• Title/Summary/Keyword: UV-sensor

검색결과 240건 처리시간 0.028초

A Study on the Relationship between Ultraviolet Rays and Skin Color Using a Photoplethysmography Sensor

  • So-Yae Hur;Sun-Jib Kim
    • International Journal of Advanced Culture Technology
    • /
    • 제11권1호
    • /
    • pp.363-369
    • /
    • 2023
  • In this study, to check the function of managing the severity of ultraviolet rays with a smart watch, a popular health care IT device, It was tested whether measuring heart rate using a PPG(Photoplethysmography) sensor representatively used in a smart watch could tell skin changes caused by ultraviolet rays. Through this experiment, we examined the possibility that the skin color tanned by ultraviolet rays can be determined only by the heart rate measurement function of the PPG sensor. In addition, the possibility of expanding the heart rate measurement function of the PPG sensor to the use of skin condition management was considered. we used an Arduino-based reflective PPG sensor to measure changes in heart rate by selecting body sites with high and low UV rays exposure. A significant value was derived through tests considering factors such as gender, UV exposure, and age. As a result, the study identified the possibility of adding ultraviolet rays and skincare items to future smart watch healthcare items and the possibility of expanding skin measurement methods. It is also possible to suggest the direction of future research.

Cholesteric Liquid Crystals as Multi-Purpose Sensor Materials

  • Lisetski, L.N.
    • Journal of Radiation Protection and Research
    • /
    • 제30권1호
    • /
    • pp.27-30
    • /
    • 2005
  • New possibilities are discussed for cholesteric liquid crystals (CLC) as sensor materials for detection of ionizing radiation, biologically active UV radiation, and the presence of hazardous vapors in atmosphere. A distinguishing property of CLC-based detectors is their 'bioequivalence', i.e., mechanisms of their response to external factors essentially imitate the corresponding mechanisms of biological tissues. Such detectors can ensure sufficiently high sensitivity to make feasible their use as alarm indicators or in biophysical studies. Specific examples ate given of sensor compositions and their response characteristics.

UV/ozone 산화처리 및 화학적 식각공정을 적용한 그래핀 Grain Boundary 평가 방법 (Evaluation Method for Graphene Grain Boundary by UV/ozone-oxidation Chemical-etching Process)

  • 강재운;박홍식
    • 센서학회지
    • /
    • 제25권4호
    • /
    • pp.275-279
    • /
    • 2016
  • Chemical vapor deposited (CVD) polycrystalline graphene is widely used for various sensor application because of its extremely large surface-to-volume ratio. The electrical properties of CVD-graphene is significantly affected by the grain size and boundaries (GGBs), but evaluation of GGB of continuous monolayer graphene is difficult. Although several evaluation methods such as tunneling electron microscopy, confocal Raman, UV/ozone-oxidation are typically used, they still have issues in evaluation efficiency and accuracy. In this paper, we suggest an improved evaluation method for precise and simple GGB evaluation which is based on UV/ozone-oxidation and chemical etching process. Using this method, we could observe clear GGBs of CVD-graphene layers grown by different process conditions and statistically evaluate average grain sizes varying from $1.69{\sim}4.43{\mu}m$. This evaluation method can be used for analyzing the correlation between the electrical properties and grain size of CVD-graphene, which is essential for the development of graphene-based sensor devices.

Inkjet Printing of Polymeric Resistance Humidity Sensor Using UV-Curable Electrolyte Inks

  • Cho, Nam-Bu;Lim, Tai-Ho;Jeon, Young-Min;Gong, Myoung-Seon
    • Macromolecular Research
    • /
    • 제16권2호
    • /
    • pp.149-154
    • /
    • 2008
  • UV-curable electrolytes inks were prepared by dissolving [2-[(methacryloyloxy)ethyl]dimethyl]propylaminium bromide (MEPAB), 1,5-[bis(2-methacryloxyethyl)dimethyl ammono]penthane dibromide (MDAPD), hexafunctional reactive oligomer (SP1013), trimethylolpropane triacrylate (TMPTA) and a photoinitiator in methanol/2-methoxyethanol. The compositions of the electrolyte inks were MEPAB/MDAPD/SP1013/TMPTA=6/24/17.2/12.8, 15/15/17.2/12.8 and 24/6/17.2/12.8. Humid-membranes were deposited on a gold electrode/alumina electrode using an ink-jet printer equipped with a UV lamp followed by immediate UV curing. The humidity-sensing characteristics including hysteresis, frequency and temperature dependence, response time and water durability were estimated.

