• Title/Summary/Keyword: Ultrasound Medical Imaging

Search Result 292, Processing Time 0.031 seconds

Laser-assisted Delivery of a Combined Antioxidant Formulation Enhances the Clinical Efficacy of Fractional Microneedle Radiofrequency Treatment: A Pilot Study

  • Kim, Jihee;Kim, Soo Min;Jung, Bok Ki;Oh, Sang Ho;Kim, Young-Koo;Lee, Ju Hee
    • Medical Lasers
    • /
    • v.10 no.3
    • /
    • pp.161-169
    • /
    • 2021
  • Background and Objectives Fractional microneedle radiofrequency systems are popular options to increase elasticity in aging skin. Laser-assisted drug delivery is a promising method for the epidermal injection of topically applied drugs and cosmetic ingredients. This study assesses the safety and efficacy of topical delivery of L-ascorbic acid, vitamin E, and ferulic acid after fractional microneedle radiofrequency treatment for reducing photodamage. Materials and Methods In this prospective, single-center, split-face, controlled pilot study, six women (mean age, 48.0 years; range, 35-57 years; Fitzpatrick skin types III and IV) exhibiting mild to moderate photodamage, underwent a single session of fractional microneedle radiofrequency treatment. The patients were instructed to apply the antioxidant formulation to only one side of the face. Patients were evaluated 3 days, 7 days, and 4 weeks thereafter, using three-dimensional imaging and ultrasound. Ex vivo, the full-thickness human skin was used for molecular and histological evaluation. Statistical analysis was achieved by applying t-tests, Mann-Whitney U tests, and one-way analyses of variance. Results Compared to the untreated side, the antioxidant-treated side exhibited a significant increase in dermal thickness (10.32% vs. 17.54%, p < 0.05), but not in skin elasticity (4.76% vs. 4.69%, p > 0.05). The difference in erythema between the sides was statistically not significant (p > 0.05). In the ex vivo model, expression of FGF2 in the skin was significantly increased after application of the antioxidant formulation, as compared to results obtained subsequent to fractional microneedle radiofrequency treatment only (p < 0.01). Conclusion This study demonstrates that for the treatment of photodamaged skin, laser-assisted delivery of the antioxidant formulation is a safe and effective adjuvant modality following fractional microneedle radiofrequency.

Comparison of the Ratio of Thicknesses of the Rhomboid Major and Middle Trapezius Muscles While Performing Scapular Retraction Exercises (어깨뼈 뒤 당김 운동 방법에 따른 큰마름근과 중간등세모근의 근두께비의 비교)

  • Park, Heon-mi;Kim, Suhn-yeop
    • Physical Therapy Korea
    • /
    • v.29 no.2
    • /
    • pp.131-139
    • /
    • 2022
  • Background: Shoulder impingement syndrome, a major cause of shoulder pain, involves weakness of the scapular retractor muscles. The major scapular retractor muscles are the middle trapezius and rhomboid major muscles; however, the latter is excluded in most studies. Objects: We aimed to measure the thickness of the middle trapezius and rhomboid major muscles using an ultrasonic diagnostic imaging system while performing four different shoulder retraction exercises and comparing the thicknesses and ratio of the thicknesses of these muscles. Methods: The thickness of the middle trapezius and rhomboid major muscles was measured in 24 healthy adults using ultrasound. Muscle thickness was measured three times in the Reference posture and four times while performing four different exercises that involved scapular retraction. The averages and standard deviations of the measured muscle thicknesses were obtained and compared. The ratio of muscle thickness and rate of changes in muscle thickness between the reference posture and the four exercises were compared. Results: For both, male (n = 10) and female (n = 14), there was a significant difference in the thickness of the middle trapezius muscle between the reference posture and the four exercises (p < 0.05) and in the thickness of the middle trapezius and rhomboid major muscles between male and female (p < 0.05); however, there was no significant difference in the ratio of the thicknesses of these muscles. Although a significant difference in the rate of change in muscle thickness during the four exercises was noted, there was no significant difference in the ratio of change in muscle thickness. Conclusion: This study demonstrates the ratio of the thicknesses of the middle trapezius and rhomboid major muscles and the rate of change in their thickness during exercises involving scapular retraction in healthy people in their 20s-30s.

