• Title/Summary/Keyword: Ultrasonic Methods

검색결과 821건 처리시간 0.036초

Non-Destructive Detection of Hydride Blister in PHWR Pressure Tube Using an Ultrasonic Velocity Ratio Method

  • Cheong Yong-Moo;Lee Dong-Hoon;Kim Sang-Jae;Kim Young-Suk
    • Nuclear Engineering and Technology
    • /
    • 제35권5호
    • /
    • pp.369-377
    • /
    • 2003
  • Since Zr-2.5Nb pressure tubes have a high risk for the formation of blisters during their operation in pressurized heavy water reactors, there has been a strong incentive to develop a method for the non-destructive detection of blisters grown on the tube surfaces. However, because there is little mismatch in acoustic impedance between the hydride blisters and zirconium matrix, it is not easy to distinguish the boundary between the blister and zirconium matrix with conventional ultrasonic methods. This study has focused on the development of a special ultrasonic method, so called ultrasonic velocity ratio method for a reliable detection of blisters formed on Zr-2.5Nb pressure tubes. Hydride blisters were grown on the outer surface of the Zr-2.5Nb pressure tube using a cold finger attached to a steady state thermal diffusion equipment. To maximize a difference in the ultrasonic velocity in hydride blisters and the zirconium matrix, the ultrasonic velocity ratio of longitudinal wave to shear wave, $V_L/V_S$, has been determined based on the flight time of the longitudinal echo and reflected shear echo from the outer surface of the tubes. The feasibility of the ultrasonic velocity ratio method is confirmed by comparing the contour plots reproduced by this method with those of the blisters grown on the Zr-2.5Nb pressure tubes.

PZT를 이용한 다자유도 초음파 모터 개발 (Development of Multi-DOF Ultrasonic Motor Using PZT)

  • 손영완;다케무라 겐지로;박신석
    • 한국정밀공학회지
    • /
    • 제27권4호
    • /
    • pp.53-62
    • /
    • 2010
  • This study introduces about development of multi-DOF ultrasonic motor that are composed of a bar-shaped stator and a spherical rotor. The ultrasonic motor is a motor which is operated by vibrations over frequency of 20kHz. The multi-DOF ultrasonic motor will be developed by expanding the basic theory of existing 1-DOF ultrasonic motor. It can generate 3-DOF rotation of the rotor around perpendicular axes using 3 vibration modes of stator. By using finite element methods, the optimal dimension of stator is decided and made the components of stator. When we apply the multi-DOF ultrasonic motor composed of rotor and stator to the driving test system, it will be checked whether the motor can be driven at the direction of 3-DOF or not. And it is proposed how the simulation of square bar shaped multi-DOF ultrasonic motor is accomplished.

이동로봇의 거리측정을 위한 고성능 일체형 초음파 모듈 개발 (Development of Robust Single Ultrasonic Module for Distance Measurement of Mobile Robot)

  • 최종훈;심현민;유제군;이응혁
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 학술대회 논문집 정보 및 제어부문
    • /
    • pp.418-420
    • /
    • 2005
  • This paper proposed ultrasonic distance measurement module development for correct distance detection with collision escaping or obstacle of mobile robot is traveling self-regulation. Representative ultrasonic module applied in existing was Polaroid company's 6500 series and Devantech company's SRF04/SRF08 series. This ultrasonic sensors are corrupted by systematic errors due mainly to the dependency of sound speed upon surrounding conditions and random errors of uncertain origin. Therefore Ultrasonic distance detecting means of error compensation method and high definition, narrow beam angle, board area distance detecting means to apply to ultrasonic mobile robot control urgently need. In this paper use internal type temperature compensation method to improve problem of ultrasonic distance measurement method instead of that volume that have shortcoming of used correct temperature compensation methods applied big addition device. Compensate error by environment change of temperature. Humidity density etc. and is applicable to mobile robot offering various interface and real-time processing developed possible distance measurement module.

