Study on Detectability and Sizing for Incilned Planar Reflectors by Ultrasonic Testing (초음파를 이용한 경사진 반사체의 검출능력 및 크기 평가에 관한 연구)

  • Hong, S.S.;Kwak, K.J.;Park, J.H.;Park, D.Y.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.5 no.2
    • /
    • pp.34-41
    • /
    • 1986
  • The ultrasonical characteristics of inclined planar reflectors is investigated by the maximum amplitude method. The reflected ultrasound is varied by the reflector size, shape, inclination and using transducers. It was found that the detecting ability for planar reflectors was decreased with increasing transducer size and misorientation angle and increased with decreasing ultrasonic frequency, also the misorientation angle of planar reflectors affected significantly for the measurement of refklector size.

  • PDF

Ultrasound thermometry using narrow band transducer (협대역 변환기를 이용한 초음파 온도측정)

  • 송성욱
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • 1998.06e
    • /
    • pp.251-254
    • /
    • 1998
  • 초음파 수신 신호의 공진주파수 변화를 이용한 온도 측정법에서 협대역 변환기를 사용한 초음파 온도측정이 가능함을 보여준다. 그리고 이를 위하여 공진주파수 변화와 온도변화간의 비례상수를 변화시켰다. 기존의 측정법은 온도변화와 기본주파수 변화와의 관계를 비례상수로 정의하였기 때문에, 최소한 3개 이상의 하모닉을 포함하는 광대역 변환기가 필요하였다. 하지만 협대역 변환기를 이용한 온도측정법에서는 비례상수를 주파수 변화비와 온도변화간의 관계로 나타내기 때문에 한 성분의 하모닉만을 측정하여도 온도측정이 가능하게 된다.

  • PDF

Study on In Vitro Bovine Embryo Production with Follicular Oocytes Obtained via Ultrasound-guided Ovum Pick-up (OPU) and Slaughterhouse-derived(SHD) Ovary Aspiration in Korean Native Cows (한우에서 초음파 유래와 도축장 유래 난포란을 이용한 체외 수정란 생산에 관한 연구)

  • 손우진;강태영;조성근;심보웅;최민철;최상용;박충생;이효종
    • Journal of Embryo Transfer
    • /
    • v.13 no.2
    • /
    • pp.107-115
    • /
    • 1998
  • The present study was carried out for the comparative study on the collection of bovine follicular oocytes by ultrasound-guided ovum pick-up(OPU) and slaughterhouse-derived (SHD) ovary aspiration and in vitro production of bovine embryos with the follicular oncytes in Korean native cows. Bovine follicular nocytes were observed with a 6.5 MHz convex-array ultrasound transducer designed for intravaginal use and the oocytes were collected with the aspiration equipment attached to the ultrasonograph. Bovine ovaries were collected and transported in phosphate buffered saline from the local slaughterhouse, the follicular oocytes were collected by the aspiration method. The collected follicular oocytes in good quality were matured, fertilized and cultured in the media. The total number of the visible follicles and the recovery rate of follicular oocytes were increased in ultrasonography following follicle stimulating hormone(FSH) treatment in Korean native cows. The mean recovery rate of oocytes was 66.2, 52.8 and 41.7% in the FSH-OPU, non-treatment-OPU and SHD ovaries, respectively. The mean number of recorved oocytes per cow were not significantly(P<0.05) different between the FSH-OPU(14.0$\pm$11.54) and SHD(17.1i6.21) groups, but the numbers in both groups were significantly(P<0.05) higher than the number in the non-treatment-OPU(3.7$\pm$1.57) group. The mean number of usable nocytes in Grade T /11 per ovary was 6.3, 4.8 and 1.3 in the cows of the SHD, FSH-OPU and non-treatment-OPU groups, respectively. The in vitro developmental rate to the blastocyst was not significantly different between the oocytes obtained via OPU(37.1%) and SHD(29.3%). Therefore, the ultrasound-guided OPU technique can be applied to the production of excellent embryos from the high-quality cows, and for the large scale production of in vitro bovine oocytes and embryos, the SHD ovary aspiration method is valuable.

  • PDF

Transyaginal Ultrasound-guided Oocytes Collection in Superovulated Korean Native Cows (과배란처리 한우에서 초음파 유도에 의한 난자채란에 대한 연구)