Eu 도핑 SrAl2O4 형광체의 광 여기 전류 특성에 대한 Dy 코-도핑 효과 (Dy co-doping effect on photo-induced current properties of Eu-doped SrAl2O4 phosphor)

  • 김세기
    • 센서학회지
    • /
    • 제18권1호
    • /
    • pp.48-53
    • /
    • 2009
  • $Eu^{2+}$-doped ${SrAl_2}{O_4}$ and $Eu^{2+}$, $Dy^{3+}$ co-doped ${SrAl_2}{O_4}$ phosphors have been synthesized by conventional solid state method. Photocurrent properties of $Eu^{2+}$ doped ${SrAl_2}{O_4}$ and $Eu^{2+}$, $Dy^{3+}$ co-doped ${SrAl_2}{O_4}$ phosphors, in order to elucidate $Dy^{3+}$ co-doping effect, during and after ceasing ultraviolet-ray (UV) irradiation have been investigated. The photocurrent of $Eu^{2+}$, $Dy^{3+}$ co-doped ${SrAl_2}{O_4}$ phosphors during UV irradiation was 4-times lower than that of $Eu^{2+}$-doped ${SrAl_2}{O_4}$ during UV irradiation, and 7-times higher than that of $Eu^{2+}$-doped ${SrAl_2}{O_4}$ after ceasing UV irradiation. The photocurrent results indicated that holes of charge carriers captured in hole trapping center during the UV irradiation and liberated after-glow process, and made clear that $Dy^{3+}$ of co-dopant acted as a hole trap. The photocurrent of ${SrAl_2}{O_4}$ showed a good proportional relationship to UV intensity in the range of $1{\sim}5mW/cm^2$, and $Eu^{2+}$-doped ${SrAl_2}{O_4}$ was confirmed to be a possible UV sensor.

의료 약물주입용 미세 유량 제어 장치 (Fine Flow Controlling Device for Medicine Injection)

  • 조수찬;신보성
    • 마이크로전자및패키징학회지
    • /
    • 제28권4호
    • /
    • pp.51-55
    • /
    • 2021
  • 본 논문은 보통 병원에서 간호사가 수작업으로 진행하는 약물주입 과정을 대신할 수 있는 의료용 미세 유량 제어 장치를 소개한다. 이는 아두이노로 구현되었으며 환자의 지속적인 관리에 도움이 되고자 한다. 기본적으로 연동펌프를 통해 약물이 주입되며 RGB color sensor를 통해 배출액의 색상을 값으로 받아들이고 이 값을 바탕으로 수액백에 달린 연동펌프의 모터 속도를 조절하는 알고리즘을 아두이노 코딩을 통해 구현한다. 전체적인 시스템은 배터리를 통해 작동되며 연구실에서 355nm UV pulsed laser를 통해 제작한 LIG strain sensor의 추가를 통해 수액백으로부터 주입되는 약물의 양을 측정한다. 이렇게 제작된 미세 유량 제어 장치는 모든 과정을 수작업으로 진행해오던 병원에 곧장 사용 가능하며 간호사의 편의를 제공하고자 한다. 이 장치를 통해 한층 향상된 의료서비스를 제공할 수 있다.

UV광 측정용 아조벤젠 코팅된 FBG의 열적 효과 제거 및 파장 의존성에 대한 연구 (The Study of Thermal Effect Suppression and Wavelength Dependence of Azobenzene-coated FBG for UV Sensing Application)

