• 제목/요약/키워드: Ultrasound head

검색결과 96건 처리시간 0.026초

Changes of abdominal muscle thickness during stable and unstable surface bridging exercise in young people

  • Kim, Tae Hoon;Hahn, Joohee;Jeong, Ju-Ri;Lee, Changjoo;Kim, You Jin;Choi, Sung Min;Jeon, Da Young;Lee, Jin Hwa;Lim, In-Hyuk;Lee, Wan-Hee
    • Physical Therapy Rehabilitation Science
    • /
    • 제5권4호
    • /
    • pp.210-214
    • /
    • 2016
  • Objective: The aim of this study was to measure the muscle architectural parameters of abdominal muscles in healthy individuals by rehabilitative ultrasound imaging (RUSI) and to investigate their changes after bridging exercise in various environments. Design: Cross-sectional study. Methods: The study included 40 healthy participants (19 men, 21 women). Subjects were randomly allocated to a stable surface group (SG, n=20) or an unstable surface group (UG, n=20). The participants assumed three positions in rest, bridging exercise with knee flexion $60^{\circ}$, and bridging exercise with knee flexion $90^{\circ}$ for the measurement of abdominal muscle thickness by RUSI. For the resting position, the participants held the head neutral in a hook-lying position and the dominant side was measured. For contraction, the participants performed the bridging exercise with the knee joint in $60^{\circ}$ and $90^{\circ}$ of flexion for 10 seconds each. Results: For transversus abdominis, external oblique muscle thickness, within the stable surface group and the unstable surface group, no significant contraction difference was observed in both the $60^{\circ}$ and $90^{\circ}$ bridge exercise conditions. Contraction difference of internal oblique muscle was significantly larger at $90^{\circ}$ than at $60^{\circ}$ within the SG (p<0.05). But within the UG, no significant contraction difference was shown. There was no significant contraction difference between the surface group and the unstable SG at $60^{\circ}$ condition and at $90^{\circ}$ condition in all measured muscles. Conclusions: The contraction difference is different for each muscle during bridge exercise with knee flexion $60^{\circ}$ and bridging exercise with knee flexion $90^{\circ}$. Muscle contraction difference is generally large when exercised on an unstable surface than a stable surface, but these are not statistically significant when bridging exercise is performed using dynamic air cushion for unstable surface.

상완 이두건의 병소에 대한 초음파 검사의 유용성 (Efficacy of Ultrasonogram for the Diagnosis of Biceps Tendon Pathology)

  • 서중배;이지영;방승철
    • Clinics in Shoulder and Elbow
    • /
    • 제11권2호
    • /
    • pp.90-95
    • /
    • 2008
  • 목적: 회전근 개 질환 환자에서 상완 이두건의 병소에 대한 수술 전 초음파 검사의 정확성을 알아보기 위하여 본 연구를 시행하였다. 대상 및 방법: 2006년 1월부터 2007년 3월까지 회전근 개 질환으로 수술적 치료를 받은 환자 중 수술 전 초음파 검사를 시행 한 67명의 환자를 대상으로 후향적 조사를 하였다. 환자들의 연령은 평균 58세였으며, 남자 41예, 여자 26예였다. 상완 이두건의 관절경 및 초음파 소견은 '정상', '탈구', '아탈구', '건증', '부분 또는 완전 파열'등으로 기술하였으며, 관절경과 초음파 소견 간의 일치 여부를 조사하였다. 결과: 초음파 검사 67예 중 37예가 '정상'이었으며, 30예가 '비정상'이었다. '정상' 37예 중 5예는 관절경 검사상 '부분 파열'이 있었으며, '비정상' 30예 중 8예는 관절경 검사상 '정상'이었다. 초음파 검사상 3예의 '탈구' 및 4예의 '완전 파열'은 관절경 검사 결과와 일치하였다. 초음파 검사에서 '건증'이 기술된 20예는 관절경 검사에서 '부분 파열' 15예, '정상' 5예로 관찰되었다. 결론: 상완 이두건의 병소에 대한 초음파 검사는 상완 이두건의 탈구 또는 완전 파열 시에는 진단이 일치하였으나, 부분 파열에 대해서는 정확한 진단이 어려웠다.

