• 제목/요약/키워드: Two transformer

검색결과 552건 처리시간 0.027초

고정주파수 LCL타입 절연형 양방향 컨버터 해석 및 제어 (Analysis and Control of A Fixed Frequency LCL-type Isolated Bidirectional Converter)

  • 박상은;차한주
    • 조명전기설비학회논문지
    • /
    • 제30권3호
    • /
    • pp.65-72
    • /
    • 2016
  • This paper discussed the LCL-type & Isolated bidirectional dc-dc converter(BDC) with dual full bridge inverter. In order to verify the analysis of the BDC, Experimental prototype has been designed and implemented to supply constant voltage regardless of loads and proposed a method to select switching frequency that depended on two inductors' inductance ratio and transformer parameters. The proposed converter has been composed of LCL resonant network with unit inductance ratio ($L_r/L_f$=1) and then operated with fixed duty, 50% duty ratio and fixed frequency. There are some characteristics that input voltage and output voltage of the BDC is nearly identical and zero voltage turn-on switching is possible in forward and reverse mode. Finally, it has been showed that BDC is possible to commutate operating mode normally and provide constant output voltage in selected switching frequency.

Single-Stage Half-Bridge Electronic Ballast Using a Single Coupled Inductor

  • Cho, Yong-Won;Kwon, Bong-Hwan
    • Journal of Power Electronics
    • /
    • 제12권5호
    • /
    • pp.699-707
    • /
    • 2012
  • This paper proposes a single-stage half-bridge electronic ballast with a high power factor using only a single coupled inductor. Compared to conventional high power factor electronic ballasts, the proposed ballast is a simpler circuit with a low cost and a high reliability. The proposed ballast is made up of a power-factor-correction (PFC) circuit and a self-oscillating class-D inverter. The PFC and inverter stages of the proposed ballast are simplified by sharing only a single coupled inductor and two common switches. The proposed PFC circuit can achieve a high power factor and low voltage stresses of the switches. A saturable transformer in the self-oscillating class-D inverter determines the switching frequency of the ballast. Experimental results obtained on a 30W fluorescent lamp are discussed.

배전자동화시스템 적용을 위한 경제성 평가 (Economic Evaluation far the Application of the Distribution Automation System)

  • 홍순학;하복남;김호용;정경희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1993년도 하계학술대회 논문집 A
    • /
    • pp.36-38
    • /
    • 1993
  • This study considers the economic aspect of the distribution automation system, which is the decision-making criteria of the electric utilities for the investment. The feeder automation candidate region is divided into two types of the urban and the rural. The total investment cost of the feeder automation for each type is estimated. The annual cost, is also estimated, by finding the fixed charge rate. To compare the annual cost and the economic effect cost, for the investment decision-making, the costs are quantitatively estimated on the following effects : the manpower replacement, the outage cost saving, the main transformer utilization improvement, the feeder utilization improvement, and the line loss reduction.

  • PDF

A Novel Quasi-Resonant Snubber-Assisted ZCS-PWM DC-DC Converter with High Frequency Link

  • Fathy, Khairy;Kwon, Soon-Kurl
    • Journal of Power Electronics
    • /
    • 제7권2호
    • /
    • pp.124-131
    • /
    • 2007
  • In this paper, a novel type of auxiliary switched capacitor assisted edge resonant soft switching PWM resonant DC-DC converter with two simple auxiliary commutation lossless inductor snubbers is presented. The operation principle of this converter is described using the switching mode equivalent circuits. This newly developed multi resonant DC-DC converter can regulate its DC output AC power under a principle of constant frequency edge-resonant soft switching commutation by an asymmetrical PWM duty cycle control scheme. The high frequency power regulation and actual power characteristics of the proposed soft switching PWM resonant DC-DC converter are evaluated and discussed. The operating performances of the newly proposed soft switching inverter are represented based on simulation results from an applications point of view.

반도체 소자기반 펄스 전원용 게이트 구동 및 시험회로 설계 (Design of gate driver and test circuits for solid-state pulsed power modulator)

  • 공지웅;옥승복;안석호;장성록;류홍제
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2012년도 전력전자학술대회 논문집
    • /
    • pp.230-231
    • /
    • 2012
  • This paper describes a gate driver that operates numerous semiconductor switch in the solide-state pulsed power modulator. the proposed gate driver is designed to receive both the isolated drive-power and the on/off pulse signals through the transformer. Moreover, the IGBT-switch can be quickly turned off by adding protection circuit. Therefore it protects the IGBT-switch from the arc condition that frequently occurs in high-voltage pulse application. To comprehend operating characteristic of each IGBT-switch in pulse output condition, the device consisting of a high efficiency soft-switching capacitor charger and two series stacking IGBT-switch is developed. Finally, the relability of the proposed gate driver and the device for its test are proved through PSpice simulation and experiments.

