• Title/Summary/Keyword: U-tube

Search Result 387, Processing Time 0.024 seconds

Analysis and Improvement of Experiments for Electrolysis of an Aqueous CuCl2 Solution in High School Science Textbooks (고등학교 과학 교과서에 제시된 염화구리(II) 수용액의 전기분해 실험의 분석 및 개선)

  • Park, Guk-Tae;Jo, Yeong-Ja;Lee, Ji-Yeong;Park, Gwang-Seo
    • Journal of the Korean Chemical Society
    • /
    • v.50 no.4
    • /
    • pp.328-337
    • /
    • 2006
  • purpose of this study was to find out problems in experiments for electrolysis of an aqueous CuCl2 solution in high school science textbooks and to suggest an improved experiment considering students' capability of experimenting and laboratory safety in high schools. For this study, the experiments for electrolysis of an aqueous CuCl2 solution presented in 11 high school science textbooks were classified by their experimental methods. After high school chemistry teachers performed the experiments as presented in the high school science textbooks, an analysis was performed on problems of the experiments, and an improved experiment was devised. According to the results of this study, in the experiments for electrolysis of an aqueous CuCl2 solution using a U type tube and a U type tube with branch, reaction velocity of the electrolysis was slow, therefore, a side reaction was generated. In the experiment using a beaker, reaction of each electrode could not be observed separately. And in the experiment using an electrolysis instrument, it was difficult to identify property of the reaction product. In the improved experiment using a reaction vessel of ㅂshape, reaction velocity of the electrolysis was fast, reaction of each electrode could be observed separately, and the side reaction decreased. From these results, it was suggested that the improved experiment would help high school students understand scientific conception regarding electrolysis.

Evaluation of Performance of Grouts and Pipe Sections for Closed-loop Vertical Ground Heat Exchanger by In-situ Thermal Response Test (현장 열응답 시험을 통한 수직 밀폐형 지중열교환기용 그라우트와 열교환 파이프 단면의 성능 평가)

  • Lee, Chul-Ho;Park, Moon-Seo;Min, Sun-Hong;Choi, Hang-Seok;Sohn, Byong-Hu
    • Journal of the Korean Geotechnical Society
    • /
    • v.26 no.7
    • /
    • pp.93-106
    • /
    • 2010
  • In performing a series of in-situ thermal response tests, the effective thermal conductivities of six vertical closed-loop ground heat exchangers were experimentally evaluated and compared one another, which were constructed in a test bed in Wonju. To compare thermal efficiency of the ground heat exchangers in field, the six boreholes were constructed with different construction conditions: grouting materials (cement vs. bentonite), different additives (silica sand vs. graphite) and the shape of pipe-sections (general U-loop type vs. 3 pipe-type). From the test results, it can be concluded that cement grouting has a higher effective thermal conductivity than bentonite grouting, and the efficiency of graphite better performs than silica sand as a thermally-enhancing addictive. In addition, a new 3 pipe-type heat exchanger provides less thermal interference between the inlet and outlet pipe than the conventional U-loop type heat exchanger, which results in superior thermal performance. Based on the results from the in-situ thermal response tests, a series of economic analyses have been made to show the applicability of the new addictives and 3 pipe-type heat exchanger.

Detection Characteristics for the Ultra Lean NOx Gas Concentration Using the MWCNT Gas Sensor Structured with MOS-FET (MOS-FET 구조의 MWCNT 가스센서를 이용한 초희박 NOx 가스 검출 특성)

  • Kim, Hyun-Soo;Lee, Seung-Hun;Jang, Kyung-Uk
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.26 no.9
    • /
    • pp.707-711
    • /
    • 2013
  • Carbon nanotubes(CNT) has strength and chemical stability, greatly conductivity characteristics. In particular, MWCNT (multi-walled carbon nanotubes) show rapidly resistance sensitive for changes in the ambient gas, and therefore they are ideal materials to gas sensor. So, we fabricated NOx gas sensors structured MOS-FET using MWCNT (multi-walled carbon nanotubes) material. We investigate the change resistance of NOx gas sensors based on MOS-FET with ultra lean NOx gas concentrations absorption. And NOx gas sensors show sensitivity on the change of gate-source voltage ($V_{gs}=0[V]$ or $V_{gs}=3.5[V]$). The gas sensors show the increase of sensitivity with increasing the temperature (largest value at $40^{\circ}C$). On the other hand, the sensitivity of sensors decreased with increasing of NOx gas concentration. In addition, We obtained the adsorption energy($U_a$), $U_a$ = 0.06714[eV] at the NOx gas concentration of 8[ppm], $U_a$ = 0.06769[eV] at 16[ppm], $U_a$ = 0.06847[eV] at 24[ppm] and $U_a$ = 0.06842[eV] at 32[ppm], of NOx gas molecules concentration on the MWCNT gas sensors surface with using the Arrhenius plots. As a result, the saturation phenomena is occurred by NOx gas injection of concentration for 32[ppm].

