• Title/Summary/Keyword: Ultrasound treatment

Search Result 678, Processing Time 0.032 seconds

Comparison of the Effect in ROM Increase and Pain Reduction on Stretching During Ultrasound Treatment in Patients With Frozen Shoulder (동결견 환자의 초음파치료 시 신장여부에 따른 관절가동범위 회복과 통증감소 효과 비교)

  • Yang, Hoe-Song
    • Physical Therapy Korea
    • /
    • v.10 no.1
    • /
    • pp.129-137
    • /
    • 2003
  • A single subject experimental design (alternating treatment design) was used to compare the effects of only ultrasound and ultrasound combined with stretching of the joint capsule on the ROM increase and pain reduction in patients with frozen shoulder. Two subjects were included in each group. In the only ultrasound treatment sessions, ultrasound was applied at the pain point of the shoulder joint in supine position. In the ultrasound combined with stretching treatment sessions, ultrasound was applied at the pain point of the shoulder joint positioned in external rotation and abduction in sitting position. Only ultrasound treatment and ultrasound combined with stretching treatment were alternately performed on each patient. Pain and disability was measured by shoulder pain and disability index (SPADI), and range of motion (ROM) was measured by scratch test. The results of this study showed that ultrasound combined with stretching treatment were more effective than only ultrasound treatment in ROM increase and pain reduction. However, disability score was not significantly different.

  • PDF

Effect of ultrasound treatment on the quality properties of chicken breast meat and the broth from Korean chicken soup (Baeksuk)

  • Jung, Samooel;Jo, Kyung;Lee, Sunmin;Choi, Yun-Sang
    • Korean Journal of Agricultural Science
    • /
    • v.46 no.3
    • /
    • pp.539-548
    • /
    • 2019
  • This study investigated the influence of ultrasound treatment on the quality properties of chicken breast meat and the broth from Korean chicken soup (Baeksuk). In this study, the internal temperature, malondialdehyde content, textural profile, color, dry matter, protein content, phenolic content and sensory properties of chicken breast meat broth from chicken soup with ultrasound treatment were analyzed. The chicken, plants, salt, and water were vacuum packaged in a retort pouch. The chicken soup was manufactured with ultrasound treatment (45 kHz and $1.6W\;cm^{-2}$) in a water bath at $85^{\circ}C$. The texture properties, color, and lipid oxidation of the chicken breast meat from the chicken soup were not affected by the ultrasound treatment. There was no significant difference in the lipid oxidation in the broth of the chicken soup between the control and ultrasound treatment. The dry matter and crude protein contents of the broth were significantly increased by the ultrasound treatment. The broth flavor of the chicken soup manufactured with the ultrasound treatment received a higher score than that of the control in the sensory analysis. There were no differences in the sensory properties of the chicken breast meat from the chicken soup between the control and ultrasound treatment Therefore, the broth quality of the chicken soup can be improved by heating with ultrasound treatment. Additionally, to apply ultrasound technology to the production chicken breast meat and the broth from chicken soup, it is necessary to further study the quality characteristics of the breast meat and broth according to various frequencies and strengths.

The Effects of the Ultrasound on Treatment of Chronic Sinusitis (초음파를 이용한 만성 부비동염의 치료연구)

  • Hur, Sung-Gwi;Lim, Weon-Sik;Bae, Sung-Soo
    • The Journal of Korean Physical Therapy
    • /
    • v.14 no.1
    • /
    • pp.55-62
    • /
    • 2002
  • The purpose of this study was to determine the effects of the ultrasound on treatment of chronic sinusitis. 24 persons of men and women with chronic sinusitis divided into three groups of each 8 persons randomly and when were they were treated with the medication, the ultrasound(1MHz continuous wave, 1W/$cm^2$ intensity, three times per a week and once of three minutes circular stroke method) and the medication+ultrasound for 2, 4, 6 and 8 weeks. The results of this study were ad follows. 1. There was not statistical significant differences between the effects of treatment until two weeks(P>.05). 2. There was statistical difference between the effects of treatment after 4 weeks, 6 weeks and 8 weeks(P<.05). There was statistical significant difference between the group with ultrasound treatment and the group with ultrasound+medication treatment and there was statistical significant difference between the group with medication treatment and the group with ultrasound+medication treatment but there was not statistical significant between the group with ultrasound treatment and the group with medication treatment. 3. After 4 weeks, the highest effect for chronic sinusitis was group

  • PDF

Effects of Water or Brine Immersion Thawing Combined with Ultrasound on Quality Attributes of Frozen Pork Loin

