• 제목/요약/키워드: Underground Cable

검색결과 470건 처리시간 0.03초

초고압 CABLE 감시시스템 연구 (Surveillance System For Extra High Voltage Cable)

  • 한기만;이광철;전승익;김충식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1992년도 하계학술대회 논문집 B
    • /
    • pp.789-793
    • /
    • 1992
  • For improving the power supply reliability and minimizing maintenance work of E.H.V. underground transmission line, new surveillance systems are strongly desired for use in the field of electric power transmission. For underground installation, high system reliability is required because E.H.V. cables, if an accident happen, can have a serious impact on social activities and human life. In answer to this requirement, applications of optical fiber transmission system have been widely developed in a variety of field. The main function of this system are cable fault location, oil leak detection, and surveillance of the cable circuit and tunnel condition.

  • PDF

161kV XLPE CABLE용 Prefabricated joint의 실선로 적용 (The Installation of Prefabricated Joint for 161kV XLPE Cable Underground Transmission Line)

  • 봉원국;장기욱;이헌상;오종옥
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 E
    • /
    • pp.1611-1613
    • /
    • 1998
  • The new type of prefabricated joint for 161kV XLPE cable have been developed. we, LG Cable & Machinery Ltd., made an huge contract with an foreign country's Power company for the supply of cable and accessories, the training of jointing and termination work to local personnel, technical assistance by joint venture and the supervision of installation and commissioning. By the end of 1997, one of several routes under the contract successfully finished being constructed and specially tested on site. In operation, now this underground transmission line proves well the reliability and efficiency of prefabricated joint and termination applied first time in foreign country.

  • PDF

C/H 철탑 종단접속함 보호용 피뢰기 리드선 길이에 따른 뇌과전압 분석 (Analysis on Lightning Overvoltage According to Lead Length of Surge Arrester for Underground Cable Outdoor Termination Protection at C/H Tower)

  • 정채균;강지원
    • 전기학회논문지
    • /
    • 제65권2호
    • /
    • pp.257-263
    • /
    • 2016
  • This paper describes the lightning arrester transients in cable head termination. The installation references of cable head tower and lightning arresters are firstly reviewed, then the performance of lightning arrester operation is also evaluated based on lightning overvoltage analysis by the change of grounding lead cable length. This paper finally proposes the optimal length of grounding lead cable at the cable head termination. The limited lightning current is also proposed according to the change of grounding lead cable length. The results will contribute to protecting insulation breakdown failure against lightning surge at the terminations and joints.

시스 순환전류 저감장치의 개발 및 전기적 특성 검토 (Development of Restraining-unit of Sheath Circulating Current and Its Electrical Characteristics)

  • 하체웅;김정년;김동욱;강지원;김재승
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 A
    • /
    • pp.394-396
    • /
    • 2004
  • In order to reduce the sheath circulating current, same arrangement and balanced length of cable are required for the underground cable system. But practically, changing the whole arrange of cable which is already constructed is impossible. Therefore, It is necessary to apply the restraining-unit of sheath circulating current at the cross-bonding wire of insulated joint because the impedance of restraining-unit is able to reduce sheath circulating current at a normal condition. Even at a transient state, the restraining-unit must maintain electrical and mechanical characteristics. In this paper, the features of restraining-unit developed by LG Cable as well as the electrical test results are described. It proves that the restraining-unit is applicable to the underground cable system where sheath circulating current rises.

  • PDF

지중케이블 활선검출기를 위한 자장 센서 개발 (Development of Magnetic Sensor for Live Line Detector of the Underground Cable)

  • 김기준;오용철;이경섭;정한석;김탁용;최미희;송민영;신철기;김진사
    • 한국전기전자재료학회논문지
    • /
    • 제24권2호
    • /
    • pp.166-171
    • /
    • 2011
  • We use the electrical energy and it is essential energy in modern life, but we lay cable underground due to the issue for environment and safety. Safety for worker is still insufficient for the development of safety equipment and related research has been focused on the cable lifetime diagnosis at underground cable work. I have to develop live line detector around the magnetic field were investigated at underground cable. In this paper, we were investigated by variation of coil turns and load due to detection of magnetic field at lines around. And detected value of developing products compared with measured value of milli-gauss meter. As a result, the value of the number of coil turns was found to be proportional to the measured value. But turn-numbers increase showed that the weak noise. I could be confirmed that sensor showed the optimum value from 4,000 to 5,0000.

