath voltage(current) of cable can be analyzed with comparing to conventional method.

  • PDF

방식층 보호장치의 설치에 따른 지중송전케이블 시스 유기전압 해석 (Analysis of Sheath Induced Voltage in Transmission Power Cable Connected with CCPU)

  • 이준성;이종범;김영
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제49권1호
    • /
    • pp.19-25
    • /
    • 2000
  • This paper describes the sheath induced voltage in underground transmission cable system which will be operated with cable cover protection unit(CCPU). Simulation was carried out to analyze the sheath induced voltage in the real cable system which was installed by 154㎸ CV cable in the case with and without CCPU. The sheath induced voltage will be also analyzed according to the change of grounding method, fault resistance and fault angle. Simulation was performed using EMTP and ATP Draw, the simulation results show whether the CCPU in necessary or not in underground transmission power cable system.

  • PDF

밀폐형 방재트러후 개발 (The development of fire protection trough)

  • 황순철;김태경;고창성;한기종;김동배
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1993년도 하계학술대회 논문집 B
    • /
    • pp.1168-1170
    • /
    • 1993
  • EHV underground transmission cable characterized by low loss and bulk capacity should have high reliability to be protected fully from external damages, not to speak of its quality. In 345kV underground transmission lines of our country, the usage of frie protection trough is standardized. Fire protection trough consists of combination of trough body, spacer, shutting board, fastener, and etc. and it is required to have a high level of fire-retardant characteristics and mechanical strength. Since 1992, we, GoldStar Cable, with collaboration of Lucky, have participated in the development of fire protect ion trough and completed the type test of manufacturing site and will be supposed to go into mass product within 1993.

  • PDF

이상대 판정기법을 활용한 지하매설물 탐사 (Exploration of underground utilities using method predicting an anomaly)

  • 류희환;김경열;이강렬;이대수;조계춘
    • 한국터널지하공간학회 논문집
    • /
    • 제17권3호
    • /
    • pp.205-214
    • /
    • 2015
  • 급격한 도시화 및 산업화는 전력구를 비롯한 공동구의 수요를 증가시키고 있다. 하지만 기존 지하매설물, 특히 전력구에 대한 불충분한 정보와 지하매설물의 무분별한 건설로 인해 최근 도심지 내 새로운 지하매설물을 건설하는 것이 매우 어렵다. 뿐만 아니라, 전력구를 비롯한 지하매설물이 건설된 위치와 방향에 대한 부족한 정보는 신규 지하매설물의 계획노선을 설정하는데 많은 문제를 야기시키고 있다. 이러한 문제를 해결하기 위해서 본 연구에서는 기존의 전기비저항 탐사방법과는 다른 이론적 방법으로 해결하고자 하였다. 전력구를 비롯한 지하매설물이 건설된 지반에서 가우스 법칙과 라플라스식을 이용하여 전기장 해석이 수행하였다. 전력구의 방향, 전력구의 위치, 전력구의 전기전도도 등의 함수로 표현된 전기비저항 이론식은 전기장해석을 통해서 획득하였다. 이론식을 검증하기 위해서 현장실험이 수행되었으며 현장실험 결과, 지반 내 지하매설물의 위치와 방향을 오차범위 내에서 예측하였다.

도전성 및 자성 차폐체의 차폐효과 해석과 차폐인수 산정 (Analysis of Shielding Effectiveness and Estimation of Shielding Factor in Conductive and Magnetic Shields)

  • 강대하
    • 조명전기설비학회논문지
    • /
    • 제27권10호
    • /
    • pp.30-40
    • /
    • 2013
  • In this study the method based on flux linkage in cell was introduced in calculation of eddy currents by cell method. According to this method eddy current distribution and the loss can be evaluated and since the shielding effectiveness by flux cancelation of eddy current can be analyzed, this method is applicable to design of conductive shield. And also the formula of shielding factor were so deduced as to be applicable to finite-width infinite-length shielding sheets and infinite-length underground cable shield. These formula are adaptable to magnetic materials as well as conductive materials. As the results of calculation in model shields are follows. In case of finite-width infinite-length shielding sheet, shielding effectiveness increases with increasing of conductivity. In case of infinite-length underground cable shield, the effectiveness become higher with increasing of permeability. Especially the effectiveness is very high in materials with both high conductivity and permeability in underground cable shield.

