• Title/Summary/Keyword: Ultrasound scan

Search Result 133, Processing Time 0.026 seconds

Using Field Programmable Gate Array Hardware for the Performance Improvement of Ultrasonic Wave Propagation Imaging System

  • Shan, Jaffry Syed;Abbas, Syed Haider;Kang, Donghoon;Lee, Jungryul
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.35 no.6
    • /
    • pp.389-397
    • /
    • 2015
  • Recently, wave propagation imaging based on laser scanning-generated elastic waves has been intensively used for nondestructive inspection. However, the proficiency of the conventional software based system reduces when the scan area is large since the processing time increases significantly due to unavoidable processor multitasking, where computing resources are shared with multiple processes. Hence, the field programmable gate array (FPGA) was introduced for a wave propagation imaging method in order to obtain extreme processing time reduction. An FPGA board was used for the design, implementing post-processing ultrasonic wave propagation imaging (UWPI). The results were compared with the conventional system and considerable improvement was observed, with at least 78% (scanning of $100{\times}100mm^2$ with 0.5 mm interval) to 87.5% (scanning of $200{\times}200mm^2$ with 0.5 mm interval) less processing time, strengthening the claim for the research. This new concept to implement FPGA technology into the UPI system will act as a break-through technology for full-scale automatic inspection.

An Exploration of the maternal & paternal-fetal attachment (임신한 부부의 태아 애착에 관한 연구)

  • Ahn, Suk-Heui
    • 모자간호학회지
    • /
    • v.3 no.1
    • /
    • pp.49-63
    • /
    • 1993
  • The purpose of the study was to identify the maternal & paternal-fetal attachment. The subjects were 130 pregnant women and 85 their husbands. Data were collected in OB & GY clinic by modified Cranley's Maternal-Fetal Attachment Scale. The results were as follows : 1. The mean scores of maternal-fetal attachment (MFA) was 75.57(range: 48-92). The most frequently practiced attachment item was "I can hardly walt to hold the baby(mean 4.32)". The mean scores of paternal-fetal attachment (PFA) was 65.48(range : 48-92). The most frequently practiced attachment item was "I can hardly wait to hold the baby(mean 4.25)". 2. There were significant difference in the degree of MFA, namely, gestational period(p=.020), whether the women had been special things(p=.000) and had experiened on ultrasound scan(p=.001). In the PFA, gestational period(p=.013) gravida(p=.016), duration of marriage(p=.001), family type(p=.036) and whether the women had a health problem(p=.035) were significant difference in degree of attachment. In conclusions, it can be said that parent demonstrated mid-level of attachment to their fetus during pregnancy. Several other factors seemed to be related, indicating a need for further study on maternal & paternal-fetal attachment. It will designed and managed parental class to promoting maternal & paternal-fetal attachment.

  • PDF

Implantation of Small Artery Vessel from Blends PCL/PU with and without Anti-thrombus

  • Hiep, Nguyen Thi;Lee, Seong-Jin;Min, Young-Ki;Yang, Hun-Mo;Song, Ho-Yeon;Lee, Byong-Taek
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2010.05a
    • /
    • pp.45.1-45.1
    • /
    • 2010
  • In this experiment, artificial blood vessel was fabricated from electro-spun PU/PCL. To assist with endothelial growth, PU/PCL surface was coated with the RGD peptide. To prevent a clot of blood, anti-thrombus agent was loaded to the fibrous mat and values were reflected through FT-IR data. In vitro study, SEM and MTT data showed that the component was of excellent biocompatibility and cell proliferation. In in vivo study, the artificial blood vessel was implanted in a dog's artery. The results of the CT scan, ultrasound and H&E staining showed that artificial blood vessel was excellent for artery replacement applications.

