• Title/Summary/Keyword: Turbidity current

Search Result 95, Processing Time 0.025 seconds

Water Column Structure and Dispersal Pattern of Suspended Particulate Matter (SPM) in a floating ice-dominated fjord, Marian Cove, Antarctica during Austral Summer (유빙이 점유한 남극 마리안 소만의 하계기간 수층 구조와 부유물질 분산)

  • Yoo, Kyu-Cheul;Yoon, Hoo-Il;Kang, Cheon-Yun;Kim, Boo-Keun;Oh, Jae-Kyung
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.5 no.4
    • /
    • pp.295-304
    • /
    • 2000
  • Vertical measurement of CTDT at about 30 min intervals and spatial surface temperature, salinity, and concentration of suspended particulate matters were conducted to elucidate the character of water column and the dispersal pattern in a floating ice-dominated fjord, Marian Cove, West Antarctica. Marian Cove showed two distinct water layers in terms of turbidity; 1) cold, fresh, and turbid surface plume in the upper 2 m,2) warm, saline, and relatively clean Maxwell Bay inflow between 15-45 m in water depth. Thermal melting of Maxwell Bay inflow and tidewater glacier/floating ices developed the surface mixed layer and the activity of floating ices cause Maxwell Bay inflow to be unstable. Due to the unstable water column, the development of Maxwell Bay inflow and subsequent surface plume are not influenced by tidal frequency. Coastal current generated by strong northwesterly wind may extend warm, saline, and turbid surface plume into the central part of the cove along the northern coast via the western coast of Weaver Peninsula. Terrigenous sediments of meltwaters from the glaciated ice cliffs near the corner of tidewater glacier and some coasts enter into the cove and their dispersion depends upon the hydrographic regimes (tide, wind, wave etc.). At the period of spring tide, the strong wind stress with the northwesterly wind direction reserve suspended sediment-fed surface plume and so allow the possibility of deposition of terrigenous sediments within the basin of cove.

  • PDF

Evaluation of the Effect of Flocculator Rotation Direction in Floccualation Basin on Hydrodynamic Behavior using CFD (CFD를 이용한 플록큐레이터 회전방향에 따른 플록형성지 유동 평가)

  • Cho, Young-Man;Yoo, Soo-Jeon;Roh, Jae-Soon;Kim, taek-Jun;Kim, Chang-Won
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.31 no.5
    • /
    • pp.364-370
    • /
    • 2009
  • With time, the stable management of turbidity is becoming more important in the water treatment process. So optimization of flocculation is important for the improvement of the sedimentation efficiency. we evaluated the hydrodynamic behavior in the rotation direction (clock-wise, counterclock-wise) of the flocculator in the flocculation basin using Computational Fluid Dynamics (CFD). The results of the CFD simulation, in cases where flocculators rotate in a clockwise direction, a stronger flow is formed near the surface of the water where the rotating direction and current of flow correspond. The variance and standard deviation of the flux are about 8.5 and 2.9 respectively. In contrast, in the case of a counterclockwise direction, a stronger flow is formed near the bottom of the basin. The variance and standard deviation of the flux are about 5.3 and 2.3, respectively. The effluent flux is affected more by the third flocculator spin than the first and second flocculator spins. The third flocculator spinning in the counterclockwise direction is better for the uniform flow of the sedimentation basin than the third flocculator spinning in the clockwise direction

Long-term Changes of Fish Ecological Characteristics on the Gwanpyeong Stream Development and the Necropsy-based Health Assessments (관평천 개발에 따른 장기간 어류 생태적 특성 변화 및 해부학적 건강도 평가)

  • Oh, Ja Yun;Lee, Sang-Jae;An, Kwang-Guk
    • Korean Journal of Environment and Ecology
    • /
    • v.34 no.4
    • /
    • pp.282-293
    • /
    • 2020
  • This study investigated a long-term variation trend of water quality, fish compositions, and ecological health conditions in the Gwanpyeong stream located in the nearby Daejeon metropolitan city to understand the impact of urban development projects on the aquatic ecosystem. The sampling was made in four surveys (2009, 2010, 2016, 2019) before and after urbanization. The urban development was conducted in 2008, resulting in the stream's ecological disturbance, and the stream restoration was conducted in 2012. Thus, stream monitoring was conducted to analyze the ecological trends before and after the restoration. The multi-metric models for Fish Assessment Index(FAI) and necropsy-based Health Assessment Index(HAI) were applied in the fish community and organ-level, respectively, to assess the ecological health of the stream. Minimum turbidity and chlorophyll-a(Chl-a) occurred in the mid-stream(St. 2), and this was probably due to rapid current velocity in the riffle zone. We collected 18 fish species, and the dominant species was Zacco platypus (40.6%). In 2016 immediately after the stream restoration, the relative proportions of sensitive species and insectivore species were the highest along with highest values in the species diversity and species richness index, resulting in the best condition in the ecological health, based on FAI model values. However, the ecological health, based on the FAI, became worse in the latest survey conducted in 2019. The analysis of the HAI model based on the organ-level approach showed skin erosion in the fish of upper stream, kidney defects in downstream, and the liver and gill defects observed in all sites, indicating that the anatomical health was also affected.

