• Title/Summary/Keyword: Tubes

Search Result 3,118, Processing Time 0.031 seconds

Evaluation of Forming Performance of Cold Rolled Steel Pipes & Tubes for Building Structure (건축구조용 냉간성형 강관의 가공성능 평가)

  • Im, Sung Woo;Choi, Kwang;Chang, In Hwa
    • Journal of Korean Society of Steel Construction
    • /
    • v.16 no.1 s.68
    • /
    • pp.33-42
    • /
    • 2004
  • Making use of SN steel in the building structure should be a prerequisite to adopt the design strength of said steel. As a preceding study, the material properties of STKN400B/490B tubes and SPAP235/325 and SPAR295 square pipes manufactured using SN400B/490B plates were evaluated. Compared with the yield and ultimate strengths of SN400B/490B plates, those of STKN400B/490B tubes increase. Nonetheless, the yield and ultimate strengths of STKN400B/490B tubes satisfied the design codes of STKN400B/490B tubes even though the tubes were fabricated via roll bending or press forming. On the other hand, the yield and ultimate strengths at the edges of SPAP235/325 square pipes did not satisfy the design codes based on the values at the sides. The maximum tensile and compressive residual stresses at the SN490B tube were equal to and 40% of the yield strength of the SN490B plate, respectively, In the case of the SPAP325 square pipe, both the maximum tensile and compressive residual stresses were 80% of the yield strength of the SN490B plate. The axial compressive loaded column test results snowed that the buckling strengths were not very different regardless of the mode of fabrication of STKN490B tunes. i.e., through roll bending or press forming. On the other hand, the buckling strength of the SPAP325 square pipe was higher than that of the built-up square pipe.

The Motility of Esophagus in Acute Hemorrhage (급성실혈시의 식도운동)

  • Park, Soon-Il;Shin, Dong-Hoon
    • The Korean Journal of Physiology
    • /
    • v.6 no.2
    • /
    • pp.39-48
    • /
    • 1972
  • Two polyethylene tubes were inserted into the esophagus of anesthetized rabbit in order to record the fluctuation of the intraluminal pressure through the orifices located near the tips of the tubes. The orifice of the first tube was 10 cm apart from the incisor of the rabbit and the orifice of the second tube was 5 cm below that of the first one. The tubes were filled with saline solution running at various rates ranging from 1.5 ml/min. to 4.2 ml/min. The tubes were connected to the pressure transducers and the electrical signals were recorded by the physiograph. When the peristaltic wave approached to the orifice a rise in the pressure was recorded, returning to the base line when the portion of the orifice was quiescent. The frequency of the peristaltic motion and the velocity of the wave were studied in connection with the flow rate of saline solution through the tubes and in the case of massive acute hemorrhage. The results obtained were as follows: 1. There was reflux of fluid induced during the procedure of the experiment. This outwrad flow through the pharynx seemed to elicite swallowing reflexes. Accordingly, the frequency of peristalsis of the esophagus was largely dependent on the flow rate of the fluid through the inserted tubes. By the flow rate of 1.5 ml/min., 2.5 ml/min., or 4.2 ml/min., the frequencies of the peristalsis were revealed to be $8.6{\pm}3.6/10min.,\;14.5{\pm}4.8/10min.\;or\;21.1{\pm}6.3/10min.,$ respectively. The velocity of peristalsis also coincided with the enhanced motility of the esophagus, showing $6.6{\pm}1.5\;cm/sec.,\;8.9{\pm}3.9\;cm/sec.,\;or\;12.4{\pm}4.6\;cm/sec.,$ respectively. 2. By acute hemorrhage, amounting to 2% of the body weight, the frequency of the peristalsis increased to twofold of the control and the propagation velocity also increased by 52 percent. 3. Retransfusion of the shed blood resulted in divergent responses. In some cases there were noticable ameliorations of the effects brought by acute hemorrhage, and in the others there were still increasing tendenies of the motility after the transfusion. 4. Some speculation was made about the possibility of a kind of relationship between the irreversibility of the hemorrhagic shock and the absence of responses by transfusion. 5. The peristalsis persisted even after complete disconnection at the midportion of the esophagus, reaffirming the view of a central regulation of the spatiotemporally coordinated motility, peristalsis.