  • Hong, Geun-Pyo;Chun, Ji-Yeon;Jo, Yeon-Ji;Choi, Mi-Jung
    • Food Science of Animal Resources
    • /
    • v.34 no.1
    • /
    • pp.115-121
    • /
    • 2014
  • This study explored the effects of water or brine (2% NaCl, w/v) immersion thawing combined with ultrasound treatment (40 kHz, 150 W) on the quality characteristics of pork. Ultrasound treatment of pork was conducted in two cold media (at $4^{\circ}C$), water and 2% (w/v) brine, respectively. Because the ultrasound treatment caused temperature increase in the media from $4^{\circ}C$ to $16^{\circ}C$, the qualities of pork thawed by ultrasound were compared with those thawed by immersion either in water or brine where the temperature was being maintained at either $4^{\circ}C$ (low temperature control) or $17^{\circ}C$ (high temperature control). The ultrasound treatment resulted in rapid thawing of pork where the thawing rate was similar to those thawed in the $17^{\circ}C$ media. For quality characteristics, ultrasound-treated pork in brine had an advantage of less cooking losses when comparing to the control. In particular, ultrasound treatment in brine exhibited the lowest shear force (or highest tenderness) among the freezing/thawing treatments. Although the ultrasound processing in brine caused discoloration of the pork, this thawing technique had potential to be applied as a commercial thawing technology for frozen foods.

The Effects of Kettlebell Exercise and Ultrasound Treatment on Body Mass Index and Percent Body Fat in 20's Adults (케틀벨 운동과 초음파 치료가 20대 성인의 체질량지수, 체지방률에 미치는 영향)

  • Kim, Hyun-Jin;Kim, Myung-Hoon
    • Journal of Korean Physical Therapy Science
    • /
    • v.25 no.2
    • /
    • pp.1-6
    • /
    • 2018
  • Background: This study was to examine the influence of BMI and PBF of adults in 20's through the Kettlebell exercise and ultrasound for 4 weeks. Methods: 24 adults men and women, whose BMI is over 23, was divided into 3 groups, group I (control group), group II (Kettlebell exercise group), group III (ultrasound treatment and Kettlebell exercise group). The ultrasound treatment was done before exercise for 15 minutes 3 times a week for 4 weeks, and exercise worked out with Kettlebell exercise during 15 minutes and were stretched for 10 minutes before and after exercise. Results: For 4 weeks of Kettlebell exercise and ultrasound, there was a statistically meaningful difference between group I and group III (p<.05). For 4 weeks, there was no statistically meaningful difference of BMI and PBF between group II and group. I Conclusion: A complex application of Kettlebell exercise and ultrasound treatment was thought to effective decreasing for BMI and PBF.

Ultrasound-Guided Radiofrequency Ablation in Tertiary Hyperparathyroidism: A Prospective Study

  • Erya Deng;Tingting Jiang;Huihui Chai;Ning Weng;Hongfeng He;Zhengxian Zhang;Chengzhong Peng;Wenwen Yue;Huixiong Xu
    • Korean Journal of Radiology
    • /
    • v.25 no.3
    • /
    • pp.289-300
    • /
    • 2024
  • Objective: To prospectively evaluate the outcomes of ultrasound (US)-guided radiofrequency ablation (RFA) in tertiary hyperparathyroidism (THPT). Materials and Methods: Patients with THPT underwent RFA between September 2017 and January 2022. Laboratory parameters, including serum intact parathyroid hormone (iPTH) levels, were monitored for 48 months after RFA and compared with the levels at baseline. Complications related to RFA and changes in hyperparathyroidism-related clinical symptoms were recorded before and after RFA. Results: A total of 42 patients with THPT were recruited for this study. Ultimately, 36 patients with renal failure and 2 patients who underwent successful renal transplantation (male:female, 17:21; median age, 54.5 years) were enrolled. The follow-up time was 21.5 ± 19.0 months in the 36 patients with renal failure. In these 36 patients, iPTH levels were significantly decreased to 261.1 pg/mL at 48 months compared with the baseline value of 1284.9 pg/mL (P = 0.012). Persistent hyperparathyroidism, defined as iPTH levels maintained at > 585.0 pg/mL for 6 months after treatment, occurred in 4.0% of patients (1/25). Recurrent hyperparathyroidism, defined as iPTH levels > 585.0 pg/mL after 6 months, were 4.0% (1/25) and 0.0% (0/9) at 6 months and 4 years after treatment, respectively. In two patients with THPT after successful renal transplantation, iPTH decreased from the baseline value of 242.5 and 115.9 pg/mL to 171.0 and 62.0 pg/mL at 6 months after treatment. All complications resolved within 6 months of ablation without medical intervention, except in 10.5% (4/38) patients with permanent hypocalcemia. The overall symptom recovery rate was 58.8% (10/17). The severity scores for bone pain, arthralgia, and itchy skin associated with hyperparathyroidism improved after treatment (P < 0.05). Conclusion: US-guided RFA is an effective and safe alternative to surgery in the treatment of patients with TPTH and improves hyperparathyroidism-related clinical symptoms.