  • PDF

Partial molar pregnancy and coexisting fetus with Turner syndrome: Case report and literature review

  • Park, Ji Eun;Park, Ji Kwon;Cho, In Ae;Baek, Jong Chul
    • Journal of Genetic Medicine
    • /
    • v.15 no.1
    • /
    • pp.43-47
    • /
    • 2018
  • Partial hydatidiform mole and coexisting fetus is a rare entity with antecedent high risk of maternal and fetal complications, and risk of persistent trophoblastic disease in later life. Here, we report a case of twin pregnancy with live fetus identified as 45,X and normal placenta and another partial mole. Ultrasound scan at 10 weeks showed a hydrops fetus with a focal area of multicystic placenta. The patient underwent chorionic villus sampling and amniocentesis for chromosomal analysis, and the result was 45,X. Based on these finding, the patient then underwent induced abortion. Pathological examination (immunohistochemical staining) of the placenta confirmed the partial mole. This report suggests that careful prenatal ultrasonography and appropriate karyotyping in a molar pregnancy and coexisting fetus enable early diagnosis and may be beneficial for prognosis.

Gastrointestinal Stromal Tumor of the Stomach Presenting as Multilobular with Diffuse Calcifications

  • Kim, Sae Hee;Lee, Moon-Soo;Cho, Byung Sun;Park, Joo-Seung;Han, Hyun-Young;Kang, Dong-Wook
    • Journal of Gastric Cancer
    • /
    • v.16 no.1
    • /
    • pp.58-62
    • /
    • 2016
  • Gastrointestinal stromal tumors (GISTs) are the most common primary mesenchymal neoplasms of the gastrointestinal tract and usually appear as a well-circumscribed mass. However, it may be difficult to confirm the extent of the disease for some GISTs. A 70-year-old asymptomatic female presented for a regular physical exam. An esophagogastroduodenoscopy showed a 2.0 cm protruding mass on the gastric fundus. Endoscopic ultrasound revealed an ill-defined heterogenous hypoechoic lesion ($3.0{\times}1.5cm$). A computed tomography (CT) scan demonstrated a 4.5 cm multifocal calcified mass at the gastric body as well as at the gastric fundus. Laparoscopic gastric wedge resection was performed according to the extent of multifocal calcifications that are shown on the CT. Intraoperative specimen mammography and intraoperative biopsy might be helpful to obtain a tumor-free margin. Final pathologic diagnosis was an intermediate risk GIST in multilobular form. In patients with diffuse multifocal calcifications in the stomach, the possibility of GIST should be considered.

Artificial Intelligence-based Echocardiogram Video Classification by Aggregating Dynamic Information

  • Ye, Zi;Kumar, Yogan J.;Sing, Goh O.;Song, Fengyan;Ni, Xianda;Wang, Jin
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.15 no.2
    • /
    • pp.500-521
    • /
    • 2021
  • Echocardiography, an ultrasound scan of the heart, is regarded as the primary physiological test for heart disease diagnoses. How an echocardiogram is interpreted also relies intensively on the determination of the view. Some of such views are identified as standard views because of the presentation and ease of the evaluations of the major cardiac structures of them. However, finding valid cardiac views has traditionally been time-consuming, and a laborious process because medical imaging is interpreted manually by the specialist. Therefore, this study aims to speed up the diagnosis process and reduce diagnostic error by providing an automated identification of standard cardiac views based on deep learning technology. More importantly, based on a brand-new echocardiogram dataset of the Asian race, our research considers and assesses some new neural network architectures driven by action recognition in video. Finally, the research concludes and verifies that these methods aggregating dynamic information will receive a stronger classification effect.

FPGA-Based Low-Power and Low-Cost Portable Beamformer Design (FPGA 기반 저전력 및 저비용 휴대용 빔포머 설계)

  • Jeong, GabJoong;Park, CheolYoung
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.24 no.1
    • /
    • pp.31-38
    • /
    • 2019
  • In this paper, we develop a beamforming front end platform with pipeline circuit configuration method that can apply various clinical diagnostic applications of ultrasound image technology. Hardware design targets compression applications as well as scalable applications where power, integration levels and replication possibilities are important. Firmware design was implemented to achieve optimal FPGA parallel processing level by constructing new IP and system-oriented design environment to accelerate design productivity with maximum productivity improvement using Vivado HLS tool, which is a next generation high level synthesis tool. Former supports the high-speed management function of scan data that can create an image area arbitrarily and can be appropriately corrected and supplemented when reconfiguring or changing system specifications in the future.

