• 제목/요약/키워드: UV/ozone

검색결과 255건 처리시간 0.026초

Characteristics of Environmental Solar Ultraviolet Irradiance

  • Sasaki, Masako;Oyanagi, Takehiko;Takeshita, Shu
    • Journal of Photoscience
    • /
    • 제9권2호
    • /
    • pp.154-157
    • /
    • 2002
  • Direct, continuous, and accurate measurements of solar ultraviolet irradiance (290-400 nm: UVR) have been carried out since 1990, by using both band-spectral ultraviolet-B (290-320 nm: UV-B) and ultraviolet-A (320-400 nm: UV-A) radiometers at Tokai University in Hiratsuka, Japan (35$^{\circ}$N, 139$^{\circ}$E). From our observations, the following findings are provided: 1) an increasing trend in solar UV -B from Oct. 1990 to Sept. 2000; 2) a regional comparison of solar UVR in Japan; 3) the distinct characteristics of UV-B and UV-A irradiance, such as diffuse property, daily and seasonal variation; and 4) human body protection against solar UVR. An increasing 10-year trend in global solar UV - B in Hiratsuka corresponded to a decrease in the total ozone amount measured at Tsukuba (36$^{\circ}$N, 140$^{\circ}$E), giving supportive evidence for a direct link between these two parameters. Furthermore, a strong correlation was found between solar UV-B and total ozone amount from results of UVR measurements at four Tokai University monitoring stations dispersed throughout Japan. Additional results revealed different diffuse properties in global solar UV and in global solar total (300-3000 nm: Total) irradiances. For example, in the global UVR, the diffuse component was dominant: about 80 % independent of weather, with more than 60 % of global UV-B, and more than 50% of global UV-A with even a cloudless clear sky. On the other hand, the portion of the diffuse in the global total irradiance was very low, less than 10 % on a cloudless clear day. Daily and seasonal variations of UV -B and UV -A irradiances were found to be quite different, because of the marked dependence of UV -B irradiance on the atmospheric ozone amount. Moreover, UV -B irradiance showed large daily and seasonal variations: the ratio between maximum and minimum irradiances was more than 5. In contrast, the variation in UV-A was small: the ratio between maximum and minimum was less than 2. Three important facts are proposed concerning solar UVR protection of the human body: 1) the personal minimal erythema dose (MED); 2) gender based difference in MED values; and 3) proper colors for UVR protective clothing.

  • PDF

오존층 파괴에 의한 자외선 증가가 식물에 미치는 영향 (Effects of Enhanced Ultraviolet-B Radiation on Plants)

  • Hak Yoon Kim;Moon Soo Cho
    • 생물환경조절학회지
    • /
    • 제10권3호
    • /
    • pp.197-206
    • /
    • 2001
  • 오존층 파괴에 의해 지표면에 도달하는 자외선, 특히 UV-B(ultraviolet-B radiation, 280∼320nm)의 방사량이 증가하고 있다. UV-B는 유전자의 직접적인 손상, 호르몬 분해, 광합성 억제 등 생리·생화학적 대사기구에 영향을 미쳐 육상 생태계와 안정된 식량 확보에 큰 위협이 되고 있다. 그러나 식물은 UV-B에 대한 방어 기능을 갖고 있으며 형태적 적응, 광 회복 기능, UV-흡수물질의 생합성 촉진 등을 통해 UV-B로부터 생체를 보호한다.

