• Title/Summary/Keyword: Type V

Search Result 5,530, Processing Time 0.034 seconds

Estimation of fundamental natural period of vibration for reinforced concrete shear walls systems

  • Shatnawi, Anis S.;Al-Beddawe, Esra'a H.;Musmar, Mazen A.
    • Earthquakes and Structures
    • /
    • v.16 no.3
    • /
    • pp.295-310
    • /
    • 2019
  • This study attempts to develop new simplified approximate formulas to predict the fundamental natural periods of vibration (T) for bearing wall systems engaged with special reinforced concrete shear walls (RCSW) under seismic loads. Commonly, seismic codes suggested empirical formulas established by regression analysis of measured T for buildings during earthquake motions. These formulas depend on structure type, building height, number, height and length of SW, and ratio of SW area to base area of structure. In this study, a parametric investigation is performed for T of 110 selected models of bearing RCSW systems with varying structural height, configuration of horizontal plans including building width, number and width of bays, presence of middle corridors and core SWs. For this purpose, a 3D non-linear response time history (TH) analysis is implemented using ETABS v16.2.1. New formulas to estimate T are anticipated and compared with those obtained from formulas of IBC 2012 and ASCE/SEI 7-10. Moreover, the study examines responses of an arbitrarily two selected test model of 60 m and 80 m in height with presence of SWs having middle corridors. It is observed that the performance of the tested buildings is different through arising of considerable errors when using codes' formulas for estimating T. Accordingly, using the present proposed formulas exhibits more reasonable and safer design compared to codes' formulas. The results showed that equitable enhancement is promising to improve T formulas approaching enhanced and accurate estimation of T with reliable analysis, design, and evaluation of bearing RCSW systems.

Hydrogen Production from Water Electrolysis Driven by High Membrane Voltage of Reverse Electrodialysis

  • Han, Ji-Hyung;Kim, Hanki;Hwang, Kyo-Sik;Jeong, Namjo;Kim, Chan-Soo
    • Journal of Electrochemical Science and Technology
    • /
    • v.10 no.3
    • /
    • pp.302-312
    • /
    • 2019
  • The voltage produced from the salinity gradient in reverse electrodialysis (RED) increases proportionally with the number of cell pairs of alternating cation and anion exchange membranes. Large-scale RED systems consisting of hundreds of cell pairs exhibit high voltage of more than 10 V, which is sufficient to utilize water electrolysis as the electrode reaction even though there is no specific strategy for minimizing the overpotential of water electrolysis. Moreover, hydrogen gas can be simultaneously obtained as surplus energy from the electrochemical reduction of water at the cathode if the RED system is equipped with proper venting and collecting facilities. Therefore, RED-driven water electrolysis system can be a promising solution not only for sustainable electric power but also for eco-friendly hydrogen production with high purity without $CO_2$ emission. The RED system in this study includes a high membrane voltage from more than 50 cells, neutral-pH water as the electrolyte, and an artificial NaCl solution as the feed water, which are more universal, economical, and eco-friendly conditions than previous studies on RED with hydrogen production. We measure the amount of hydrogen produced at maximum power of the RED system using a batch-type electrode chamber with a gas bag and evaluate the interrelation between the electric power and hydrogen energy with varied cell pairs. A hydrogen production rate of $1.1{\times}10^{-4}mol\;cm^{-2}h^{-1}$ is obtained, which is larger than previously reported values for RED system with simultaneous hydrogen production.

Usefulness of the orbicularis oculi myocutaneous flap in periorbital reconstruction