A Study of Improve on a Backscatter Data of Multibeam Echo-sounder Using Digital Image Processing (디지털 영상처리기법를 이용한 멀티빔 음향측심기의 음압자료 향상 연구)

  • Hye-Won Choi;Doo-Pyo Kim
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.26 no.1
    • /
    • pp.133-141
    • /
    • 2023
  • Accurate measurement of seafloor topography plays a crucial role in developing marine industries such as maritime safety, resource exploration, environmental protection, and coastal management. The seafloor topography is constructed using side scan sonar (SSS) and single beam echosounder (SBES) or multibeam echosounder (MBES), which transmit and receive ultrasound waves through a device attached to a marine survey vessel. However, the use of a sonar system is affected by noise pollution areas, and the single beam has a limited scope of application. At the same time, the multibeam is mainly applicable for depth observation. For these reasons, it is difficult to determine the boundaries and areas of seafloor topography. Therefore, this study proposes a method to improve the backscatter data of multibeam echosounder, which has a relationship with the seafloor quality, by using digital image processing to classify the shape of the underwater surface.

Ulnar artery access for intracranial mechanical thrombectomy procedure: A salvage option after failed trans-femoral and trans-radial access

  • Muhammad U Manzoor;Abdullah A Alrashed;Ibrahim A Almulhim;Sultan Alqahtani;Fahmi Al Senani
    • Journal of Cerebrovascular and Endovascular Neurosurgery
    • /
    • v.25 no.4
    • /
    • pp.429-433
    • /
    • 2023
  • 84 years old gentle man with past medical history of hypertension and diabetes presented with sudden onset right sided weakness and aphasia for two hours. Initial neurological assessment revealed National Institute of Health Stroke Scale (NIHSS) 17. Computed tomography (CT) scan demonstrated minimal early ischemic changes along left insular cortex with occlusion of left middle cerebral artery (MCA). Based on clinical and imaging findings, decision was made to perform mechanical thrombectomy procedure. Initially, right common femoral artery approach was utilized. However, due to unfavorable type-III bovine arch, left internal carotid artery could not be engaged via this approach. Subsequently, access was switched to right radial artery. Angiogram revealed small caliber radial artery, with larger caliber ulnar artery. Attempt was made to advance the guide catheter through the radial artery, however significant vasospasm was encountered. Subsequently, ulnar artery was accessed and successful thrombolysis in cerebral infarction (TICI) III left MCA reperfusion was achieved with a single pass of mechanical thrombectomy via this approach. Post procedure neurological examination demonstrated significant clinical improvement. Doppler ultrasound 48 hours after the procedure demonstrated patent flow in radial and ulnar arteries with no evidence of dissection.

Correlation of Refractive Error, Axial Length, Chamber Depth, Lens Thickness and Corneal Thickness of Normal University Students (정상 대학생의 눈 굴절이상, 안축장, 전방깊이, 수정체두께 그리고 각막두께의 연관성)

  • Kim, Chang-Sik;Lee, Hak-Jun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.13 no.1
    • /
    • pp.89-94
    • /
    • 2008
  • Purpose: To make a comparative study of correlation between biometry data of size in eyeball and refractive error. Methods: The subjects were 68 normal university students (male 36, female 32) and the average age was 22.85${\pm}$3.12. We measured the students' eyesight by A-scan ultrasound and refractor. The results were examined it's statistical significance by SPSS 12.0 version. Results: The mean of axial length was 24.31${\pm}$1.24 mm, chamber depth was 3.48${\pm}$0.28 mm, lens thickness was 3.56${\pm}$0.26 mm and corneal thickness was 0.55${\pm}$0.03 mm. Male's Axial length and chamber depth were larger than female's. As reflective error decreases the thickness of lens become thicker. The measurement data between right eye and left eye didn't had difference and there was no correlation with result of T-test. There were statistically significant correlation with length and chamber depth, axial length and corneal thickness, chamber depth and corneal thickness, and refractive error and lens thickness (p<0.01). Refractive error and axial length were minus linear regression (r=-0.56). Conclusions: Eye's refractive error was changed by axial length, chamber depth and lens thickness but it wasn't related with sex and whether it is a right eye or a left eye.

  • PDF