• 제목/요약/키워드: Ultrasound device system

검색결과 43건 처리시간 0.024초

CTO 괴사를 위한 고강도 집속 초음파의 음향학적 특성 (Acoustic Characteristics of High Intensity Focused Ultrasound for Necrosis of CTO)

  • 박찬희;정상화
    • 한국생산제조학회지
    • /
    • 제24권5호
    • /
    • pp.481-488
    • /
    • 2015
  • It is difficult to see a therapeutic effect from cardiovascular disease treatment methods in the case of a hardened chronic total occlusion (CTO), owing to the calcification of the deposition materials. However, lesion cells, such as CTOs, can be selectively necrotized without affecting the normal tissue using high-intensity ultrasound focused on one point. In this study, a phantom CTO was necrotized by a high-intensity focused ultrasound (HIFU) energy system, and the acoustic characteristics in the focal region were analyzed. An experimental HIFU device was constructed to discover the appropriate conditions for the necrosis of a phantom CTO. The transfer characteristics of the ultrasound changed in the focal region by the density difference of the phantom CTO. These changes were acoustically analyzed to choose the available frequency band for each density. On-off temperature control in the focal region was applied to prevent rapid temperature rises, which would otherwise affect normal tissue.

초음파 무선 센서노드를 이용한 실시간 위치 추적 시스템 (Real-time Location Tracking System Using Ultrasonic Wireless Sensor Nodes)

  • 박종현;추영열
    • 제어로봇시스템학회논문지
    • /
    • 제13권7호
    • /
    • pp.711-717
    • /
    • 2007
  • Location information will become increasingly important for future Pervasive Computing applications. Location tracking system of a moving device can be classified into two types of architectures: an active mobile architecture and a passive mobile architecture. In the former, a mobile device actively transmits signals for estimating distances to listeners. In the latter, a mobile device listens signals from beacons passively. Although the passive architecture such as Cricket location system is inexpensive, easy to set up, and safe, it is less precise than the active one. In this paper, we present a passive location system using Cricket Mote sensors which use RF and ultrasonic signals to estimate distances. In order to improve accuracy of the passive system, the transmission speed of ultrasound was compensated according to air temperature at the moment. Upper and lower bounds of a distance estimation were set up through measuring minimum and maximum distances that ultrasonic signal can reach to. Distance estimations beyond the upper and the lower bounds were filtered off as errors in our scheme. With collecting distance estimation data at various locations and comparing each distance estimation with real distance respectively, we proposed an equation to compensate the deviation at each point. Equations for proposed algorithm were derived to calculate relative coordinates of a moving device. At indoor and outdoor tests, average location error and average location tracking period were 3.5 cm and 0.5 second, respectively, which outperformed Cricket location system of MIT.

Genetic Analysis of Ultrasound and Carcass Measurement Traits in a Regional Hanwoo Steer Population

  • Hwang, Jeong Mi;Cheong, Jae Kyoung;Kim, Sam Su;Jung, Bong Hwan;Koh, Myung Jae;Kim, Hyeong Cheol;Choy, Yun Ho
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제27권4호
    • /
    • pp.457-463
    • /
    • 2014
  • Ultrasound measurements of backfat thickness (UBF), longissimus muscle area (ULMA) and marbling score (UMS) and carcass measurements of carcass weight (CW), backfat thickness (BF), longissimus muscle area (LMA), and marbling score (MS) on 7,044 Hanwoo steers were analyzed to estimate genetic parameters. Data from Hanwoo steers that were raised, finished in Hoengseong-gun, Gangwon-do (province) and shipped to slaughter houses during the period from October 2010 to April 2013 were evaluated. Ultrasound measurements were taken at approximately three months before slaughter by an experienced operator using a B-mode real-time ultrasound device (HS-2000, FHK Co. Ltd., Tokyo, Japan) with a 3.5 MHz linear probe. Ultrasound scanning was on the left side between 13th rib and the first lumbar vertebrae. All slaughtering processes and carcass evaluations were performed in accordance with the guidelines of beef grading system of Korea. To estimate genetic parameters, multiple trait animal models were applied. Fixed effects included in the models were: the effects of farm, contemporary group effects (year-season at the time of ultrasound scanning in the models for UBF, ULMA, and UMS, and year-season at slaughter in the models for CW, BF, LMA, and MS), the effects of ultrasound technicians as class variables and the effects of the age in days at ultrasound scanning or at slaughtering as linear covariates, respectively for ultrasound and carcass measures. Heritability estimates obtained from our analyses were 0.37 for UBF, 0.13 for ULMA, 0.27 for UMS, 0.44 for CW, 0.33 for BF, 0.36 for LMA and 0.54 MS, respectively. Genetic correlations were strongly positive between corresponding traits of ultrasound and carcass measures. Genetic correlation coefficient between UBF and BF estimate was 0.938, between ULMA and LMA was 0.767 and between UMS and MS was 0.925. These results suggest that ultrasound measurement traits are genetically similar to carcass measurement traits.