The Effectiveness of 448-kHz Capacitive Resistive Monopolar Radiofrequency for Subcutaneous Fat Reduction in a Porcine Model

  • Kwon, Tae-Rin;Lee, Sung-Eun;Kim, Jong Hwan;Jeon, Yong Jae;Jang, You Na;Yoo, Kwang Ho;Kim, Beom Joon
    • Medical Lasers
    • /
    • v.8 no.2
    • /
    • pp.64-73
    • /
    • 2019
  • Background and Objectives The effectiveness of many physiotherapy modalities in reducing subcutaneous fat has been investigated in numerous previous studies. However, to the best of our knowledge, there have been no attempts to determine the effectiveness of physiotherapy modalities in body contouring. The present report determined the effect of 448-kHz capacitive resistive monopolar radiofrequency (CRMRF) in a porcine model. Materials and Methods This study investigated the effect of selective destruction of the subcutaneous fat layer in abdominal fat tissue using CRMRF. The effects of two types of CRMRF (capacitive electric transfer (CET) and resistive electric transfer (RET)) treatment were evaluated using regular digital photography in addition to thermal imaging evaluation, ultrasound measurement, hematological evaluation, and histologic analyses (H&E (hematoxylin and eosin), Oil red O, and immunohistochemistry staining). Results Preclinical evaluation was performed to obtain the data for comparison of the safety and efficacy of the subcutaneous fat reduction after applying CRMRF using CET and RET. After treatment, the thermal transmission was effective, and a 42-47℃ temperature change was observed in the fat layer while an approximately temperature of 42℃ was confirmed on the skin surface. Moreover, after the application of both types of CRMRF treatment, fibrotic septa were observed in the adipose tissue induced by heat at the treatment sites. TUNEL staining was also performed to confirm the process of apoptosis in the adipocytes. Conclusion These results suggest that both CET and RET for CRMRF treatment are safe and effective for subcutaneous fat reduction in a porcine model.

A Comparison of Gluteus Maximus Muscle and Biceps Femoris Muscle Thickness According to Weight Load during Prone Hip Extension with Knee Flexion Exercises (엎드려 무릎관절 굽힘 자세에서 엉덩관절 폄 동작 시 무게 부하 변화에 따른 큰볼기근과 넙다리두갈래근의 두께 비교)

  • Eun-Mi Jang;Da-Eun Jung
    • PNF and Movement
    • /
    • v.21 no.3
    • /
    • pp.309-317
    • /
    • 2023
  • Purpose: This study set out to investigate the effects of prone hip extension with knee flexion (PHEKF) exercises according to external load on the thickness of the gluteus maximus (Gmax) and biceps femoris (BF). Methods: Twenty-three healthy men participated in this study. All subjects randomly practiced PHEKF under the burden of external loads created by sandbags (0 kg, 1 kg, and 2 kg). Rehabilitative ultrasound imaging (RUSI) was used to measure the thickness of the Gmax and BF during the PHEKF with different external loads. Results: The thickness of the Gmax was highest during the 2 kg resistance exercise and lowest at 0 kg. The thickness of the Gmax was significantly increased at 1 kg and 2 kg compared to 0 kg and significantly increased at from 1 kg to 2 kg (p < 0.05). The thickness of the biceps femoris was highest at 0 kg and lowest at 2 kg. The thickness of the biceps femoris muscle was significantly reduced at 1 kg and 2 kg compared to 0 kg (p < 0.05), but there was no significant difference between 1 kg and 2 kg (p > 0.05). Conclusion: The thickness of the Gmax was increased by applying PHEKF with a higher external load, whereas the muscle thickness of the biceps femoris decreased. These results suggest that the application of external loads during PHEKF exercises may be an effective method for selective strengthening of the Gmax.

