Experimental Study on Improvement of Pipe-rack Joint (Pipe-rack접합부 개선방법에 관한 실험적 연구)

  • Lee, Jong-Kun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.22 no.4
    • /
    • pp.1-9
    • /
    • 2018
  • The development of new technology and process in industrial Plant which builds integrated structures, facilities and systems. Has become a key element for strengthening its competitiveness. Although domestic industrial Plant has demonstrated excellence in technology with a persistent increase in order quantity and orders received, the technology gap between countries has narrowed due to global construction trend. Therefore, it is necessary to develop new technology that could help overcome constraints and limitations of the current one to follow the trend in the age of unlimited competition. This study has focused on assembly technology of Pipe-rack joint connection in an effort to strengthen technological competitiveness in industrial Plant. Through an analysis of earlier studies on Pipe-rack and a coMParative analysis of strengths and weaknesses of current assembly technology of it, a new design plan has been made to improve it efficiently. In doing this, standards for design factors of both structural and performance features have been drawn, and value of stress, strain, moment and rotation has been calculated using finite element analysis. As a result, installation technology of modular type Pipe-rack, which has not been developed in Korea and is differentiated from the current one, has been developed. It is considered that the technology reduces work time and saves cost due to simplified joint connection of steel structure, unlike the current one. Moreover, since it is installed without a welding process in the field, industrial accidents would be reduced, which is likely to have economic competitiveness and satisfy.

Performance Evaluation of Full Scale Reinforced Subgrade for Railroad with Rigid Wall Under Static Load (정하중 재하 시 실물 강성벽 일체형 철도보강노반의 성능평가)

  • Kim, Dae-Sang
    • Journal of the Korean Geosynthetics Society
    • /
    • v.14 no.3
    • /
    • pp.31-42
    • /
    • 2015
  • The Reinforced subgrade for railroad (RSR) was constructed for one way railway line with the dimension of 5 m high, 6 m wide and 20 m long to evaluate its performance under train design load. The RSR has characteristics of short length (0.3-0.4 H) of reinforcement and rigid wall, 30 and 40 cm vertical spacing of reinforcement installation. To enhance economics and constructability, three kinds of connections (welding, hinge & bolt, bold wire) were also designed to realize the integration between rigid wall and reinforced subgrade. Two times of static loading tests were done on the full size railroad subgrade. The maximum applied pressure was 0.98 MPa (the maximum test load 5.88 MN), which corresponds to 19.6 times of the design load for railroad subgrade, 50 kPa. The performance on the RSR was evaluated with the safety on the failure, subgrade bearing capacity and settlement, horizontal displacement of wall, and reinforcement strain. Based on the full scale test, we confirmed that the RSR with the conditions of 0.35 H (35% of height) short reinforcement length, hinge & bolt type connection for integration between rigid wall and reinforced subgrade, and 40cm vertical spacing of reinforcement installment shows good performance under train design load.

The Realization of RFID Tag Data Communication System Using CC1020 (CC1020을 이용한 RFID Tag 데이터 통신 시스템 구현)

  • Jo, Heung-Kuk
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.15 no.4
    • /
    • pp.833-838
    • /
    • 2011
  • RFID system in manufacturing industry is used to collect, categorize, and process the data of products. To install RFID system for a large factory, a large amount of wired data communication network is necessary for RS232 communication. If the installed location of RFID system in the factory is changed or extended, a reinstallment is required for the already installed wired data network. A large amount of time/financial reinvestment is necessary for such reinstallation. By using wireless data communication network, however, the initial installation and reinstallation are very simple. In this paper, we implemented a wireless communication system and RFID system. We used the CC1020 chip for wireless communication system and EM4095 chip for RFID system. CC1020 chip enables highly-reliable data communication, and by setting a simple status register, it can switch between transmitting/receiving status and it can choose the desired frequency of either 400 MHz or 900 MHz. Also, Communication range is 50 m, if external antenna is used. EM4095 is a chip for RFID reader system with the carrier frequency of 125 KHz. This chip can implement the reader system by connecting a small number of components. And EM4100 was used for RFID system. EM4100 is read-only type. Atmega128 is used to control a wireless communication system and RFID system. We confirm that the system can communicate without error up to 50 m from sender. In the paper, the circuit diagram and operation program for CC1020 and RFID system are presented. The system used in the experiment is shown in pictures, and the data movement pattern of CC1020 is shown in the diagram, and the performance of each transmission method is presented.

