• Title/Summary/Keyword: Tubes

Search Result 3,122, Processing Time 0.031 seconds

Evaluation of prolonged pain in preterm infants with pneumothorax using heart rate variability analysis and EDIN (Échelle Douleur Inconfort Nouveau-Né, neonatal pain and discomfort scale) scores

  • Buyuktiryaki, Mehmet;Uras, Nurdan;Okur, Nilufer;Oncel, Mehmet Yekta;Simsek, Gulsum Kadioglu;Isik, Sehribanu Ozluer;Oguz, Serife Suna
    • Clinical and Experimental Pediatrics
    • /
    • v.61 no.10
    • /
    • pp.322-326
    • /
    • 2018
  • Purpose: The EDIN scale (${\acute{E}}chelle$ Douleur Inconfort Nouveau-$N{\acute{e}}$, neonatal pain and discomfort scale) and heart rate variability has been used for the evaluation of prolonged pain. The aim of our study was to assess the value of the newborn infant parasympathetic evaluation (NIPE) index and EDIN scale for the evaluation of prolonged pain in preterm infants with chest tube placement due to pneumothorax. Methods: This prospective observational study assessed prolonged pain in preterm infants with a gestational age between 33 and 35 weeks undergoing installation of chest tubes. Prolonged pain was assessed using the EDIN scale and NIPE index. Results: There was a significant correlation between the EDIN scale and NIPE index (r=-0.590, P=0.003). Prolonged pain is significantly more severe in the first 6 hours following chest tube installation (NIPE index: 60 [50-86] vs. 68 [45-89], P<0.002; EDIN score: 8 [7-11] vs. 6 [4-8], P<0.001). Conclusion: Prolonged pain can be accurately assessed with the EDIN scale and NIPE index. However, evaluation with the EDIN scale is time-consuming. The NIPE index can provide instantaneous assessment of prolonged and continuous pain.

Structural Behavior of Flexurally Reinforced FRP-Concrete Composite Compression Member with FRP (FRP로 휨보강된 FRP-콘크리트 합성압축재의 구조적 거동)

  • Park, Joon-Seok;Joo, Hyung-Joong;Nam, Jeong-Hun;Yoon, Soon-Jong
    • Journal of the Korean Society for Advanced Composite Structures
    • /
    • v.1 no.3
    • /
    • pp.10-16
    • /
    • 2010
  • In construction industries, new construction materials are needed to overcome some problems associated with the use of conventional construction materials due to the change of environmental and social requirements. Accordingly, the requirements to be satisfied in the design of civil engineering structures are diversified. As a new construction material in the civil engineering industries, fiber reinforced polymeric plastic (FRP) has a superior corrosion resistance, high specific strength/stiffness, etc. Therefore, such properties can be used to mitigate the problems associated with the use of conventional construction materials. Nowadays, new types of bridge piers and marine piles are being studied for new construction. They are usually made of concrete filled fiber reinforced polymeric plastic tubes (CFFT). In this paper, a new type of FRP-concrete composite pile which is composed of reinforced concrete filled FRP tube (RCFFT) is proposed to improve compressive strength as well as flexural strength. The load carrying capacity of proposed RCFFT compression member is discussed based on the result of experimental and analytical investigations.

  • PDF

Study on the Effect of SBR Latex on the Properties of Soil Pavement (SBR Latex를 이용한 흙 포장의 재료특성 연구)

  • Lee, Sang Yum;Hwang, Sung Do;Yang, Sung Lin
    • International Journal of Highway Engineering
    • /
    • v.16 no.5
    • /
    • pp.73-82
    • /
    • 2014
  • PURPOSES : The purpose of this study is to determine the optimum addition rate of SBR latex through the evaluation of durability and strength of SBR latex applied soil pavement. Formerly used materials such as fly ash and cement in soil pavement had resulted in decreased durability due to micro crack by heat of hydration and shrinkage crack in winter. However, that agglutinated polymers help adhesion to aggregate increased comes up with preventing the crack opening when the number of capillary tubes of SBR latex get decreased in the hydration process of cement. Therefore, in this study, it is suggested that the evaluation of the field applicability of soil pavement be conducted through the performance lab test in terms of strength increment, adhesion improvement, and crack resistance based on SBR latex addition rate. METHODS : In order to evaluate the field applicability of soil pavement, SBR latex was added 0 to 3% by 1% increment, with fixed cement contents of 3% and 5%. The resistance of shear failure and crack of soil pavement were evaluated by performing the uniaxial compressive strength test and indirect tensile strength test at -20 and $20^{\circ}C$, respectively. RESULTSCONCLUSIONS : It was found out that from both tests, resistance of shear failure and crack were improved with increment of curing time, and especially more than 2% of SBR latex addition rate and 5% cement content gave better results.