  • PDF

Adhesion Reliability Enhancement of Silicon/Epoxy/Polyimide Interfaces for Flexible Electronics

  • Kim, Sanwi;Kim, Taek-Soo
    • 마이크로전자및패키징학회지
    • /
    • 제19권3호
    • /
    • pp.63-69
    • /
    • 2012
  • Adhesion and mechanical reliability of silicon/epoxy/polyimide interfaces are critical issues for flexible electronics. Bonds between these interfaces are mainly hydrogen bonds, so their adhesion is weaker than cohesive fracture toughness and vulnerable to moisture. In order to enhance adhesion and suppress moisture-assisted debonding, UV/Ozone treatment and innovative sol-gel derived hybrid layers were applied to silicon/epoxy/polyimide interfaces. The fracture energy and subcritical crack growth rate were measured by using a double cantilever beam (DCB) fracture mechanics test. Results showed that UV/Ozone treatment increased the adhesion, but was not effective for improving reliability against humidity. However, by applying sol-gel derived hybrid layers, adhesion increase as well as suppresion of moisture-assisted cracking were achieved.

Electrical Properties of a CuPc Field-Effect Transistor Using a UV/Ozone Treated and Untreated Substrate

  • Lee, Ho-Shik;Cheon, Min-Woo;Park, Yong-Pil
    • Transactions on Electrical and Electronic Materials
    • /
    • 제12권1호
    • /
    • pp.40-42
    • /
    • 2011
  • An organic field-effect transistor (OFET) was fabricated using a copper phthalocyanine (CuPc) as the active layer on the silicon substrate. The CuPc FET device was configured as a top-contact type. The substrate temperature was room temperature. The CuPc thickness was 40 nm, and the channel length and channel width were 100 ${\mu}m$ 3 mm, respectively. Typical current-voltage (I-V) characteristics of the CuPc FET were observed and subsequently compared to the UV/ozone treatment on substrate surface.

Ozone Measurments in the Stratosphere from KSR420S-1 and -2 : the Preliminary Results

  • Lee, Ki-Yiung-;Lee, Dong-Hun-;Kim, Jhoon-;Park, Chang-joon-
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 1993년도 한국우주과학회보 제2권2호
    • /
    • pp.11-11
    • /
    • 1993
  • The Korean sounding rockets(KSR) 1, 2 equigped with the UV optical detectors have been launched at An-heung, Chungchongnam-do, of June 4 and September 1, 1993,respectively. The UV detector is used to measure the attenuation of solar UV radiation for various frequency bards in the stratospgere. We obtained the profile of the ozone number density within the altitulde of 15 - 30 km by applying the Beer-Lambert law. It is found that the maHimum of the ozone distribution occurs near 2sht which is quite consistent with the mean value in the mid-latituderegions. We will also compare our results froiu KSR 1,2 with the other observational data from the Dobson speceo meter at Yonsei Univ. and the LIDAa which were performed simultaneously with the sounding rocket experiments.

  • PDF

ZnO를 사용한 MOS 커패시터의 제작 조건에 따른 특성 변화 (Property Variations of ZnO-based MOS Capacitor with Preparation Conditions)

  • 남형진
    • 반도체디스플레이기술학회지
    • /
    • 제9권3호
    • /
    • pp.75-78
    • /
    • 2010
  • In this study we investigated the electrical properties of ZnO-based MOS capacitor with $HfO_2$ as the gate dielectric. MIM capacitor, which uses either $HfO_2$ or $Al_2O_3$ as the dielectric layer, is also studied to understand the dependency of the dielectrics on the preparation conditions. It was found that thinner $HfO_2$ films yield better electrical properties, namely lower leakage current and higher breakdown electric field. These properties were observed to deteriorate when subsequently annealed. Capacitance in the depletion region of MOS capacitor was found to increase with UV ozone treatment time up to 60min. However, when the treatment time was extended to 120min, the trend is reversed. The 'threshold voltage' was also observed to positively shift with UV ozone treatment time up to 60min. The shift apparently saturated for longer treatment.

