• 제목/요약/키워드: Type of Installation

검색결과 1,526건 처리시간 0.029초

자속구속형 고온초전도 사고전류 제한기의 히스테리시스 특성 분석 (Analysis on Hysteresis Characteristics of Flux-Lock Type HTSC Fault Current Limiter)

  • 임성훈;한병성;박형민;조용선;한태희;두호익;최효상
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2006년도 춘계학술대회 논문집
    • /
    • pp.493-495
    • /
    • 2006
  • The hysteresis characteristics of flux-lock reactor, which is an essential component of flux-lock type superconducting fault current limiter (SFCL), was investigated. The hysteresis loss of iron core in flux-lock type SFCL does not happen due to its winding's structure especially in the normal state. From the equivalent circuit for the flux-lock type SFCL and the fault current limiting experiments, the hysteresis curves could be drawn. Through the hysteresis curves together with the fault current level due to the inductance ratio for the 1st and 2nd windings, the increase of the number of turns in the 2nd winding of the flux-lock type SFCL had a role to prevent the iron core from saturation.

  • PDF

피크전류제한 설정에 따른 피크전류제한 기능을 갖는 자속구속형 초전도한류기의 고장전류제한 특성 분석 (Analysis on Fault Current Limiting Characteristics According to Peak Current Limiting Setting of a Flux-Lock Type SFCL with Peak Current Limiting Function)

  • 고석철
    • 조명전기설비학회논문지
    • /
    • 제26권12호
    • /
    • pp.68-73
    • /
    • 2012
  • In this paper, the fault current limiting characteristics of a flux-lock type superconducting fault current limiter (SFCL) with peak current limiting function were analyzed through its short-circuit tests. The setting condition for the peak current limiting operation was derived from its electrical equivalent circuit, which was dependent on the inductance ratio between the third coil and the first coil. Through the analysis on the short-circuit tests for the flux-lock type SFCLs with the different inductance ratio between the third coil and the first coil, the setting value for the peak current limiting operation of the flux-lock type SFCL with peak current limiting function could be confirmed to be adjusted with the variation of the inductance ratio between the third coil and the first coil.

국내 지중송전선로 포설형태와 시스순환전류와의 상관관계 검토 (A Study on the Correlation between Sheath Circulating Current and Installation Type of Domestic Underground Transmission Power Cables)

  • 김남열;정채균;이종범;윤양웅;강지원
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 A
    • /
    • pp.484-486
    • /
    • 2002
  • In this paper, installation type is analyzed into a single and mixed burying type on burying situation of domestic underground transmission cables, and problem of underground cable is discussed with investigating the relation between burying type and sheath circulation current. Investigated cable systems are 520 T/L which have 512T/L for 154kV and 8T/L for 345kV. The authors consider that the analysis of sheath circulating current with burying type will contribute for setting reduction methods of sheath circulation current.

  • PDF

A Production-Installation Simulation Model of Free-Form Concrete Panels

  • Lim, Jeeyoung;Lee, Donghoon;Na, Youngju;Lim, Chaeyeon;Kim, Sunkuk
    • 국제학술발표논문집
    • /
    • The 6th International Conference on Construction Engineering and Project Management
    • /
    • pp.401-404
    • /
    • 2015
  • Demand on free-form buildings is gradually increasing, yet owing to the difficulty of production-installation work, several problems occur in the construction phase upon construction of a building, including the increased cost and construction duration, and reduced constructibility. To solve these problems, a techonology to produce FCP using a CNC(Computerized Numeric Control) machine is developed. The technology is that the information of designed free-form buildings to the CNC machine is transferred, and the transferred information is used for RTM(Rod-Type Mold, the mold shaped by back-up rods) and PCM(Phase Change Material) shaping, and the shaped RTM and PCM have the role of molds to produce FCP. Construction duration and project cost are limited in building sites, so the efficiency of processes like production-installation of FCP for application of the technology is significant. Since it is almost impossible to change the production-installation process at the construction phase when they are established, process should be deliberately decided. Therefore, the purpose of the study is to propose a production-installation simulation model of free-form concrete panels, in aspect of PCM. This paper is establishing the process for production-installation of FCP, estimating time required by each construction type and proposing a time simulation model that changes according to various constraints based on the analyses. With the time simulation model, it will be possible to build a cost model and to review the optimal construction duration and project cost.

