• 제목/요약/키워드: UV Intensity

검색결과 517건 처리시간 0.023초

나노크리스탈 Quantum-dot을 적용한 남조류 독소 Microcystin 탐지 연구 (Application of Quantum-dot Nanocrystals for Cyanobacterial Toxin-Microcystin Detection)

  • 이진욱;유혜원;김인수
    • 한국물환경학회지
    • /
    • 제23권5호
    • /
    • pp.705-711
    • /
    • 2007
  • Green quantum-dot nanocrystal (QD525) with anti-microcystin monoclonal antibody was applied for detection of microcystin, a monocyclic peptide hepatotoxin, extracted from the culture of Microcystis aeruginosa. The presence of microcystin in the cell lysate was verified by HPLC analysis with UV absorbance at 238 nm. Microcystis cell extract exhibited fluorescence emission spectra, which peak was around 460 nm because of their complex organic substances. When a spherical QD525 antibody conjugates (10~20 nm in diameter) were bound to the microcystins in the Microcystis cell lysate, the fluorescence intensity of the primary peak at 525 nm diminished while the secondary emission peak at 460 nm slightly increased intensities. It is due to energy transfer from the primary (major) to the secondary (minor) peak, resulting from physical deformation of QD525 and different environmental factors. On the other hand, other cell extracts did not show any fluorescence emission change. This study is very available for detecting and monitoring the microcystin because it is one step assay without washing step and portable spectrophotometer makes on-site measurement possible. For health risk assessment of the microcystin, the reliable and rapid system to detect and quantify microcystin is seriously required.

주파수 위상 간섭계를 이용한 펨토초 레이저 펄스의 시간적 특성연구 (Temporal characterization of femtosecond laser pulses using spectral phase interferometry for direct electric-field reconstuction)

  • 강용훈;홍경한;남창희
    • 한국광학회지
    • /
    • 제12권3호
    • /
    • pp.219-224
    • /
    • 2001
  • 주파수 위상 간섭계를 이용한 전기장 재구성 방법(SPIDER)을 이용하여 Kerr 렌즈 모드록킹된 티타늄 사파이어 레이저 공진기에서 생성된 펨토초 영역의 극초단 펄스의 펄스폭과 위상을 측정하였다. 8cm 길이의 SF10 매질과 마이켈슨형의 시간지연암(arm)을사용하여 주파수 층밀림(shearing)을 구현하고 제2종 BBO결정으로 합주파수 발생을 시켜 SPIDER 장치를 구성 하였다 얻어진 층밀림 주파수 간섭 신호로부터 SPIDER 알고리즘을 이용하여 펄스의 전기장을 복원하였다 SPIDER의 정확도를 확인하기 위해 SPIDER에서 얻은 펄스로 재구성한 간섭형 자체상솬신호를 직접 측정한 간섭형 자체상관 신호와 비교하였다. SPIDER를 티타늄 사파이어 레이저 공진기에 적용하여 19fs의 펄스폭을 얻었으며 sech$^2$나 가우시안으로 가정한 간섭형 자체상관의 결과는 이보다 작은 값으로 나타나서 펨토초 레이저의 정확한 펄스폭 측정을 위해서는 펄스모양의 가정이 필요없는 SPIDER 방법이 필요함을 알 수 있었다.

  • PDF

급속 열처리 방법에 의한 Al-doped Zinc Oxide (AZO) Films의 제조 및 특성 평가 (Preparation and Evaluation of the Properties of Al-doped Zinc Oxide (AZO) Films Deposition by Rapid Thermal Annealing)

  • 김성진;최균;최세영
    • 한국전기전자재료학회논문지
    • /
    • 제25권7호
    • /
    • pp.543-551
    • /
    • 2012
  • In this study, transparent conducting Al-doped Zinc Oxide (AZO) films with a thickness of 150 nm were prepared on corning glass substrate by the RF magnetron sputtering with using a Al-doped zinc oxide (AZO), ($Al_2O_3$: 2 wt%) target at room temperature. This study investigated the effect of rapid thermal annealing temperature and oxygen ambient on structural, electrical and optical properties of Al-doped zinc oxide (AZO) thin films. The films were annealed at temperatures ranging from 400 to $700^{\circ}C$ by using Rapid thermal equipment in oxygen ambient. The effect of RTA treatment on the structural properties were studied by x-ray diffraction and atomic force microscopy. It is observed that the Al-doped zinc oxide (AZO) thin film annealed at $500^{\circ}C$ at 5 minute oxygen ambient gas reveals the strongest XRD emission intensity and narrowest full width at half maximum among the temperature studied. The enhanced UV emission from the film annealed at $500^{\circ}C$ at 5 minute oxygen ambient gas is attributed to the improved crystalline quality of Al-doped zinc oxide (AZO) thin film due to the effective relaxation of residual compressive stress and achieving maximum grain size.