Incidental Abnormal FDG Uptake in the Prostate on 18-fluoro-2-Deoxyglucose Positron Emission Tomography-Computed Tomography Scans

  • Kang, Pil Moon;Seo, Won Ik;Lee, Sun Seong;Bae, Sang Kyun;Kwak, Ho Sup;Min, Kweonsik;Kim, Wansuk;Kang, Dong Il
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제15권20호
    • /
    • pp.8699-8703
    • /
    • 2014
  • 18-fluoro-2-deoxyglucose positron emission tomography-computed tomography ($^{18}F$-FDG PET/CT) scans are commonly used for the staging and restaging of various malignancies, such as head and neck, breast, colorectal and gynecological cancers. However, the value of FDG PET/CT for detecting prostate cancer is unknown. The aim of this study was to evaluate the clinical value of incidental prostate $^{18}F$-FDG uptake on PET/CT scans. We reviewed $^{18}F$-FDG PET/CT scan reports from September 2009 to September 2013, and selected cases that reported focal/diffuse FDG uptake in the prostate. We analyzed the correlation between $^{18}F$-FDG PET/CT scan findings and data collected during evaluations such as serum prostate-specific antigen (PSA) levels, digital rectal examination (DRE), transrectal ultrasound (TRUS), and/or biopsy to confirm prostate cancer. Of a total of 18,393 cases, 106 (0.6%) exhibited abnormal hypermetabolism in the prostate. Additional evaluations were performed in 66 patients. Serum PSA levels were not significantly correlated with maximum standardized uptake values (SUVmax) in all patients (rho 0.483, p=0.132). Prostate biopsies were performed in 15 patients, and prostate cancer was confirmed in 11. The median serum PSA level was 4.8 (0.55-7.06) ng/mL and 127.4 (1.06-495) ng/mL in the benign and prostate cancer groups, respectively. The median SUVmax was higher in the prostate cancer group (mean 10.1, range 3.8-24.5) than in the benign group (mean 4.3, range 3.1-8.8), but the difference was not statistically significant (p=0.078). There was no significant correlation between SUVmax and serum PSA, prostatic volume, or Gleason score. $^{18}F$-FDG PET/CT scans did not reliably differentiate malignant or benign from abnormal uptake lesions in the prostate, and routine prostate biopsy was not usually recommended in patients with abnormal FDG uptake. Nevertheless, patients with incidental prostate uptake on $^{18}F$-FDG PET/CT scans should not be ignored and should be undergo further clinical evaluations, such as PSA and DRE.

판형 웨이브가이드 초음파 센서를 이용한 소듐냉각고속로 원격주사 검사기법 개발 (Development of a Ranging Inspection Technique in a Sodium-cooled Fast Reactor Using a Plate-type Ultrasonic Waveguide Sensor)

  • 김회웅;김상활;한재원;주영상;박창규;김종범
    • 한국소음진동공학회논문집
    • /
    • 제25권1호
    • /
    • pp.48-57
    • /
    • 2015
  • 제 4세대 원자로로 개발되고 있는 소듐냉각고속로는 냉각재로 사용되는 소듐의 물과 공기에 의한 반응을 방지하기 위하여 원자로 헤드의 개방 없이 회전 구동만을 이용하여 핵연료 교환을 수행한다. 따라서 핵연료 교환을 위해서는 노심과 상부내부구조물 사이의 공간에 원자로 헤드의 회전 구동을 방해하는 장애물의 존재 여부를 확인하는 검사가 반드시 선행되어야 하는데, 소듐의 불투명성으로 인해 통상적인 광학 장비를 사용한 검사방법으로는 장애물의 확인이 어렵고, 초음파를 이용한 검사방법이 적용되어야 한다. 이 연구에서는 불투명한 소듐 중에서 노심과 상부내부구조물 사이의 장애물 존재 여부를 확인하기 위하여 판형 웨이브가이드 초음파 센서를 적용한 원격주사 검사기법을 개발하였다. 웨이브가이드 센서는 원자로헤드 상부의 저온 구간에 초음파 트랜스듀서를 설치하고 길이가 긴 웨이브가이드를 사용하여 노심 상부의 고온 고방사능 소듐 내부로 초음파를 전파시키기 때문에, 고온 고방사능에 의한 손상 없이 장시간 적용이 가능한 장점을 가지고 있다. 먼저, 수평 방향으로 초음파를 방사시킬 수 있는 10 m 길이의 수평 빔 웨이브가이드 센서를 설계 제작하였고, 제작된 센서의 특성 분석을 위한 빔 프로파일 측정 및 기초 실험을 수행하여 방사되는 초음파의 빔 폭과 전파 거리를 평가하였다. 또한, 실제 장애물로 작용할 수 있는 부품들의 형상인 원형 목표물에 대한 원격탐지 성능시험을 수행하여 개발된 원격주사 기술의 유용성을 평가하였다.

