• Title/Summary/Keyword: UPS systems

Search Result 163, Processing Time 0.025 seconds

RING E3 ligases: key regulatory elements are involved in abiotic stress responses in plants

  • Cho, Seok Keun;Ryu, Moon Young;Kim, Jong Hum;Hong, Jeong Soo;Oh, Tae Rin;Kim, Woo Taek;Yang, Seong Wook
    • BMB Reports
    • /
    • 제50권8호
    • /
    • pp.393-400
    • /
    • 2017
  • Plants are constantly exposed to a variety of abiotic stresses, such as drought, heat, cold, flood, and salinity. To survive under such unfavorable conditions, plants have evolutionarily developed their own resistant-mechanisms. For several decades, many studies have clarified specific stress response pathways of plants through various molecular and genetic studies. In particular, it was recently discovered that ubiquitin proteasome system (UPS), a regulatory mechanism for protein turn over, is greatly involved in the stress responsive pathways. In the UPS, many E3 ligases play key roles in recognizing and tethering poly-ubiquitins on target proteins for subsequent degradation by the 26S proteasome. Here we discuss the roles of RING ligases that have been defined in related to abiotic stress responses in plants.

Performance Analysis of Free-Style Writing and Drawing using Ultrasonic Position System

  • Shin, Low-Kok;Park, Soo-Hong
    • Journal of information and communication convergence engineering
    • /
    • 제6권1호
    • /
    • pp.6-9
    • /
    • 2008
  • In future domestic context aware applications the location of mobile devices is often required. Ultrasonic technology enables high resolution indoor position measurements. A disadvantage of state-of-art ultrasonic systems is that several base stations are required to estimate 3D position. This study aims to evaluate the efficiency and effectiveness of using UPS as a 3D free-hand writing or drawing tool. The processes include the design and testing of UPS as an efficient 3D free-hand writing or drawing tool in the air. The paper will further explain the system architecture of the UPS and how to use GPS as 3D free-hand writing or drawing tool. The efficiency and effectiveness of the system was confirmed by a computer software simulation. The software will further display the result of drawing or writing from the user by graphics. As a result, it is possible to implement UPS as a 3D free-hand writing or drawing tool in the air.

연산시간지연 및 민감성을 고려한 UPS 인버터용 2차 데드비트 제어기 (2nd Order Deadbeat Controller Considering Calculation Time Delay and Sensitivity for UPS Inverter)

  • 김병진;최재호
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제50권4호
    • /
    • pp.170-178
    • /
    • 2001
  • Deadbeat technique has been proposed as a digital controller for an UPS inverter to achieve the fast, response to a load variation and to conserve a very low THD under a nonlinear load condition. This scheme contains a fatal drawback, sensitivity against parameter variation and calculation time delay. This paper proposes a second order deadbeat controller, which fundamentally solves the calculation time delay problem and certainly guarantees the robustness of the parameter's variation. RLP(Repetitive Load Predictor) which predicts the load current ahead of two sampling time and FVR(Fundamental Voltage Regulator) which eliminates the fundamental errors of the output voltage are also proposed for the second order deadbeat controller to apply to UPS inverter systems. These are shown theoretically and practically through simulation and experiment.

  • PDF

A Study on a 3D Free-Hand using Ultrasonic Position System

  • Shin Low-Kok;Park Soo-Hong
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2006년도 춘계종합학술대회
    • /
    • pp.451-454
    • /
    • 2006
  • Ultrasonic Positioning System (UPS) is an absolute positioning system using ultrasonic waves and has better performance in low price than the other absolute positioning systems. UPS can be further used as pseudo-satellites in the place where GPS is not available. This study aims to evaluate the efficiency and effectiveness of using UPS as a 3D free-hand writing or drawing tool. The process includes the design and testing of VPS as an efficient 3D free-hand writing or drawing tool in the air. The paper will further explain the system architecture of the UPS and how to use GPS as 3D free-hand writing or drawing tool. The efficiency and effectiveness of the system was confirmed by a computer software simulation. The software will further display the result of drawing or writing from the user by graphics. As a result, it is possible to implement UPS as a 3D free-hand writing or drawing tool in the air.

  • PDF

The Effect of Satisfaction of Entrepreneurship Education on Successful Entrepreneurship

  • Jun-Young Lee;Sung-Ho Bang;Ki-Hwan Ryu
    • International Journal of Advanced Culture Technology
    • /
    • 제12권1호
    • /
    • pp.276-280
    • /
    • 2024
  • Recently, many policies and fairs have been made in relation to start-ups. In addition, various start-up education for prospective start-ups is being conducted in various ways. Therefore, these days, the number of prospective start-ups who receive such information and start-up education is increasing. Nevertheless, more and more start-ups are still unsuccessful and close their businesses within months or years. In particular, start-ups who continue to maintain their start-ups also see the unfortunate reality of start-ups that find other jobs in various support systems and related policies and relationships that they cannot quit even if they want to. In this study, based on previous studies, factors for satisfaction with entrepreneurship education will be set and a questionnaire will be conducted for prospective entrepreneurs who have completed education at a startup education center in Seoul. The survey results are intended to verify their reliability and validity through empirical analysis. The SPSS statistical package will be used for analysis, and a total of 200 copies of the questionnaire will be distributed and collected. In this study, it was confirmed that the higher the satisfaction with entrepreneurship education, the better the successful entrepreneurship. In addition, I think that further developing various policies or detailed curriculums for entrepreneurship education will be of great help to prospective entrepreneurs taking entrepreneurship education.

