• Title/Summary/Keyword: Ultrasonic diagnosis

Search Result 211, Processing Time 0.028 seconds

Assessment of Bearing Damage by Ultrasonic Measurement (초음파 측정에 의한 베어링손상 평가)

  • LEE SANG-GUK;LEE In-CHEOL
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.395-400
    • /
    • 2004
  • For the purpose of monitoring by ultrasonic test of the ball bearing conditions in rotating machinery, a system for their diagnosis was developed. ultrasonic technique is used to detect abnormal conditions in the bearing system. And various data such as frequency spectrum, energy and amplitude of ultrasonic signals, and ultrasonic parameters were acquired during experiments with the simulated ball bearing system. Based on the above results and practical application for power plant, algorithms and judgement criteria for diagnosis system was established. Bearing diagnosis system is composed of four parts as follows : sensing part for ultrasonic sensor and preamplifier, signal processing part for measuring frequency spectrum, energy and amplitude, interface part for connecting ultrasonic signal to PC using A/D converter, graphic display and software part for display of bearing condition and for managing of diagnosis program.

  • PDF

A Study on Damage Evaluation of Bearings for Rotating Machinery in Power Plant Using Ultrasonic Wave (초음파를 이용한 발전용 회전기기 베어링 손상상태 평가 연구)

  • Lee, Sang-Guk;Lee, Sun-Ki;Lee, Do-Hwan;Park, Sung-Keun
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.32 no.7
    • /
    • pp.583-589
    • /
    • 2008
  • For the purpose of monitoring by ultrasonic test of the ball bearing conditions in rotating machinery, a system for their diagnosis was developed. ultrasonic technique is used to detect abnormal conditions in the bearing system. And various data such as frequency spectrum, energy and amplitude of ultrasonic signals, and ultrasonic parameters were acquired during experiments with the simulated ball bearing system. Based on the above results and practical application for power plant, algorithms and judgement criteria for diagnosis system was established. Bearing diagnosis system is composed of four parts as follows : sensing part for ultrasonic sensor and preamplifier, signal processing part for measuring frequency spectrum, energy and amplitude, interface part for connecting ultrasonic signal to PC using A/D converter, graphic display and software part for display of bearing condition and for managing of diagnosis program.

A Study on the Ultrasonic Measurement for Damage Evaluation of Power Plant Bearing (발전용 베어링 손상평가를 위한 초음파 측정 연구)

  • Lee, Sang-Guk
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.1727-1732
    • /
    • 2004
  • For the purpose of monitoring by ultrasonic test of the ball bearing conditions in rotating machinery, a system for their diagnosis was developed. ultrasonic technique is used to detect abnormal conditions in the bearing system. And various data such as frequency spectrum, energy and amplitude of ultrasonic signals, and ultrasonic parameters were acquired during experiments with the simulated ball bearing system. Based on the above results and practical application for power plant, algorithms and judgement criteria for diagnosis system was established.

  • PDF

A Study of Ultrasonography in One Congenital Hydrocephalus Case Accompanied with Meningoencephalocele (수막뇌류(髓膜腦瘤)를 수반(隨伴)한 선천성뇌수종(先天性腦水腫) 1례(例)의 초음파소견(超音波所見)에 관한 보험의학적(保險醫學的) 연구(硏究))

  • Han, Hye-Jin;Kim, Kang-Seuck
    • The Journal of the Korean life insurance medical association
    • /
    • v.2 no.1
    • /
    • pp.245-252
    • /
    • 1985
  • Ultrasonographic examination in the obstetrics not only makes easy of the diagnosis of Hydrocephalus, placenta previa, anencephalus and ectopic pregnancy, etc, but also guaranteed its excellence in the diagnosis of women gynecology disease. Especially in case that it doesn't affect radiation hazard on the embryo, its efficiency keeps increasing and it is spotlighted to many clinic doctors. Even though in general hospital we often observe congenital hydrocephalus in Med. Dept. which entirly undergoes the medical examination to the insured, we don't observe even the women delivered with child and it is very difficult to find a rare congenital hydrocephlus throughout other present insurance companies. We inspected a congenital hydrocephalus, which other medical equipments of present insurance companies have many difficulties in the medical examination, accompanied by meningoencephalocele by ultrasonic diagnosis. We analyzed and compared the data by ultrasonic diagnosis with that of surgical diagnosis and the results are follows; 1) We could correctly describe meningoencephalocele by ultrasonic diagnosis. 2) It was able to be diagnosed in LMP 22 weeks. 3) BPD has about 10 mm higher than normal value in LMP 22 weeks. 4) Dilatation of lateral ventricle was observed in LMP 22 weeks. 5) As paralled with ultrasonic diagnosis in pregnancy medical examination, accepting declines including the risk rate can be restrained.

  • PDF

A diagnosis system and ultrasonic vibration energy in plant to quality control

  • Suh, Chang-Min;Song, Gil-Ho;Pyoun, Young-Shik;Kim, Seong-Yun
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2006.11a
    • /
    • pp.29-34
    • /
    • 2006
  • In this paper, the mechanical characteristics of ultrasonic cold forged technology (UCFT) used for the trimming knife and the effects of ultrasonic vibration energy (UVE) into the trimming process on the state of the strip cutting face were studied. And a diagnosis system to quality control for trimming knife and strip cutting face was developed and installed in plant. By the plant application of UCFT, service life of knife was more increased over 100% than that of conventional knife. And using the developed diagnosis system, the knife breakage and saw ear have been perfectly detected and quality control of trimming face is obtained effectively.