  • 이효종;강태영;조성근;박준규;손우진;최민철;최상용
    • Journal of Embryo Transfer
    • /
    • v.12 no.2
    • /
    • pp.195-202
    • /
    • 1997
  • The present study was carried out to evaluate the effect of superovulation treatments on ovarian responses, oocyte recovery rates and grades of collected oocytes using an ultrasound-guided transvaginal approach in Korean native cows. Superovulation in cows was induced with two different regimenes: 1) FSH-decreasing dose(n=8): the cows were received twice per day for three days of the total dose of 400 mg of FSH-p, 2) FSH-single dose(n=9): the cows were administrated a single dose of 400 mg of FSH-p in 25% PVP. The Observation of visible follicles and collection of oocytes were performed 12 hours following the last FSH in FSH-decreasing dose group and 48 hours after the FSH-single dose injection. All visible follicles larger than 6 mm were punctured and aspirated with a 6.5 MHz convex-array ultrasound transducer designed for intravaginal use. The mean number of visible follicles(> 6 mm) was significantly(P<0.05) higher in the FSH-decreasing dose treatment (22.811.9) and FSH-single dose treatment (20.612.0) groups than the non-treatment group(7.0$\pm$8). The mean recovery rate of oocytes was not significantly(P<0.05) different between the treatment and control groups, but the mean number of collected oocytes was significantly(P<0.05) higher in the FSH-decreasing dose treatment( 12.611.5) and FSH-single dose treatment (11.813.6) groups than the non-treatment group(3.7$\pm$0.5). In conclusion, the FSH-single dose treatment at superovulation in cows for ultrasound-guided aspiration might increase the number of aspiratable follicles and the recovery rate of follicular oocytes as the FSH-decreasing dose treatment.

  • PDF

Optimization of Ultrasonic Soil Washing Processes Using Aluminum Foil Erosion Tests (알루미늄 호일 부식 실험을 이용한 초음파 토양 세척 공정 개발의 기초 연구)

  • Kim, Seulgi;Son, Younggyu
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.37 no.2
    • /
    • pp.92-98
    • /
    • 2015
  • The physical effect induced by acoustic cavitation was investigated to accumulate basic data for the design of ultrasonic soil washing processes using aluminum foil erosion tests. A square aluminum foil was placed on the glass beads in the pyrex vessel submerged in the sonoreactor equipped with a 36 kHz ultrasound transducer module at the bottom. Cavitational erosion of foils was quantitatively analyzed for various glass bead diameter conditions (1, 2, and 4 mm), glass bead height conditions (5, 10, 15, and 20 mm), and water height conditions (5, 10, 15, and 20 mm). It was found that aluminum foil erosion significantly increased as the glass bead diameter increased and water height over the glass bead increased due to less attenuation of ultrasound and the optimization of sound field for cavitation. Moreover mechanical mixing was suggested to move constantly particles to the bottom area where the acoustic cavitation occurs most violently. It was because aluminium foil erosion by ultrasound transmitted through glass beads was relatively too weak.

Enhanced Transdermal Permeation Effects of Lidocaine Gel by Low Frequency Ultrasound (저주파수 초음파를 이용한 Lidocaine Gel의 피부투과 촉진 효과)

  • Jung, Dae-In;Lee, Jung-Woo;Ahn, Hyo-Cho;Yang, Jae-Heon;Kim, Tae-Youl;Cho, Seong-Wan;Kim, Young-Il
    • Korean Chemical Engineering Research
    • /
    • v.46 no.2
    • /
    • pp.217-221
    • /
    • 2008
  • To investigate the enhancing effects in transdermal permeation of drug using newly designed ultrasound apparatus of 500 kHz, the transdermal permeation studies through the hairless mouse skin were conducted with lidocaine. The ultrasound apparatus of 500 kHz frequency and transducer were newly developed. The drug permeation studies were performed according to the ultrasound frequencies such as 1 MHz and 500 kHz at $1W/cm^2$ in intensity in continuous mode or pulsed mode, respectively. The results on transdermal permeation of lidocaine according to ultrasound intensity showed that the drug permeation increased as the intensity was higher.

Suppression of side lobe using distance weight in spectrum of channel signal in medical ultrasound imaging system (의료용 초음파 영상 시스템에서 채널신호의 스펙트럼에서 거리 가중치를 이용한 부엽의 억제)

  • Yu Rim Lee;Mok Kun Jeong
    • The Journal of the Acoustical Society of Korea
    • /
    • v.42 no.3
    • /
    • pp.203-213
    • /
    • 2023
  • In medical ultrasound imaging systems, Side lobes may appear if signals outside the imaging point are not completely removed during receive focusing. If the time signal of the side lobe overlaps with the time signal (main lobe) from the image point, it is difficult to completely remove it using filter processing in the time domain. However, In the receive focusing process, when time-channel signals are Fourier-transformed, the main lobe and side lobe signals are spatially separated in the spectral domain. Therefore, the side lobes can be suppressed by multiplying the image with magnitude weights, which are determined by the magnitudes of the main and side lobes calculated in the spectral domain. In addition, when the main lobe and the side lobe spectrum are adjacent, the distance weight was applied based on the distance between them. In a 5 MHz ultrasound imaging system using a 64-channel linear transducer, point reflector and speckle images with cysts of various brightness were synthesized and weights were applied to the ultrasound image. Using computer simulations, we confirmed that the side lobes were greatly reduced without affecting the spatial resolution in the point reflector image, and the contrast was significantly improved in the cyst image with computer simulations.

