• Title/Summary/Keyword: Turn test

Search Result 670, Processing Time 0.031 seconds

One Year Longitudinal Study of the Relationship between Infants' Turn-Taking and Vocabulary Development (영아의 차례 맡기와 어휘발달 관계에 대한 단기 종단연구)

  • Kim, Myoung-Soon;Kim, Eui-Hyang;Lee, Yoo-Jin
    • Journal of the Korean Home Economics Association
    • /
    • v.50 no.2
    • /
    • pp.75-84
    • /
    • 2012
  • The purpose of this study was to examine the relationship between infants' turn-taking and vocabulary development during a one-year longitudinal study. Participants of this study included 46 infants who participated in both of the 1st and the 2nd tests. The infants' turn-taking frequencies were observed during mother-infant's free play for 10 minutes. The infants' vocabulary was investigated with MCDI-K for the 1st test and PRES for the 2nd test. The collected data were analyzed using both t-test and Pearson's correlation. The research results were as follows: First, the turn-taking frequencies and vocabulary of infants increased with age groups. Second, there was positive relationship between the turn-taking and the receptive vocabulary in group A at T1. Third, there were significant differences in receptive vocabulary at T1 and expressive vocabulary at T2 among group A according to the infants' turn-taking levels.

Estimation of the Through Car Equivalent for Left-Turn Movement According to the Left-Turn Curve Radius in the Signalized Intersection (신호교차로에서 곡선반경에 따른 좌회전의 직진환산계수 산정)

  • 오영태;김기형
    • Journal of Korean Society of Transportation
    • /
    • v.19 no.2
    • /
    • pp.21-28
    • /
    • 2001
  • This study is to estimate the through car equivalent for left-turn movement according to left turn radius in the signalized intersection. The saturation flow rate for left-turn movement in 92' KHCM(Korea Highway Capacity Manual) is the same as that for through movement in the signalized intersection where the left turn radius is over 20m. This study uses Duncan 'Test's Test in order to find out the saturated position for queued vehicle in the signalized intersection. It found that the saturated flow rate of left-turn movement in the signalized intersection is less than that of through movement where the left-turn radius is less than 20m. It found that the through car equivalents for left-turn movement according to left-turn radius(8m-20m) are between 1.05 and 1.14.

  • PDF

The Development of An Error Measurement System of 5-Axis Mill & Turn Machine Tool by Double Ball Bar Test (DBB를 이용한 5축 복합가공기의 오차 측정 시스템 개발에 관한 연구)

  • Kim T.H.;Jung Y.G.;Ko H.J.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.243-244
    • /
    • 2006
  • In this paper, the development of an error measurement system of 5-axis mill & turn machine tool presented by double ball bar test, which has been widely used to measure the overall accuracy of machining center. and the reliability of an error measurement system of 5-axis mill & turn machine tool was secured by the direct cutting test.

  • PDF

Development and Verification of Treatment Programs by Turn and Roll Types to Improve the Function of Vestibular System (전정기 기능 향상을 위한 회전과 구르기 훈련 프로그램의 개발 및 검증)

  • Park, Yang-Sun;Kang, Sung-Ho;Lim, Young-Tae
    • Korean Journal of Applied Biomechanics
    • /
    • v.22 no.2
    • /
    • pp.209-217
    • /
    • 2012
  • The purpose of this study was to develop a turn-type treatment program which applies the principle of spotting and a roll-type treatment program that induces off-vertical axis. 29 collegiate students volunteered for this study. 12-week treatment programs were applied to both 15 students for turn-type treatment group and 14 students for roll-type treatment group. As an analytic tool, eye camera was employed to verify the treatment programs for a stimulus upon a turn, recovery after a stimulus upon a turn, and nystagmus that affects a vestibular system. Two-way ANOVA with repeated measures was applied to see the significant differences between the treatment groups, and between the test periods. For Post-Hoc Test, paired t-test was used to within the group and independent t-test was used to between the groups. The results indicated that roll-type treatment training has maximized a stimulus on nystagmyus during the stimulus by a roll. Turn-type treatment training has maximized a stimulus on nystagmyus right after a stimulus by a roll and significantly decreased the intensity of nystagmyus during the recovery. Both turn and roll type treatments have reduced the recovery time which from nystagmyus to a normal status. Roll-type treatment has showed a much shorter recovery time for nystagmyus than the roll-type treatment has. Based on the results of treatment programs developed in this study, we expect the treatment programs can be applied to treat dizziness and to improve the function of vestibular system as a rehabilitation tool.

