• Title/Summary/Keyword: Two transformer

Search Result 552, Processing Time 0.021 seconds

Seismic mitigation of substation cable connected equipment using friction pendulum systems

  • Karami-Mohammadi, Reza;Mirtaheri, Masoud;Salkhordeh, Mojtaba;Mosaffa, Erfan;Mahdavi, Golsa;Hariri-Ardebili, Mohammad Amin
    • Structural Engineering and Mechanics
    • /
    • v.72 no.6
    • /
    • pp.785-796
    • /
    • 2019
  • Power transmission substations are susceptible to potential damage under seismic excitations. Two of the major seismic failure modes in substation supplies are: the breakage of brittle insulator, and conductor end fittings. This paper presents efficient isolation strategies for seismically strengthening of a two-item set of equipment including capacitive voltage transformer (CVT) adjacent to a Lightning Arrester (LA). Two different strategies are proposed, Case A: implementation of base isolation at the base of the CVT, while the LA is kept fixed-base, and Case B: implementation of base isolation at the base of the LA, while the CVT is kept fixed-base. Both CVT and LA are connected to each other using a cable during the dynamic excitation. The probabilistic seismic behavior is measured by Incremental Dynamic Analysis (IDA), and a series of appropriate damage states are proposed. Finally, the fragility curves are derived for both the systems. It is found that Friction Pendulum System (FPS) isolator has the potential of decreasing flexural stresses caused by intense ground motions. The research has shown that when the FPS is placed under LA, i.e. Case B (as oppose to Case A), the efficiency of the system is improved in terms of reducing the forces and stresses at the bottom of the porcelain. Several parametric studies are also performed to determine the optimum physical properties of the FPS.

Aging Characteristics of Power Transformer Oil and Development of its Analysis using KOSM (전력용 변압기유의 열화 특성에 KSOM에 의한 분석기법 개발)

  • 임재윤;지평식;이종필;남상천;이승렬
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.13 no.3
    • /
    • pp.56-63
    • /
    • 1999
  • In power system, substation facilities have become too complex and large according to extended power system. Also, some facilities becorre old and often break down unexpectedly. In order to improve the sectrity of transformer out of substation facilities, the development of diagnosis technique to transformer is very needed. In this paper, we developed a method to be analysis the origin and degree of aging by KSOM based on the dissolved gases in power transfonrer. KSOM can do topological mapping for the multi-dimensional pattern based on the dissolved gases to two dimensional plane. And potential possibility and degree of aging for nonna1 transfonrer are presented using the proposed quantitative criterion. Furtherrrore, the aging process of transfonrer is analyzed based on the proposed criterion to special transfonrer. To demonstrate the validity of peoposed method, case study is performed and its results are presented.sented.

  • PDF

V-t Characteristics and Survival Probability of Turn-to-Turn Models for HTS Transformer (고온초전도 변압기를 위한 턴간 모델의 V-t 특성 및 생존 확률)

  • Baek, Seung-Myeong;Cheon, Hyeon-Gweon;Nguyen, Van-Dung;Seok, Bok-Yeol;Kim, Sang-Hyun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.356-362
    • /
    • 2004
  • Using multi wrapped copper by polyimide film for HTS transformer, the breakdown and V-t characteristics of two type models for turn-to-turn, one is point contact model, the other is surface contact model, were investigated under ac and impulse voltage at 77 K. A material that is Polyimide film (Kapton) 0.025 mm thickness is used for multi wrapping of the electrode. Statistical analysis of the results using Weibull distribution to examine the wrapping number effects on V-t characteristics under at voltage as well as breakdown voltage under ac and impulse voltage in $LN_2$ was carried. Also, survival analysis was performed according to the Kaplan-Meier method. The breakdown voltages for surface contact model are lower than that of the point contact model, because the contact area of surface contact model is wider than that of point contact model. At the same time, the shape parameter of the point contact model is a little bit larger than the of the surface contact model. The time to breakdown tn is decreased as the applied voltage is increased, and the lifetime indices slightly are increased as the number of layers is increased. According to the increasing applied voltage and decreasing wrapping number, the survival probability is increased.

  • PDF

New High Performance and Low Cost Construction of Unified Power System for LCD TV Backlight Driver Circuitb (LCD TV를 위한 새로운 구조의 고성능 및 저가형 Backlight 구동 전원 통합 시스템)

  • Jang, Doo-Hee;Lee, Jae-Kwang;Roh, Chung-Wook;Hong, Sung-Soo;Kim, Jin-Wook;Lee, Hyo-Bum;Han, Sang-Kyoo
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.14 no.1
    • /
    • pp.23-30
    • /
    • 2009
  • A new high performance and low cost unified power system is proposed through investigating conventional Power-Integrated Drive(PID) system and Power-Separated Drive(PSD) system applied to LCD TV. Since the proposed system consists of two stage, namely power and inverter stage it features high efficiency and cost effectiveness. To satisfy the safety standard of the High voltage transformer, 1:1 transformer is employed between inverter and high voltage transformer. Moreover, to ensure the Zero Voltage Switching(ZVS) of all power switches and the Pulse Count Modulation(PCM) method is employed, which controls the number of pulse at the fixed frequency and fixed duty cycle. Therefore, it features high efficiency, improved heat generation, cost effectiveness and good EMI performance including no additional current balancing coil. To confirm the validity of proposed system, comparison of conventional system, verification of experimental results are presented.