Characteristics of Radon Variability in Soils at Busan Area (부산광역시 일대의 토양 내 라돈 농도 변화 특성)

  • Kim, Jin-Seop;Kim, Sun-Woong;Lee, Hyo-Min;Choi, Jeong-Yun;Moon, Ki-Hoon
    • Economic and Environmental Geology
    • /
    • v.45 no.3
    • /
    • pp.277-294
    • /
    • 2012
  • The characteristics of temporal spacial radon variation in soil according to parent rock type and affecting factors were studied in Busan, Korea. The concentration of $^{222}Rn$ in soils and their parent elements ($^{226}Ra$,$^{228}Ra$, U and Th) in rocks and soils were measured at 24 sites in Busan area. The distribution and transportation behavior of these parent elements were analyzed and their correlations to radon concentration in soil were determined. Topographic effects were also evaluated. Two in-situ radon measurement (soil probe and buried tube) methods were applied to measure radon concentration in soil and their accuracies were evaluated. The spatial variation of radon in soil generally reflected U concentration in the parent rock. Average radon concentrations were higher in plutonic rocks than in volcanic rocks and were decreased in the order of felsic>intermediate>mafic rock. However, the radon concentrations were significantly varied in soils developed from same parent rocks due to the disequilibrium of U and $^{226}Ra$ between rock and soil. As results, the correlation of these element concentrations between rocks and soils was very low and radon concentrations in soils had highly co-related to the concentrations of these elements in soils. Th and $^{228}Ra$ show complex enrichment characteristics, differing significantly with U, in soils developed from same parent rock because the geochemical behavior of these elements during weathering and soil developing process was different with U. The radon concentrations in the same depth of soil in slope area were also different according to positions. The radon concentrations in soils developed from same parent rocks (19 sites at Pusan National University) varied 6.8~29.8Bq/L range because of small scale topographic variation. The opposite seasonal variation pattern of radon were observed according to soil properties. It was determined that buried tube method is more accurate method than soil probe method and was very advantageous application for the analysis for the characteristics of temporal spacial radon variation in soil.

An Experimental Study on the Influential Factors of Flow Measurement with Coriolis Mass Flowmeter (코리올리스 질량유량계의 유량측정에 영향을 미치는 인자에 관한 실험적 연구)

  • Lim, Ki-Won;Lee, Woan-Kyu
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.27 no.12
    • /
    • pp.1699-1707
    • /
    • 2003
  • Coriolis mass flowmeter(CMF), which can measure the mass flow directly, is getting rapid attention for the industrial and custody transfer purpose. In order to study the characteristics and the applicability of CMF, it is tested with the national flow standard system. Two types of sensing tube, U-type and straight type, are employed in the test. Water, spindle oil and viscosity Standard Reference Material whose viscosities are 1, 20 and, 67 $\textrm{mm}^2$/s, respectively, are studied. It is shown that the linearity of CMF is getting deteriorated as the fluid viscosity increases, which is due to the zero drift and the relaxation time of the fluid. To test its applicability in the case of high pressured gas, it is calibrated using compressed air, It shows 1∼l.6 % deviations compared to the calibration results using water. It concludes that the fluid velocity in CMF should be lower than the sonic velocity. In addition, the effects of the vibration from the pipeline and pump on CMF as well as the long term stability are studied.

Angiogenic Inhibitory Effect of Zingiberis Rhizoma (건강의 혈관신생 억제효과에 관한 연구)

  • Nam Sang Choon;Myung Eu gene;Kang Hee;Shim Bum Sang;Kim Sung Hoon;Choi Seung Hoon;Ahn Kyoo Seok
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.18 no.6
    • /
    • pp.1608-1612
    • /
    • 2004
  • This study was conducted to investigate angiogenic inhibitory effect of Zingiberis Rhizoma methanol extract using ECV-304 cells and HT1080 fibrosarcoma cells. The viability of ECV-304 was 30% at 50㎍/㎖ of Zingiberis extract and that of HT1080 was 30% at 100㎍/㎖. Using the BrdU incorporation assay, Zingiberis inhibited the DNA synthesis of ECV-304 and HT1080 by 70% and 50% at 200㎍/㎖. In tube formation assay, at 10㎍/㎖ of Zingiberis, tube network began to degrade and at higher doses, it was completely destroyed. Zymography demonstrated that Zingiberis extract decreased MMP-9 at 10㎍/㎖ and higher doses remarkably inhibited the expression of MMP-9. These data indicate that Zingiberis Rhizoma has angiogenic inhibitory effects and shows the possibility of future anti-metastatic drug.