Assessment of Plant Growth and Soil Properties of Extensive Green Roof System for Rhododendron indicum Sweet (영산홍을 이용한 저관리 옥상녹화 시스템의 식물생육 및 토양특성 평가)

  • Kim, In-Hea;Huh, Keun-Young;Shin, Hyeon-Cheol;Park, Nam-Chang
    • Horticultural Science & Technology
    • /
    • v.28 no.6
    • /
    • pp.1057-1065
    • /
    • 2010
  • Recent urban concerns over environmental problems have furthered interest in green roof system. Plant growth and load bearing capacity of an underlying roof are key factors to determine an optimal system. This study was carried out to develop an optimal extensive green roof system for shrubs assessing the effects of substrate type and soil depth on the growth of $Rhododendron$ $indicum$ Sweet. in the experimental systems with different soil types and depths from 2001 to 2008. Substrate types of perlite alone and blended with sandy loam (v/v, 1:1) were used on the experimental systems with depths of 30 cm, 45 cm, and 60 cm. The survival rate of the plants on the perlite alone + 45 cm soil depth system (RS-A-45) was 100% during the experimental period, while those on the perlite alone + 30 cm soil depth system (RS-A-30) and perlite blended + 60 cm soil depth system (RS-B-60) showed 33% and 67%, respectively, in 2008. The overall plant growth and soil properties of RS-A-45 were superior to the others. At 8 years after installation, the total weight of RS-A-45 including plant fresh weight was about $376.6kg{\cdot}m^{-2}$ in field capacity indicating RS-A-45 can be optimal extensive and light weight green roof system.

Factors Influencing Field Monitoring of the Oriental Fruit Moth, Grapholita molesta, with Sex Pheromone (성페로몬을 이용한 복숭아순나방(Grapholita molesta) 모니터링에 영향을 주는 요인)

  • Kim, Yong-Gyun;Jung, Sung-Chae;Bae, Sung-Woo;Kwon, Bo-Won;Yoon, Hyang-Mi;Hong, Yong-Pyo
    • Korean journal of applied entomology
    • /
    • v.46 no.3
    • /
    • pp.349-356
    • /
    • 2007
  • Three active components (Z8-12:Ac, E8-12:Ac, and Z8-12:OH) are known in sex pheromone of the oriental fruit moth, Grapholita molesta, and have been commercially available to apply for population monitoring and mating disruption. However, there have been variation among commercial products in pheromone composition and amount impregnated in each pheromone releaser. This study was performed to optimize factors influencing on pheromone monitoring of G. molesta by analyzing pheromone composition/amount, effective period of releaser, and trap type/placement in apple trees. High purity of Z8-12:Ac component was effective to attract males, in which 96% or more of cis acetate isomer component appeared to be optimal composition. Pheromone amounts ($0.01-1\;{\mu}g$) impregnated in each rubber dispenser did not give significant effect on monitoring during 90 days from June to August. "Delta" trap was much more efficient than "cone" trap to collect males. Trap installation was another factor, in which placing traps at canopy level was much efficient than at trunk or ground levels. Pheromone trap monitoring with these optimal factors indicated three to four adult peaks from June to September in addition to high overwintering population from April to May in pesticide-applied orchards in Andong, Korea.

Current on the Heat Loss in Greenhouses during Winter Season - Case Study Based on Gyeongnam Area - (동절기 온실의 열 손실에 관한 실태조사 - 경남지역을 중심으로 -)

  • Im, Jae Un;Yun, Sung Wook;Kim, Hyeon Tae;Yoon, Yong Cheol
    • Journal of Bio-Environment Control
    • /
    • v.22 no.1
    • /
    • pp.73-79
    • /
    • 2013
  • An experiment was conducted to study incidences of heat loss in greenhouse in Gyeongnam province using thermal imaging camera in order to determine ways minimizing greenhouse heat loss. Measurements of this work showed that temperature differences between two experiment zones before and after installation of thermal curtains were about $2.0{\sim}3.0^{\circ}C$ and $1.0{\sim}2.0^{\circ}C$ respectively. There was a high correlation between the temperature data measured using a thermal imaging camera and a temperature sensor. There was no serious difference among areas, but between places on the first and second floor with thermal curtains for heat insulation, there was a relatively larger heat loss on the first floor than the second floor. Then in general the greenhouse types had no particular bearing on this matter, there was a relatively large heat loss in the parts of side wall window, the gaps and the parts folded of horizontal thermal curtains, the gutter parts, and the gaps of thermal curtain in the side wall window and facade back side for heat insulation, aren't completely sealed. It was found that there was a substantial heat loss due to infiltration through cracks on covering material, doors, ventilating openings, roof gables and floors, in particular.