비정상 과도상태에서의 해군 전투체계 UPS 개선 (Improvement of Naval Combat System UPS under Abnormal Transients)

  • 김성후;최한고
    • 융합신호처리학회논문지
    • /
    • 제19권3호
    • /
    • pp.97-103
    • /
    • 2018
  • 본 논문에서는 비정상적인 과도상태에서의 개선된 해상 전투체계 UPS(Uninterruptable Power Supply) 시스템을 다룬다. 기존에는 일시적인 과전압 및 과전류에 대응하기 위하여 서미스터와 바리스터 소자를 사용하고 있지만 시스템 운용 중에 발생하는 비정상 과도전압에는 취약하므로 UPS가 비가용 상태로 되는 경우가 빈번히 발생하였다. 이를 극복하고 UPS 시스템을 보호하기 위하여 본 논문에서는 초기 입력전원 및 운용 중에 발생되는 비정상 과도전압을 감지한 입력 전원 차단회로, 전원제어 시퀀스 개선, 그리고 인버터 및 CPU 오동작 방지 방법 등을 제안한다. 제안된 방법으로 UPS 구현된 시스템은 Programmable AC/DC 발생기를 이용하여 입력전원 가변 시험을 통하여 시뮬레이션을 수행하였으며, 최종적으로 해상 전투체계의 다기능콘솔에 장착하여 현장시험을 통하여 신뢰성과 안정성을 검증하였다.

USP의 신뢰성 향상을 위한 독립제어 고속절환장치 (Isolation Control High Speed Transfer Switch for Upgrade Reliability of Uninterruptible Power Supply)

  • 정현철;현동석
    • 전력전자학회논문지
    • /
    • 제13권4호
    • /
    • pp.278-286
    • /
    • 2008
  • 본 논문은 대용량 더블컨버젼 방식 $30^{\sim}500[KVA]$ 무정전전원공급장치 UPS(Uninterruptible Power Supply)의 고장발생유형과 출력정지현상의 원인을 살펴보고, 부하 측면에서 전원공급의 신뢰성을 높일 수 있는 고장 검출방식을 제안한다. 인버터 출력의 전원품질을 검출하여 이상으로 판단 시 바이패스 시키는 방식의 기존 UPS 제어방식의 경우, 만일 내부(전력변환소자, 컨트롤러, CPU)소손이 발생되는 경우에는 부하전원 공급이 중단되는 현상이 발생되었고 이를 실험파형과 장비 운용결과를 통하여 증명하였다. 본 논문은 이러한 사고의 경우에도 출력전원의 공급에는 문제가 없도록 하기 위하여 기존 UPS의 제어시스템과는 별도로 독립적으로 고장검출장치, 바이패스 제어장치, 3중전원공급장치를 구축한 상태에서, 고장검출위치를 최종출력스위치 전단으로 변경하고, 고장판단 기준값을 기존 UPS제어시스템과 충돌이 없도록 변경하고, 사고확산을 차단할 수 있는 장치를 하였다. 이 시스템을 통신전원공급용 UPS 242대에 적용한 결과 2006년 이후 2년간 서비스장애가 발생되지 않았다.

3상 UPS용 3레벨 인버터의 시지연 보상기 설계 (Design of Time Delay Compensator of Three-Level Inverter for Three-Phase UPS Systems)

  • 이진우;임승범;홍순찬
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2011년도 추계학술대회
    • /
    • pp.63-64
    • /
    • 2011
  • The inevitable calculation time delay of digital controller especially degrades the voltage control performance of three-phase UPS systems. This paper proposes time delay compensators based on the Smith-predictor for both voltage and current controllers of three-level NPC inverters. The PSIM-based simulation results show that the proposed controller with delay compensator gives improved voltage control performance with respect to time delay.

  • PDF

RECENT DEVELOPMENT OF DC-TO-AC CONVERTERS FOR SMALL UPS SYSTEMS

  • Harada, Koosuke;Sakamoto, Hiroshi;Shoyama, Masahito
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1987년도 정기총회 및 창립40주년기념 학술대회 학회본부
    • /
    • pp.21-24
    • /
    • 1987
  • A novel type of the sinusoidal dc-to-ac converter is presented, where a pair of switches is placed in each side of the primary and the secondary of the isolation transformer. This converter is controlled by the phase difference between the two pairs of switches. As a result, the transformer is miniaturized by making the switching frequency high and the reactive energy can be easily recovered to the dc-source. This converter is especially suitable for small UPS systems.

  • PDF

A Study on a Single-Phase Module UPS using a Three-Arm Converter/Inverter

  • Koo, Tae-Geun;Byun, Young-Bok;Joe, Ki-Yeon;Kim, Dong-Hee;Kim, Chul-U
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • 제3B권1호
    • /
    • pp.44-51
    • /
    • 2003
  • The module UPS can flexibly implement expansion of power system capacities. Further-more, it can be used to build up the parallel redundant system to improve the reliability of power system operation. To realize the module UPS, load sharing without interconnection among parallel connecting modules as well as a small scale and lightweight topology is necessary. In this paper, the three-arm converter/inverter is compared with the general full-bridge and half-bridge topology from a practical point of view and chosen as the module UPS topology. The switching control approaches based on a pulse width modulation of the converter and inverter of the system are presented independently. The frequency and voltage droop method is applied to parallel operation control to achieve load sharing. Two prototype 3㎸A modules are designed and implemented to confirm the effectiveness of the pro-posed approaches. Experimental results show that the three-arm UPS system has a high power factor, a low distortion of output voltage and input current, and good load sharing characteristics.