간접냉각이 이용된 지중송전케이블의 적정냉각조건에 관한 연구 (A Study on the Optimum Cooling Condition of the Underground Power Transmission Cable Equipped with a Separate Pipe Cooling System)

  • 박만흥;최규식;서정윤;김재근;이재헌
    • 설비공학논문집
    • /
    • 제4권4호
    • /
    • pp.263-276
    • /
    • 1992
  • The transmission current in a power cable is determined under the condition of separate pipe cooling. To this end, the thermal analysis is conducted with the standard condition of separate pipe cooling system, which constitutes one of the underground power transmission system. The changes of transmission current in a power cable with respect to the variation of temperatures and flow rates of inlet cooling water as well as the cooling spans are also determined. As a consequnce, the corresponding transmission current is shown to vary within allowable limit, resulting in the linear variation of the current for most of the cable routes. The abrupt changes of current, however, for the given flow rate of inlet cooling water in some cooling span lead to the adverse effects on the smooth current transmission within the underground power transmission system. In practice, it is expected that the desinging of the separate pipe cooling system in conjunction with the evaluation of system capacity should take into account the effects of design condition on the inlet cooling flow rate.

  • PDF

지중송전케이블계통에서 절연통의 과전압 해석 및 억제대책 검토 (Analysis of Overvoltage and Reduction Methods of Insulation Joint Box in Underground Power Cable Systems)

  • 홍동석;정채균;이종범;서재호;조한구
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제51권2호
    • /
    • pp.102-108
    • /
    • 2002
  • This paper describes the overvoltage analysis and reduction methods of insulation joint boxes in underground transmission power cables when direct lightning surge strikes to overhead transmission line. An actual 154kV combined transmission line with underground Power cables was modelled in ATPDraw for simulation. Simulations were performed to analyze the overvoltage between insulation joint boxes, sheath-to-ground voltage according to the distance between cable conductors, cable lengths, burying types, CCPU connection types. The most effective method to reduce the induced overvoltage of Insulation joint boxes was proposed. It is evaluated that the proposed reduction method riven from the detailed simulations can be effectively applied to the actual underground power cable systems.

시간-주파수 영역 반사파 계측법 기반 활선 상태 지중 전력 케이블의 중성선 결함 위치 추정 연구 (Localization of Concentric Neutrals Corrosion on Live Underground Power Cable Based on Time-frequency Domain Reflectometry)

  • 이춘구;윤태성;박진배
    • 전기학회논문지
    • /
    • 제62권2호
    • /
    • pp.239-245
    • /
    • 2013
  • In this paper, we propose a time-frequency domain reflectometry (TFDR) based measurement method for localizing concentric neutrals corrosion on live underground power cable. It consists of two inductive couplers which can transmit the reference signal into live underground power cable and measure the reflected signals from the impedance discontinuities of concentric neutrals corrosion. In order to compensate the dispersion of the measured reflected signal via inductive coupler, an equalizer based on Wiener filtering is designed. To improve the localizing performance of concentric neutrals corrosion in the vicinity of the measurement point, the reference signal is removed from the measured reflected signals. The localization performance of the proposed method is verified by the concentric neutrals corrosion localization experiment.

154kV 지중케이블 서지 보호장치용 ZnO 소자의 전기적 특성 (Electrical Characteristics of ZnO element to Surge protector for 154kC Underground Cable)

  • 조한구;한동희;김석수;이종혁;장태봉
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 하계학술대회 논문집
    • /
    • pp.1054-1056
    • /
    • 2001
  • This paper deals with underground transmission system of present and ZnO element of newly developed. in the characteristics of ZnO element of newly developed, an newly developed ZnO element compared with previous ZnO element that electrical characteristics and external characteristics. In result, characteristics of newly developed ZnO element is improved than previous one.

  • PDF