필수성능 분석을 통한 효율적인 의료기기 기능안전 접근 방안 (Efficient Approaches of Functional Safety for Medical Equipment using Essential Performance Analysis)

  • 김기영;유기훈;박호준;장중순
    • 한국신뢰성학회지:신뢰성응용연구
    • /
    • 제15권1호
    • /
    • pp.27-32
    • /
    • 2015
  • Functional safety is part of the overall safety relating to the equipment under control (EUC) and the EUC control system that depends on the correct functioning of the electrical/electronic/programmable electronic (E/E/PE) safety-related systems. Since the complexity of the medical equipment is increased, manufactures have to obtain functional safety as well as basic safety. This study proposes a perspective for applying functional safety to medical equipment. The research is carried out with respect to overall safety life-cycle of functional safety and essential performance of the medical equipment. The relationship between functional safety and essential performance is identified centered on the safety function. The essential performance using E/E/PE systems is defined as a safety function of functional safety. This approach is applied to a ultrasound imaging system as a case study.

좌심실 보조기를 이용한 3상형 박동류 모의 (Emulation of Tri-Phasic Pulsatile Flow Using LVAD)

  • 이동혁;김종효
    • 대한의용생체공학회:의공학회지
    • /
    • 제19권3호
    • /
    • pp.313-320
    • /
    • 1998
  • 3상형 박동류는 인체 순환계 혈류의 일반적인 형태이다. 심혈관계의 여러 가지 상황을 모의하려면 이러한 3상형 박동류를 만들어 내는 것이 필수적이다. 본 연구에서는 3상형 박동류를 모의하기 위해서 전기유압식 좌심실보조기를 유리 팬텀과 고무 튜브와 같이 사용하였으며 혈류 모의 시스템의 제어변수를 선정하고 각 변수들의 변화에 대한 영향을 도플러 초음파를 이용하여 관찰하였다. 본 실험의 결과 협착 후위부 탄성과 지연시간이 3상형 혈류를 생성하는 중요한 요인이었다. 본 실험의 결과들은 다양한 혈류 운동을 모의할 수 있게 해 줌으로써 심혈관계의 여러현상을 설명하는 유용한 도구가 될 수 있을 것으로 기대된다.

  • PDF

임베디드 하드웨어 시스템 기반의 초음파 폐활량계 구현 및 감도 향상 연구 (An Implementation of the embedded hardware system based Ultrasonic Spirometer and Improvement of Its Sensitivity)

  • 이철원;김영길
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2005년도 추계종합학술대회
    • /
    • pp.417-420
    • /
    • 2005
  • 폐활량계(Spirometer)는 호흡하는 가스의 용적 유량의 순간적인 속도를 측정하는 의료기구로 폐의 기능시험과 환자 모니터링에 사용되며 용적 유량 신호를 합친 폐의 절대적인 용적변화를 측정한다. 본 논문에서는 환자를 대상으로 약한 호흡에서도 폐활량 측정이 가능 하도록, 관성의 오차 및 압력의 오차에 영향을 거의 받지 않는 초음파 센서를 이용하여 송수신시 초음파 신호를 향상시켰으며, 임베디스 하드웨어 시스템을 사용하여 약한 호흡에도 정확하고 빠른 검출이 가능한 시스템을 구현하였다.

  • PDF

N-365 다목적팬텀에서 초음파진단장치의 음속변화 효과 (The Effect of Acoustic Velocity of Ultrasonographic Equipment Using an N-365 Multipurpose Phantom)

  • 김연민;심재구;김상현
    • 한국방사선학회논문지
    • /
    • 제11권4호
    • /
    • pp.221-225
    • /
    • 2017
  • 초음파영상 진단장치의 성능을 평가할 때, 초음파장비에서 제공하는 음속변화 파라메타를 변화시킴에 따른 공간분해능의 변화를 알아보고자 하였다. 익산 소재 A기관에서 사용중인 초음파 진단장치에서 3.0 ~ 5.0 MHz 볼록형 탐촉자를 이용하여 초음파팬텀영상를 얻었다. N-365 다목적 초음파팬텀으로 종거리 측정정확도, 종 횡 해상도를 측정하였다. 같은 방법으로 초음파장치의 음속을1580 m/sec부터 1400 m/sec 까지 6단계로 변화시켜 측정 값의 차이가 있는지 image J 프로그램을 이용하여 반치폭을 측정하였다. 측정 결과, 횡측해상도는 속도변화에 따라 1.91 mm ~ 5.3 mm까지 측정되었으며, 음속 1420 m/sec 일 때 반치폭 1.91 mm로 가장 작게 측정되었다. 종측해상도는 1.03 mm ~ 1.14 mm까지 측정되었으며, 음속 1400 m/sec 일 때 반치폭 1.03 mm 로 가장 작게 측정되었다. 초음파장치의 음속이 느려질수록 종측정 길이가 짧아지는 상관관계를 보였다.

