• Title/Summary/Keyword: Ultrasound Intensity

Search Result 218, Processing Time 0.02 seconds

Extraction of Muscle Areas from Ultrasonographic Images using Information of Fascia (근막 정보를 이용한 초음파 영상에서의 근육 영역 추출)

  • Kim, Kwang-Baek
    • Journal of Korea Multimedia Society
    • /
    • v.11 no.9
    • /
    • pp.1296-1301
    • /
    • 2008
  • Ultrasonography constructs pictures of areas inside the body needs in diagnosis by bouncing high-enorgy sound waves(ultrasound) off internal tissues or organs. In constructing an ultrasonographic image, the weakness of bounding signals induces noises and detailed differences of brightness, so that having a difficulty in detecting and diagnosing with the naked eyes in the analysis of ultrasonogram. Especially, the difficulty is extended when diagnosing muscle areas by using ultrasonographic images in the musculoskeletal test. In this paper, we propose a novel image processing method that computationally extracts a muscle area from an ultrasonographic image to assist in diagnosis. An ultrasonographic image consists of areas corresponding to various tissues and internal organs. The proposed method, based on features of intensity distribution, morphology and size of each area, extracts areas of the fascia, the subcutaneous fat and other internal organs, and then extracts a muscle area enclosed by areas of the fascia. In the extraction of areas of the fascia, a series of image processing methods such as histogram stretching, multiple operation, binarization and area connection by labeling is applied. A muscle area is extracted by using features on relative position and morphology of areas for the fascia and muscle areas. The performance evaluation using real ultrasonographic images and specialists' analysis show that the proposed method is able to extract target areas being approximate to real muscle areas.

  • PDF

Response Properties of Meridians for focused variable electromagnetic stimulus (접속형 가변 전자계 자극에 대한 경락반응특성)

  • Lee, Gyoun-Jung;Cho, Dong-Guk;Kim, Soo-Byung;Kwon, Sun-Min;Shin, Tae-Min;Lee, Kyoung-Joung;Lee, Yong-Heum
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.13 no.7
    • /
    • pp.1399-1410
    • /
    • 2009
  • It is a method to treat pain using medication, neurotomy, and surgery. And acupuncture, ultrasound, electric treatment, and magnetic treatment are applied as a alternative physiotherapy. Electronic therapy is useful but it can be affected by impedance of skin or subcutaneous tissue. So, percutaneous stimulation is leading therapy, that is very randomly. We developed the system which can stimulate parts of acupuncture point noninvasively using the focused magnetic field. And we designed the magnetic stimulation electrode which is considered efficiency of the magnetic stimulation. It can make similar stimulation with manual acupuncture. To confirm the availability and reliability we compared Meridian Electronic Potential(MEP) change between manual acupuncture and magnetic stimulation. From this result, we found out the MEP changes of manual acupuncture and magnetic stimulation were similar. And there were various response properties as changes of stimulation method, intensity, and frequency. Also, the MEP change can be induced by electromagnetic stimulation. We confirmed that it is possible to use electromagnetic stimulation as a acupoint stimulation or pain treatment instrument.

Imaging Findings of Metaplastic Breast Carcinoma with Chondroid Differentiation: A Case Reports (연골성 분화를 보이는 화생성 유방암의 영상의학적 소견: 증례 보고)

  • Ji-Young Kim;Soung Hee Kim;Myeong Ja Jeong;Ji Hae Lee;Mi-Jin Kang;Geumhee Gwak;Su Hyun Yoo
    • Journal of the Korean Society of Radiology
    • /
    • v.83 no.6
    • /
    • pp.1385-1393
    • /
    • 2022
  • Metaplastic carcinoma of the breast is a heterogeneous group of neoplasms with mixed epithelial and mesenchymal differentiation. Metaplastic carcinoma of the breast is a rare and aggressive malignancy, with high recurrence and metastasis. Metaplastic carcinoma with chondroid differentiation is an uncommon subtype that tends to have a relatively good prognosis than that of other subtypes. We report the imaging features of three cases of pathologically proven metaplastic carcinoma with chondroid differentiation as follows: a high-density mass with amorphous or coarse heterogeneous calcifications on mammography; a microlobulated or partially indistinct, complex cystic, and solid mass on sonography; and a relatively circumscribed or partially indistinct, irregular mass with heterogeneous T2 high-signal intensity and heterogeneous or rim enhancement with initial fast enhancement and delayed washout on MRI.