A miniaturized turn-counting sensor using geomagnetism for small-caliber ammunition fuzes (지구자기장을 이용한 소구경 탄약 신관용 소형 회전수 계수 센서)

  • Yoon, Sang-Hee;Lee, Seok-Woo;Lee, Young-Ho;Oh, Jong-Soo
    • Journal of Sensor Science and Technology
    • /
    • v.16 no.1
    • /
    • pp.17-23
    • /
    • 2007
  • This paper presents a miniaturized turn-counting sensor (TCS) where the geomagnetism and high-rpm rotation of ammunition are used to detect the turn number of ammunition for applications to small-caliber turn-counting fuzes. The TCS, composed of cores and a coil, has a robust structure with no moving part for increasing the shock survivability in the gunfire environments of ${\sim}30,000$ g's. The TCS is designed on the basis of the simulation results of an electromagnetic analysis tool, $Maxwell^{(R)}$3D. In experimental study, the static TCS test using a solenoid-coil apparatus and the dynamic TCS test (firing test) have been made. The presented TCS has shown that the induction voltage of $6.5{\;}mV_{P-P}$ is generated at the magnetic flux density of 0.05 mT and the rotational velocity of 30,000 rpm. From the measured signal, the TCS has shown the SNR of 44.0 dB, the nonlinearity of 0.59 % and the frequency-normalized sensitivity of $0.26{\pm}0.01{\;}V/T{\cdot}Hz$ in the temperature range of $-30{\sim}+43^{\circ}C$. Firing test has shown that the TCS can be used as a turn-counting sensor for small-caliber ammunition, verifying the shock survivability of TCS in high-g environments.

Ultimate Strength and Design Method of Turn-buckle for Measuring Tensile Force (인장력 측정용 턴버클의 극한강도 및 설계방법)

  • Lee, Swoo Heon;Shin, Kyung Jae;Lee, Hee Du
    • Journal of Korean Society of Steel Construction
    • /
    • v.25 no.1
    • /
    • pp.61-70
    • /
    • 2013
  • A turn-buckle is capable of adjusting the tensile force by left-hand threads and right-hand threads between tension members. There are different types of turn-buckles according to tension member and connection form but the practical and existing turn-buckles are incapable of measuring the tensile force. A turn-buckle for adjusting and measuring tensile force has therefore been developed. This study shows the ultimate strength and reliability for measurement of the new turn-buckles through finite element analysis of the developed ones. From analytic results of the new turn-buckles which have the measurement limit loads of 100kN, 200kN and 300kN, the ultimate strength is approximately five times stronger than the measurement limit capacity. Additionally, a review of the new turn-buckle, which has the measurement limit load of over 300kN, shows that there is a tendency for the size of turn-buckle to become larger. So the connection devices were designed and the loading test was conducted from the concept that the parallel connection of turn-buckle with 300kN capacity can measure the tensile force of 600kN. The results of parallel loading test show the sufficient possibility. Furthermore, the mock-up test was constructed to investigate the release of initial load and corrosion when the new turn-buckle is installed at the outdoor and exposed to rain and atmosphere.

Effectiveness of the Self-determination Theory based a Motivational Interviewing YOU-TURN Program for Smoking Cessation among Adolescents (자기결정성 이론 기반 동기면담 유턴 프로그램이 청소년 금연에 미치는 효과)