A Comparison Study of Heat Loss Characteristics in Monofilament and Multifilament Superconducting Coils Driven with AC Currents (단일필라멘트와 다중필라멘트 초전도 코일의 교류 전류에 의한 발열 특성 비교 평가)

  • Hwang, S.M.;Kim, K.;Kang, C.S.;Lee, S.J.;Lee, Y.H.
    • Progress in Superconductivity
    • /
    • v.13 no.2
    • /
    • pp.111-116
    • /
    • 2011
  • Since superconducting wires have no resistance, electromagnets based on the superconducting wires produce no resistive heating with DC current as long as the current does not exceed the critical current of the wire. However, unlike resistive wires, superconducting wires exhibit AC heat loss. Embedding fine superconducting filaments inside copper matrix can reduce this AC loss to an acceptable level and opens the way to AC-capable superconducting coils. Here, we introduce an easy and accurate method to measure AC heat loss from sample superconducting coils by measuring changes in the rate of gas helium outflow from the liquid helium dewar in which the sample coil is placed. This method provides accurate information on total heat loss of a superconducting coil without any size limit, as long as the coil can fit inside the liquid helium dewar. With this method, we have evaluated AC heat loss of two superconducting solenoids, a 180-turn solid NbTi wire with 0.127 mm diameter (NbTi coil) and a 100-turn filamented wire with 1.4 mm diameter where 7 NbTi filaments were embedded in a copper matrix with copper to NbTi ratio of 6.7:1 (NbTi-Cu coil). Both coils were wound on 15 mm-diameter G-10 epoxy tubes. The AC heat losses of the NbTi and NbTi-Cu coils were evaluated as $53{\pm}4.7\;{\mu}W/A^2Hzcm^3$ and $0.67{\pm}0.16\;{\mu}W/A^2Hzcm^3$, respectively.

A Study on the Shape and Cone Resistance of Dredged Fill in Geotextile Tube under Water and Drained Conditions (준설토의 퇴적형상과 수침조건에 따른 토목섬유 튜브 내 준설토의 콘 저항치에 관한 연구)

  • Kim, Hyeong Joo;Won, Myoung Soo;Lee, Jang Baek;Kim, Young Shin
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.36 no.1
    • /
    • pp.85-96
    • /
    • 2016
  • A series of tests were conducted to examine the filled tube shape with respect to the filling module type used and to investigate cone resistance properties of a dredged-soil-filled geotextile tube under water and drained conditions. Results based on the filling observation showed that the distribution of the accumulated fills inside the acrylic cell and vinyl tubes differs with respect to the type of filling modules. A crater formation around the inlet area was found during the test using I-type filling module and a horizontal sediment distribution was found during the test using inverse T-Type filling module. The dredged fill material was obtained from the Saemangeum area. The geotextile tube deformation of each filling stage was almost converged when the tube was fully drained. The cone resistance of the dredged fill in the geotextile tube under drained condition is large and is approximately 2~6 times that of the tube under water condition.