OF 케이블 계통 과도상태 열특성 해석 및 평가 (Analysis and Estimation of the Transient Thermal Characteristics of OF Cable systems)

  • 강지원;이동일;정채균;이종범
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제54권10호
    • /
    • pp.487-495
    • /
    • 2005
  • This paper reviews the characteristic of thermal and temperature of oil field cable in transient state such as grounding fault and lightning surge. For analysis in various conditions, many actual underground power cable systems are modeled using ATP. These results are applied for the examination of temperature increase when the single line to ground fault by the breakdown of insulation part and hitting of lightning surge are occurred. The inner part temperature of OF cable is analysed according to the various kinds of cable using the thermal model of transient state. The temperature increase of sheath and crossbonded lead bv fault current is also analysed using IEC 60949.

OF 케이블 계통에서 과도상태시 에너지 특성 검토 (A Study on Energy Characteristics in Transient States of OF Cable Systems)

  • 정채균;이종범;강지원;이동일;서재호
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제55권11호
    • /
    • pp.468-475
    • /
    • 2006
  • This paper reviews the energy characteristics of oil filled cables in transient state such as grounding fault and lightning surge. Artificial grounding fault test was firstly performed in 2003 for the analysis of arc voltage and breakdown energy according to the fault current. In this paper, energy of OF cable is variously analysed at joint box based on the actual test. Then more various conditions such as installation types, section lengths and CCPU(Cable Covering Protection Unit) connection types are applied for the simulation using EMTP when the single line to ground fault and direct lightning stroke are occurred on actual underground power cable systems and combined power cable systems, respectively. Finally, the energy by the length of crossbonded lead and grounding lead as well as fault lasting time is also calculated using EMTP simulation.

혼합배전계통 선로구성요소 변화를 고려한 선로 서지해석 (Surge Analysis Considering Variation of Line Configuration Factor in Combined Distribution Systems with Power Cables)

  • 김병숙;이장근;한병성;이종범
    • 전기학회논문지
    • /
    • 제56권3호
    • /
    • pp.472-480
    • /
    • 2007
  • This paper analyzes overvoltage on testing line for various parameter effect examination. Model systems consist of overhead line and underground cable. The model considered actual characteristic data of distribution lines. and will be constructed at testing yard. The simulations were performed under various line configuration such as cable kinds, cable length, lightning wave, lightning wave time, transformer and branch circuits. The simulation models are established by EMTP/ATPDraw and Line Constants are calculated by ATP_LCC. When lightning surge strikes on conductor of overhead line, EMTP/ATPDraw calculates overvoltage in many cases. Simulation results will be compared with real testing results at testing yard. The compared results will be used to establish protection methods in actual underground distribution systems.

지중송전선로와 병행하는 기설통신선의 유도전압 분석 (Analysis of Induced Voltage in Parallel Telecommunication Cables from Underground Power Cables)

  • 임광식;장우석;한창석;홍동석;유진선
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.523-524
    • /
    • 2011
  • This paper covers induced voltage in parallel telecommunication cable with underground power cable to be linked between substations. The simulation was carried out the induced voltage in telecommunication cable according to the transposition of power cables and fault location for various conditions. This study based on the EMTP/ATPDraw with actual underground cable systems while the power cables are in steady state and transient state.

  • PDF

EMTP를 이용한 광 복합 지중송전케이블 광 유니트 금속관의 시스템 영향분석 (Analysis on System Effects of SUS Tube in Optical Fiber Composite Power Cable Systems Using EMTP)

  • 정채균;장태인;강지원
    • 전기학회논문지
    • /
    • 제63권9호
    • /
    • pp.1180-1185
    • /
    • 2014
  • This paper describes the effects on SUS tube of power optical fiber composite cable on underground transmission lines. The effects on grounding, air gap between SUS tube and metal sheath, contact resistance between outer semi-conducting layer and metal sheath and grounding of SUS tube application or not are variously analysed using EMTP in normal operating condition as well as single line to ground fault. From these results, in this paper, the scheme for protecting the electrically abnormal phenomena will be established on power-optical fiber composite cable of underground transmission lines. This paper can contribute to specification of grounding reference of SUS tube of optical fiber composite power cable system.