두 개의 Microphone 배열 특성에 의한 음향 Intensity 측정 (Sound Intensity Measurement for Characteristics of Two Microphone Arrangements.)

  • 장호경
    • 한국음향학회:학술대회논문집
    • /
    • 한국음향학회 1985년도 학술발표회 논문집
    • /
    • pp.37-42
    • /
    • 1985
  • The errors caused by developmental finite difference approximations in the two microphone acoustic intensity measurement technique are considered in this paper. The frequencies and pressure responses obtained experimentally, are presented for both face to face (FF) and side by side(SS) microphone configurations. The implications of these results by the use of such a cofiguration for two microphone sound intensity measurement are discussed.

  • PDF

다수의 마이크를 이용한 관내 음향 변수의 직접 측정법 (Multiple Microphone Technique for a Direct Measurement of In-duct Acoustical Parameters)

  • 장승호;이정권
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2000년도 춘계학술대회논문집
    • /
    • pp.1661-1666
    • /
    • 2000
  • Nowadays, the two microphone method is accepted as the standard as specified in ASTM E1050-90 for measuring in-duct acoustic properties. However, research results on using the least square method with multiple measurement points and broadband excitation have been reported for enhancing the frequency response of the two microphone method. In this paper, the effects of varying the relative measurement positions on errors in the estimation of the acoustic quantities is studied for the multiple microphone method. Both of the theoretical and experimental results show that, among every possible sensor positioning configurations, the equidistant positioning of sensors yields the smallest error within the effective measurement frequency range. In addition, it is noted that the measurement accuracy can be increased and the effective frequency range can be widened by increasing the number of equidistant sensors. Measurement examples are shown and the results support the findings.

  • PDF

두개의 음향탐촉자를 이용한 소음기의 투과손실 측정과 오차해석 (Transmission Loss Measurement of Silencer with Two Microphones and Its Error Analysis)

  • 강성우;김양한
    • 소음진동
    • /
    • 제2권3호
    • /
    • pp.181-192
    • /
    • 1992
  • A method of measuring the transmission loss of silencer using two microphone technique is described. Two microphone methol is used to elliminate the measurement error due to reflected wave spectra in inlet/outlet duct of silencer. Errors associated with the measurement method are studied. Henceforth the methods to effectively supress the influence are presented. Based on these considertions, the appropriate procedure of experimental set-up to measure the transmission loss a silencer is described with experimental verifications.

  • PDF

차음재의 음향투과손실 측정에 Two-Microphone Impedance Tube Method의 적용과 한계 (The Limit and Application of Two-microphone Impedance Tube Method to the Sound Transmission Loss Measurement of Sound Isolation Materials)

  • 이승;안민홍;이동훈
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 춘계학술대회논문집
    • /
    • pp.883-888
    • /
    • 2002
  • This study describes the limit and application of the two-microphone impedance tube method to the sound transmission loss measurement of several sound isolation materials with different physical properties. For the sound isolation materials having small flexural rigidity, it is shown that the two-microphone impedance tube method is validated to practically measure the sound transmission loss. For the sound isolation materials having large flexural rigidity, on the other hand, it is found that the two-microphone impedance tube method is no longer valid to measure the sound transmission loss because the regions of resonance and mass law are moved into the higher frequencies. In addition, in order to accurately measure the sound transmission loss of sound isolation materials, their size should be decided based on the consideration of the effect of acoustic excitation on their vibration response.

  • PDF

차음시트의 음향투과손실 측정에 관한 연구 (A Study on the Sound Transmission Loss Measurement of Sound Isolation Sheets)

  • 이동훈;강문;이주원;정갑철;권영필
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2000년도 추계학술대회논문집
    • /
    • pp.409-414
    • /
    • 2000
  • A new impedance tube method is presented for the measurement of transmission loss of sound isolation sheets. The two-microphone method based on the sound decomposition theory proposed by Seybert and Ross is reviewed in this impedance tube method, which has been used for the determination of absorption coefficient of absorptive materials as well as transmission loss of automotive mufflers. Sound transmission losses for rubber, polyvinyl and asphalt sheets are measured in an impedance tube and reverberation room facility, respectively. By comparing two measurement methods, the reliability of impedance tube method used in this study is validated. From the experimental results, it is shown that the accuracy of sound isolation capability obtained by the impedance tube method depends upon the microphone spacing and the distance of the first microphone from the test sample surface.

