• 제목/요약/키워드: Unbalance distribution system

검색결과 91건 처리시간 0.027초

PSCAD/EMTDC와 FEA를 이용한 케이블 배열 방법에 따른 전류 불균형률의 비교 (The Comparison of the Current Unblance Factor According to the Cable Array Method using PSCAD/EMTDC and FEA)

  • 신호전;김지호;강갑석;김재철;이향범
    • 전기학회논문지P
    • /
    • 제62권2호
    • /
    • pp.72-78
    • /
    • 2013
  • In this study, samples from the site where there occurred unbalanced current when cable routing were analyzed, and the simulation program for electric power system analysis, PSCAD/EMTDC, was used to calculate the current unbalance on cable routing. Based on electromagnetic finite element analysis(FEA), electromagnetic parameters enabled the interlocking with COMSOL for the calculation of allowable current ampacity and magnetic filed distribution. This then led to modeling unbalanced current between common modes using the unbalanced current analysis program, thereby comparing and discussing the results from both. The analyzed model is a common mode 2 parallel circuit, which is a basic model for cable routing, and by arranging cables in various ways, the arrangement with the least current unbalance was suggested, which would, in the future, prevent earth faults and extend life for the whole cable.

직렬주입변압기가 없는 새로운 UPQC(Unified Power Quality Conditioner)의 성능분석 (Operation Analysis of Novel UPQC(Unified Power Quality Conditioner) without Series Injection Transformers)

  • 김희중;배병열;전영수;한병문;김현우
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2003년도 춘계전력전자학술대회 논문집(1)
    • /
    • pp.251-255
    • /
    • 2003
  • This paper proposes a novel UPQC(unified power quality conditioner) based on H-bridge modules, isolated through single-phase multi-winding transformers. The dynamic performance of proposed system was analyzed by simulation with EMTDC/PSCAD, assuming that the UPQC is connected with the 22.9kV distribution line. The proposed system can be directly connected to the transmission line without series injection transformers. It has flexibility in expanding the operation voltage by increasing the number of H-bridge modules and can compensate reactive power, harmonics, voltage sag and swell, voltage unbalance. The control strategy for the proposing UPQC was derived using the instantaneous power method. The proposing UPQC has the ultimate capability of improving power quality at the point of installation on power distribution systems and can be utilized for the future distribution system.

  • PDF

접지방식이 상이한 철도배전계통의 연장급전을 위한 전기적 특성분석 (Analysis of electric characteristics for extension power supply between different grounding railway distribution system)

  • 정호성;한문섭;이장무;권삼영;박현준
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2005년도 추계학술대회 논문집
    • /
    • pp.736-741
    • /
    • 2005
  • This paper presents electric characteristics analysis and safe configuration for extension power supply between existent 6.6kV ungrounded distribution system and establishment and improvement 22.9kV direct grounding distribution system. For this, we model 6.6kV ungrounded and 22.9kV direct grounding distribution system of urban underground, ground region. and rural electrical, unelectrical region using PSCAD/EMTDC and analyze voltage drop, charging current, ground and short fault through simulation. To analyze electric characteristics of extension power supply, we simulate extension power supply of overhead line of 6.6kV ungrounded system and underground line of 22.9kV direct grounding system of rural electrical region and propose operation condition for safe extension power supply through result of analysis. Characteristics of voltage drop, charging current, ground and short fault appear almost similarly with electrical characteristic of direct power supply. However, because unbalance of phases may cause relay's malfunction of ungrounded system and ground fault current of direct grounding system may demage facilities of ungrounded system, we propose safe system configuration such as impedance grounding system of neutral point.

  • PDF

연속용융아연 도금라인의 도금편차 진단 (Diagnosis of Coating Deviation in Continuous Galvanizing Line)

  • 배용환
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제26권2호
    • /
    • pp.192-199
    • /
    • 2002
  • In continuous galvanizing process, the mass of zinc deposited and its distribution are controlled by the air pressure, effective distance from the air knife nozzle to the steel strip surface and line speed. Coating defects are resulted from the unbalance of these control factors and the inaccuracy of coating equipments. This paper investigates the main cause of coating deviation and a new air knife system for control of coating thickness was developed. We investigate dynamic pressure variation by air knife types. It is found that the coating deviation is caused by the unbalance of dynamic pressure, the irregularity of strip position, and the strip vibration. Formulating a useful coating model by using present working condition, an optimal working condition is suggested. The productivity and coating quality are improved by applying the result of this research at the shop floor.

저항성 및 유도성 부하의 운전시 전압불평형율의 비교 (Comparison of VUF using Resistor & Inductive Load)

  • 김종겸;박영진;이은웅;이종한;이동주
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 B
    • /
    • pp.1062-1064
    • /
    • 2005
  • 3 phase 4-wire system has been widely used in the customer's application due to merit of 1 bank construction of loads such as 1-phase lighting, heat and 3-phase motor. But if the load distribution is not uniformed by the operation conditions, voltage unbalance is highly appeared by the difference of each phase current value. Especially, if the linear load such as resistance or inductive load has different power factor value, voltage unbalance factor is not the same due to the phase angle and magnitude of each phase voltage. In this paper, we composed the measurement device and analyzed by varying of load pattern.