  • PDF

Angled Capillary Method for Determining Erythrocyte Sedimentation Rate of Goat (경사모세관법(傾斜毛細管法)에 의한 산양혈액(山羊血液)의 적혈구침강율(赤血球沈降率) 측정(測定))

  • Shin, Sung-shik;Lee, Bang-whan;Shin, Jong-uk
    • Korean Journal of Veterinary Research
    • /
    • v.26 no.1
    • /
    • pp.187-194
    • /
    • 1986
  • The purpose of this study is to develop a new method which enables the goat ESR to be used as an effective clinical test. Blood samples were taken from 61 Korean native goats aged above one year old and the effect of tube inclinations, tube bores, tube lengths, environmental temperatures during tests and packed erythrocyte volumes (PCV) on the ESR were observed. The results were summarized as follows. 1. The ESR/hr using capillary hematocrit tube (Micro-Ht-tube) was gradually increased as the tube angle inclined from 90 (vertical) to 15 degrees and the best angle in view of both security and fast sedimentation rate was found to be an angle of 45 degrees. 2. The 45-degree angled ESR ($45^{\circ}$-ESR) increased as the diameter of tube bore decreased. 3. The tube length did not affect the $45^{\circ}$-ESR in percent. 4. The $45^{\circ}$-ESR increased with the increased environmental temperature during the ESR test. 5. The heparinized Micro-Ht tubes did not affect the $45^{\circ}$-ESR of EDTA-blood in healthy group but in anemic group. In the anemic group, the ESRs by the heparinized Micro-Ht-tubes were slightly higher than those by non-heparinized Micro-Ht-tubes. 6. By using the autologous plasma, PCV of the blood was adjusted to be 10, 20, 30, 40 and 50ml/100ml and $45^{\circ}$-ESRs were determined in the Micro-Ht-tubes. The $45^{\circ}$-ESRs increased as the values of PCV decreased. The regression of the $45^{\circ}ESR$ to PCV was curvilinear with the second degree polynomial, $Y=42.1838-1.7355X+0.0180X^2$(r=0.9997). 7. The $45^{\circ}$-ESR/hr, using non-heparinized Micro-Ht-tubes at $20^{\circ}C$, was determined in 35 healthy Korean native goats. The average PCV was $30.6{\pm}1.4ml/100ml$. The observed ESR values averaged $6.8{\pm}1.7%$ and the corrected ESR values to the standard PCV of 31ml/100ml averaged $6.5{\pm}1.2%$. From these results, the angled capillary tube method was found to be desirable ESR test of goat blood in which EDTA-blood is filled in nonheparinized Micro-Ht-tubes held at an angle of 45 degrees for an hour at $20^{\circ}C$.

  • PDF

Drug Adsorption Behavior of Polyolefin Infusion Tube Compared to PVC and PU (Non-PVC(폴리올레핀) 수액용 튜브 내면에서의 약물흡착 거동 - PVC 및 PU 수액튜브와의 비교)