Scoring System to Predict Malignancy for MRI-Detected Lesions in Breast Cancer Patients: Diagnostic Performance and Effect on Second-Look Ultrasonography (유방암 환자의 MRI에서 발견된 병변의 악성 예측을 위한 점수체계: 진단적 능력과 이차 초음파 결정에 미치는 영향)

  • Young Geol Kwon;Ah Young Park
    • Journal of the Korean Society of Radiology
    • /
    • v.81 no.2
    • /
    • pp.379-394
    • /
    • 2020
  • Purpose To design a scoring system to predict malignancy of additional MRI-detected lesions in breast cancer patients. Materials and Methods Eighty-six lesions (64 benign and 22 malignant) detected on preoperative MRI of 68 breast cancer patients were retrospectively included. The clinico-radiologic features were correlated with the histopathologic results using the Student's t-test, Fisher's exact test, and logistic regression analysis. The scoring system was designed based on the significant predictive features of malignancy, and its diagnostic performance was compared with that of the Breast Imaging-Reporting and Data System (BI-RADS) category. Results Lesion size ≥ 8 mm (p < 0.001), location in the same quadrant as the primary cancer (p = 0.005), delayed plateau kinetics (p = 0.010), T2 isointense (p = 0.034) and hypointense (p = 0.024) signals, and irregular mass shape (p = 0.028) were associated with malignancy. In comparison with the BI-RADS category, the scoring system based on these features with suspicious non-mass internal enhancement increased the diagnostic performance (area under the receiver operating characteristic curve: 0.918 vs. 0.727) and detected three false-negative cases. With this scoring system, 22 second-look ultrasound examinations (22/66, 33.3%) could have been avoided. Conclusion The scoring system based on the lesion size, location relative to the primary cancer, delayed kinetic features, T2 signal intensity, mass shape, and non-mass internal enhancement can provide a more accurate approach to evaluate MRI-detected lesions in breast cancer patients.

Developed an output device for high-frequency cosmetic medical equipment using micro multi-needle (마이크로 멀티니들을 이용한 고주파 피부미용 의료기기를 위한 출력 장치 개발)

  • Kim, Jun-tae;Joo, Kyu-tai;Cha, Eun Jong;Kim, Myung-mi;Jeong, Jin-hyoung
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.14 no.5
    • /
    • pp.394-402
    • /
    • 2021
  • The entry of an aging society and the extension of human life expectancy, the increasing interest in women's social advancement and men's appearance, and the natural interest in K-culture through media media, while receiving worldwide attention, Focus on K-Bueaty. Recently, looking at the occupation of the medical tourism field, in the case of aesthetic medicine tourism such as molding and dermatology, it has gained popularity not only in Asia such as China and Japan, but also in North America and Europe. The first external confirmation of human aging is the wrinkles on the skin of the face. Clean, wrinkle-free, elastic and healthy skin is a desire of most people. Skin condition and condition such as focused ultrasonic stimulation (HIFU: High Intensity Focused Utrasound) and low frequency, high frequency (RF: Radio Frequency), galvanic therapy using microcurrent, cryotherapy using rapid cooling, etc. Depending on the method of management, the effect of the treatment differs depending on the output and the stimulation site, etc., even in the treatment of medical equipment and beauty equipment using the same mechanism. In this research, in order to develop invasive high-frequency dermatological devices using a large number of beauty medical devices and microneedles of beauty devices, the international standards IEC 60601-2 (standards for individual medical devices) and MFDS (Ministry of) We designed and developed a high-frequency output device in compliance with the high-frequency stimulation standard announced in the Food and Drug Safety (Ministry of Food and Drug Safety). The circuit design consists of an amplifier (AMP: Amplifier) using Class-A Topology and a power supply device using Half-Bridge Topology. As a result of measuring the developed high-frequency output device, an average efficiency of 63.86% was obtained, and the maximum output was measured at 116.7W and 50.67dBm.

INHIBITORY EFFECT OF Er:YAG LASER ON THE GROWTH OF STREPTOCOCCUS MUTANS (Er:YAG 레이저 조사가 Streptococcus mutans의 증식억제에 미치는 효과)

  • Song, Gwang-Chul;Lee, Chang-Seop;Lee, Sang-Ho;Lee, Nan-Young
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.30 no.1
    • /
    • pp.15-24
    • /
    • 2003
  • The purpose of this study is to investigate the sterilization effect of Er:YAG laser against the intraoral acid producing bacterium, S. mutans, by irradiating the culture solution containing S. mutans KCTC 3065 with Er:YAG laser having a $650{\mu}m$ diameter beam through the non-contact method. We obtained the following results after examining the temperature changes of the culture solution, numbers of bacterial colonies, and acid-producing ability and attaching ability on teeth by measuring the amount of extracellular polysaccharide produced by S. mutans. The number of bacterial colony was decreased in $10{\mu}l$ culture solution irradiated with laser in overall compared to the control solution. The number decreased as the irradiation intensity and pulse repetition rate were larger and as the exposure time was increased. However, it did not change significantly in $100{\mu}l$ culture solution compared to the control solution. Although the acid-producing ability of S. mutans was inhibited for a certain duration after laser irradiation in 10r1 bacterial culture solution, it did not change in $100{\mu}m$ solution compared with the control solution. The amount of extracellular polysaccharide synthesized by S. mutans was partially decreased through laser irradiation in $10{\mu}m$ culture solution but did not change in $100{\mu}m$ culture solution. Based on these findings, we concluded that Er:YAG laser has an sterilization effect on S. mutans in which we presume that the mechanism is through the heat effect rather than the mechanical effect from development of ultrasound.