  • PDF

급전회로망 해석기법을 활용한 전철계통 해석 (Train voltage analysis of railroad system using supply network method)

  • 윤재영;최흥관
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2000년도 춘계학술대회 논문집
    • /
    • pp.108-115
    • /
    • 2000
  • This paper presents the new simulation algorithms using network methods to analysis the steady-state train voltage distribution characteristics in ac auto-transformer fed railroads. In general, the supply system of railroads is composed of non-symmetrical and unbalance transmission line. Therefore, the general method using simplified old algorithms have the self-contradictory errors because the supply line of train railroads is completely unbalanced. In this paper, the simulation results of new developed algorithms is compared with those of EMTP to confirm the effectiveness.

  • PDF

High-Performance Control of Three-Phase Four-Wire DVR Systems using Feedback Linearization

  • Jeong, Seon-Yeong;Nguyen, Thanh Hai;Le, Quoc Anh;Lee, Dong-Choon
    • Journal of Power Electronics
    • /
    • 제16권1호
    • /
    • pp.351-361
    • /
    • 2016
  • Power quality is a critical issue in distribution systems, where a dynamic voltage restorer (DVR) is commonly used to mitigate the voltage disturbances for loads. This paper deals with a nonlinear control for the three-phase four-wire (3P-4W) DVR under a grid voltage unbalance and nonlinear loads in the distribution system, where a novel control scheme based on the feedback linearization technique is proposed. Through feedback linearization, a nonlinear model of a DVR with a PWM voltage-source inverter (VSI) and LC filters is linearized. Then, the controller design of the linearized model is performed by applying the linear control theory, where the load voltages are kept constant by controlling the d-q-0 axis components of the DVR output voltages. To keep the load voltage unchanged, an in-phase compensation strategy is employed, where the load voltages are recovered to be the same as the previous voltage without a change in the magnitude. With this strategy, the performance of the DVR becomes faster and more stable even under unbalanced source voltages and nonlinear loads. The validity of the proposed control strategy has been verified by simulation and experimental results.

다발 원통형 그레인을 사용한 가스발생기의 저주파 연소불안정 소멸에 대한 실험적 연구 (Experimental Study on the Suppression of low Frequency Unstable Burning Occurred in a Gas Generator Using Bundle Cylindrical Grain)

  • 성홍계;변종렬
    • 한국추진공학회지
    • /
    • 제8권3호
    • /
    • pp.10-16
    • /
    • 2004
  • 원통 다발형 그레인의 연소시험 결과 저주파 불안정 현상이 나타났다. 그 원인은 원통 그레인 내면의 압력과 외면의 압력차(압력 비평형)가 주원인임을 알 수 있었으며, 그레인 반경방향으로 홀을 뚫어 그레인 내면에 상승된 압력을 외면으로 빠르게 확산되도록 하여 안정된 연소현상을 얻을 수 있었다. 그러나 고온 조건에서도 안정된 연소 현상을 얻기 위하여 직경 3mm 흘 7개를 뚫게 됨에 따라 가스발생량의 증가가 많이 둔화되어 격자를 사용하는 방법을 연구하게 되었다. 격자를 사용함으로써 큰 와류(large vorticity)를 소멸시켜 그레인에 홀을 뚫지 않고도 안정된 연소를 얻을 수 있었으며 가스 발생량도 점진적으로 증가시킬 수 있었다. 가로${\times}$세로 격자는 5${\times}$5, 그레인은 격자에 고정시키지 않을 때 가장 좋은 결과를 얻을 수 있었다.

순간정전에 대한 보상능력을 갖는 UPQC(Unified Power Quality Conditioner)의 성능해석 (Performance Analysis of UPQC(Unified Power Quality Conditioner) with Compensation Capability for Voltage Interruption)

  • 김희중;배병열;한병문;설승기;조보형
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제52권5호
    • /
    • pp.279-286
    • /
    • 2003
  • A new UPQC(unified power quality conditioner), which consists of series inverter, shunt inverter, dc/dc converter, and energy storage, is proposed. The proposing UPQC can compensate reactive power, harmonics, voltage sag and swell, voltage unbalance, and voltage interruption. The control strategy for the proposing UPWQC was derived using the instantaneous power method. The performance of proposing system was analyzed by means of the EMTDC/PSCAD simulation and the experimental work with the hardware prototype. The proposing UPQC has the ultimate capability of improving power quality at the point of installation on power distribution systems or industrial power systems and can be utilized for the custom power device in the future distribution system.

DVR 기능을 갖는 3상 하이브리드형 직렬 능동전력필터 (3-Phase Hybrid Series Active Power Filter with Dynamic Voltage Restorer)

  • 한석우;최규하
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2002년도 전력전자학술대회 논문집
    • /
    • pp.598-602
    • /
    • 2002
  • This paper presents the 3-phase hybrid series active power filter with dynamic voltage restorer(DVR) which serve as an energy buffer and current harmonics blocking resistor connected to sensitive loads, such as, to compensate voltage dips and current harmonics in power distribution system. The DVR is to inject a dynamically controlled voltage generated by a forced commutated converter in series to the bus voltage by means of a booster transformer. The momentary amplitudes of the three injected phase voltages are controlled such as to eliminate any detrimental effects of a bus fault to the load voltage. The proposed system is able to simultaneously compensate current harmonics, voltage fluctuating and voltage unbalance in power distribution systems. The reference phase angle detected by synchronized with the positive sequence component of the unbalanced source by using symmetrical component transformation. The effectiveness of proposed system is verified by the computer simulation.

  • PDF