  • PDF

고압가스 사용시설 내 안전밸브 설치유형별 리스크 분석 (Risk Analysis for Installation Types of Pressure Safety Valve used in the High-pressure Gas Facility)

  • 김명철;우정재;이형섭;백종배
    • 한국안전학회지
    • /
    • 제32권4호
    • /
    • pp.129-136
    • /
    • 2017
  • This study investigated the probability of possible accident through qualitative and quantitative analysis of the pressure safety valve types installed in facilities using high pressure gas to compare the installation domestic and foreign pressure safety valve standards sought the safety characteristics and safety improvement direction accordingly. The three types are the case where the shut-off valve is not installed at the front of the PSV (Case A), If a shut-off valve is installed at the front of the PSV for inspection (Case B) and If a shut-off valve is installed in front of PSV (C.S.O), PSV is installed in parallel (Case C). Three types of cases were compared with FTA and HAZOP. The results of study of the possible accidents due to over-pressure safety valve installation type, used in a high-pressure gas facilities was shows in the following order Case B > Case A > Case C. The results of analysis through FTA was in order to protect the reservoir for the possible occurring of accident the safety valve installation is depend on its type. In the FTA analysis, defects in the device itself which attached to the storage tank as a substitute for analysis of the probability of operator mistakes was Case B with as high as $2.01{\times}10^{-6}$. Depending on the type of installation analysis of Case B in order to ensure safety is prohibited to install shut-off valve and believes that mandatory regulations are needed. Rationally installing of pressure safety valve in the high pressure using facilities will be expected to improve the industrial safety from severe accidents such as high-pressure gas fire explosion.

Feasibility Analysis for Introducing ESCO Program of LED Luminaire Replacements in Schools

  • Shin, Hyunman;Jang, Woojin
    • 조명전기설비학회논문지
    • /
    • 제30권1호
    • /
    • pp.8-13
    • /
    • 2016
  • Public institutions should replace their luminaires with LED lighting by 2020 to save energy. Because the LED lighting installation rate in schools has not yet reached the legal goal, the ESCO program feasibility was investigated. The amount of electricity used, electric rates, times of use in classrooms and fluorescent lighting maintenance costs etc., as well as the elements of lighting maintenance were analyzed. In the case of schools, the lamp usage time was so short that the ESCO projects with only energy savings were impossible. In order to execute the ESCO projects, the maintenance cost savings by replacing an existing luminaire should be considered and the introduction of the relatively cheaper tube type LED lamp than the flat type LED luminaire was required.

Mid-Block상의 버스정류장과 횡단보도 이격거리를 고려한 버스정류장 배치형태 기준 연구 (A Guideline for the Location of Bus Stop Type considering the Interval Distance of Bus Stops and Crosswalks at Mid-Block)