성인 요로 감염 환자에서 $^{99m}Tc-DMSA$ 삼중검출기 SPECT 영상의 유용성 (Triple Detector SPECT Imaging with $^{99m}Tc-DMSA$ in Adult Patients with Urinary Tract Infection)

  • 류진숙;배원규;문대혁;이명혜;김순배;박수길;박정식;홍창기;조경식
    • 대한핵의학회지
    • /
    • 제26권2호
    • /
    • pp.290-298
    • /
    • 1992
  • Although early diagnosis of urinary tract infection is important, the radiologic evaluation is still controversial because of the low sensitivity and the lack of cost-effectiveness. This study was carried out to evaluate the clinical utility of high resolution triple head $^{99m}Tc-DMSA$ SPECT imaging in urinary tract infection. We prospectively performed $^{99m}Tc-DMSA$ planar and SPECT imaging, ultrasound of kidney (US), intravenous pyelography (IVP) and voiding cystourethrography (VCU) in all 60 adult patients with UTI [26 with first episode of acute pyelonephritis (APN), 22 with recurrent APN, and 12 persistent asymptomatic pyuria] and 25 normal persons. To assess reversibility of the renal cortical defect (RCD), $^{99m}Tc-DMSA$ SPECT was repeated 1 to 8 months later in those patients with abnormal initial findings. Overall detection rate of $^{99m}Tc-DMSA$ SPECT imaging was 83% (50/60), but planar, US, IVP and VCU showed abnormal findings in 68%, 28%, 32% and 13%, respectively. 25 out of 27 patients with normal or single RCD were all normal in other radioligic studies. Only two patients showed vesicoureteral reflux (VUR) on VCU (grade I) and mild hydronephrosis on IVP. But, high proportion of those with multiple RCD showed abnormal findings on US (17/33), IVP (18/33), and VCU (7/33): 67% in any of these 3 studies. Especially, 3 out 7 patients with VUR showed multiple RCD on $^{99m}Tc-DMSA$ SPECT without any abnormality on IVP or US. 25 normal persons showed normal findings in all studies except one false positive finding on $^{99m}Tc-DMSA$ SPECT imaging. Follow-up $^{99m}Tc-DMSA$ SPECT was done in 28 patients (13 with single RCD, 15 with multiple RCD). All 13 patients with single RCD showed improvement. Those with multiple RCD presented improvement in 4, no change in 10, and aggravation in 1 on follow-up studies. With these results, we conclude: 1) $^{99m}Tc-DMSA$ SPECT imaging is superior to planar imaging, US, IVP or VCU in detection of renal lesion in urinary tract infection. $^{99m}Tc-DMSA$ SPECT is useful as a initial diagnostic tool in adult patients with urinary tract infection. 2) The multiple RCD on $^{99m}Tc-DMSA$ SPECT represent the high probability of irreversible tissue change and need of extensive urological work-up.

  • PDF

생체 외 토끼 모델에서의 탈크에 의해 유발되는 흉막 반응의 편광 민감 광 결맞음 단층촬영 이미징 (Polarization-sensitive Optical Coherence Tomography Imaging of Pleural Reaction Caused by Talc in an ex vivo Rabbit Model)

  • 박정은;;옥철호;김성원;이해영;박은기;정민정;권다영;;안예찬
    • 한국광학회지
    • /
    • 제31권1호
    • /
    • pp.1-6
    • /
    • 2020
  • 흉벽은 호흡을 통해 환경 입자의 직접적인 영향을 받는 기관으로 늑골, 흉막층, 늑간근으로 구성되어 있다. 흉벽의 질병을 조기에 진단하고 치료하기 위해서는 흉벽의 세세한 부분을 시각화하는 것이 중요하지만, 흉부 전산화 단층촬영이나 초음파로는 흉막층의 구조를 볼 수 없다. 반면, 고해상도의 광 결맞음 단층촬영법(optical coherence tomography, OCT)은 미세한 재료 중 하나인 탈크에 의한 흉막층의 반응을 관찰하는 데 적합하다. 그러나 빛세기 기반의 광 결맞음 단층촬영법은 흉벽의 세부 구조를 구별할 수 있는 정보를 제공하기에는 부족하여 탈크에 의한 흉벽의 반응과 근육의 변화를 각각 구별할 수 없다. 편광 민감 광 결맞음 단층촬영법(polarization-sensitive OCT, PS-OCT)은 광학적 복굴절을 가진 근육 등의 특정 조직들이 후방산란된 빛의 편광 상태를 변화시킨다는 점을 이용한다. 또한 근필라멘트의 배열과 관련된 근육의 복굴절은 지연 변화를 측정함으로써 근육 상태를 나타낸다. 편광 민감 광 결맞음 단층촬영 영상은 두꺼운 흉벽, 흉벽과 근육 간의 분리, 병변 주위의 위상 지연 측정의 세 가지 주요 관점에서 해석된다. 본 논문에서는 탈크 흉막유착술(pleurodesis)을 시행한 토끼의 흉벽을 편광 민감 광 결맞음 단층촬영법으로 연구하였다. 편광 민감 광 결맞음 단층촬영 영상은 각 층과 근육을 시각화하였다. 그리고 이 시스템은 정상과 손상된 병변의 복굴절 차이를 보여주었다. 또한, 위상 지연 기울기 기반 분석을 통해 편광 민감 광 결맞음 단층촬영 영상 및 조직학적 결과를 뒷받침하였다.