  • PDF

초음파적용 상온연무기의 분무특성에 관한 연구 (A Study on the Spray Characteristics of the Cold-Fog Spray with Ultrasonic Forcing)

  • 송민근;이경렬;손승우;나우정;주은선
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2002년도 학술대회지
    • /
    • pp.299-302
    • /
    • 2002
  • Characteristics of the twin fluid spray with ultrasonic forcing are examined in order to obtain the high efficiency of cold fog spray of the automatic pest control machine which has been widely used for the equipment cultivation recently. An electrostrictive vibrator of PZT BLT and a magnetostrictive vibrator of ${\pi}type$ with 28 kHz are applied as the ultrasonic transducer. All experiments are made and observed in 4 methods of spray ; a conventional spray method without ultrasonic forcing, an indirect vibration method with ultrasonic forcing, an improving duality method by ultrasonic forced within liquid, and a combined use method with both of the indirect vibration method and the improving quality method. In results, It was clarified that the ultrasonic effects the atomization of spray droplets and its efficiency is about $10{\%}$ and especially much more in the case of the combined use method.

  • PDF

Structural Design and Analysis for 3D Ultrasonic Anemometer

  • Kim, Kyung-Won;Choi, Jae-Yeong;Lee, Woo-Jin;Lee, Seon-Gil
    • 센서학회지
    • /
    • 제25권2호
    • /
    • pp.86-90
    • /
    • 2016
  • A 3D ultrasonic anemometer measures the direction and velocity of wind in a 3D space. The 2D ultrasonic anemometers developed by different manufacturers do not differ significantly in terms of their form or structure. The 3D ultrasonic anemometers, on the other hand, have more diverse forms than their 2D counterparts depending on the measurement algorithms and methods. Designing and reviewing the structure at the initial stage and defining its performance objectives are time-consuming processes. The process can be made cost-effective and time-saving if the validity is tested by model design and structural interpretation, and the structure is designed to withstand high wind velocities. This study presents the results of a 3D ultrasonic anemometer on real sample data by using a 3D modeling program, CATIA, for ultrasonic anemometer modeling.

Nondestructive Measurement of Cheese Texture using Noncontact Air-instability Compensation Ultrasonic Sensors

  • Baek, In Suck;Lee, Hoonsoo;Kim, Dae-Yong;Lee, Wang-Hee;Cho, Byoung-Kwan
    • Journal of Biosystems Engineering
    • /
    • 제37권5호
    • /
    • pp.319-326
    • /
    • 2012
  • Purpose: Cheese texture is an important sensory attribute mainly considered for consumers' acceptance. The feasibility of nondestructive measurements of cheese texture was explored using non-contact ultrasonic sensors. Methods: A novel non-contact air instability compensation ultrasonic technique was used for five varieties of hard cheeses to measure ultrasonic parameters, such as velocity and attenuation coefficient. Five texture properties, such as fracturability, hardness, springiness, cohesiveness, and chewiness were assessed by a texture profile analysis (TPA) and correlated with the ultrasonic parameters. Results: Texture properties of five varieties of hard cheese were estimated using ultrasonic parameters with regression analysis models. The most effective model predicted the fracturability, hardness, springiness, and chewiness, with the determination coefficients of 0.946 (RMSE = 21.82 N), 0.944 (RMSE = 63.46 N), 0.797 (RMSE = 0.06 ratio), and 0.833 (RMSE = 17.49 N), respectively. Conclusions: This study demonstrated that the non-contact air instability compensation ultrasonic sensing technique can be an effective tool for rapid and non-destructive determination of cheese texture.

초음파 가진을 이용한 2-유체 노즐의 효율 향상 (Improvement of the Efficiency of a Twin-fluid Nozzle using Ultrasonic Vibration)

  • 주은선;나우정;정진도;송민근;이경열
    • Journal of Biosystems Engineering
    • /
    • 제27권4호
    • /
    • pp.317-326
    • /
    • 2002
  • Characteristics of a twin-fluid spray with ultrasonic vibration were examined in order to obtain a high efficiency of cold-fog spray of the automatic pest control machine which has been widely used in protected horticulture recently. An electrostrictive vibrator of PZT BLT and a magnetostrictive $\pi$-type vibrator were used applied as the ultrasonic transducers with a frequency of 28 kHz. All experiments were conducted in 4 methods of spray ; a conventional spray method without ultrasonic forcing, an indirect vibration method with ultrasonic forcing, an improving-quality method by ultrasonic forced within liquid, and a combined-use method with both of the indirect vibration method and the improving quality method. It was found that the ultrasonic energy increased the atomization efficiency of spray droplets about 10% and especially much more in the case of the combined-use method.