Development of a Multifunctional Design Concept to Improve Constructed Wetland Performance (인공습지의 성능향상을 위한 다기능 설계기법 개발)

  • Reyes, N.J.D.G.;Choi, H.S.;Kim, L.H.
    • Journal of Wetlands Research
    • /
    • v.22 no.2
    • /
    • pp.161-170
    • /
    • 2020
  • Constructed wetlands (CWs) are widely used to solve water quality problems caused by diffuse pollution from agricultural areas; however, phytoplankton blooms in CW systems can occur due to long hydraulic retention time (HRT), high nutrient loading, and exposure to sunlight. This study was conducted to evaluate the efficiency of a CW designed to treat agricultural diffuse pollution and develop a design concept to improve the nature-based capabilities of the system. Monitoring was conducted to assess contribution of individual wetland components (i.e. water, sediments, and plants) in the treatment performance of the system. During dry days, the turbidity and particulates concentration in the CW increased by 80 to 197% and 10 to 87%, respectively, due to the excessive growth of phytoplankton. On storm events, the concentration of particulates, organics, and nutrients were reduced by 43% to 70%, 22% to 49%, and 15% to 69% due to adequate water circulation and constant flushing of pollutants in the system. Based on the results, adequate water circulation is necessary to improve the performance of the CW. Free water surface CWs are usually designed to have a constant water level; however, the climate in South Korea is characterized by distinct dry and rainy seasons, which may not be suitable for this conventional design. This study presented a concept of multifunctional design in order to solve current CW design problems and improve the flood control, water quality management, and environmental functions of the facility.

Rinsing Water Reduction in the Food (Kimchi) Industry (식품(김치)산업에서 세척수 사용량 절감에 관한 연구)

  • Yi, Hosang;Hyoung, Hoon;Choo, Kwang-Ho;Lee, Chung-Hak
    • Clean Technology
    • /
    • v.5 no.1
    • /
    • pp.78-85
    • /
    • 1999
  • In the Kimchi manufacturing industry that has recently been on its greatest growth, the rinsing process for salt-pickled Chinese cabbage in a brining step generates a vast amount of rinsing wastewater containing salts, colloids, and organics released from the raw material. In this study, the experimental method was developed to optimize the rinsing water consumption and thus to minimize the rinsing wastewater generation. The continuous counter-current rinsing basin in the actual plant was simulated through the lab-scale three batch-wise rinsing tanks. Rinsing efficiencies for the brined cabbage from the same brining tank were almost in the same level, whereas those varied substantially from source to source in the raw Chinese cabbage provided. When rinsing water used were decreased from 3.3 L/head to 2.7 L/head, no significant change was observed with respect to COD, turbidity, conductivity, $Na^+$, and $Cl^-$ concentrations in the extracted solution of the rinsed cabbage. However, the quality of the extracted solution was badly deteriorated as the amount of rinsing water used dropped down to below 2.7 L/head. The reduction of rinsing water up to 18% was proved to be possible without any negative effect on the quality of the product, Kimchi.

  • PDF

A Study on the Applicability of PDA Technique in the P-CAP System for T-P Removal of STP Effluent (하수처리장 방류수의 총인 제거를 위한 P-CAP 시스템에서 PDA 기법의 활용가능성에 대한 연구)