  • Park, Kang Hoon;Park, Chang Kyu;Park, Jong;Jeon, Seungho;Bang, Sa-Ik;Kim, Ji-Heung;Chung, Dong June
    • Polymer(Korea)
    • /
    • v.38 no.3
    • /
    • pp.333-337
    • /
    • 2014
  • PVC (polyvinyl chloride) intravenous fluid bags and tubes that contain DEHP (diethylhexyl phthalate) as a plasticizer have several associated disadvantages for intravenous injections. We investigated the drug absorption behaviors on the inner surface of an infusion tube that consisted of commercialized PVC/PU (polyurethane). We developed a non-PVC (polyolefin) tube in order to improve the efficacy of this drug administration method. We prepared four types of non-PVC (polyolefin) infusion tubes using a polyethylene (PE), polypropylene (PP), syndiotactic 1,2-polybutadiene (PB), and styrene-ethylene (SE) copolymer elastomers were prepared using a single screw extruder. The four types of manufactured non-PVC (polyolefin) infusion tubes had good mechanical properties that were equivalent to PVC tube properties. The four types of prepared non-PVC (polyolefin) infusion tubes also prohibited drug absorption when compared to the commercialized PVC and PU tubes. Therefore, based on the results of this study, prepared non-PVC (polyolefin) tubes are good candidates for infusion because they prevent drug absorption and the release of DEHP.

Development and Characterization of the Electromagnetic Acoustic Transducer for Tubes (튜브탐상용 EMAT 제작 및 특성조사)

  • Ahn, Bong-Young;Lee, Se-Kyung
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.5 no.2
    • /
    • pp.42-48
    • /
    • 1986
  • Electromagnetic - Acoustic Transducers for the inspection of tubes were developed using permanent magnets and induction coils. The propagation velocity of ultrasonic waves in a tude wall was measured by the transducers. The position of a flaw in a tube and the relative size of flaws with different size were measured.

  • PDF

CCFL Backlight characterization using luminance meter and image analysis.

  • Gibour, Veronique;Boher, Pierre;Leroux, Thierry
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.791-794
    • /
    • 2004
  • In this article, we present a method to measure precisely the performances of direct-lit CCFL backlights using a luminance meter and dedicated image analysis software. The array of CCFL tubes alone can be measured directly and the luminance of each tube can be extracted along its main dimension. So, comparison of the different tubes on the same backlight can be made easily and the performances in terms of backlight uniformity improved. The influence of the diffuser sheet can be probed in the same way and the homogeneity of the entire surface of the backlight can be automatically extracted and quantified.

  • PDF

A High Aperture Ratio TFT Design for Bottom Emission Type AMOLED

  • Chien, Yao Hong;Huang, Jack
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.711-714
    • /
    • 2004
  • A new design for improving the aperture ratio of bottom emission type AMOLED is investigated. In conventional, the TFT of AMOLED fabrication method is "Etch Stopper (7-mask)", so the aperture ratio is limited in 28${\sim}$33% by Cs(Storage Capacitor). A high aperture ratio TFT is designed by using BCE(Back Channel Etching 5-mask) fabrication way and the aperture ratio is up to 40% shown in 2.2"AMOLED display.

  • PDF

Stresses in FGM pressure tubes under non-uniform temperature distribution

  • Eraslan, Ahmet N.
    • Structural Engineering and Mechanics
    • /
    • v.26 no.4
    • /
    • pp.393-408
    • /
    • 2007
  • The effects of material nonhomogeneity and nonisothermal conditions on the stress response of pressurized tubes are assessed by virtue of a computational model. The modulus of elasticity, the Poisson's ratio, the yield strength, and the coefficient of thermal expansion, are assumed to vary nonlinearly in the tube. A logarithmic temperature distribution within the tube is proposed. Under these conditions, it is shown that the stress states and the magnitudes of response variables are affected significantly by both the material nonhomogeneity and the existence of the radial temperature gradient.

Elastic Buckling Analysis of Single Hat Rectangular Tubes (단일 모자형 사각 단면 부재의 탄성좌굴해석)

  • 김윤영;한창운
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.19 no.5
    • /
    • pp.1251-1258
    • /
    • 1995
  • An elastic buckling analysis of single hat rectangular tubes is carried out. Based on Bleich's buckling theory for elastically restrained plates, a method to estimate the compliance of the supporting plates for the buckling plate and to compensate the effects of compression force acting on the supporting plates is offered. Necessary assumptions which enable an analytic approach to be used are also given. The present results are compared with the finite element results obtained from ABAQUS.