  • PDF

A Study on Ultrasonic Image Diagnosis Methods of Tooth Defect with Phased-Array Techniques (위상배열기법을 이용한 치아결함 초음파이미지 진단기술개발)

  • Oh, Yun-Jung;Hwang, In-Nam;Park, Su-Jung;Im, Kwang-Hee;Cho, Hyun-Joon;Cho, Young-Tae
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.18 no.6
    • /
    • pp.604-613
    • /
    • 2009
  • Recently, researches to develop phased array ultrasonic examination techniques are proceeded to diagnose dental caries and the status of surgical operation of dental implant. Sound field analysis of phased array ultrasonic transducers were carried out in order to characterizing the ultrasonic phased array beams. The sound field of ultrasonic radiation was calculated for the sample called "gypsum-improved stone" with the similar characteristics of dental materials. Industrial phased array ultrasonic devices were utilized for the insptriion of the artificial flaws machined in the gypsum-improved stone. Dental implants were made at the pig jaw bone and defect images were confirmed for the dental implants.

  • PDF

Development of Ultrasonic Sensor for Engine Condition Diagnosis of EDG (비상디젤발전기 엔진 상태진단 초음파 탐촉자 개발)

  • Lee, Sang-Guk;Choi, Kwang-Hee
    • Journal of Power System Engineering
    • /
    • v.17 no.4
    • /
    • pp.31-35
    • /
    • 2013
  • The emergency AC power supply system of the nuclear power plant is designed to supply the power to the nuclear power plant at the emergency operating condition. The safety function of the diesel generator at the nuclear power plant is to supply AC electric power to the safety system whenever the preferred AC power supply is unavailable. The reliable operation of onsite standby diesel generator should be ensured by a condition monitoring system designed to maintain, monitor and forecast the reliability level of diesel generator. The purpose of this paper is to improve the existing ultrasonic sensor used for condition diagnosis of engine fuel pump and cylinder head for the accurate diagnosis in actual engine condition of emergency diesel generator(EDG). As a result of this study, we could design and develop much more reliable ultrasonic sensor than existing ones.

Ultrasonography in periodontal diagnosis (악안면 초음파의 치주학적 활용)

  • Kim, Dae-Yeob;Lee, Jong-Bin;Pang, Eun-Kyoung
    • The Journal of the Korean dental association
    • /
    • v.55 no.11
    • /
    • pp.800-807
    • /
    • 2017
  • Ultrasonography is one of the most common diagnostic tools in medical imaging with non-invasive and non-radiation loaded characteristics. In the field of dentistry, especially for periodontology, high frequency ultrasonic device can be used for several purposes such as evaluating gingival thickness, identifying the level of alveolar bone, measuring the volume of mucosa of donor site for soft tissue graft and so on. According to recent studies, it was demonstrated that ultrasonic diagnosis had both accuracy and repeatability comparable to conventional diagnostic tools. However, improvement and development of intra-oral probe suitable for adpatation to gingiva and palatal mucosa, are considered as prerequisites for diffusion of ultrasonic diagnosis in periodontology.

  • PDF

Application of the Ultrasonic Detection System for the Power Transformer (전력용 변압기 초음파 측정시스템 적용)

  • Kweon, Dong-Jin;Koo, Kyo-Sun;Kim, Jae-Chul
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.54 no.12
    • /
    • pp.553-557
    • /
    • 2005
  • This paper describes the application results of an ultrasonic detection system for the power transformer. The ultrasonic detection system with 6 sensors was applied to detect partial discharge in a 154kV transformer with a dangerous levels of $C_{2}H_{2},\;C_{2}H_4$ and $CH_{4}$ gases. The ultrasonic detection tests were carried out 2 times, respectively, to confirm the existence and location of the partial discharge in the transformer. As a result of internal inspection, the arc trace between the pressure ring and core due to the partial discharge was found at the estimated position based on the amplitude and arriving time of the ultrasonic signals. Therefore, it was verified that the ultrasonic detection system is effective as a preventive diagnosis method for the power transformer. Also, the reliability of the ultrasonic detection system in detecting partial discharges in the transformer was also confirmed. It is expected, therefore, that the ultrasonic detection system will have beneficial effects on applications and verifications in detecting partial discharges for the power transformer.

Medical Application of the Nondestructive Ultrasonic Tests: Diagnosis of Micro Bone Fractures using Ultrasonic C Scan Images (비파괴 초음파 검사법의 의학적 활용: 초음파 C 스캔 영상을 이용한 미세 골절의 진단)

  • Choi, Min-Joo
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.22 no.4
    • /
    • pp.377-385
    • /
    • 2002
  • Ultrasonic tests employing non-ionizing radiation are preferred in nondestructive examinations since they are safe and simple in use. The same principles of the techniques have been taken as valuable tools in medical area for the diagnoses of diseases, in other words, defects of the human body. The paper overviews the principles of the medical diagnosis based on nondestructive ultrasonic tests, and then evaluates experimentally the clinical potential of C scan images not popular in medicine, for detecting the micro fractures of the cortical bone. In the experiment the micro bone fractures were created on the femurs of porks by loading three point bending forces (2-4kN) with the speed of 1 mm/min. As the extent of the fracture was altered, not only X ray images but also ultrasonic C scan images using a focused ultrasonic probe resonated at 25 MHz were obtained. The results showed that ultrasonic C scan images were capable of detecting the micro bone fractures which were not possible to identify by conventional X ray images.