The Effects of the Systematic Breathing Exercises Program on Recovery of Patients with Pneumothorax (체계적인 호흡운동 프로그램이 기흉환자의 회복에 미치는 효과)

  • Kim, Yong Rye;Park, Sang Youn
    • Journal of Korean Critical Care Nursing
    • /
    • v.5 no.2
    • /
    • pp.28-36
    • /
    • 2012
  • Purpose: The purpose of this study was to examine the effects of the systematic breathing exercise program on recovery of patients with pneumothorax. Methods: An nonequivalent interrupted time-series control group posttest design was used. Participants were 40 inpatients (Experimental Group; 20, Control Group; 20) at the one University Hospital in U city. The systematic breathing exercise program including education on deep breathing exercise using incentive spirometry, Range of motion (ROM) exercise in shoulder joint, walking exercise and feedback were provided to the experimental group, while the control group carried out deep breathing exercise using incentive spirometry. The duration of chest tube insertion, duration of hospitalization, and frequency of analgesics use were measured. The data were analysed by a SPSS/WIN program. Results: The duration of chest tube insertion and duration of hospitalization in the experimental group were significantly shorter than the control group. However, there is no difference of the frequency of analgesics use between the experimental group and control group. Conclusion: The result showed that the systematic breathing exercise program was effective to improve recovery of patients with pneumothorax. This program can be applied in hospitals for patients with pneumothorax as one of the nursing intervention modalities.

  • PDF

Analysis of lateral behavior of composite pile (복합말뚝의 수평 거동 분석)

  • Seon, Seok-Yun;Kwak, No-Kyung;Lee, Song
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2008.03a
    • /
    • pp.1195-1205
    • /
    • 2008
  • Composite piles have been used in ground conditions where conventional piles are unsuitable or uneconomical. They may consist of a combination of timber and concrete pile in Europe. One method of doing this was to drive a steel tube to just below water level, and a concrete pile was lowered down it and driven to the required level where corrosion was susceptible in U.K. Recently, a fiber reinforced polymer (FRP) composite pile was developed to use in many marine locations for piers and waterfront buildings in the USA(Hoy, 1995; Phair, 1997). A steel composite (SC) pile reinforced concrete spun pile with steel tube was also proposed and used for the foundation acting a high lateral earthquake load. Composite piles have been developed and researched to increase lateral resistance or to prevent corrosion in marine structures. In paper, the composite pile consisting of the steel upper portion and the concrete lower portion is proposed and are carried out several tests to confirm the capacity of the pile such as lateral load test, dynamic load tests and bending test. It is noted that the composite pile would be a economical pile being capable of increasing lateral resistance.

  • PDF

Characteristics of ultrafine $SiO_2$ particle synthesized by Electro-hydyodynamic spray (전기-수력학적 분사에 의해 합성된 초미세 $SiO_2$ 입자의 특성)

  • Yoon, J.U.;Yang, T.H.;Ahn, K.H.;Choi, M.S.
    • Proceedings of the KSME Conference
    • /
    • 2000.11b
    • /
    • pp.174-179
    • /
    • 2000
  • Ultrafine particles have been used widely in many high technology industrial areas. The spherical nonagglomerated and uniform nanometer-size $SiO_2$ particles are synthesized by the direct injection of TEOS(Tetraethyorthosilicate) using electro-hydrodynamic spray ins method. Electro-hydrodynamic spray can generate in the range of submicron-size TEOS particles with high electric charge by applying a high electric field between the liquid injection nozzle and the reaction tube. This TEOS particles are thermally decomposed or oxidized to produce nanometresized $SiO_2$ particles in the reaction tube. Spherical, nonagglomerated and ultrafine particle generated and examined at furnaced temperature, $800^{\circ}C$ and TEOS flowrate of 0.49 or $1.00cm^3/hr$ using SEM and SMPS. As the total gas flowrate changes from 1.51pm to 5.01pm, the mean diameter of $SiO_2$ particle decreases from 120 nm to 68nm.

  • PDF

Energy Balance by Carbon and Nitrogen Balance Technique in White Leghorn and Rhode Island Red Hens Fed Maize- and Broken Rice-Based Diets

  • Jadhao, S.B.;Tiwari, C.M.;Chandramoni, Chandramoni;Khan, M.Y.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.12 no.7
    • /
    • pp.1080-1084
    • /
    • 1999
  • Carbon (C) and nitrogen (N) balance technique was used to determine energy balance in Rhode Island Red (RIR) and White Leghorn (WL) laying hens fed maize-and broken rice (BR)- based diets. Carbon and nitrogen intake and outgo were determined for three days on ad libitum fed diets followed by 2/3 of ad libitum intake for next three days. Carbon analysis was done by using four 'U' tubes in which carbon dioxide released during bomb calorimetry was absorbed on drierite in tube 1 and 2 whereas tube 3 and 4 contained sodalime self indicating granule. Carbon in $CO_2$ was determined by an open circuit respiration system. Energy retention (E, kcal) was calculated as E = 12.386 C (g) - 4.631 N (g). By regressing metabolisable energy (ME) intake on energy balance, maintenance ME requirement of RIR was 128 whereas, that of WL hens was $144kcal/kg\;W^{0.75}/d$. Effciency of utilization of ME for maintenance from BR-based diet in RIR hens was equal but in WL hens it was 11% less than maize-based diet.