A Study on the Development of High-intensity focused Ultrasound Device for the Beauty Treatment Health Care (미용 치료 헬스케어를 위한 고강도 집속 초음파 장치 개발 연구)

  • Lee, Woo-Cheol;Ko, Yun-Seok
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.11 no.12
    • /
    • pp.1259-1264
    • /
    • 2016
  • Ultrasonic therapy has received great attention in the field of cosmetics related to the treatment of skin thickening because of its fast recovery and safety. In this study, an output circuit of a high intensity focused ultrasound system was developed for the treatment of beauty. To verify the applicability of the high intensity focused ultrasound system to the cosmetic treatment field, we measured and analyzed the 3D ultrasound intensity energy using a hydrophone. And high-intensity focused ultrasound devices were found to be useful for cosmetic treatment.

Effects of ultrasound coupled with potassium permanganate pre-treatment of sludge on aerobic digestion

  • Demir, Ozlem
    • Advances in environmental research
    • /
    • v.5 no.4
    • /
    • pp.251-262
    • /
    • 2016
  • The biodegradability and decomposition efficiencies increase with the pre-treatment of sludge in a digestion process. In this study, the feasibility of ultrasound coupled with potassium permanganate oxidation as a disintegration method and digestibility of aerobic reactor fed with disintegrated sludge with ultrasound coupled potassium permanganate were investigated. The first stage of the study focused on determining the optimum condition for ultrasonic pre-treatment for achieving better destruction efficiency of sludge. The second part of the study, the aerobic digestibility of sludge disintegrated with ultrasound and potassium permanganate oxidation alone and combined were examined comparatively. The results showed that when 20 min of ultrasonic pre-treatment applied, the specific energy output was 49384 kJ/kgTS with disintegration degree of 58.84%. During the operation of aerobic digester, VS/TS ratios of digesters fed with disintegrated sludge decreased indicating that disintegration methods could obviously enhance aerobic digestion performance. The highest reduction in volatile solids was 75% in the digester fed with ultrasound+potassium permanganate disintegrated sludge at the end of the operation compared to digester fed with raw sludge. Total Nitrogen (TN) and Total Phosphorus (TP) levels in sludge supernatant increased with this combined method significantly. Besides, it promoted the production of ${\bullet}OH$, thus enhancing the release of Carbon (C), Nitrogen (N) and Phosphorus (P) from the sludge. Disintegration with all methods used in this study could not improve Capillary Suction Time (CST) reduction in disintegrated digesters during the operation. The results demonstrated that the combined ultrasound treatment and potassium permanganate oxidation method improves the biodegradability compared to control reactor or their single application.

A Study on Efficient Frequency Control of Transducer for Skin Treatment Using Multi-Frequency Ultrasound (멀티주파수 초음파를 사용하는 피부 치료기기 트랜스듀서의 효율적인 주파수 제어 연구)

  • Park, Jong-Cheol;Kim, Min-Sung
    • Journal of Korea Multimedia Society
    • /
    • v.25 no.8
    • /
    • pp.1038-1048
    • /
    • 2022
  • Ultrasound is one of the effective methods for skin treatment. The skin penetration depth of the ultrasound depends on the ultrasonic frequency, that is, when the ultrasonic frequency is high, the depth is shallow. We have developed a transducer which can generate effectively 3 different ultrasonic frequencies removing interference between 3 types of frequencies according to impedance matching technology. The generated powers of transducer are 40.67W at 3.MHz, 17.46W at 11.7 MHz, and 14.79W at 21.5 MHz. The signal interference between the three frequencies is designed so that they do not interfere with each other by separating the signals using the SPDT (Single Pole, Double Throw) switch. The developed hybrid ultrasound transducer can be applied in skin care or skin treatment and beauty therapy.

Ultrasound Contrast Agent (초음파 조영제)

  • Kim, Gi-Wook
    • Clinical Pain
    • /
    • v.20 no.2
    • /
    • pp.86-92
    • /
    • 2021
  • Ultrasound imaging in clinical practice is one of the widely used diagnostic methods because there is no radiation risk, more cost- effective compared to MRI or CT, and possible to perform an intervention through fast real-time imaging. In order to increase the diagnostic value, the studies of contrast-enhanced ultrasound (CEUS) using an ultrasound contrast agent have been actively conducted since about 50 years ago and are being used clinically in vascularity and microcirculation of internal organs. Although ultrasound is actively used for the diagnosis and treatment of various diseases in musculoskeletal disorders, there are some limitations in diagnosing mild or small lesions, inflammatory reactions, or abnormalities at the molecular level. In this review, the principles, types, and research, and clinical applications of ultrasound contrast agents have been summarized and introduced. If we understand the characteristics of the ultrasound contrast agents and anatomical knowledge, as well as molecular changes, the ultrasound contrast agents are widely applied in musculoskeletal disorders and have tremendous potential for diagnosis and treatment.