제주도 매립장 침출수 중 유기물의 효율적 처리를 위한 광촉매 분해 반응의 응용 (Application of Photocatalytic Degradation for Efficient Treatment of Organic Matter in Landfill Leachate in Jeju Island)

  • 이창한;이택관;조은일;감상규
    • 한국환경과학회지
    • /
    • 제31권8호
    • /
    • pp.677-689
    • /
    • 2022
  • In order to photocatalytically treat organic matter (CODCr) and chromaticity effectively, chemical coagulation and sedimentation processes were employed as a pretreatment of the leachate produced from landfill in Jeju Island. This was performed using FeCl3·6H2O as a coagulant. For the treated leachate, UV/TiO2 and UV/TiO2/H2O2 systems were investigated, using 4 types of UV lamps, including an ozone lamp (24 W), TiO2 as a photocatalyst, and/or H2O2 as an initiator or inhibitor for photocatalytic degradation. In the chemical coagulation and sedimentation process using FeCl3·6H2O, optimum removal was achieved with an initial pH of 6, and a coagulant dosage of 2.0 g/L, culminating in the removal of 40% CODCr and 81% chromaticity. For the UV/TiO2 system utilizing an ozone lamp and 3 g/L of TiO2, the optimum condition was obtained at pH 5. However, the treated CODCr and chromaticity did not meet the emission standards (CODCr: 400 mg/L, chromaticity: 200 degrees) in a clean area. However, for a UV/TiO2/H2O2 system using 1.54 g/L of H2O2 in addition to the above optimum UV/TiO2 system, the results were 395 mg/L and 160 degrees, respectively, which were within the emission standard limits. The effect of the UV lamp on the removal of CODCr, and chromaticity of the leachate decreased in the order of ozone (24 W) lamp > 254 nm (24 W) lamp > ozone (14 W) lamp > 254 nm (14 W) lamp. Only CODCr and chromaticity treated with the ozone (24 W) lamp met the emission standards.

성층권 에어로졸에 의한 지표면 UV-B 복사량 변동 (The Changes of UV-B Radiation at the Surface due to Stratospheric Aerosols)

  • Jai-Ho Oh;Joon-Hee Jung;Jeong-Woo Kim
    • International Union of Geodesy and Geophysics Korean Journal of Geophysical Research
    • /
    • 제21권1호
    • /
    • pp.31-46
    • /
    • 1993
  • 대기 가열율과 복사속의 연직 분포를 계산하기 위하여 two-stream/delta-Eddington 근사법을 이용한 복사전달모형이 개발되었다. 이 모형의 결과를 ICRCCM의 결과와 비교하므로써 모형의 완성도를 평가하였다. 이 모형은 정확성 뿐 아니라 경제적인 면에서도 태양복사를 계산하는데 적합한 것으로 증명되었다. 대기 꼭대기에서의 복사속과 지표에서의 복사속 간의 관계를 비교하므로써 자외선 B 영역(UV-B; 280-320nm)의 특징들이 검토되었다. 이 영역에서는 강한 오존 흡수가 있어 UV-B의 관계가 2차 함수로 나타난다. 또한, 성층권 오존 감소와 화산 폭발로 기인한 성층권 에어로졸 안개가 UV-B 복사에 미치는 영향을 다양한 태양의 천정각에서 조사했다. 태양의 천정각이 증가함에 따라 지표 UV-B도 증가하였다. 성층권 에어로졸은 후방 산란을 통해 행성 반사도를 증가시켰다. 행성 반사도는 에어로졸 효과로 인해 태양의 천정각이 증가함에 따라 증가한다. 그러나, 행성 반사도의 변화가 태양의 천정각 변화에 따라 민감하게 나타나지는 않는다. 이것은 태양의 천정각이 클 때 에어로졸의 산란 효과가 상대적으로 긴 복사 경로에서 포화되었기 때문일 것이다. 끝으로, 화산 폭발에서 비롯된 성층권 에어로졸이 지표 UV-B 복사 강도에 미치는 지역적 영향이 추정되었다. 고위도에서는 에어로졸의 광자 포획(photon trap)이나 일몰 효과로 복사 강도가 증가하는 반면 저위도에서는 감소한다. 고위도에서 에어로졸의 산란과 오존 흡수는 지표 UV-B 복사의 최대 증가는 봄 기간 중에 양 반구 모두 중위도에서 나타난다.