Correlation Analysis between Cervical-Vertebra Angle and Neck Range of Motion, Muscle Strength, and Sternocleidomastoid Thickness (전방머리자세 대상자의 머리-척추각과 목 운동범위, 근력, 목빗근 두께와의 상관관계 분석)

  • Min Ji Kang;Geun Tae Park;Jin Tae Han
    • Journal of Korean Physical Therapy Science
    • /
    • v.31 no.1
    • /
    • pp.88-97
    • /
    • 2024
  • Background: This study was to investigate effects of Correlation Analysis between Cervical-Vertebra Angle and Neck Range of Motion, Muscle Strength, Sternocleidomastoid Thickness of Patients with Forward Head Posture Design: Correlation Analysis. Methods: The subjects of this study were a total of 54 people in the forward head position and their ages were between 30 and 50 years old. The subjects cranio-vertebral angles, neck extension, neck flexion, neck rotation angles, neck flexor strength, neck extensor strength, sternocleidomastoid thickness were evaluated through measuring instruments. The thickness of the sternocleidomastoid muscle was measured using an imaging ultrasound diagnostic device (ultra sound, Versana Premier, GE Medical systems, China). CVA was measured by measuring the side photo of the subject was taken with a camera and evaluated.. neck joint range of motion was measured through digital inclinometer for extension, flexion, and neck rotation. neck muscle strength was measured by measuring the using a digital sthenometer. Data analysis in this study was statistically processed using SPSS version 26.0 (IBM SPSS Inc., USA). Correlation analysis was used and the statistical significance level was set at 0.05. Results: The results neck extension(r= 0.70**), neck flexion(r= 0.67**), neck rotation(r= 0.56**), neck extensor muscle strengt(r= 0.85**), neck flexor muscle strength(r= 0.66**), sternocleidomastoid thicknes(r= -0.81**) It indicates that there is a correlation. Conclusion:These results improve the Cervical-vertebra angle of patients with forward head posture should include a program to improve the thickness of the SCM. In the future, study can be used as an evidentiary material for treatment interventions to improve the Cervical-vertebra angle of patients with forward head posture.

Nondestructive Inspection of Steel Structures Using Phased Array Ultrasonic Technique (위상배열 초음파기법을 이용한 강구조물의 비파괴 탐상)

  • Shin, Hyeon-Jae;Song, Sung-Jin;Jang, You-Hyun
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.20 no.6
    • /
    • pp.538-544
    • /
    • 2000
  • A phased array ultrasonic nondestructive inspection system is being developed to obtain images of the interior of steel structures by modifying a medical ultrasound imaging system. The medical system consists of 64 individual transceiver channels that can drive 128 array elements. Several modifications of the system were required mainly due to the change of sound speed. It was necessary to fabricate array transducers for steel structure and to obtain A-scan signal that is necessary for the nondestructive testing. Boundary diffraction wave model was used for the prediction of radiation beam field from array transducers, which provided guidelines to design array transducers. And a RF data acquisition board was fabricated for the A-scan signal acquisition along a selected un line within an image. For the proper beam forming in the transmission and reception for steel structure, delay time was controlled. To demonstrate the performance of the developed system and fabricated transducers, images of artificial specimens and A-scan signals for selected scan lines were obtained in a real time fashion.

  • PDF

Polarization-sensitive Optical Coherence Tomography Imaging of Pleural Reaction Caused by Talc in an ex vivo Rabbit Model (생체 외 토끼 모델에서의 탈크에 의해 유발되는 흉막 반응의 편광 민감 광 결맞음 단층촬영 이미징)

