• 제목/요약/키워드: Tunnel pollutants

검색결과 49건 처리시간 0.028초

도시철도 객실 공기정화장치(SCAP)의 운행차량 효율평가 (Efficiency Evaluation of Operating Railroad with Subway Cabin Air Purifier)

  • 권순박;박덕신;조영민;김종범;조관현;남궁석;이주열;김태성
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2011년도 정기총회 및 추계학술대회 논문집
    • /
    • pp.1303-1308
    • /
    • 2011
  • In the modern society various types of transportation mode are utilized, among them the subway system is the one of the main transportation mode which more than 7.21 million people ride a day. Because of interests on the indoor air quality (IAQ) of underground public facilities, concerns on IAQ of subway system by many people are increasing. There are several approach to improve IAQ of subway station, such as installing platform screen door (PSD), frequent tunnel washing-out, and etc, however there has not been any attempt to improve IAQ of subway cabin inside. Most technologies for removing airborne particulate matters are known to be difficult to adopt on the subway cabin since the problem of maintenance cost. Therefore, the ultimate object of this study is a practical development of cabin air cleaning system which can reduce the concentration of airborne particles and harmful gases at the same time. The subway cabin air purifier (SCAP) was developed for removing particulate matters and gases pollutants inside a cabin. The whole system was designed and the roll-filter device was manufactured based on numerical prediction results. It is expected that SCAP could reduce indoor air pollutants in the subway cabin practically and it can be applied to other part of transportation vehicles.

  • PDF

Comparison of Mutagenic Activities of Various Ultra-Fine Particles

  • Park, Chang Gyun;Cho, Hyun Ki;Shin, Han Jae;Park, Ki Hong;Lim, Heung Bin
    • Toxicological Research
    • /
    • 제34권2호
    • /
    • pp.163-172
    • /
    • 2018
  • Air pollution is increasing, along with consumption of fossil fuels such as coal and diesel gas. Air pollutants are known to be a major cause of respiratory-related illness and death, however, there are few reports on the genotoxic characterization of diverse air pollutants in Korea. In this study, we investigated the mutagenic activity of various particles such as diesel exhaust particles (DEP), combustion of rice straw (RSC), pine stem (PSC), and coal (CC), tunnel dust (TD), and road side dust (RD). Ultra-fine particles (UFPs) were collected by the glass fiber filter pad. Then, we performed a chemical analysis to see each of the component features of each particulate matter. The mutagenicity of various UFPs was determined by the Ames test with four Salmonella typhimurium strains with or without metabolic activation. The optimal concentrations of UFPs were selected based on result of a concentration decision test. Moreover, in order to compare relative mutagenicity among UFPs, we selected and tested DEP as mutation reference. DEP, RSC, and PSC induced concentration-dependent increases in revertant colony numbers with TA98, TA100, and TA1537 strains in the absence and presence of metabolic activation. DEP showed the highest specific activity among the particulate matters. In this study, we conclude that DEP, RSC, PSC, and TD displayed varying degrees of mutagenicity, and these results suggest that the mutagenicity of these air pollutants is associated with the presence of polycyclic aromatic hydrocarbons (PAHs) in these particulate matters.

A PRELIMINARY STUDY OF EFFECT OF THE GREEN FEATURE - WING WALLS ON NATURAL VENTILATION IN BUILDINGS

  • Cheuk Ming Mak;Jian Lei Niu;Kai Fat Chan
    • 국제학술발표논문집
    • /
    • The 1th International Conference on Construction Engineering and Project Management
    • /
    • pp.814-819
    • /
    • 2005
  • There is growing consciousness of the environmental performance of buildings in Hong Kong. The Buildings Department, the Lands Department and the Planning Department of the Hong Kong Government issued the first of a series of joint practice notes [1] to promote the construction of green and innovative buildings. Green features are architectural features used to mitigate migration of noise and various air-borne pollutants and to moderate the transport of heat, air and transmission of daylight from outside to indoor environment in an advantageous way. This joint practice note sets out the incentives to encourage the industry in Hong Kong to incorporate the use of green features in building development. The use of green features in building design not only improves the environmental quality, but also reduces the consumption of non-renewable energy used in active control of indoor environment. Larger window openings in the walls of a building may provide better natural ventilation. However, it also increases the penetration of direct solar radiation into indoor environment. The use of wing wall, one of the green features, is an alternative to create effective natural ventilation. This paper therefore presents a preliminary numerical study of its ventilation performance using Computational Fluid Dynamics (CFD). The numerical results will be compared with the results of the wind tunnel experiments of Givoni.