  • Kim, Geon Woo;Bae, Yong Chan;Kim, Joo Hyoung;Nam, Su Bong;Kim, Hoon Soo
    • Archives of Craniofacial Surgery
    • /
    • v.19 no.4
    • /
    • pp.254-259
    • /
    • 2018
  • Background: The esthetic and functional outcomes of periorbital defect reconstruction are very important because of the complex anatomy and specialized functions of this region. The orbicularis oculi myocutaneous (OOMC) flap is useful for the reconstruction of periorbital defects. But, according to the location and depth of the defects, the reconstruction using OMC flaps with various techniques is rare. The authors have used various kinds of OOMC flaps in various situations and we present an analysis of our experiences. Methods: From November 2001 to July 2017, we used 36 OOMC flaps to reconstruct 30 periorbital defects in 25 patients. We analyzed the cause of the defect, its location, the type of concomitant surgery, the method of flap movement, and complications. Results: Of the 30 defects, basal cell carcinoma was the most common cause, accounting for 20 cases. When the used OOMC flap was classified according to the location of the defects, the switch flap was used in nine cases among 15 defects of lower eyelid, and the V-Y advancement flap was mainly used for other parts. As surgical methods according to the depth of defect were classified, all cases involving the tarsal plate were reconstructed with a composite graft. In case of skin and muscles, they were reconstructed only with OOMC flap or with full-thickness skin graft. Conclusion: The OOMC flap provides good skin quality that is very similar to that of the defect tissue. Depending on the location and depth of the defect, the OOMC flap may be used properly in a variety of ways to achieve good results.

The Radiologic Comparison of Operative Treatment Using a Hook Plate versus a Distal Clavicle Locking Plate of Distal Clavicle Fracture

  • Yoon, Byungil;Kim, Jae Yoon;Lee, Jae-Sung;Jung, Hyoung Seok
    • Clinics in Shoulder and Elbow
    • /
    • v.21 no.4
    • /
    • pp.227-233
    • /
    • 2018
  • Background: The purpose of this study was to compare the radiologic results of patients who underwent surgery with a hook plate and a locking plate in distal clavicle fractures. Methods: Sixty patients underwent surgical treatment for Neer type IIa, IIb, III, and V distal clavicle fracture. Twenty-eight patients underwent fracture fixation with a hook plate and 32 with a locking plate. Coracoclavicular distance was measured on standard anteroposterior radiographs before and after the surgery, and union was confirmed by radiograph or computed tomography taken at 6 months postoperatively. Other radiologic complications like osteolysis was also checked. Results: Bony union was confirmed in 59 patients out of 60 patients, and 1 patient in the hook plate group showed delayed union. Coracoclavicular distance was decreased more in the hook plate group after surgery (p<0.01). After 6 weeks of the hook plate removal, the coracoclavicular distance was increased a little compared to before metal removal, but there was no difference compared to the contralateral shoulder. Eleven out of 28 patients (39.3%) showed osteolysis on the acromial undersurface in the hook plate group. Conclusions: Both the hook plate group and the locking plate group showed satisfactory radiologic results in distal clavicle fractures. Both hook plate and locking plate could be a good treatment option if it is used in proper indication in distal clavicle fracture with acromioclavicular subluxation or dislocation.

Flavobacterium jocheonensis sp. nov., Isolated from Marine Green Alga Ulva pertusa

  • Choi, Ha Ri;Park, So Hyun;Heo, Moon Soo
    • Journal of Microbiology and Biotechnology
    • /
    • v.29 no.8
    • /
    • pp.1266-1272
    • /
    • 2019
  • A bacterial strain, labeled $UR11^T$, was isolated from green alga Ulva pertusa collected from Jeju Island, Korea. $UR11^T$ was identified as a gram-negative, rod-shaped, motile by gliding and aerobic bacterial strain with yellow colonies on R2A plates. The strain $UR11^T$ grew over at a temperature range of $10^{\circ}C$ to $30^{\circ}C$ (optimally at $25^{\circ}C$), a pH range of 6.0-11 (optimally at pH 7.0) and a Nacl range of 0.5-5% Nacl (w/v). Phylogenetic analysis based on 16S rRNA gene sequences revealed that strain $UR11^T$ was a member of the genus Flavobacterium. Strain $UR11^T$ shared close similarity with F. jejuensis $EC11^T$ (98.0%) F. jumunjinense $HME7102^T$ (96.1%), F. haoranii $LQY-7^T$ (95.3%), F. dongtanense $LW30^T$ (95.1%), and F. ahnfeltiae 10Alg $130^T$(94.9%). The major fatty acids (>5%) were $iso-C_{15:0}$ (33.9%), $iso-C_{15:1}$ G (12.4%), $iso-C_{17:0}$ 3-OH (9.0%), $isoC_{16:0}$ (7.0%) and $iso-C_{15:0}$ 3-OH (6.3%). The major polar lipids were phosphatidylethanolamine, seven unknown aminolipids, two unknown aminopolarlipids and two unknown lipids. DNA-DNA hybridization value was 58% at strain $UR11^T$ with F. jejuensis $EC11^T$. Based on phenotypic, chemotaxonomic and phylogenetic evidence, strain $UR11^T$ represents a novel species of the genus Flavobacterium, for which the name Flavobacterium jocheonensis sp. nov. is proposed. The type strain is Flavobacterium jocheonensis is $UR11^T$ (=KCTC $52377^T$ =JCM $31512^T$).

