Abstract

Ultrasonic tests employing non-ionizing radiation are preferred in nondestructive examinations since they are safe and simple in use. The same principles of the techniques have been taken as valuable tools in medical area for the diagnoses of diseases, in other words, defects of the human body. The paper overviews the principles of the medical diagnosis based on nondestructive ultrasonic tests, and then evaluates experimentally the clinical potential of C scan images not popular in medicine, for detecting the micro fractures of the cortical bone. In the experiment the micro bone fractures were created on the femurs of porks by loading three point bending forces (2-4kN) with the speed of 1 mm/min. As the extent of the fracture was altered, not only X ray images but also ultrasonic C scan images using a focused ultrasonic probe resonated at 25 MHz were obtained. The results showed that ultrasonic C scan images were capable of detecting the micro bone fractures which were not possible to identify by conventional X ray images.

비전리 방사선을 이용하는 초음파 탐상법은 안전하며 사용이 간편하기 때문에 비파괴검사에서 매우 선호되고 있는 방법이다. 의학적으로 초음파 탐상법은 동일한 원리를 이용하여 인체의 결함 즉 질병의 진단을 위해 유용한 수단 요로 활용되고 있다. 본 논문에서는 초음파 탐상법에 기반한 의료용 초음파 진단의 원리에 대해 개관하고, 그동안 임상적으로 별로 주목받지 못한 초음파 C스캔 영상을 이용한 치밀골의 미세 골절 진단 가능성을 실험적으로 평가하였다. 실험에서는 돼지 대퇴골에 3점 굽힘 힘 (2-4 kN)을 1 mm/min 속도로 가해 미세 골절을 유발하였다. 골절의 정도를 변화하면서 골절에 대한 엑스선 영상과 25 MHz 접속형 초음파 변환기롤 이용하여 C스캔 영상을 취득하였다. 실험 결과 초음파 C 스캔 영상은 기존의 골절 진단법인 엑스선 영상에서는 진단이 어려운 미세한 골절까지 감지할 수 있음을 확인하였다.

Keywords

References

  1. C. R. Hill, Ed, Physical Principles of Medical Ultrasound, Ellis Horwood Ltd, Chichester, UK, (1996)
  2. P. Fish, Phsysics and Instrumentation of Diagnostic Medical Ultrasound, John Willey & Sons, New York, (1990)
  3. J. A. Zagzebski, Essentials of Ultrasound Physics, Mosby, London (1995)
  4. A. C. Kak and M Slaney, Principles of Computerized Torrographic Imaging, IEEE Press, New York, pp. 147-157, (1987)
  5. 진병문 역, ‘초음파에 의한 비파괴 검사,’ 초음파 분광학. 대웅, 서울, Chapter 8, (2000)
  6. P. N. T. Wells, Biomedical Ultrasonics, Academic Press, London, (1977)
  7. L. E. Kinsler, A. R. Frey, A. B. Coppens and J. V. Sanders, Funclarrentals of Acoustics, 4th ed, John Wiley & Sons, New York, (2000)
  8. F. A. Duck, Physical properties of Tissue: A comprehensive reference book, Academic Press, London, (1990)
  9. A. Oksala and H. Gemet, Ultrasonics in Opht:halrrology, New York, pp. 116-133, (1967)
  10. B. D. Burr, M R Forwood, D. P. Fyhrie, B. R. Martin, M. B. Schaffler and C. H. Thrner, ‘Bone microdamage and skeletal fragility in osteoporotic and stress fractures,’ Journal of Bone & Mineral Research, Vol. 12, pp. 6-15, (1997)
  11. B. D. Burr and T. Stafford, ‘Validity of the Bulk-staining technique to separate artifactual from in vivo bone microdamage,’ Clin. Orthop. Relat. Res., Vol. 260, pp. 350-380, (1994)
  12. 강성구, 김재영 , 이권전 , 고광섭 , 김소연, ‘피로골절 환자에서 골주사 소견과 방사선 소견의 비교’ 대한핵의학회지, Vol. 21, No.1, pp. 39-46, (1987)
  13. 서정탁, 안재민, ‘하퇴부에 발생한 피로골절 - 골주사등급과 자기공명영상등급의 비교와 자기공명영상소견의 분석,’ 대한스포츠의학회지, Vol. 17, No. 2, pp. 428-435, (1999)
  14. B. D. Burr and M. Hooser, ‘Alterations to the en bloc basic fuchsin staining protocol for the demonstration of microdamage produced in vitro,’ Bone, Vol. 71, No. 4, pp. 431-433, (1995)