Fabrication of Optical Fiber Gas Sensor with Polyaniline Clad

  • 이윤수;송갑득;주병수;이상문;최낙진;이덕동;허증수
    • 센서학회지
    • /
    • 제13권2호
    • /
    • pp.96-100
    • /
    • 2004
  • Optical fiber sensors have been used to detect small amounts of chemical species. In this work, a new thin polymer-clad fiber sensor is developed. Polyaniline is chemically synthesized and thin clad layers of the polymer are easily deposited on optical fiber by dip-coating technique. The optical property of polyaniline as a sensing material is analyzed by UV-Vis-NIR. The light source is stabilized He-Ne laser at 635 nm wavelength with 1 mW power. The light power transmitted through the optical fiber is measured with a spectrophotometer. By selecting a fixed incident angle, variation of transmitted light intensity through the optical fiber can be detected as gas molecules absorbed in the polyaniline clad layer. Among the various gases, the fabricated optical fiber sensor shows good sensitivity to $NH_{3}$ gas. The optical fiber sensors was shown more improved properties than polymer based sensors which measure conductivity changes.

생분해 과정 중 용존 유기물 특성 변화에 미치는 휴믹물질의 영향 (Effects of Humic Substances on the Changes of Dissolved Organic Matter Characteristics by Biodegradation)

  • 박민혜;이보미;이태환;허진;양희정
    • 한국물환경학회지
    • /
    • 제25권3호
    • /
    • pp.419-424
    • /
    • 2009
  • Characteristics of humic substances on the changes in dissolved organic matter (DOM) characteristics by biodegradation was investigated using three types of the artificial water samples composed of glucose and Suwannee River fulvic acid (SRFA). Some selected DOM characteristics including the specific UV absorbance (SUVA), the synchronous fluorescence spectra and the molecular weight (MW) were compared for the artificial water samples before and after 28-day microbial incubation. The changes of the DOM characteristics were minimal for SRFA during the incubation whereas they were significant for glucose. SUVA, dissolved organic carbon (DOC)-normalized fluorescence intensity, and MW values of glucose increased, suggesting that such labile organic compounds could be exclusively transformed into more humidified materials by biodegradation. For glucose-SRFA mixture, the selected DOM characteristics were greater than those estimated using the assumption that the individual changes of either glucose or SRFA are conservative for the mixture of the two materials. Our results suggest that the presence of humic substances (HS) may lead to the enhancement of the formation of refractory organic materials during biodegradation of labile compounds. Detailed analyses of size exclusion chromatography (SEC) revealed that the enhancement occurred for the DOM mixture with a MW range between 500 Da to 4000 Da.

A Study of the Diffusion and Rise of Stack Plumes at Coastal Region by Using LIDAR Observation Data

  • Yoon, Ill-Hee
    • International Union of Geodesy and Geophysics Korean Journal of Geophysical Research
    • /
    • 제26권1호
    • /
    • pp.43-58
    • /
    • 1998
  • The Kwinana Shoreline Fumigation Experiment (KSFE) took place at Fremantle, WA, Australia between January 23 and February 8, 1995. The CSIRO DAR LIDAR measured plume sections from near the Kwinana Power Station (KPS) stacks to up to about 5 km downstream. It also measured boundary layer aerosols and the structure of the boundary layer on some occasions. Both stages A and C of KPS were used as tracers at different times. The heart of the LIDAR system is a Neodymium-doped Yttrium-aluminum-garnet (Nd:YAG) laser operating at a fundamental wavelength of 1064 nm, with harmonics of 532 nm and 355 nm. For these experiments the third harmonic was used because the UV wavelength at 355 nm is eye safe beyond about 50 m. The laser fires a pulse of light 6 ns in duration (about 1.8 m long) and with an energy (at the third harmonic) of about 70 mJ. This pulse subsequently scattered and absorbed by both air molecules and particles in the atmosphere. A small fraction of the laser beam is scattered back to the LIDAR, collected by a telescope and detected by a photo-multiplier tube. The intensity of the signal as a function of time is a measure of the particle concentration as a function of distance along the line of the laser shot. The smoke plume was clearly identifiable in the scans both before and after fumigation in the thermal internal boundary layer (TIBL). Both power station plumes were detected. Over the 9 days of operation, 1,568 plumes scans (214 series) were performed. Essentially all of these will provide instantaneous plume heights and widths, and there are many periods of continuous operation over several hours when it should be possible to compile hourly average plume statistics as well. The results of four days LIDAR observations of the dispersion of smoke plume in the TIBL at a coastal site are presented for the case of stages A and C.