Influence of surface treatments and repair materials on the shear bond strength of CAD/CAM provisional restorations

  • Jeong, Ki-Won;Kim, Sung-Hun
    • The Journal of Advanced Prosthodontics
    • /
    • v.11 no.2
    • /
    • pp.95-104
    • /
    • 2019
  • PURPOSE. To evaluate the effect of surface treatments and repair materials on the shear bond strength and to measure the fracture toughness of CAD/CAM provisional restoration materials. MATERIALS AND METHODS. Four CAD/CAM (3D printing: Nextdent C&B and ZMD-1000B Temporary, CAD/CAM resin block: Yamahachi PMMA disk and Huge PMMA block) and four conventional (monometacrylate: Jet and Alike, dimetacrylate: Luxatemp and Protemp 4) materials were selected to fabricate disk-shaped specimens and divided into six groups according to surface treatment (n=10). CAD/CAM materials were repaired with Jet or Luxatemp, while conventional materials were repaired with their own materials. The shear bond strength was measured by using universal testing machine. Ten rectangular column-shaped specimens for each material were fabricated to measure the fracture toughness by single edge v notched beam technique. Statistical analysis was performed by one-way ANOVA. RESULTS. The highest shear bond strength of CAD/CAM materials was achieved by SiC paper + sandblasting. It was also accomplished when repairing 3D printing materials with Luxatemp, and repairing CAD/CAM resin blocks with Jet. Yamahachi PMMA disk showed the highest fracture toughness. Nextdent C&B showed the lowest fracture toughness value but no statistically significant difference from Alike and Luxatemp (P>.05). CONCLUSION. In order to successfully repair the CAD/CAM provisional restoration, mechanical surface treatment and appropriate repair material according to the CAD/CAM material type should be selected. The CAD/CAM provisional materials have proper mechanical properties for clinical use as compared to conventional materials.

Efficiency calibration of a coaxial HPGe detector-Marinelli beaker geometry using an 152Eu source prepared in epoxy matrix and its validation by efficiency transfer method

  • Yucel, Haluk;Zumrut, Senem;Nartturk, Recep Bora;Gedik, Gizem
    • Nuclear Engineering and Technology
    • /
    • v.51 no.2
    • /
    • pp.526-532
    • /
    • 2019
  • In this study, an in-house $^{152}Eu$ calibration source was produced from a custom epoxy matrix with a density of ${\rho}=1.14g\;cm^{-3}$, which is chemically stable and durable form after its solidification. The homogeneity of $^{152}Eu$ in matrix was obtained better than 98%. For a Marinelli beaker geometry, an efficiency calibration procedure was applied to a n-type, coaxial, 78.5% relative efficient HPGe detector in the energy range of 121.7-1408.0 keV by using in-house $^{152}Eu$ calibration source. Then the measured efficiencies for Marinelli geometry were compared with the results calculated by MEFFTRAN and ANGLE softwares for the validation. Although MEFFTRAN and ANGLE have two different efficiency transfer algorithms to calculate the efficiencies, they usually need to use a reliable and accurate reference efficiency values as input data. Hence, reference efficiency values were obtained experimentally from a multinuclide standard source for the same detector-Marinelli geometry. In the present source characterization, the corrections required for self-absorption and true coincidence summing effects for $^{152}Eu$ gamma-rays were also obtained for a such close counting geometry condition. The experimental results confirmed the validity of efficiency calculations obtained by MEFFTRAN and ANGLE softwares that are calculation tools.