  • PDF

인터리브드 풀브릿지 컨버터와 하프브릿지 인버터를 결합한 연료전지 발전 시스템 (Fuel Cell Generation System Combined Interleaved Full-bridge Converter with Half-bridge Inverter)

  • 김헌희;이희준;신수철;정용채;원충연
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2012년도 전력전자학술대회 논문집
    • /
    • pp.518-519
    • /
    • 2012
  • This paper suggested a fuel cell generation system which combined interleaved full-bridge converter with half-bridge inverter. High ratio step-up converter is essential to use the power as general voltage source. Full-bridge converter has high efficiency and can boost the input voltage to high output with transformer. With series connected capacitors, interleaved full-bridge converter and half-bridge inverter are combined. Half-bridge inverter has two fewer switches compared to full-bridge type. Also, switching loss can be reduced. The performance is verified through simulation with 1.5[kW] fuel cell generation system.

  • PDF

디스플레이용 스위칭모드 전원장치의 단락 고장분석 검출기법 (Techniques to Diagnose Short-Circuit Faults in the Switching Mode Power Supply for Display)

  • 이재원;전태원
    • 전기학회논문지
    • /
    • 제65권7호
    • /
    • pp.1186-1192
    • /
    • 2016
  • This paper proposes techniques to diagnose short-circuit faults of both the diodes and power FET in switching mode power supply (SMPS) by using a simple analog tester. The diodes in full-bridge rectifier, power FET, switching transformer, and some sensors are modelled with resistor. The total resistance value measured at the input terminal of a SMPS is analyzed when the short-circuit faults of diodes in a full bridge rectifier or power FET are occurred. The short-circuit faults of one or two diodes in a full bridge rectifier, power FET, and both the diodes in a full bridge rectifier and power FET can be detected by a range of total resistance, which is measured by the analog tester. Through experiments, the theoretical analysis for total resistance under short-circuit faults can be verified.

A 3 kW Bidirectional DC-DC Converter for Electric Vehicles

  • Ansari, Arsalan;Cheng, Puyang;Kim, Hee-Jun
    • Journal of Electrical Engineering and Technology
    • /
    • 제11권4호
    • /
    • pp.860-868
    • /
    • 2016
  • A bidirectional DC-DC converter (BDC) is an indispensable electrical unit for the electric vehicles (EVs). High efficiency, high power density, isolation, light weight and reliability are all essential requirements for BDC. In this paper, a 3 kW BDC for the battery charger of EVs is proposed. The proposed converter consists of a half-bridge structure on the primary side and an isolation transformer and a synchronous rectifier structure on the secondary side. With this topology, minimum number of switching devices are required for bidirectional power flow between the two dc buses of EVs. The easy implementation of the synchronous rectification gives advantages in terms of efficiency, cost and flexibility. The proposed BDC achieves high efficiency when operating in both modes (step-up and step-down). A 3 kW prototype is implemented to verify theoretical analysis and the performance of the proposed converter.

발전소 변압기 밀폐구조의 음향해석 (An Acoustical Analysis on the Transformer Enclosure in Power Plants)

  • 이준신;김연환;손석만
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 1997년도 추계학술대회논문집; 한국과학기술회관; 6 Nov. 1997
    • /
    • pp.244-249
    • /
    • 1997
  • The enclosure with a small opened area is extensively used in power plants to reduce the propagating noise from transformers. The radiation impedance associated with the location and width of the opened area, and the geometric configurations of internal acoustic field is very important to determine the basic acoustic characteristics of this partial enclosure. In this study, two-dimensional rectangular chambers with opened areas are investigated to examine the acoustic properties of the enclosure. The mode expansions of the physical variables defined on boundary surfaces are introduced to derive a simple algebraic equation. The acoustic characteristics can be easily predicted by this analytical approach, and the results well agree with physical grounds. Physical concepts as results of this work will be helpful to use the partial enclosure as a noise control element.

  • PDF

철도차량기지용 단권변압기의 전압강하에 대한 이론적 고찰 (A Theoretical Study on Voltage Drop of Auto-Transformer for Railway Vehicle Base)

  • 유기성;김재문
    • 전기학회논문지
    • /
    • 제67권12호
    • /
    • pp.1723-1728
    • /
    • 2018
  • In order to investigate the voltage drop compensation effect of AT for domestic railway vehicle base, the parameters of AT voltage drop of railroad car base are Z3 (Impedance of feeder line), Xn ( Distance from railroad vehicle to AT to SS), and Dn (distance between both ATs of railway vehicle).In addition, when installed in a SSP for a railway vehicle base, there is no AT and feeder line in the railway vehicle base except for the SSP for the main line and the SSP for the railway vehicle base, so that if zero or ignored, the AC single-phase two- It can be confirmed that it becomes a form.