  • PDF

서울시 지하철 시스템 내의 입자상물질(PM10, PM2.5) 농도 특성 (Concentration and Properties of Particulate Matters (PM10 and PM2.5) in the Seoul Metropolitan)

  • 이태정;임효지;김신도;박덕신;김동술
    • 한국대기환경학회지
    • /
    • 제31권2호
    • /
    • pp.164-172
    • /
    • 2015
  • Seoul subway plays an important part for the public transportation service in Seoul metropolitan area. As the subway system is typically a closed environment, frequent air pollution problems occurred and passengers get malhealth impact. Especially particulate matters (PM) is well known as one of the major pollutants in subway environments. The purpose of this study was to compare the concentrations of $PM_{10}$ and $PM_{2.5}$ in the Seoul subway system and to provide fundamental data in order to management of subway system. $PM_{10}$ and $PM_{2.5}$ samples were collected in the M station platform and tunnel of Subway Line 4 in Seoul metropolitan and in an outdoor location close to it from Apr. 21, 2010~Oct. 27, 2013. The samples collected on teflon filters using $PM_{10}$ and $PM_{2.5}$ mini-volume portable samplers and PM sequential sampler. The PM contributions were $48.6{\mu}g/m^3$ (outdoor), $84.6{\mu}g/m^3$ (platform) and $204.8{\mu}g/m^3$ (tunnel) for $PM_{10}$, and $34.6{\mu}g/m^3$ (outdoor), $49.7{\mu}g/m^3$ (platform) and $83.1{\mu}g/m^3$ (tunnel) for $PM_{2.5}$. The $PM_{10}$ levels inside stations and outdoors are poorly correlated, indicating that $PM_{10}$ levels in the metro system are mainly influenced by internal sources. In this study, we compared PM concentrations before and after operation of ventilation and Electrostatic Precipitator (EP). Despite the increased PM concentration at outdoor, $PM_{10}$ concentration at platform and tunnel showed the 31.2% and 32.3% reduction efficiency after operation the reduction system. The overall results of this study suggest that the installation and operation of the ventilating system and EP should have served as one of the important components for maintaining the air quality in the subway system.

5678 서울도시철도 지하역사의 라돈 관리 현황 (Current Status of Radon Management in the 5678 Seoul Metropolitan Rapid Transit Subway)

  • 김준현;윤현식;서강진;우희영;김만화;박종헌
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2011년도 춘계학술대회 논문집
    • /
    • pp.1306-1312
    • /
    • 2011
  • Underground Subway station's air pollutants are introduced from the indoor or outdoor. And Radon is a major pollutant in the subway station. Radioactive substances Radon is occuring naturally in granite tunnel wall and underground water. Especially inert gas Radon that causes lung cancer in human is anywhere but 5678 S.M.R.T. tunnels deep and pass through the granite plaque have a lot of Radon. The Radon concentration is determined by the following reasons : radon content of soil and concrete, underground water, ventilation, pressure difference, building structure, temperature, etc. So Radon concentration is hard to predict. And we can't only ventilate owing to era of high oil prices. This study focuses on our efforts for the reduction of Radon concentration. And the purpose is to provide basically datas of specially managed 15 subway station's Radon concentration.

  • PDF

도시철도 객실 공기질 평가모델 개발 (Development of Air Quality Assessment Model for Subway Cabin)

  • 권순박;조영민;박덕신;김세영;박재형;조관현;유건종;김정수
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2010년도 춘계학술대회 논문집
    • /
    • pp.157-160
    • /
    • 2010
  • Management of indoor air quality of underground subway station is an important issue since the limited natural ventilation, limited sunshine incoming, and highly moistured atmosphere. The improvement in IAQ of platform is expected because most stations were installed with platform screen door currently, however, the poor air quality in tunnel might be affecting subway cabin indoor. In this study, we developed the air quality assessment model based on computational fluid dynamics. The geometry of air ventilation unit, seat, LCD monitors, and passengers were modeled using commercial software (Design Modeler) and fluid pattern and pollutants trajectories were analyzed by using CFX. We predicted the thermal comfort by predicted mean vote (PMV), distribution of CO2 and PM10 concentration. It is expected that this model can be used for the performance test of air cleaners which are under development.

  • PDF

미국 디젤기관차의 매연 배출기준과 비교한 국내 디젤기관차의 매연 배출 저감목표 설정 연구 (Study on the Establishment of Reduction Goals for Air Pollutants Emissions from Diesel Locomotives in Korea by Comparison with Emission Regulation in United States)

  • 박덕신;권순박;임인권;조영민
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2006년도 추계학술대회 논문집
    • /
    • pp.152-157
    • /
    • 2006
  • The air pollutant emission from the railroad diesel locomotive is still a significant environmental concern in many countries including Korea and Unites States. The emission characteristics of the railroad diesel locomotive were extensively studied in this study. Particulate matter (PM) and nitrogen oxides ($NO_x$) emitted from a large locomotive engine (2-cycle, 16-cylinder, and 3,000-horsepower) under various engine-rating conditions was analyzed with a scanning mobility particle sizer and a gas stack sampler by using a dilution tunnel. We could gain the emission values of 2.1 g/horsepower-hour for PM and 42.7 g/horsepower-hour for $NO_x$. We proposed the emission reduction goal of the railroad diesel locomotive for Korea in comparison with the regulation of United States.