A Study on the Structural Integrity Considering the Installation of a Micro-tube Heat Exchanger (미세튜브 열교환기의 장착을 고려한 구조건전성에 관한 연구)

  • Oh, Se Yun;Kim, Tae Jin;Cho, Jong Rae;Jeong, Ho Sung
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.39 no.4
    • /
    • pp.447-451
    • /
    • 2015
  • The objective of this study is to predict the structural characteristics of a heat exchanger mounted on an aircraft engine using finite element analysis. The plastic fracture and life of the heat exchanger were estimated by a thermo-mechanical analysis. Tensile tests were conducted under high temperature conditions (700, 800, 900, 1000 K) using five specimens to obtain the mechanical properties of the Inconel 625 tubes. To assess the structural characteristics of the heat exchanger, the full and partial models were applied under the operating conditions given by the thermo-mechanical and inertial load. As a result, the case, tubesheet, flange, and mounting components have a reasonable safety margin to the allowable stress assuming a fatigue strength of Inconel 625 of 10000 cycles under 1000 K.

A Comparative Study on Characteristics of Nanofluids Using Carbon NanoTubes (탄소 나노튜브를 이용한 나노유체의 특성 비교 연구)

  • An, Eoung-Jin;Park, Sung-Seek;Kim, Nam-Jin
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.74.1-74.1
    • /
    • 2011
  • 탄소나노튜브는 높은 전기 전도성과 열 전도성을 가지며, 이러한 특성 때문에 21세기를 주도해 나갈 수 있는 차세대 첨단 소재로서 각광을 받고 있다. 또한 최근에는 나노공학기술의 발달로 인하여 획기적으로 높은 열전도도를 나타내는 다중벽 탄소나노튜브(Multi-walled Carbon Nanotubes, MWCNTs)의 대량 생산이 가능하게 되면서 다중벽 탄소나노튜브의 높은 열전도도 특성을 이용하여 탄소나노튜브를 기본 유체 및 기능성 유체에 안정하게 분산 시킨 후 이를 이용하고자 하는 연구가 활발히 진행되고 있으며, 탄소나노튜브를 유체에 안정하게 분산시키기 위한 방법으로는 기계적 분산법, 물리적 흡착에 의한 분산법, 화학적 개질에 의한 분산법이 있다. 따라서 본 연구에서는 이들 분산 방법과 탄소나노튜브 입자의 물성치에 따른 나노유체의 특성을 알아보기 위하여 나노유체의 열전도도와 점도 특성을 비교 분석하였다. 모든 물성치는 같지만 탄소나노튜브의 길이만 다른 두 종류의 다중벽 탄소나노튜브에 각각 계면 활성제(Sodium Dodecyl Sulfate, SDS) 100 wt%와 고분자 화합물(Polyvinyl Pyrrolidone, PVP) 300 wt%를 첨가하여 나노유체를 제조하였으며, 산화처리 된 다중벽 탄소나노튜브(Oxidized Multi-Walled Carbon Nanotubes, OMWCNTs)를 증류수에 초음파 분산하여 산화나노유체를 제조하였다. 나노유체의 열전도도는 전기 전도성 유체의 비정상 열선법(Transient Hot-wire Method)을 이용하여 측정하였고, 나노유체의 점도는 회전형 디지털 점도계를 이용하여 측정하였다. 실험 결과, 상온에서 동일 혼합비의 나노유체를 비교했을 때, 산화나노유체가 SDS 100 wt%, PVP 300 wt%를 혼합한 다른 나노유체보다 높은 열전도도 특성을 보였으며 점도 특성 또한 가장 낮은 것으로 측정되었다. 특히 상온에서 0.1vol%의 산화 CM-100 나노유체는 증류수보다 열전도도가 8.34%가 증가하였고, $10^{\circ}C$의 저온에서는 상온에서 증류수와 비교하여 측정된 열전도도 값보다 0.36%가 감소한 7.98%가 증가함을 보였다. 본 연구를 통하여 얻어진 결과는 높은 열전도도를 필요로 하는 열교환기의 작동유체나 기타 활용 분야에 대한 기초 자료로써 유용한 정보를 제공할 것이라 판단된다.