  • Park, Jung-Eun;Xin, Zhou;Oak, Chulho;Kim, Sungwon;Lee, Haeyoung;Park, Eun-Kee;Jung, Minjung;Kwon, Daa Young;Tang, Shuo;Ahn, Yeh-Chan
    • Korean Journal of Optics and Photonics
    • /
    • v.31 no.1
    • /
    • pp.1-6
    • /
    • 2020
  • The chest wall, an organ directly affected by environmental particles through respiration, consists of ribs, a pleural layer and intercostal muscles. To diagnose early and treat disease in this body part, it is important to visualize the details of the chest wall, but the structure of the pleural layer cannot be seen by chest computed tomography or ultrasound. On the other hand, optical coherence tomography (OCT), with a high spatial resolution, is suited to observe pleural-layer response to talc, one of the fine materials. However, intensity-based OCT is weak in providing information to distinguish the detailed structure of the chest wall, and cannot distinguish the reaction of the pleural layer from the change in the muscle by the talc. Polarization-sensitive OCT (PS-OCT) takes advantage of the fact that specific tissues like muscle, which have optical birefringence, change the backscattered light's polarization state. Moreover, the birefringence of muscle associated with the arrangement of myofilaments indicates the muscle's condition, by measuring retardation change. The PS-OCT image is interpreted from three major perspectives for talc-exposure chest-wall imaging: a thickened pleural layer, a separation between pleural layer and muscle, and a phase-retardation measurement around lesions. In this paper, a rabbit chest wall after talc pleurodesis is investigated by PS-OCT. The PS-OCT images visualize the pleural layer and muscle, respectively, and this system shows different birefringence of normal and damaged lesions. Also, an analyisis based on phase-retardation slope supports results from the PS-OCT image and histology.

Changes of abdominal muscle thickness during stable and unstable surface bridging exercise in young people

  • Kim, Tae Hoon;Hahn, Joohee;Jeong, Ju-Ri;Lee, Changjoo;Kim, You Jin;Choi, Sung Min;Jeon, Da Young;Lee, Jin Hwa;Lim, In-Hyuk;Lee, Wan-Hee
    • Physical Therapy Rehabilitation Science
    • /
    • v.5 no.4
    • /
    • pp.210-214
    • /
    • 2016
  • Objective: The aim of this study was to measure the muscle architectural parameters of abdominal muscles in healthy individuals by rehabilitative ultrasound imaging (RUSI) and to investigate their changes after bridging exercise in various environments. Design: Cross-sectional study. Methods: The study included 40 healthy participants (19 men, 21 women). Subjects were randomly allocated to a stable surface group (SG, n=20) or an unstable surface group (UG, n=20). The participants assumed three positions in rest, bridging exercise with knee flexion $60^{\circ}$, and bridging exercise with knee flexion $90^{\circ}$ for the measurement of abdominal muscle thickness by RUSI. For the resting position, the participants held the head neutral in a hook-lying position and the dominant side was measured. For contraction, the participants performed the bridging exercise with the knee joint in $60^{\circ}$ and $90^{\circ}$ of flexion for 10 seconds each. Results: For transversus abdominis, external oblique muscle thickness, within the stable surface group and the unstable surface group, no significant contraction difference was observed in both the $60^{\circ}$ and $90^{\circ}$ bridge exercise conditions. Contraction difference of internal oblique muscle was significantly larger at $90^{\circ}$ than at $60^{\circ}$ within the SG (p<0.05). But within the UG, no significant contraction difference was shown. There was no significant contraction difference between the surface group and the unstable SG at $60^{\circ}$ condition and at $90^{\circ}$ condition in all measured muscles. Conclusions: The contraction difference is different for each muscle during bridge exercise with knee flexion $60^{\circ}$ and bridging exercise with knee flexion $90^{\circ}$. Muscle contraction difference is generally large when exercised on an unstable surface than a stable surface, but these are not statistically significant when bridging exercise is performed using dynamic air cushion for unstable surface.