  • PDF

디젤 입자상물질의 특성 및 측정 평가에 관한 연구 (Study on Characteristics of Diesel Particualte Matter and it's Measurement and Evaluation)

  • 김복윤;이상권;조영도
    • 터널과지하공간
    • /
    • 제6권1호
    • /
    • pp.48-56
    • /
    • 1996
  • Presently, mobile diesel equipments contribute a lot to improve the economic feasibility of underground mining and tunneling operations. Even in Korea, a lot of diesel equipments are being applied to the undergroud workings already, but the technology of management and control of them is not sufficient yet. This study handled the production procedure, characteristics and evaluation technology on diesel particulate matte(DPM) which is known as a carcinogen. For easy measurement of DPM using laser dust monitor, conversion known as a carcinogen. For easy measurement of DPM using laser dust monitor, conversion factor(k) to gravimetric concentration has been acquired. It is appeared that the critical material among the diesel exhaust pollutants is becoming DPM instead of NOx from this year of 1996 according to the Government regulation.

  • PDF

서울시 지하역사 실내오염물질 농도자료의 통계분석을 통한 실내공기질 특성 평가 (Evaluation on Indoor Air Quality by Statistical Analysis of Indoor Air Pollutants Concentration in a Seoul Metropolitan Underground Railway Station)

  • 임봉빈;이규성;김주인;홍현수;김장원;조경호;정을규;김인규;안연순
    • 한국대기환경학회지
    • /
    • 제30권3호
    • /
    • pp.233-244
    • /
    • 2014
  • The objective of this study was to explore the characteristics of concentration of indoor air pollutants, such as $PM_{10}$, $CO_2$, and $NO_2$, measured by tele-monitoring system in a Seoul Metropolitan underground railway station from January 1, 2008 to December 31, 2012. The annual average concentration of indoor air pollutants actually varied over a wide range and was found to exhibit marked variation with time and measurement sites (tunnel inlet, platform, and concourse). After installing platform screen doors, the average $PM_{10}$ concentration on platform and concourse was decreased by 43.8% and 31.2%, respectively during the study periods. The relationship between the concentration of $PM_{10}$ and meteorological parameters (relative humidity and rainfall) or the Asian dust events was regarded as statistically significant. The correlations between the number of boarding/alighting passengers and $PM_{10}$, $CO_2$, and $NO_2$ were calculated. A p-value of less than 0.01 was regarded as significant except $NO_2$. The I/O ratio of $PM_{10}$ concentration was elevated after a congested time (about 08:00 am). The average I/O ratios of $NO_2$ were observed in concourse and platform on 03:00 am with $1.76{\pm}0.91$ and $1.50{\pm}0.51$, respectively. The average daily variation of standard excess rate of $PM_{10}$ and $NO_2$ concentration in concourse and platform was investigated. The highest standard excess rate was observed on 21:00 (09:00 pm).

나노버블을 이용한 지하철용 전기집진기 포집먼지에 대한 세척효율 평가 (Evaluation of Washing Efficiency of Collective PM by Electrostatic Precipitator in Subway Station Using Nano Bubble)

  • 이형돈;이승환;박찬규
    • 청정기술
    • /
    • 제26권1호
    • /
    • pp.13-21
    • /
    • 2020
  • 지하역사 내 대기오염물질은 외부에서 유입되거나 또는 지하철 내부의 승객 승·하차 시 발생하는 등 여러 가지 요인에 의해 복합적으로 발생한다. 최근 연구 결과에 따르면, 지하역사 내 터널 및 지하철역에서 발생하는 대부분의 대기오염물질은 열차풍에 의해 발생되는 것과 같이 내부적 요인에 많은 영향을 많이 받는 것으로 알려져 있다. 이러한 대기오염물질을 제어하기 위해서는 지하철역사 내에 전기집진장치와 같은 집진시설이 필요하며, 집진장치에 의해 제거된 미세먼지를 보다 효율적으로 관리하기 위해서는 집진장치 내부에 지속적인 세척이 필수적이다. 따라서 본 연구에서는 지하역사에 설치할 전기집진장치 내부 집진판에 쌓인 미세먼지를 세척하기 위한 나노버블세척 장치를 개발하였고 나노버블수의 먼지세척효율을 평가하고자 하였다. 실험 결과, 분사압 증가에 따라 세척 효율이 일정하게 증가하였고 나노버블수로 세척할 경우 수돗물로 세척한 경우보다 부착먼지 제거효율이 130.8% 더 증가하였다. 세척횟수 증가에 따라 최대 제거효율은 수돗물에 비해 143.1% 높았지만 적합한 세척횟수는 3회 미만인 것으로 나타났다. 또한 나노버블수 체류시간 변화에 따른 세척효율 실험결과, 나노버블수의 최대 체류시간은 5분 이내로 유지됨을 확인하였다.