  • PDF

A Patterns of Care Study of the Various Radiation Therapies for Prostate Cancer among Korean Radiation Oncologists in 2006 (Patterns of Care Study를 위한 2006년 한국 방사선종양학과 전문의들의 전립선암 방사선치료원칙 조사연구)

  • Kim, Jin-Hee;Kim, Jae-Sung;Ha, Sung-Whan;Shin, Seong-Soo;Park, Won;Cho, Jae-Ho;Suh, Chang-Ok;Oh, Young-Taek;Shin, Sei-Won;Kim, Jae-Chul;Jang, Ji-Young;Nam, Taek-Keun;Choi, Young-Min;Kim, Il-Han
    • Radiation Oncology Journal
    • /
    • v.26 no.2
    • /
    • pp.96-103
    • /
    • 2008
  • Purpose: To conduct a nationwide academic hospital patterns of the practice status and principles of radiotherapy for prostate cancer. The survey will help develop the framework of a database of Korean in Patterns of Case Study. Materials and Methods: A questionnaire about radiation treatment status and principles was sent to radiation oncologists in charge of prostate cancer treatment at thirteen academic hospitals in Korea. The data was analyzed to find treatment principles among the radiation oncologists when treating prostate cancer. Results: The number of patients with prostate cancer and treated with radiation ranged from 60 to 150 per academic hospital in Seoul City and 10 to 15 outside of Seoul City in 2006. The primary diagnostic methods of prostate cancer included the ultrasound guided biopsy on 6 to 12 prostate sites(mean=9), followed by magnetic resonance imaging and a whole body bone scan. Internal and external immobilizations were used in 61.5% and 76.9%, respectively, with diverse radiation targets. Whole pelvis radiation therapy(dose ranging from 45.0 to 50.4 Gy) was performed in 76.9%, followed by the irradiation of seminal vesicles($54.0{\sim}73.8$ Gy) in 92.3%. The definitive radiotherapy doses were increased as a function of risk group, but the range of radiation doses was wide(60.0 to 78.5 Gy). Intensity modulated radiation therapy using doses greater than 70 Gy, were performed in 53.8% of academic hospitals. In addition, the simultaneous intra-factional boost(SIB) technique was used in three hospitals; however, the target volume and radiation dose were diverse. Radiation therapy to biochemical recurrence after a radical prostatectomy was performed in 84.6%; however, the radiation dose was variable and the radiation field ranged from whole pelvis to prostate bed. Conclusion: The results of this study suggest that a nationwide Korean Patterns of Care Study is necessary for the recommendation of radiation therapy guidelines of prostate cancer.

Polarization-sensitive Optical Coherence Tomography Imaging of Pleural Reaction Caused by Talc in an ex vivo Rabbit Model (생체 외 토끼 모델에서의 탈크에 의해 유발되는 흉막 반응의 편광 민감 광 결맞음 단층촬영 이미징)

  • Park, Jung-Eun;Xin, Zhou;Oak, Chulho;Kim, Sungwon;Lee, Haeyoung;Park, Eun-Kee;Jung, Minjung;Kwon, Daa Young;Tang, Shuo;Ahn, Yeh-Chan
    • Korean Journal of Optics and Photonics
    • /
    • v.31 no.1
    • /
    • pp.1-6
    • /
    • 2020
  • The chest wall, an organ directly affected by environmental particles through respiration, consists of ribs, a pleural layer and intercostal muscles. To diagnose early and treat disease in this body part, it is important to visualize the details of the chest wall, but the structure of the pleural layer cannot be seen by chest computed tomography or ultrasound. On the other hand, optical coherence tomography (OCT), with a high spatial resolution, is suited to observe pleural-layer response to talc, one of the fine materials. However, intensity-based OCT is weak in providing information to distinguish the detailed structure of the chest wall, and cannot distinguish the reaction of the pleural layer from the change in the muscle by the talc. Polarization-sensitive OCT (PS-OCT) takes advantage of the fact that specific tissues like muscle, which have optical birefringence, change the backscattered light's polarization state. Moreover, the birefringence of muscle associated with the arrangement of myofilaments indicates the muscle's condition, by measuring retardation change. The PS-OCT image is interpreted from three major perspectives for talc-exposure chest-wall imaging: a thickened pleural layer, a separation between pleural layer and muscle, and a phase-retardation measurement around lesions. In this paper, a rabbit chest wall after talc pleurodesis is investigated by PS-OCT. The PS-OCT images visualize the pleural layer and muscle, respectively, and this system shows different birefringence of normal and damaged lesions. Also, an analyisis based on phase-retardation slope supports results from the PS-OCT image and histology.