Clinicopathologic Characteristics of Incidentally Discovered Thyroid Carcinomas (갑상선 우연암종의 임상병리적 특성)

  • Chung Woung-Youn;Cheong Jae-Ho;Chang Hang-Seok;Park Cheong-Soo
    • Korean Journal of Head & Neck Oncology
    • /
    • v.16 no.1
    • /
    • pp.64-68
    • /
    • 2000
  • Objectives: With the recent advances and increasing use of imaging techniques in examination of the neck, the incidence of incidentally discovered thyroid carcinoma has been increasing. This study was carried out to evaluate the clinicopathologic characteristics of incidental thyroid carcinomas and to find optimal therapeutic strategies for these lesions. Materials & Methods: From Jan. 1988 to Aug. 1998, 1,053 patients were operated on for thyroid cancer, of whom 127(12.1%) had incidentally discovered thyroid cancers which were identified during routine health checkups(n=40), diagnostic procedures for unrelated medical conditions(n=39) and mass screening for thyroid cancer(n=48). The preoperative diagnosis was obtained by ultrasound-guided FNAB and the extent of surgery was determined based on frozen section examinations, as well as prognostic factors and gross findings at the time of surgery. Results: There were 6 men and 121 women with a mean age of 45.9 years. Histopathological diagnosis included papillary carcinomas(n=1l9), follicular carcinomas(n=6), poorly differentiated carcinoma(n=l) and medullary carcinoma(n=1). Thirty patients(23.6%) had multifocallesions. The mean diameter of the tumors was 1.1 cm(0.2-3.4 cm). Capsular invasions were found in 53 patients(41.7%) and nodal metastases in 41(32.3%). The surgical procedures used were: 90 less-than total thyroidectomies and 37 total thyroidectomies with central neck node dissection. Lateral neck dissection was added in 5 patients. According to TNM staging, 79 patients(63.2%) were at stage I, 15(12.0%) at stage II, 31(24.8%) at stage III and 0(0.0%) at stage IV. By AMES scoring system, 102 patients(81.6%) were in the low-risk group and 23(18.4%) in the high-risk group. And by MACIS scoring system, 103(86.6%) of 119 papillary thyroid cancer patients were less than 6. Conclusions: The clinicopathological characteristics of incidentally discovered thyroid carcinomas are similar to ordinary thyroid carcinomas. The treatment of choice should be individualized based on the particular clinical situation encountered, as in ordinary thyroid carcinomas.

  • PDF

Clinical characteristics of Kikuchi disease in children (소아 Kikuchi 병의 임상 양상)

  • Chung, Sunghoon;Park, Sungsin;Lee, Kyuha;Song, Junhyuk;Han, Miyoung;Choi, Yongmook;Cha, Sungho;Park, Yongkoo
    • Pediatric Infection and Vaccine
    • /
    • v.14 no.2
    • /
    • pp.129-135
    • /
    • 2007
  • Purpose : Kikuchi disease is a subacute necrotizing lymphadenitis characterized by fever, cervical lymphadenopathy and benign self-limiting course in young women especially, but rare in children. Their etiopathology is still unknown, but involved viruses and autoimmune mechanism were proposed. We investigated the clinical and laboratory characteristics of Kikuchi disease in children. Methods : Five patients were diagnosed of Kikuchi disease from January 2001 to June 2006 in Kyunghee University Hospital. We reviewed their medical records retrospectively and analyzed clinical and laboratory findings. Results : The mean age of 5 patients (male to female ratio; 2:3) was 9 yr 9 mon(range: 8 yr 2 mon-12 yr 6 mon). The chief complaints were sustained fever and cervical lymph node that was unilateral, tender and swollen. All patients were treated with antibiotics before diagnosis was made, and rash developed in 2 patients. One patient showed necrotic change in ultrasound with which we suspected Kikuchi disease. Three patients were examined by CT scan additionally. The interval between admission and cervical lymph node excisional biopsy ranged from 6 days to 15 days, and mean period was 9.6 days. All pathological findings were compatible to necrotizing lymphandenitis. Conclusion : Unnecessary laboratory and imaging studies, and treatment with antibiotics tend to be done before making diagnosis, and that caused prolonged hospitalization. Therefore we studied the clinical and laboratory characteristics of Kikuchi disease in children.

  • PDF