  • PDF

마이크로솔더링을 이용한 정전류다이오드 회로 자외선 LED 광원모듈 제작 (Fabrication Of Ultraviolet LED Light Source Module Of Current Limiting Diode Circuit By Using Flip Chip Micro Soldering)

  • 박종민;유순재;카완 안일
    • 한국전기전자재료학회논문지
    • /
    • 제29권4호
    • /
    • pp.237-240
    • /
    • 2016
  • The improvement of irradiation intensity and irradiation uniformity is essential for large area and high power UVA light source application. In this study, large number of chips bonded by micro soldering technique were driven by low current, and current limiting diodes were configured to supply constant current to parallel circuits consisting of large number of series strings. The dimension of light source module circuit board was $350{\times}90mm^2$ and 16,650 numbers of 385 nm flip chip LEDs were used with a configuration of 90 parallel and 185 series strings. The space between LEDs in parallel and series strings were maintained at 1.9 mm and 1.0 mm distance, respectively. The size of the flip chip was $750{\times}750{\mu}m^2$ were used with contact pads of $260{\times}669{\mu}m^2$ size, and SAC (96.5 Sn/3.0 Ag/0.5 Cu) solder was used for flip chip bonding. The fabricated light source module with 7.5 m A supply current showed temperature rise of $66^{\circ}C$, whereas irradiation was measured to be $300mW/cm^2$. Inaddition, 0.23% variation of the constant current in each series string was demonstrated.

신개념 기계식 선박평형수 처리장치의 디스크 형상에 따른 유동특성에 관한 수치해석 연구 (Numerical study on fluid characteristics due to disc shape in a novel mechanical ballast water treatment system)

  • 손상호;김영철;최경관
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제39권1호
    • /
    • pp.19-27
    • /
    • 2015
  • 최근에 국제해사기구(IMO)에서 선박 평형수 처리장치(Ballast water treatment system, BWTS)와 관련된 국제 규정을 강화함에 따라 이에 대응할 수 있는 BWTS 기술개발의 중요성이 대두되고 있다. 지금까지는 세계 각국에서 선박 평형수 처리기술을 처리방식에 따라 크게 물리적 방식(막분리, 원심분리, 자외선 등)과 화학적 처리방식(염소처리, 오존처리, 화확약품 등)으로 개발하여 왔으나, 기존의 기술 방식들은 추가적인 구동전력, 낮은 생산성, 잔류처리 문제 등으로 기술적인 보완이나 대안이 요구되고 있다. 본 연구에서는 기존과는 다른 새로운 방식의 기계식 방식 평형수 처리장치의 설계를 위한 유동해석 연구이다. 고속 회전하는 몇 가지 디스크 형상에 따라 유동에서 발생하는 여러 가지 유동특성을 전산유체해석(CFD)를 통하여 분석하였다. 평판형 및 계단형 형상에서는 반경을 따라서 국부적으로 공동현상이 발생가능하며, 원주형에서는 전단응력 강도를 높일 수 있었다.

유채단백질의 Proteolysis에 의한 기능성 변화 (Functionality Changes of Rapeseed Protein upon Proteolysis)

  • 김충희;김효선;이장순
    • 한국식품영양과학회지
    • /
    • 제21권5호
    • /
    • pp.519-524
    • /
    • 1992
  • 탈지유채박(Brassica napus var. Youngsan)으로부터 추출, 정제하여 얻어진 유채단백질을 가수분해하여 가수분해물의 이화학적 및 기능적 특성을 조사하였다. 가수분해물의 UN 및 고유형광 스펙트럼은 각각 274nm, 360nm에서 최대치를 나타내었다. 황색도는 약간 감소한 반면 표면 소수성은 약 4배 감소하였다. SDS-PAGE 분석 결과 상당부분이 1.4~$1.2{\times}10^4$ dalton의 분자량을 가진 band로 나타났으며, pH별 용해도는 산성부근에서 10~15% 정도 증가하였고, 수분 및 유흡수성, 거품 팽창성, 에멀젼 안정성은 증가한 반면 절대 점도, 열 및 칼슘 응고성, 거품 안정성, 에멀젼 활성지수는 감소하였다.

  • PDF

Emission Plasma Spectroscopy of High-pressure Microdischarges

  • 이병준;주영도;김승환;하태균;공형섭;박용정;박종도;남상훈
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2014년도 제46회 동계 정기학술대회 초록집
    • /
    • pp.253.2-253.2
    • /
    • 2014
  • Micro hollow cathode discharges (MHCDs) are high-pressure, non-equilibrium discharges. Those MHCDs are useful to produce an excimer radiation. A major advantage of excimer sources is their high internal efficiency which may reach values up to 40% when operated under optimum conditions. To produce strong excimer radiation, the optimisation of the discharge conditions however needs a detailed knowledge of the properties of the discharge plasma itself. The electron density and temperature influence the excitation as well as plasma chemistry reactions and the gas temperature plays a major role as a significant energy loss process limiting efficiency of excimer radiation. Most of the recent spectroscopic investigations are focusing on the ultraviolet or vacuum ultraviolet range for direct detection of the excimer. In our experiments we have concentrated on investigating the micro hollow cathodes from the near UV to the near infrared (300~850 nm) to measure the basic plasma parameters using standard plasma diagnostic techniques such as stark broadening for electron density and the relative line intensity method for electron temperature. Finally, the neutral gas temperature was measured by means of the vibrational rotational structures of the second positive system of nitrogen.

  • PDF