비집속 회분저주파를 이용한 Dunaliella salina 세포 파쇄 (Cell Disruption of Dunaliella salina using Batch Low Frequency Non-Focused Ultrasound)

  • 최준혁;김광호;박종락;정상화
    • 한국기계가공학회지
    • /
    • 제20권10호
    • /
    • pp.63-71
    • /
    • 2021
  • Using fossil fuels in existing industrial systems causes a variety of social problems. Recently, many studies have been conducted on bio-refineries, which aim to actively utilize biomass to reduce the use of fossil fuels and solve various social problems. Among them, research using microalgae as a third-generation biomass has attracted considerable attention. Microalgae use inorganic matter to produce organic matter, and cell destruction is necessary to extract useful organic materials from microalgae. The extracted organic materials are currently used in various industrial fields. Numerous cell-destruction methods exist. We have investigated cell disruption by sonication, especially its efficiency. Ultrasound is a sound wave with frequencies above 20 kHz, and destroys cells by sending high energy through a cavitation that occurs, according to the characteristics of the sound wave. The Dunaliella salina microalgae used in this study was cultured in a flat-type photobioreactor. Experiments were performed using a batch low-frequency processing device. Logistic model was applied to analyze the results of cell-destruction experiments using ultrasound. The proper conditions for the most efficient cell destruction were OD 1.4(microalgae concentration)), 54watt(output power) and 200mL(microalgae capacity).

초음파 기반 혈뇌장벽 개방에 관한 최신 임상시험 연구 현황 (Recent clinical trials with ultrasound induced blood-brain barrier opening)

  • 박주영
    • 한국음향학회지
    • /
    • 제41권5호
    • /
    • pp.564-569
    • /
    • 2022
  • 인체의 다른 장기들과 달리, 뇌는 혈뇌장벽(Blood-Brain Barrier, BBB)라는 보호 장치가 존재하여 뇌혈관내 물질들이 뇌조직으로 투과되는 것을 제한하는 역할을 한다. 이러한 BBB는 알츠하이머, 뇌종양 등 다양한 뇌질환에 직접적으로 전달이 필요한 약물의 투과까지 제한하기 때문에 치료 효능 검증 및 임상 적용이 어려운 것으로 보고되고 있다. 이러한 문제를 극복하기 위해 비침습적 특성의 집속 초음파(Focused Ultrasound, FUS)를 뇌의 국소 부위에 조사할 경우 마이크로버블의 음향공동화 현상으로 인해 BBB가 일시적으로 개방될 수 있는 기술이 개발되었으며, 해당 기술을 안전성 및 유효성 검증, 약물 전달 효율을 증대시킬 수 있는 다양한 연구가 전 세계적으로 수행되고 있다. 따라서, 본 논문에서는 알츠하이머, 뇌종양 등 뇌질환 치료를 위해 활발히 연구가 진행중인 집속초음파 기반 BBB 개방 기술에 대한 연구 동향을 분석하였다.

의료기기의 구매결정요인과 만족 및 재구매 의도의 구조적 관계에 관한 연구 : 초음파영상진단장치를 중심으로 (A Study on the Structural Relation among Purchase Decision Factors of Medical Devices, Satisfaction and Repurchasing Intention : Focused on Ultrasound Imaging System)

  • 정태영;서건석;김수범
    • 한국산학기술학회논문지
    • /
    • 제16권5호
    • /
    • pp.3308-3314
    • /
    • 2015
  • 본 연구의 목적은 의료기기의 구매결정요인과 만족 및 재구매 의도의 구조적 관계를 파악하는 것이다. 본 연구의 자료는 보건복지부의 2012년 의료기관 의료기기 사용실태조사이며, 이 중 초음파영상진단장치를 보유하고 있는 종합병원급 이상의 116개 의료기관을 분석하였다. AMOS 21 Ver.를 사용하여 확인적 요인분석과 구조방정식을 실시했으며, 주요 결과는 다음과 같다. 첫째, 의료기기 구매결정요인 중 브랜드는 만족에 유의한 영향을 주었으며, 만족은 다시 재구매 의도에 유의한 영향을 미쳤다. 둘째, 성능과 서비스는 유의하지 않지만 만족에 정의 영향을 주었으며, 가격은 만족에 부의 영향을 주었으나 유의하지 않은 것으로 나타났다. 본 연구는 의료기기 구매결정에 관한 실증적 연구가 부족한 상황에서, 확인적 요인분석을 토대로 하여 실증적으로 의료기기 구매결정요인을 제시했으며, 의료기기 시장의 효율적인 마케팅 전략 수립과 의료기기산업의 경쟁력 제고에 관한 기초자료를 제공했다는데 그 의의가 있다.