  • PDF

$오존/UV/H_2O_2$를 이용한 몰리브덴(Mo) 용해 반응에 따른 청정기술 개발에 관한 연구 (A clean technology development using the molybdenum dissolution reaction with hydrogen peroxide/UV/Ozone)

  • 김재우;홍종순;신대윤
    • 환경위생공학
    • /
    • 제14권4호
    • /
    • pp.143-149
    • /
    • 1999
  • In the tungsten industry as light source material, tungsten filament which used as light source material could form after molybdenumwire which used as the center supporter for coil shape tungsten wire was removed. This process uses hydrogen peroxide, Ozone and UV(Ultraviolet)Lamp, for the quantity of hydrogen peroxide decrease. The results were as follows : 1. An incandescent electric Lamp type : FL(FL-20) type : A standard of commodity (P.W.: $19{\pm}1.0mg$, $C.R:4.5{\pm}0.3{\Omega}$) 1) Only hydrogen peroxide treated ; Reaction Time : 65Min., P.W.: 18.60mg, $C.R.:4.60{\Omega}$ 2) Ozone/Ultraviolet/70% of hydrogen peroxide; Reaction Time : 64Min., P.W.: 18.61mg, C.R.: $4.61{\Omega}$ 2. A Fluorescent Lamp Type : GLS(GLS-40) Type : A standard of commodity(P.W.: $11.8{\pm}0.2mg$$65{\pm}1.5{\Omega}$) 1) Only hydrogen peroxide treated ; Reaction Time: 72Min, P.W.:11.88mg, C.R.: $65.62\Omega$ 2) Ozone/Ultraviolet/70% of hydrogen peroxide;Reaction Time:71Min., P.W.:11.88mg, C.R.: $65.63\Omega$

  • PDF

DOF 공정에 의한 정수처리 효과 (Effect of Drinking Water Treatment by DOF(Dissolved Ozone Flotation) System)

  • 이병호;송원철
    • 대한환경공학회지
    • /
    • 제30권7호
    • /
    • pp.743-750
    • /
    • 2008
  • 본 연구에서는 용존오존부상법(Dissolved Ozone Flotation; DOF)을 이용한 정수처리 효과를 파악하기 위하여 적정 오존 주입 농도와 오존 주입 농도별 처리 특성에 대해서 연구하였으며, 또한 용존공기부상법(Dissolved Air Flotation; DAF) 및 중력식 침전법(Conventional Gravity Sedimentation; CGS)과 DOF의 처리 성능을 비교하였다. 최적 오존 주입 농도를 산정하기 위한 실험에서 최적 오존 주입농도는 2.7 mg/L로 나타났으며, 오존 주입 농도가 증가할수록 탁도 및 KMnO$_4$ 소모량, UV$_{254}$ 흡수도, TOC 등과 같은 제거효율이 낮아지는 것으로 나타났다. DOF와 DAF, CGS의 처리성능을 비교한 결과 오존 주입 농도 2.7 mg/L로 운전한 DOF시스템의 탁도 제거효율은 88.9%, 유기물질 항목의 경우 KMnO$_4$ 소모량은 62.9%, TOC 47%, 그리고 UV$_{254}$ 흡수도 77.3% 그리고 THMFP 제거율의 경우 51.6%로 다른 두 공정보다 높거나 비슷하게 나타났다. 따라서 응집 부상 공정과 오존 산화 공정이 하나의 반응기에서 일어나는 DOF 시스템은 정수처리시설의 소유부지 감소와 기존 CGS 시스템에서 처리가 어려운 조류 및 용존성 유기물질의 제거를 통해 소독부산물의 생성을 감소시킴으로 향후 고도정수처리시스템으로 적용 가능성이 충분한 것으로 판단된다.