High Switching Frequency and High Power Density Three-Level LLC Resonant Converter using Integrated Magnetics (Integrated Magnetics를 적용한 고속 스위칭 및 고전력밀도 3 레벨 LLC 공진형 컨버터)

  • Nam, Kyung-Hoon;Park, Chul-Wan;Bae, Ji-Hun;Ji, Sang-Keun;Ryu, Dong-Kyun;Choi, Heung-Gyoon;Han, Sang-Kyoo
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.22 no.6
    • /
    • pp.551-554
    • /
    • 2017
  • This paper proposes a three-level LLC resonant converter using integrated magnetics (IM). Given that the switch voltage stress of the proposed converter is guaranteed to be half of the input voltage, the switching losses can be greatly reduced, thereby benefitting the high-frequency operation. To reduce the volume of reactive components such as transformers, high-frequency driving and planar core are applied. However, two resonant inductors and one transformer are required because of the three-level structure and the limited leakage inductance of the planar transformer for the resonant operation. Therefore, the effect of volume reduction is not very large. In order to solve these drawbacks, this paper proposes a new IM that integrates all magnetic elements used in the proposed three-level resonant converter by using the magnetizing inductor as a resonant inductor. The experimental results are presented by conducting a theoretical analysis of a prototype with 350 W to 800 kHz.

Fault Detection and Isolation of Parallel Operation of Two Converters Using Zero Current Transformer Method (영상변류기 동작 방식을 이용한 2개의 컨버터 병렬 운전시 고장 탐지 및 분리)

  • 손승찬;성세진
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.5 no.4
    • /
    • pp.409-416
    • /
    • 2000
  • In case of operating two converters in parallel with ZCT operation method using one current sensor for fault tolerance by system characteristics, identifying fault detection and isolation is difficult of which converter is fault since the ZCT output is a difference of two converters' supply current when a converter has fault. This thesis suggest a fault detection and isolation method of converter in case of operating two converters in parallel for fault tolerant system and verified this suggested method through an experiment.

  • PDF

Analysis and Implementation of a DC-DC Converter with an Active Snubber

  • Lin, Bor-Ren;Lin, Li-An
    • Journal of Power Electronics
    • /
    • v.11 no.6
    • /
    • pp.779-786
    • /
    • 2011
  • This paper presents a soft switching converter to achieve the functions of zero voltage switching (ZVS) turn-on for the power switches and dc voltage step-up. Two circuit modules are connected in parallel in order to achieve load current sharing and to reduce the size of the transformer core. An active snubber is connected between two transformers in order to absorb the energy stored in the leakage and magnetizing inductances and to limit the voltage stresses across the switches. During the commutation stage of the two complementary switches, the output capacitance of the two switches and the leakage inductance of the transformers are resonant. Thus, the power switches can be turned on under ZVS. No output filter inductor is used in the proposed converter and the voltage stresses of the output diodes is clamped to the output voltage. The circuit configuration, the operation principles and the design considerations are presented. Finally, laboratory experiments with a 340W prototype, verifying the effectiveness of the proposed converter, are described.

A New Soft Switching DC-DC Converter using Two Transformers (두 개의 변압기를 이용한 새로운 소프트 스위칭 방식의 DC-DC 컨버터)

  • Lee Darl-Woo;Ahn Tae-Young
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.54 no.9
    • /
    • pp.444-449
    • /
    • 2005
  • This paper proposes the new soft switching DC-DC converter. We reported the experimental results of the new soft switching DC-DC converter. The proposed converter is to resonate between the leakage inductance of the transformer and the parasitic capacitances of the main switches for zero voltage switching. The voltage stresses of the two switches are the input voltage, it can improve the efficiency and a reduced height used two transformers. Theoretical analysis of the converter along with experimental results is provided. Finally, a 3.3V/20A prototype converter operation at 100kHz is built and experimental waveform verifies the analysis.

Analysis of an Interleaved Resonant Converter for High Voltage and High Current Applications

  • Lin, Bor-Ren;Chen, Chih-Chieh
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.5
    • /
    • pp.1632-1642
    • /
    • 2014
  • This paper presents an interleaved resonant converter to reduce the voltage stress of power MOSFETs and achieve high circuit efficiency. Two half-bridge converters are connected in series at high voltage side to limit MOSFETs at $V_{in}/2$ voltage stress. Flying capacitor is used between two series half-bridge converters to balance two input capacitor voltages in each switching cycle. Variable switching frequency scheme is used to control the output voltage. The resonant circuit is operated at the inductive load. Thus, the input current of the resonant circuit is lagging to the fundamental input voltage. Power MOSFETs can be turn on under zero voltage switching. Two resonant circuits are connected in parallel to reduce the current stress of transformer windings and rectifier diodes at low voltage side. Interleaved pulse-width modulation is adopted to decrease the output ripple current. Finally, experiments are presented to demonstrate the performance of the proposed converter.

Quasi-resonant Two-Inductor boost converter for PV-MIC (두 개의 인덕터를 갖는 PV-MIC용 준공진 부스트 컨버터)

  • Park, Seung-Won;Kim, Jae-Hyung;Kim, Jun-Gu;Ryu, Dong-Kyun;Kim, Tae-Hoon;Won, Chung-Yuen
    • Proceedings of the KIPE Conference
    • /
    • 2010.11a
    • /
    • pp.188-189
    • /
    • 2010
  • This paper proposed a new zero-voltage switching(ZVS) Two-Inductor boost converter. The conventional Two-Inductor boost converter has defect. When the switch is turned off, the high voltage spike is occurred in the switch by leakage inductance and switch parasitic capacitor. To solve this problem, the parallel resonant capacitor is added to the conventional Two-Inductor boost converter. Using quasi-resonant between parallel resonant capacitance and leakage inductance, the switches is operated soft switching. A reduction of transformer turn ratio is achieved by the voltage doubler rectifier.

  • PDF