  • Choi, Choongho;Maeng, Sungkyu;Sim, Jaehwi;Choi, Jinho;Song, Kyungguen;Lee, Byungha;Cha, Hoyoung
    • Journal of Korean Society on Water Environment
    • /
    • v.28 no.5
    • /
    • pp.729-742
    • /
    • 2012
  • Recently, to using chemical coagulation process for T-P removal in STP effluent as tertiary treatment process is generalized in the country. The importance of analysis technique to save the treatment & maintenance cost during coagulation process is becoming more increased each day. Thus, it is necessary for the analysis technique during coagulation process to be presented well the characteristic of coagulation in field apply. There are a few analysis techniques such as Jar Test, zeta potential analysis and streaming current detecting techniques. But there are difficult to apply in field immediately due to long test time and difficult analysis techniques. And using PDA technique, it is reviewed applicability of the techniques as field index on pilot plant of P-CAP system The P-CAP system is composed of an in-line static mixer, a Flocculation Tank and the CAP reactor with 2 stage weir for effluent. Pre-test is performed to fix the mixing velocity in the Flocculation Tank using the PDA equipment and it fixed with 30RPM. Also, Jar Test is performed to select optimum dose of each coagulant for each T-P concentration level of influent. Result of continuous test on pilot plant of P-CAP system, the FSI in the Flocculation Tank is increased consistently by increasing each dosing concentration of coagulant such as LAS and PAC in the low level influent T-P concentration comparatively. It is considered that formed Al-hydroxide complexes for dosed coagulant are caused FSI variation. Furthermore, it seems that FSI value in the high level influent T-P concentration appeared lower than the opposite influent condition relatively because it is formed simultaneously Al-hydroxide complexes as solid type and Al-phosphorus complexes as soluble type. Thus, relation of FSI by PDA technique and T-P removal of final effluent on pilot plant of P-CAP system are very limited for the kind of coagulant and the characteristics of influent. And it though that FSI value by PDA technique with analyzing of turbidity in Flocculation Tank will be used restrictedly on field as the relative field-index.

Application of Automatic Stormwater Monitoring System and SWMM Model for Estimation of Urban Pollutant Loading During Storm Events (빗물 자동모니터링장치와 SWMM 모델을 이용한 강우시 도시지역 오염부하량 예측에 관한 연구)

  • Seo, Dongil;Fang, Tiehu
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.34 no.6
    • /
    • pp.373-381
    • /
    • 2012
  • An automatic flow and water quality monitoring system was applied to estimate pollutant loads to an urban stream during storm events in DTV (Daeduk Techno Valley), Daejeon, Korea. The monitoring system consists of rainfall gage, ultrasonic water level meter, water quality sensors for DO, temperature, pH, conductivity, turbidity and automatic water sampler for further laboratory analysis. All data are transmitted through on-line system and the monitoring system is designed to be controlled manually in the field and remotely from laboratory computer. Flow rates were verified with field measurements during storm events and showed good agreements. Automatic sampler was used to collect real time samples and analyzed for BOD, COD, TN, TP, SS and other pollutant concentrations in the laboratory. SWMM (Storm Water Management Model) urban watershed model was applied and calibrated using the observed flow and water quality data for the study area. While flow modeling results showed good agreement for all events, water quality modeling results showed variable levels of agreement. These results indicate that current options in the SWMM model to predict pollutant build up and wash-off effects are not sufficient to satisfy modeling of all the rainfall events under study and thus need further modification. This study showed the automatic monitoring system can be used to provide data to assist further refinement of modeling accuracy. This automatic stormwater monitoring and modeling system can be used to develop basin scale water quality management strategies of urban streams in storm events.

Desalination of Traditional Soy Sauce Using Electrodialysis (전기투석에 의한 재래식 간장의 저염화)

  • Chung, Jae-Ho;Mok, Chul-Kyoon;Lim, Sang-Bin;Woo, Gun-Jo;Baek, Hyung-Hee;Park, Young-Seo
    • Korean Journal of Food Science and Technology
    • /
    • v.34 no.5
    • /
    • pp.811-817
    • /
    • 2002
  • Korean traditional soy sauce was desalted using electrodialyzer, and their physicochemical properties were analyzed. The salt content of soy sauce significantly decreased from initial 18.9 (w/v) to 0.47% (w/v) and the volume also decreased to 330 mL when 1,000 mL of soy sauce was desalted for 450 min at a current of 2 A. During the desalting process, the numbers of viable cells of total bacteria, yeasts, and molds increased due to the concentration effect of the electrodialysis. Turbidity increased from 3.1 to 8.5, and total nitrogen, total sugar, and reducing sugar contents also increased. The pH, and amino nitrogen and volatile base nitrogen contents slightly decreased, with ammonia content significantly decreasing from 19.4 to $1.3\;{\mu}mol/mL$. Free amino acids content increased twofold after electrodialysis. Gas chromatograms of soy sauce showed that profiles of the flavoring compounds did not change when electrodialyzed for 360 min, but most were removed after 540 min.