  • PDF

음향 임피던스 측정을 위한 이중 마이크로폰 기법에 대한 고찰 (Note on the Two-Microphone Methods for the Measurement of Acoustic Impedance)

  • 서성현
    • 한국수소및신에너지학회논문집
    • /
    • 제29권2호
    • /
    • pp.163-169
    • /
    • 2018
  • The present article discusses about the measurement techniques of acoustic impedance that becomes one of the important acoustic characteristics of various boundaries found inside of propulsion systems. Acoustic characteristics including acoustic impedance and reflection coefficient can be often assessed and estimated by use of the two-microphone method. Theoretical expressions of acoustic impedance and reflection coefficient measured in an impedance tube are presented for both cases with mean flow and without flow, and the practical application of the method through calibration is also provided. The acoustic impedance and the reflection coefficient are related with axial locations of microphones, thermodynamic characteristics of gas inside, and the transfer function between the pressure wave measurements at multiple locations.

음향강도계측법에 의한 음향투과손실의 측정 및 표면진동 모우드의 예측에 관한 연구 (A study of transmission loss and surface vibration mode by the two microphone acoustic intensity method)

  • 김의간;남청도;전효중
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제11권1호
    • /
    • pp.63-71
    • /
    • 1987
  • The measuring of acoustic intensity has been investigated by many researchers and practicians during the last several decades. But due to the lack of measurement accuracy, they have had no practical use. In recent years, the two microphone acoustic intensity method has been developed by the advancement of FFT analysis technique and the digital data processing equipment. This new method of using two microphones gives informations on the noise source survey and the acoustic power of sound radiation source without the anechoic room. In this paper, theoretical formulae for the two microphone acoustic intensity method and the sound transmission loss are checked. The obtained results for the acoustical enclosure of gas heat pump were compared with the classical field incidence mass law. The surface vibration modes for a panel of enclosure were also estimated.

  • PDF

Measurement of the Sound Absorption Coefficient of Fiberboard by Two Microphone Method

  • Kang, Chun Won;Park, Hee Jun;Jeong, In Soo;Kim, Gwang Chul
    • Journal of the Korean Wood Science and Technology
    • /
    • 제33권5호통권133호
    • /
    • pp.45-49
    • /
    • 2005
  • The sound absorption coefficients of three types commercial fiberboard were experimentally measured under a relatively low frequency range of 50 to 1600 Hz by the two microphone transfer function method. The sound absorption coefficient of 30 mm thick fiberboard was higher than that of 18 mm thick fiberboard at the frequency range of 50 to 1.2 KHz. The sound absorption coefficient of medium density fiberboard was a little higher than that of low density fiberboard.

Development of a Practical Two-Microphone Impedance Tube Method for Sound Transmission Loss Measurement of Sound Isolation Materials

  • Ro, Sing-Nam;Hwang, Yoon;Lee, Dong-Hoon
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제11권3호
    • /
    • pp.105-113
    • /
    • 2003
  • This study developed a practical two-microphone impedance tube method to measure the sound transmission loss of sound isolation materials without the use of an expensive reverberation room or an acoustic intensity probe. In order to evaluate the validation and applicability of the two-microphone impedance tube method, sound transmission losses for several sound isolation materials with different surface density and bending stiffness were measured, and the measured values were compared with the results from the reverberation room method and the theory. From the experimental results, it was found that the accuracy of sound transmission loss obtained by the impedance tube method depends upon the diameter size of the impedance tube (i.e., tested sample size). For sound isolation materials having relatively large bending stiffness such as acryl, wood, and aluminum plates, it was found that the impedance tube method proposed by this study was not valid to measure the sound transmission loss. On the other hand, for sound isolation materials having relatively small bending stiffness such as rubber, polyvinyl, and asphalt sheets, the comparisons of transmission loss between the results from the impedance tube method and the theory showed a good agreement within the range of the frequencies satisfying the normal incidence mass law. Therefore, the two-microphone impedance tube method proposed by this study can be an effective measurement method to evaluate the sound transmission loss for soft sound isolation sheets having relatively small bending stiffness.

소음기 감음 성능 불확도 산출 방법 연구 (Application of the uncertainty for insertion loss measurement of silencers)

  • 유승국;김대현;김영찬;김두훈
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2000년도 춘계학술대회논문집
    • /
    • pp.1675-1680
    • /
    • 2000
  • Recently the uncertainty has been made rapid progress in various fields of industry but the uncertainty measurement method of acoustical test (i.e. Insertion loss, Absorption ratio, Transmission loss etc,) hasn't been established. In this study, the uncertainty of measurement method for ducted silencers is carried out according to ISO 7235. The standard uncertainty factors are composed of sound pressure level, microphone sensitivity and pistonphone calibration in this measurement. Sound pressure level is type A evaluation of uncertainty, microphone sensitivity and pistonphone calibration are type B evaluation of uncertainty. The combined standard uncertainty is calculated by two type evaluation. The expanded uncertainty is expressed by the combined standard uncertainty multiply k value which is yield the effective degree of freedom.

  • PDF