  • 이수범;강태욱;강동수;김장욱
    • 대한교통학회지
    • /
    • 제28권2호
    • /
    • pp.123-133
    • /
    • 2010
  • 현재 국내의 횡단보도 설치 관련 기준은 육교 지하차도 및 다른 횡단보도로부터 200m 이내는 중복설치를 금하고 있다. 만약 횡단보도를 설치하고자 할 때는 지방경찰청장이 타당성을 검토하여 설치하도록 규정하고 있으나, 횡단보도의 설치형태와 세부기준은 미흡한 실정이다. 본 연구에서는 Mid-Block상의 버스정류장 배치형태(접근부, 유출부)에 따른 각각의 사고예측모형을 개발하였으며, 사고건수와 사고심각도를 종속변수, 버스정류장과 횡단보도 이격거리, 교통량, 보행량을 독립변수로 하는 포아송 회귀모형식을 개발하였다. 유출부모형의 경우 연간 교통사고 심각도는 버스정류장과 횡단보도간의 이격거리, 교통량, 보행량의 증가에 따라 사고와 양(+)의 관계로 증가하고, 접근부 모형의 경우는 교통량, 보행량의 증가에 따라 사고와 양(+)의 관계로 증가하지만 버스정류장과 횡단보도간의 이격거리는 음(-)의 관계로 분석되었다. 따라서, 교통사고를 최소화할 수 있는 버스정류장과 횡단보도 이격거리는 횡단보도 접근형과 유출형의 혼합형인 횡단보도의 경우는 이격거리 65m일 때 최적의 배치형태로 분석되었으며, 유출부와 접근부 사고 모형식을 통해서 얻은 최적 이격거리가 60m~70m로 나타났다.

새만금해역 자동수질모니터링시스템 구축 (Construction of the Automatic Water Quality Monitoring System for the Saemankeum)

  • 김원장;박상현;이형주;이광야
    • 한국농공학회:학술대회논문집
    • /
    • 한국농공학회 2002년도 학술발표회 발표논문집
    • /
    • pp.441-444
    • /
    • 2002
  • In recent, industrialization increases the level of pollution load in sea areas, and the inflows of pollutants to public sea areas cause sudden and wide-range of influence to the water quality and the ecosystem. To prepare for these kinds of unpredictable water pollution issues, the necessity is emerging to build an automatic water quality monitoring system, which can monitor and alarm the water quality changes of the subject sea areas. For the ongoing installation plan of the automatic water quality monitoring system around the Saemankeum sea area, this report compares and analyzes its installation conditions as well as the physical and chemical characteristics of the in-situ type and the water-sampling type of the automatic water quality monitoring equipments, and subjects to provide elementary data for the system installation in the Saemankeum.

  • PDF

CNG버스의 연료탱크 설치방법에 따른 응력과 유동해석 (Stress and Flow Analysis due to Installation Method of Fuel Tank at CNG Bus)

  • 조재웅
    • 한국기계기술학회지
    • /
    • 제13권4호
    • /
    • pp.15-21
    • /
    • 2011
  • The safety at this study is investigated by flow or stress analyses due to configuration or installation direction of fuel tank in the existing CNG bus. In case of the lower ceiling with sharp type, the equivalent stress due to the explosion of fuel tank is less than the type of flat or arc. it becomes safer on passenger. In case of the installation direction of fuel tank in the existing CNG bus, the stress applied on the lower ceiling at transverse direction becomes less than at longitudinal direction. It is more stable on the safety of passenger. The harm on the explosion accident can be prevented by use of the analysis result at this study.

저압용 SPD가 설치된 전력선통신에서 데이터전송 성능 향상 (A Method for Enhancing Data Transmission Performance in the Power-Line Communication Channel with Low-Voltage Surge Protective Devices)

  • 최종민;전태현
    • 조명전기설비학회논문지
    • /
    • 제26권2호
    • /
    • pp.78-85
    • /
    • 2012
  • Low-Voltage power lines should equip surge protection devices which protect electronic equipments and human lives against lightning and abnormal voltages. Data transmission capacity of the power line is determined by frequency characteristics of the surge protective devices. To analyze the effects of surge protective devices on the data transmission performance, various combinations of installation methods are tested which include ZnO varistor elements that is compatible with class I, class II and class III. The result claims that ZnO varistor for class III is found to be one of the main factors that deteriorates the transmission performance. To overcome this problem a serial connection methed between Gap type SPD and ZnO varistor is proposed. With the proposed scheme, laboratory experimental results show that the data transmission performance can be improved up to 91.9[%] with proper SPD combination.