  • PDF

Eddy Current Bobbin Probe Design for Steam Generator Tubes in NPPs (원전 증기발생기 전열관 와전류검사 보빈탐촉자 설계)

  • Nam, Min-Woo;Lee, Hee-Jong;Jee, Dong-Hyun;Jung, Jee-Hong;Kim, Cheol-Gi
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.27 no.2
    • /
    • pp.89-96
    • /
    • 2007
  • The bobbin probe examination is basic and the important method among other ECT techniques for the steam generator tube integrity assesment that is practiced during each plant outage. The bobbin probe is one of the essential components which consist of the whole ECT examination system, and provides us a decisive data for the evaluation of tube integrity in compliance with acceptance criteria described in specific procedures. The selection of examination probe is especially important because the quality of acquired ECT data is determined by the probe design characteristics, such as geometry and operation frequency, and has enormous effects on examination results. In this study, An optimal differential bobbin probe is designed for the steam generator tube inspection in nuclear power plants(NPPs). Based on the test results for electrical and ECT signal characteristics, the prototype bobbin probe satisfies all the criteria.

Research on the Adsorption Capacity for Benzene, Toluene, Acetone and N-hexane of Activated Carbon Acquired fromthe Domestic Market (국내에서 유통되는 활성탄을 이용한 벤젠, 톨루엔, 아세톤 및 노말 헥산의 등온흡착용량 평가 연구)

  • Lee, Naroo;Yi, Gwangyong;Park, Dooyong
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.24 no.2
    • /
    • pp.193-200
    • /
    • 2014
  • Objectives: To develop domestic charcoal tubes with good adsorption capacity, breakthrough experiments were performed on four types of activated charcoal. Materials: The adsorption capacity and the adsorption rate were determined using a modified Wheeler equation after the breakthrough experiment. For four types of charcoal (J, K, S and SKC Inc. 226-01), 100 mg were used in the breakthrough experiment. The test was done on benzene, toluene, n-hexane, and acetone in a dynamic chamber. Results: K charcoal had the greatest surface area and the highest micropore volume. J charcoal had a similar surface area and micropore volume to SKC charcoal. S charcoal had the lowest surface area and micropore volume. J charcoal had the highest adsorption capacity at 101, 252 and 609 ppm of benzene. The gap in benzene adsorption capacity among the types of charcoal was the least at 609 ppm and the greatest at 101 ppm. J charcoal showed the highest adsorption capacity at 54, 106, 228 and 508 ppm of toluene. J charcoal and SKC charcoal had a similar adsorption capacity for acetone. J charcoal had the highest adsorption capacity for n-hexane. In the experiment featuring 10% breakthrough volume, 10% breakthrough occurred at 18 liters at $2065.9mg/m^3$ for J charcoal and at 20 liters at $1771.2mg/m^3$ for K charcoal. It was difficult to judge adsorption capacity by surface area and micropore volume of charcoal. J charcoal, which was similar to SKC charcoal in surface area and micropore volume, showed good adsorption capacity at common workplace concentrations. Conclusions: The adsorption capacity of J and K charcoal was superior compared with SKC charcoal. J and K charcoal can be considered appropriate for use as sampling media based on this result.

An Experimental Study on the Prediction of Yield Load Using Ring Analysis Method in Circular Tubular X-Type Cross Sections (링해석법에 의한 X형 강관 격점부의 항복하중 예측에 관한 실험적 연구)

  • Park, Il Min;Na, Seon Hong
    • Journal of Korean Society of Steel Construction
    • /
    • v.11 no.1 s.38
    • /
    • pp.43-54
    • /
    • 1999
  • The divergence connection between steel circular tubes is widely used in such structures as factory facilities, steel circular hollow section truss, and off-shore tower. Steel circular hollow section (SCHS) have close section, and it makes their per-unit production expense higher than open sectioned products like L-shape, H-shape steels, but the sectional resistance of SCHS against vertical compression and torsion is very high. Despite the structural merits of SCHS, however, many engineers dislike to use them in their design because of uncertainty regarding the stress distribution and deformation behavior at their connections. Therefore, this thesis dealt with X-type connections, the most common forms of connection, and studied their load-deformation relationship. It observed how to show the load-deformation relationship at steel circular tube connections according to the diameter-thickness ratio (D/T) of the chord and diameter of branch-diameter of chord ratio (d/D) and suggested prediction yield load using by ring analysis method.

  • PDF