Water Environments and Species Compositions of Phytoplankton at the Depths during Summer in the Coast of Dokdo, Korea (하계 독도연안의 수심별 수환경과 식물플랑크톤의 종조성 변화)

  • Kim, Mi-Kyung;Park, Jung-Won
    • Korean Journal of Environmental Biology
    • /
    • v.27 no.1
    • /
    • pp.48-57
    • /
    • 2009
  • The characteristics of physico-chemical factors and the species compositions of phytoplankton were investigated to analyze the marine ecosystem at the depths during summer in the coast of Dokdo (stations DOK1$\sim$3). The mean values of conductivity (32 mS cm$^{-1}$), total dissolved solids (45 mg L$^{-1}$), salinity (35.5 psu), total suspended solids (39 mg L$^{-1}$) were the highest in DOK1. The biomass (chl-${\alpha}$) of phytoplankton was the highest in the surface of station DOK1 (3.1 ${\mu}g$ L$^{-1}$). By means of physico-chemical factors (salinity, turbidity, chl-${\alpha}$, T-N, T-P and Si), the coast of Dokdo was estimated to be more polluted than the previous results in 2000. A total of 72 species in Dokdo were composed of 54 species (76.1%) for Bacillariophyceae and 13 species (18.3%) for Dinophyceae, 3 species (4.2%) for Chrysophyceae and 1 species (1.4%) for Cyanophyceae. The standing crops of phytoplankton were the highest (8.5 $\times$ 10$^4$ cells L$^{-1}$) at 20 m of station DOK1, while they were the lowest (1.65 $\times$ 10$^4$ cells L$^{-1}$) at 30 m of station 1. The dominance index was maximum (0.73) at 10 m of station DOK1 and was minimum (0.4) at 30 m of station 1. The diversity index was the highest (2.92) in the surface of station 2, while it was the lowest at 20 m (1.58). The dominant species of phytoplankton were Chaetoceros affinis (3.3 $\times$ 10$^4$ cells L$^{-1}$) at 20 m, Climacosphenia moniligera (2.8 $\times$ 10$^4$ cells L$^{-1}$) at 40 m and Melosira juergensii (1.7 $\times$ 10$^4$ cells L$^{-1}$) at 10 m of station DOK1. At the surface of station DOK2, the dominant species were Bacillaria paxillifer and Richelia intracellularis (1.4 $\times$ 10$^4$ cells L$^{-1}$, respectively), while it was Paralia sulcata (1.6 $\times$ 10$^4$ cells L$^{-1}$) at the surface of station DOK3. The station DOKl, where affected by upwelling, turbulence and convection due to the East Korean Warm Current, was the most eutrophicated water body in three stations. The monitoring of marine ecosystem in the coast of Dokdo should be continued to show the alternatives for water and species conservation and to purify the eutrophicated water body due to artificial pollutants as well as physico-chemical factors by the global warming, the climatic change, CO$_2$ etc.

About Streptococcosis of Cultured Olive Flounder, Paralichthys olivaceus in South Korea (국내 양식 넙치에서 발생하는 연쇄구균병에 관하여)

  • Lee, Nam-Sil;Min, Eunyoung;Kim, Kwang Il;Choi, Hye Sung;Jung, Sung-hee;Cho, Miyoung
    • Journal of Marine Life Science
    • /
    • v.5 no.1
    • /
    • pp.1-8
    • /
    • 2020
  • This review is about current Streptococcosis of cultured olive flounder, Paralichthys olivaceus, in South Korea. The main bacterial species are Streptococcus iniae, S. parauberis and Lactococcus garvieae. The occurrence trend has been arranged with published data and seed bank (NIFS) data that was examined with deposited strains and the number from 2002 to 2017. S. iniae and L. garvieae were collected until 2012 and 2002, respectively, but not collected any more after that year. In recent years, the dominant strain of Streptococcosis of cultured olive flounder is S. parauberis. The phenotypic and genetic characteristics of standard strains and isolated strains were examined with published paper. Notably, we describe about distinguishing gross signs and histological signs of 3 types of Streptococcosis in this report. White turbidity of eye, hemorrhage, enteritis and ascites are main signs of S. iniae infection. Darkness of body surface, hemorrhage in somatic muscle and pericarditis are predominant in occasion S. parauberis infection. In occasion of L. garvieae infection, common signs of Streptococcosis are revealed, but these are weak tendency compared with the previous two cases.