Effect of a Bonding Layer between Electrodes on the Performance of a λ/4-Mode PVDF Ultrasound Transducer (λ/4 모드 PVDF 초음파 트랜스듀서에 있어서 전극 사이의 접합층이 성능에 미치는 영향)

  • Cao, Yonggang;Ha, Kanglyeol;Kim, Moojoon;Kim, Jungsoon
    • The Journal of the Acoustical Society of Korea
    • /
    • v.33 no.2
    • /
    • pp.102-110
    • /
    • 2014
  • The effect of a bonding layer on the performance of a quarter-wave (${\lambda}/4$) mode PVDF ultrasound transducer having not only a piezoelectric layer but also a non-piezoelectric layer between two electrodes was analyzed. The equivalent circuit of a transmission line model by Kikuchi et al.[Sound of IEICE, 55-A, 331-338 (1981)] was introduced for the analysis. The validity of the model was confirmed by comparison with a KLM model for three postulated adhesion cases of a $80{\mu}m$ thick piezoelectric PVDF film to a copper (Cu) backer. The pulse-echo responses of five PVDF transducers, each fabricated with a different thickness ($5{\mu}m{\sim}20{\mu}m$) of the bonding layer, were measured and the results were compared with those by simulation. The two results were in good agreement with each other and it was noted that the effect of the bonding layer on the performance of the transducer could be analyzed by the Kikuchi model. In detail, the $20{\mu}m$ bonding layer decreased the center frequency and the bandwidth by about 19.7 % and 25.0 %, respectively, and increased the insertion loss by 57.2 %.

Fabrication and Evaluation of High Frequency Ultrasound Receive Transducers for Intravascular Photoacoustic Imaging (혈관내 광음향 영상을 위한 고주파수 초음파 수신 변환기 제작 및 평가)

  • Lee, Jun-Su;Chang, Jin Ho
    • The Journal of the Acoustical Society of Korea
    • /
    • v.33 no.5
    • /
    • pp.300-308
    • /
    • 2014
  • Photoacoustic imaging is a useful tool for the diagnosis of atherosclerosis because it is capable of providing anatomical and pathological information at the same time. A photoacoustic signal detector is a pivotal element to achieve high spatial resolution, so that it should have broadband spectrum with a high center frequency. Since a photoacoustic imaging probe is directly inserted into blood vessel to diagnose atherosclerosis, the total size of the photoacoustic signal detector should be less than 1 mm. The main purpose of this paper is to demonstrate that PVDF can be used as an active material for the photoacoustic signal detector with a high frequency and broadband characteristic. The photoacoustic signal detector developed in this study was a single element ultrasound transducer with an aperture of $0.5{\times}0.5mm$ and the total size of 1 mm. In the design stage, the natural focal depth was adjusted for an effective focal area to cover the region of interest, i.e., 1~5 mm in depth. This was because geometrical focusing could not be used due to the small aperture. Through a pulse-echo test, it was ascertained that the developed photoacoustic signal detector has the -6 dB bandwidth ranging between 40.1 and 112.8 MHz and the center frequency of 76.83 MHz.

Measurement of Prostate Phantom Volume Using Three-Dimensional Medical Imaging Modalities (3차원 의료영상진단기기를 이용한 가상 전립선 용적 측정)

  • Seoung, Youl-Hun;Joo, Yong-Hyun;Choe, Bo-Young
    • Journal of Biomedical Engineering Research
    • /
    • v.31 no.4
    • /
    • pp.285-291
    • /
    • 2010
  • Recently, advance on various modalities of diagnosing, prostate volume estimation became possible not only by the existing two-dimension medical images data but also by the three-dimensional medical images data. In this study, magnetic resonance image (MRI), computer tomography (CT) and ultrasound (US) were employed to evaluate prostate phantom volume measurements for estimation, comparison and analysis. For the prostate phantoms aimed at estimating the volume, total of 17 models were developed by using devils-tongue jelly and changing each of the 5ml of capacity from 20ml to 100ml. For the volume estimation through 2D US, the calculation of the diameter with C9-5Mhz transducer was conducted by ellipsoid formula. For the volume estimation through 3D US, the Qlab software (Philips Medical) was used to calculate the volume data estimated by 3D9-3Mhz transducer. Moreover, the images by 16 channels CT and 1.5 Tesla MRI were added by the method of continuous cross-section addition and each of imaginary prostate model's volume was yielded. In the statistical analysis for comparing the availability of volume estimation, the correlation coefficient (r) was more than 0.9 for all indicating that there were highly correlated, and there were not statistically significant difference between each of the correlation coefficient (p=0.001). Therefore, the estimation of prostate phantom volume using three-dimensional modalities of diagnosing was quite closed to the actual estimation.