Mirror Manipulator with Independent Adjustability Using an External Spherical Joint (외부 구형관절을 이용한 조정 독립형 거울조정기)

  • 길계환;김창균;나승유;이재민;윤화식;윤무현;백성기
    • Journal of the Korean Vacuum Society
    • /
    • v.10 no.2
    • /
    • pp.145-154
    • /
    • 2001
  • A new type of modular mirror manipulator with independent adjustability was developed for the EPU6 beamline under construction at the Pohang Accelerator Laboratory. The mirror manipulator was designed so that the angular displacements of roll and pitch rotations do not introduce translational displacements and are independent with each other by positioning the mirror center to the center of a newly devised spherical joint. Manipulating its roll and pitch micrometers, the rotation angles of a dummy mirror were measured at an accuracy of 5 $\mu$rad using a gravity-referenced inclinometer. While the designed angular resolution was 3.937 $\mu$rad/$\mu\textrm{m}$, measured angular resolutions were 3.94 $\mu$rad/$\mu\textrm{m}$ for roll rotation and 3.85 $\mu$rad/$\mu\textrm{m}$ for pitch rotation. The effect of roll rotation on pitch angles was measured to be -3.18% and the effect of pitch rotation on roll angles was measured to be -5.21%. As the mirror manipulator was designed with emphases on independent adjustability and standardization, it results in eases of manufacturing, installation and adjustment as well as reductions of development period and design cost of mirror manipulators for various types of mirrors.

  • PDF

A study on the excavation cycle by the drill-and-blast method for a room-and-pillar underground structure (주방식 지하구조물의 발파 굴착공정 분석 연구)

  • Lee, Chul-Ho;Hyun, Young-Hwan;Hwang, Je-Don;Choi, Soon-Wook;Kang, Tae-Ho;Chang, Soo-Ho
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.18 no.6
    • /
    • pp.511-524
    • /
    • 2016
  • Since a room-and-pillar underground structure is characterized by its grid-type array of room and pillar, its economical efficiency can be governed by excavation sequence. In this study, the construction period by the drill-and-blast method as a excavation method for a room-and-pillar underground structure was examined. In addition, the parallel excavation sequence was considered as the main sequence of a room-and-pillar underground structure. Sequences of mucking and support installation were derived to estimate the total excavation cycle by taking the case of a road tunnel into consideration. From the excavation cycle of room-and-pillar underground structure, the relationship between available maximum and minimum numbers of jumbo drill machines depending on the number of faces in operation was suggested.

A Study on Users' Evaluation for the Trail Facilities in Gayasan National Park, Korea (가야산국립공원 탐방로 보행시설에 대한 탐방객 평가 연구)

  • Kwon, Tae-Ho
    • Korean Journal of Environment and Ecology
    • /
    • v.24 no.3
    • /
    • pp.293-301
    • /
    • 2010
  • The purpose of this study is to figure out visitor's attitudes for trail facilities in Gayasan National Park in order to provide the basic information for effective installation and maintenance of trail facilities. The questionnaire survey on two trails were conducted to 227 visitors on the way back home after using the trails. The use characteristics of two trails were a little different from each other, and the conditions of two trails were rated relatively high both in quantity and quality. By the evaluation of 5 types of trail facilities in Haein trail and 4 types in Baegun trail, The responses were noticeably positive about wood deck, log steps with stones and wood steps in Haein trail and about deck-type wood steps and log fences in Baegun trail from the point of three aspects; harmony with nature, resources conservation and user convenience. On the other hand it seems necessary to replace the steel steps of both trails with eco-friendly materials. So, from now on it is necessary for introducing the trail facilities in National Parks to apply the eco-friendly materials extensively and to upgrade the design aspects comprehensively of harmony with nature, resources conservation and user convenience

A Study on the Corrosion Prevention of the Integral Series Generator for Military Vehicles (군용차량용 엔진일체형 직렬 발전기 부식 방지에 관한 연구)

  • Kang, Tae-Woo;Kim, Seong-Gon;Shin, Cheol-Ho;Lee, Kye-Sub
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.6
    • /
    • pp.74-79
    • /
    • 2019
  • The military vehicle produces electric power through an engine-integrated serial hybrid generator that is connected to the engine and does not have a separate generator installation space. However, depending on the mechanical characteristics of the connection between the generator and the engine, iron oxide for internal rusting and lubrication grew scattered. The iron oxide is adhered to the starter to deteriorate the starting performance, and there is a problem that the noise of the leg due to wear of the gear is increased. To solve this problem, the connection spline material and the surface treatment of the engine were improved and the shape was changed to a grease sealing type to prevent the generation of iron oxide inside. As the shape of the generator connector composing the shafting system was changed, the integrity of the structure was confirmed through the torsional endurance test. In addition, through the actual vehicle load test, it was verified that no corrosion occurred during the target life span without internal corrosion. It was confirmed that the anti-scattering structure of the grease effectively suppresses the generation of iron oxide, thereby reducing the noise generated from the generator. In this paper, we propose a fundamental solution to the degradation of the starter and the noise generation by preventing the back corrosion caused by the serial hybrid generator installed between the engine and the transmission.