Effect of thermal annealing on low-energy C-ion irradiated MgB2 thin films

  • Jung, Soon-Gil;Son, Seung-Ku;Pham, Duong;Lim, W.C.;Song, J.;Kang, W.N.;Park, T.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.21 no.3
    • /
    • pp.13-17
    • /
    • 2019
  • We investigate the effect of thermal annealing on $MgB_2$ thin films with thicknesses of 400 and 800 nm, irradiated by 350 keV C-ions with a dose of $1{\times}10^{15}atoms/cm^2$. Irradiation by low-energy C-ions produces atomic lattice displacement in $MgB_2$ thin films, improving magnetic field performance of critical current density ($J_c$) while reducing the superconducting transition temperature ($T_c$). Interestingly, the lattice displacement and the $T_c$ are gradually restored to the original values with increasing thermal annealing temperature. In addition, the magnetic field dependence of $J_c$ also returns to that of the pristine state together with the restoration of $T_c$. Because $J_c$(H) is sensitive to the type and density of the disorder, i.e. vortex pinning, the recovery of $J_c$(H) in irradiated $MgB_2$ thin films by thermal annealing indicates that low-energy C-ion irradiation on $MgB_2$ thin films primarily causes lattice displacement. These results provide new insights into the application of low-energy irradiation in strategically engineering critical properties of superconductors.

Effects of Proton Irradiation on the Microstructure and Surface Oxidation Characteristics of Type 316 Stainless Steel (양성자 조사가 316 스테인리스강의 미세조직과 표면산화 특성에 미치는 영향)

  • Lim, Yun-Soo;Kim, Dong-Jin;Hwang, Seong Sik;Choi, Min Jae;Cho, Sung Whan
    • Corrosion Science and Technology
    • /
    • v.20 no.3
    • /
    • pp.158-168
    • /
    • 2021
  • Austenitic 316 stainless steel was irradiated with protons accelerated by an energy of 2 MeV at 360 ℃, the various defects induced by this proton irradiation were characterized with microscopic equipment. In our observations irradiation defects such as dislocations and micro-voids were clearly revealed. The typical irradiation defects observed differed according to depth, indicating the evolution of irradiation defects follows the characteristics of radiation damage profiles that depend on depth. Surface oxidation tests were conducted under the simulated primary water conditions of a pressurized water reactor (PWR) to understand the role irradiation defects play in surface oxidation behavior and also to investigate the resultant irradiation assisted stress corrosion cracking (IASCC) susceptibility that occurs after exposure to PWR primary water. We found that Cr and Fe became depleted while Ni was enriched at the grain boundary beneath the surface oxidation layer both in the non-irradiated and proton-irradiated specimens. However, the degree of Cr/Fe depletion and Ni enrichment was much higher in the proton-irradiated sample than in the non-irradiated one owing to radiation-induced segregation and the irradiation defects. The microstructural and microchemical changes induced by proton irradiation all appear to significantly increase the susceptibility of austenitic 316 stainless steel to IASCC.

Effects of Injection Molding Parameters and their Interactions on Mechanical Properties of PMMA/PC Blend

  • Hoang, Van Thanh;Luu, Duc Binh;Toan Do, Le Hung;Tran, Ngoc Hai;Nguyen, Pham The Nhan;Tran, Minh Sang;Tran, Minh Thong
    • Korean Journal of Materials Research
    • /
    • v.30 no.12
    • /
    • pp.650-654
    • /
    • 2020
  • A combination of Polycarbonate (PC) material and Polymethylmethacrylate (PMMA), fabricated using an injection molding machine, has been investigated to determine its advantages, as studied in Ref. 1). This paper aims to investigate the optimization of PMMA/PC blend for both tensile yield strength and impact strength. Furthermore, interaction effects of process conditions on mechanical properties including tensile yield strength and impact strength of PMMA/PC blend by injection molding process are interpreted in this study. Tensile and impact specimens are designed following ASTM, type V, and are fabricated by injection molding process. The processing conditions such as melt temperature, mold temperature, packing pressure, and cooling time are applied; each factor has three levels. As a result, in comparison with optimization of separated responses, mechanical properties of PMMA/PC are found to decrease when optimizing both tensile and impact strengths simultaneously. The melt temperature is found to be the most significant interaction parameter with the mold temperature and packing pressure. In addition, there is more interaction between the mold temperature and cooling time. This investigation provides a useful understanding of the control of injection molding processing of polymer blends in optical application.