Viscosity Characteristics of Waste Cooking Oil with Ultrasonic Energy Irradiation

  • Kim, Tae Han;Han, Jung Keun
    • Journal of Biosystems Engineering
    • /
    • 제37권6호
    • /
    • pp.429-433
    • /
    • 2012
  • Purpose: While rapeseed oil, soy bean oil, palm oil and waste cooking oil are being used for biodiesel, the viscosity of them should be lowered for fuel. The most widely used method of decreasing the viscosity of vegetable oil is to convert the vegetable oil into fatty acid methyl ester but is too expensive. This experiment uses ultrasonic energy, instead of converting the vegetable oil into fatty acid methyl ester, to lower the viscosity of the waste cooking oil. Methods: For irradiation treatment, the sample in a beaker was irradiated with ultrasonic energy and the viscosity and temperature were measured with a viscometer. For heating treatment, the sample in a beaker was heated and the viscosity and temperature were measured with a viscometer. Kinematic viscosity was calculated by dividing absolute viscosity with density. Results: The kinematic viscosity of waste cooking oil and cooking oil are up to ten times as high as that of light oil at room temperature. However, the difference of two types of oil decreased by four times as the temperature increased over $83^{\circ}C$. When the viscosity by the treatment of ultrasonic energy irradiation was compared to one by the heating treatment to the waste cooking oil, the viscosity by the treatment of ultrasonic energy irradiation was lower by maximum of 22% and minimum of 12%, than one by the heating treatment. Conclusions: Ultrasonic energy irradiation lowered the viscosity more than the heating treatment did, and ultrasonic energy irradiation has an enormous effect on fuel reforming.

유비쿼터스 컴퓨팅의 실내 측위 기술을 위한 U-SAT 시스템의 적용에 관한 연구 (A Study on the Application of U-SAT System for the Indoor Positioning Technology of Ubiquitous Computing)

  • 이동활;박종진;김수용;문영성;이만형
    • 제어로봇시스템학회논문지
    • /
    • 제12권9호
    • /
    • pp.876-882
    • /
    • 2006
  • This study presents an ultrasonic location awareness system for the ubiquitous computing with absolute position. The flight time of ultrasonic waves is determined by a period detecting technique which is able to extend the sensing range compared with traditional methods. For location awareness, ultrasonic waves are sent successively from each ultrasonic transmitter and synchronized by radio frequency (RF) signal, where the transmitting part is fixed and the receiving part is movable. To expand the recognizing range, cell matching technique and coded ultrasonic technique are introduced. The experimentation for various distances is accomplished to verify the used period detecting technique of U-SAT system. The positioning accuracy by using cell matching is also verified by finding the locations of settled points and the usability of coded ultrasonic technique is verified. As a result, the possibility of ultrasonic location awareness system for the ubiquitous computing can be discussed as a pseudo-satellite system with low cost, a high update rate, and relatively high precision, in the places where CPS is not available.

광중합용 DLP 프린터로 제작한 전악 인공치아의 UV-C 초음파 세척에 따른 체적 안정성 평가 (Evaluation of dimension stability according to UV-C ultrasonic cleaning of full arch artificial teeth made with DLP printer for photopolymerization)

  • 김동연;이광영
    • 대한치과기공학회지
    • /
    • 제43권3호
    • /
    • pp.84-92
    • /
    • 2021
  • Purpose: The purpose of this study was to compare the dimension safety evaluation between a general ultrasonic cleaner and an ultrasonic cleaner equipped with UV-C (ultraviolet-C). Methods: An edentulous model was prepared. A denture base and an occlusal rim were fabricated, and scanning was performed. After scanning, a denture base and full arch artificial teeth were designed. The full arch artificial teeth were printed using a three-dimensional printer (n=10). The residual resin was washed with alcohol and then scanned (reference data). The printed specimens were classified and cleaned using a general ultrasonic cleaner (GU group) and an ultrasonic cleaner equipped with UV-C (UC group). After each washing, a rescan was performed (scan data). Reference data and scan data were superimposed using overlapping software. Data were statistically analyzed using the Mann-Whitney test (α=0.05). Results: In the deviation values of full arch artificial teeth, the GU group showed a high deviation of 18.02 ㎛ and the UC group showed a low deviation of 15.02 ㎛. The two groups demonstrated a statistically significant difference (p<0.05). Conclusion: Full arch artificial teeth prepared using photopolymerized resin were deformed according to the temperature of water generated in the ultrasonic cleaner. It is judged that there is no deformation according to the UV-C ultrasonic cleaner.