  • 최동석;김현경;안태정
    • 한국광학회지
    • /
    • 제22권2호
    • /
    • pp.67-71
    • /
    • 2011
  • 본 논문에서는 ultraviolet (UV) 광의 세기를 원격으로 측정하기 위한 아조벤젠 (azobenzene) 코팅된 fiber Bragg grating (FBG)를 구현하였다. 아조벤젠 폴리머는 UV 광에 의해서 탄성이 변화하여 FBG의 코어 격자의 주기 변화를 유도하여 중심파장을 이동시킨다. 중심파장의 이동은 UV 광과 UV 이외의 파장대역의 빛에 의해서 복합적으로 발생하는데 중심파장의 이동량은 약 0.18 nm 이다. 측정의 정확성을 향상시키기 위해서 광원의 복사열에 의한 중심파장의 이동을 열차단 필터(thermal filter)를 사용하여 제거한 결과 중심파장의 이동량은 약 0.06 nm로 다소 감소하였지만 분석 결과 열에 의한 이동량이 충분히 제거된 것을 확인하였다. 또한 서로 다른 방법인 열경화법과 UV 경화법으로 각각 제작된 아조벤젠 폴리머를 이용하여 아조벤젠 코팅 FBG를 제작하였고, 각 제조법에 따른 UV센서로서의 적합성을 확인하였다. 몇 개의 밴드패스 필터(band pass filter)를 사용하여 파장에 대한 민감도를 측정한 결과, 단위 UV 세기당 중심파장의 이동량은 370nm 파장 밴드에서 가장 큰 값인 0.029로, 단파장 영역에서 반응성이 우수하다는 사실을 확인 하였다. 아조벤젠 폴리머의 흡수 스펙트럼과 아조벤젠 코팅 FBG의 파장 의존도가 서로 잘 일치하는 것을 확인하였다.

380-nm Ultraviolet Light-Emitting Diodes with InGaN/AlGaN MQW Structure

  • Bae, Sung-Bum;Kim, Sung-Bok;Kim, Dong-Churl;Nam, Eun Soo;Lim, Sung-Mook;Son, Jeong-Hwan;Jo, Yi-Sang
    • ETRI Journal
    • /
    • 제35권4호
    • /
    • pp.566-570
    • /
    • 2013
  • In this paper, we demonstrate the capabilities of 380-nm ultraviolet (UV) light-emitting diodes (LEDs) using metal organic chemical vapor deposition. The epi-structure of these LEDs consists of InGaN/AlGaN multiple quantum wells on a patterned sapphire substrate, and the devices are fabricated using a conventional LED process. The LEDs are packaged with a type of surface mount device with Al-metal. A UV LED can emit light at 383.3 nm, and its maximum output power is 118.4 mW at 350 mA.

Enhanced Adhesion and Transmittance Uniformity in Laminated Polymer-Dispersed Liquid Crystal Films

  • Yoo, Seong-Hyeon;Park, Min-Kyu;Park, Ji-Sub;Kim, Hak-Rin
    • Journal of the Optical Society of Korea
    • /
    • 제18권6호
    • /
    • pp.753-761
    • /
    • 2014
  • We propose a two-step UV irradiation procedure to fabricate polymer-dispersed liquid crystal (PDLC) films by lamination. During the first UV treatment, before lamination, the UV-curable monomers coated on one film substrate are solidified through photo-polymerization as the phase separation between the liquid crystals and the monomers. Introducing an adhesion-enhancement layer on the other plastic substrate and controlling the UV irradiation conditions ensure that UV-induced cross-linkable functional groups remain on the surfaces of the photo-polymerized layers. Thereby, the adhesion stability between the top and bottom films is much improved during a second (post-lamination) UV treatment by further UV-induced cross-linking at the interface. Because the adhesion-enhancement and PDLC layers prepared by the bar-coating process are solidified before lamination, the PDLC droplet distribution and the cell gap between the two plastic substrates remain uniform under the lamination pressure. This ensures that the voltage-controlled light transmittance is uniform across the entire sample.

UV/IR센서 결합에 의한 불꽃 영상검출의 설계 및 분석 (Design and Analysis of Flame Signal Detection with the Combination of UV/IR Sensors)

  • 강대석;김은종;문필재;신원호;강민구
    • 인터넷정보학회논문지
    • /
    • 제14권2호
    • /
    • pp.45-51
    • /
    • 2013
  • 본 논문에서는 자외선(UV, ultraviolet) 및 적외선(IR, infrared) 센서를 결합함으로서 불이 연소하면서 방출하는 빛의 파장을 활용한 영상신호를 검출하는 결합형 불꽃영상 검출시스템은 적외선 센서와 자외선 센서 기반의 신호처리 알고리즘 설계방안을 제안한다. 또한, 설계한 듀얼모드인 결합형 불꽃영상 검출시스템은 단독형 적외선 또는 자외선 센서 기반의 영상검출 알고리즘의 검출 성능결과를 비교한다.