  • Ha, Young Sun;Choi, Yeon Hee
    • Journal of Korean Academy of Nursing
    • /
    • v.45 no.3
    • /
    • pp.347-356
    • /
    • 2015
  • Purpose: In this study, the effectiveness of a motivational interviewing smoking cessation YOU-TURN program for adolescents was examined. The program was based on the self-determination theory. Methods: The study was carried out with a nonequivalent control group pretest-posttest design. Participants in the present study were 136 high school students living in D city. The students were assigned to the experimental group (n=52) who participated in the motivational interviewing smoking cessation YOU-TURN program based on self-determination theory, or to the control group (n=84) who participated in a general smoking cessation program. Data were collected from September 1, 2013 through April 30, 2014. Collected data were analyzed using SPSS PC+ 21.0 with Chi-square test, Fisher's exact test, t-test, Mann-Whitney U test, Repeated Measures ANOVA, and MANOVA-Wilk's Lambda. Results: The experimental group had a significant increase in basic psychological needs, and duration of quitting-smoking in comparison with the control group. The experimental group had a significant decrease in cigarettes smoked per day and cotinine in urine in comparison with the control group. Conclusion: The motivational interviewing YOU-TURN program, when delivered to adolescents who smoked, was effective in discouraging smoking, and can be utilized as an effective nursing intervention for adolescents who smoke.

The Dielectric Characteristics of Turn-to-Turn Insulation for DC Reactor Type HTSFCL (DC reactor type 고온호전도 한류기의 턴간 절연 특성)

  • 백승명;정종만;이창화;류엔반둥;김상현
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.16 no.12S
    • /
    • pp.1299-1304
    • /
    • 2003
  • Fault current limiters (FCL) are extensively needed to suppress fault currents, especially for trunk power systems heavily connected to high voltage/large current transmission lines. Due to its ideal electrical behavior, high-temperature superconductor fault current limiter (HTSFCL) becomes one of the most important developing trends of limiters in power system. This paper describes the result of an investigation of the dielectric characteristics of turn-to-turn insulation for pancake and solenoid type reactor coil in liquid nitrogen. The influence of thickness in a variety length, on AC, DC and impulse surface flashover has been investigated. Also, the relationships between the number of turn and breakdown characteristics were clarified. The information gathered in this test series should be helpful in the design of liquid nitrogen filled DC reactor type HTSFCL.

Development of the U-turn Accident Model at Signalized Intersections in Urban Areas by Logistic Regression Analysis (로지스틱 회귀분석에 의한 도시부 신호교차로 유턴 사고모형 개발)

  • Kang, Jong Ho;Kim, Kyung Whan;Kim, Seong Mun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.34 no.4
    • /
    • pp.1279-1287
    • /
    • 2014
  • The purpose of this study is to develop the U-turn accident model at signalized intersections in urban areas. The characteristics of the accidents which are associated with U-turn operation at 3 and 4-legged signalized intersections was analyzed and the U-turn accident model was developed by regression analysis in Changwon city. First, in order to analyze the effectiveness on traffic accidents by U-turn installation, the difference of mean of traffic accident number are measured between two groups which are composed by whether or not U-turn installation the groups by Mann-Whitney U test. The result of significance test showed that intergroup comparison on mean by accident types made difference except rear-end accident type and by accident locations exit section only showed difference in significance level at 4-legged intersections, so the accident number have more where the U-turn is permitted than not. Response measures about the number of accidents were classified by whether accidents occurred and accident model were constructed using binomial logistic regression analysis method. The developed models show that the variables of conflict traffic, number of opposing lane are adopted as independent variable for both intersections. The variables of longitudinal grade for 3-legged signalized intersection and number of crosswalk for 4-legged signalized intersection at which the U-turn is permitted is adopted as independent variable only. These study results suggest that U-turn would be permitted at the intersection where the number of opposing lane is more than 3.5 each, the longitudinal grade of opposing road is upward flow and there is need to establish the U-turn traffic sign at signalized intersections.

Development of Shorted-Turn Diagnosis system for Generator Rotor Winding (발전기 회전자 권선의 층간단락 진단시스템 개발)

  • Lee, Yeong-Jun;Kim, Hui-Dong;Ju, Yeong-Ho
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.48 no.11
    • /
    • pp.742-747
    • /
    • 1999
  • On-line diagnosis system has been developed and is now applied the detection of shorted turns in the field winding of large generator. This system consists of data aquisition system and display PC. The data aquisition system detects voltage waveforms from flux probe sensor installed in the stator slot. The display PC shows theshorted-turn situation of generator rotor winding. A shorted-turn diagnosis test wasperformed on five gas turbine generators at the Seoinchon combined cycle power plant. The test was conducted using an new diagnosis system and digital oscilloscope which can identify the pole location, the slot number and the number of shorted turns within each slot. It is confirmed that results of two systems are very same in the field tests.

  • PDF